Product Application. Prestige Power Post in White Epoxy Coated Aluminium Finish

Similar documents
ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

C&G 2382 BS7671: th Edition IEE Wiring Regulations. 25 Questions

BUILDER S CONSTRUCTION SUPPLIES (Temporary in permanent position) REQUIREMENTS. March 2014

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Part Three Workmanship and Materials

Electric Service Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

elevate your flexibility

UNDERGROUND SERVICES SECONDARY

Fixings, bonds and clamps

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Cable junction boxes with intrinsic fire resistance and insulation integrity

D300. By Actiu.

SECTION GROUNDING AND BONDING

Armoured Instrumentation Cables to BS7917

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

LED Power factor: 0.9 Colour rendering index: 80 Luminous flux maintenance 80%: 50000h (L80B20) Colour temperature: on request 3000K and 6000K

UNDERFLOOR HEATING SYSTEM INSTALLATION MANUAL LIFETIME WARRANTY INSTALLATION MANUAL. Ideal for large areas. Easy to install

Project comparison: old system. One-to-one fixture replacement without changing the existing electrical system

Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.

Construction guideline

FREQUENTLY ASKED QUESTIONS

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

ILKAclean Clean Room Systems

Technical Specification for LV ABC Fuse Switch Disconnectors

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Section 2: Underground

Cannon Trident Connector System

ENERGY-DISTRIBUTION. TwinLine N 44 The new system of floor-standing cabinets in IP44

PORTISO is a company dedicated to the manufacturing of isothermal doors built to satisfy the different needs of any industrial sector.

Protection classification IP 23

(Condensed from National Electric Code)

TECHNICAL SPECIFICATION

The Canadian Electrical Code (Saskatchewan Amendments) Regulations, 1999

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

WOOD POLE SPAN WIRE SIGNAL SYSTEMS

ACO Utility Enclosure Products

ALTERNATOR. LSA 36 - single-phase to 11.5 kva

Project comparison: old system. One-to-one fixture replacement without changing the existing electrical system

Safety Barrier Solutions

Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System

Access Chambers Systems

The complete guide to transformers and packaged substations

Service Entrance Cable Fittings

Sensor unit MC2 for toxic gases and oxygen with analog output

Bonding Leads. Metal Braids FLAT ROUND ROPES BONDING LEADS POWER SHUNTS. The answer to your cable management needs. INTRODUCTION

ELECTRICAL SAFETY INSPECTION REPORT

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

SPECIFICATION SHEET JUNCTION BOXES

TESTING PTE EARTHING

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox

ELECTRO-FENCE. Fence Protection System. System Manual. EF_System_V1.1

MR 120/2015. SUPPLY OF 2 X 2MVA 415V/11kV 3 PHASE TRANSFORMERS

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

2015 Code Rollout Meeting Q & A

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

WIRING METHODS CHAPTER 38

CANAL COMPACT & CANAL PLUS. powerful warmth, perfectly integrated

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

» Bolted system. the flexible classic. Plug-in system Bolted Office shelving Wide-span shelving Pallet racking Cantilever racking.

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION INSULATED WIRE AND CABLE

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

Section 5 Roller Chain Drive Components

Integrated Solutions. The food & beverage. for. Global specialist in electrical and digital building infrastructures

RMF Intercell. NBS Specification 2013 K41

Pre-installation Manual CONCEPT 301 D/401 D/501 D

GUIDELINES FOR SUB-SYSTEM COMPLETION CERTIFICATES AND TEST RECORDS FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES

INTRODUCTION. We feel pleasure to introduce ourselves as manufacturers and suppliers of multifarious industrial storage systems and cable tray.

3M Intelligent Return Plus and Sorter System SL. Architect/Contractor's Package

E-Series Steel Gantry Crane

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

CONDUITS AND FITTINGS

min. 50min. 65min. PIT / P3 / P4 Ø

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

July Metal Braids. Screening Braid and Bonding Leads

PRODUCT RANGE CABLE GLANDS

RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R3 Updated April 2005

Model BF 720 Incubators Avantgarde.Line with forced convection

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

1. GENERAL INFORMATION CAUTIONS AND GENERAL NORMS DESCRIPTION AND INTENDED USE MARKING OF DTW WEIGHBRIDGES...

Product Specifications MRI Trench Duct

MOBILE SUBSTATIONS TRAILER AND SKID. tgood.com. Energy, Fast!

Code of practice for protective earthing of electrical installations

Trench Duct Class Catalog 5230CT9601R10/08

TEWA ELECTRONICS GROUP HIGH PRECISION NTC THERMISTORS AND TEMPERATURE SENSORS

SECTION 9810 ACOUSTICAL SPACE UNITS BAFFLES AND CLOUDS

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

DISCONTINUED CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number:

GV 001 Equipment Bases and Enclosures General Information

Cold Rooms Kide

DIRECTORATE OF ESTATES

Steelwork and Security Kiosks

Transcription:

Product Application 83 Prestige Power Post in White Epoxy Coated Aluminium Finish

84 Floor Distribution Technical

Floor Distribution Technical 85 Range Technical Data Raised Floor Systems Interact Underfloor Power 86-87 NEW Cablelink Plus Modular 88-91 NEW Cablelink Plus Single Pan Box 92-93 NEW Cablelink Plus Raised Floor Trunking 94 Slab Boxes Grommets 95 DeskPod 96 Screeded Floor Systems NEW Onix Plus 97-100 NEW Cablelink Plus Screed System 101-106 NEW Cablelink Plus Flush System 107-112 Overhead Systems Interact Overhead Power 113-114 Hangmann

86 Technical raised floor systems Interact Underfloor Power Typical floor layout 2.7m 2.7m 2.7m 5.4m 3m TAP-OFFS GIVE 100% FLOOR COVERAGE WITH SOCKETS POSITIONED EVERY 300mm 5.4m 5.4m 2.7m Dimensions ø16/20mm CONDUIT ASSEMBLY ø25mm KNOCKOUT ø25mm HOLE 1.2, 2.4 OR 3.6m LENGTHS 77mm 50.5mm 22.5mm 53.5mm Elevating fixing Brackets should be positioned within 300mm from either end of a track run and either side of all joints. 300mm max 300mm max Minimum support requirement: 3.6 metre length = 4 brackets equally spaced 2.4 metre length = 3 brackets equally spaced 1.2 metre length = 2 brackets equally spaced

Interact Underfloor Technical 87 raised floor systems Interact Underfloor Power Technical Specification Underfloor 63A and 40A complies with BS EN 61534:2003 Manufactured within ISO 9000-9002 environment. Electrical Specification 63A 40A Rated Current 63 40 A Rated Voltage 480 480 V Frequency 50/60 50/60 Hz Conditional Short Circuit Rating 16 16 ka Resistance per Copper Conductor (At ambient temperature 20ºC) 1.3 3.0 mω/m Impedance per Copper Conductor (At ambient temperature 20ºC) 1.3 1.3 mω/m Volt Drops (Full load, concentrated at one end) (Line + Neutral) Powertrack 2.9 2.9 mv/a/m Feed Unit 0.6 0.6 mv/a Tap-off Connection 1.6 1.6 mv/a + 4mm 2 Cable 10 10 mv/a/m + 2.5mm 2 Cable 18 18 mv/a/m Joint 0.6 0.6 mv/a Flexible interlink Unit 0.8 0.8 mv/a + 10mm 2 Cable 4.0 4.0 mv/a/m Earth Fault Loop Impedance Line Conductor 1.5 1.5 mω/m Earth Case 1.0 1.0 mω/m Copper 1.5 1.5 mω/m Copper + Case 0.75 0.75 mω/m Feed Unit (Line + Earth) 0.6 0.6 mω Tap-off Connection (Line + Earth) mω + 4mm 2 Cable R1 + R2 10 10 mω/m + 2.5mm 2 Cable R1 + R2 18 18 mω/m Joint (Line + Earth) 0.6 0.6 mω Flexible Interlink Unit (Line + Earth) 0.8 0.8 mω + 10mm 2 Cable R1 + R2 3.7 3.7 mω/m Mechanical Data 63A 40A Max. No. of Copper Conductors 5 5 Conductor Cross Section Area (Nominal) 14.4 14.4 mm 2 Powertrack Casing Copper Equivalent (Where Casing is Protective Earth) 14.5 14.5 mm 2 Cable Termination Capacity 16 16 mm 2 Tap-off Cable 32A 4.0 4.0 mm 2 Tap-off Cable 13A 2.5 2.5 mm 2 Tap-off Conduit Sizes 16/20 16/20 Ømm Flexible Interlink Cable 10 10 mm 2 Flexible Interlink Conduit 25 25 Ømm Integral Feed Conduit Entry 1 x 25 1 x 25 Ømm Feed Conduit Entry 2 x 25 2 x 25 Ømm IP Rating 4X 4X Materials Specification Powertrack Casing, Feeds and Brackets Galvanised Steel Conductors High Conductivity Copper Dust cover Powertrack Insulators 63A polyamide and Polyester 40A PVC Sockets / Tap-off Plug / Joint Mouldings Noryl SE1 (Modified PPO) Shutter Polycetal Tap-off/Interlink Flexible Conduit Galvanised Steel Tap-off Cable (Singles in Conduit) LSF Cable to BS 7211 (PVC Cable to BS 6004 available on request) Tap-off Cable (Multi-core) Multi-core Cable to BS 6500 & BS 7211 LSF cable standard (PVC Cable available on request) Tap-off Pins Line, Neutral & Copper Earth Copper and Phosphorous Bronze, tin plated Casing Earth Brass, tin plated Flexible Interlink Cable 10mm 2 cable to BS 6231 3m is actually 2.7/2.8 fully stretched shortened by 0.1-0.2m of slack to ensure remains flexible when wired up to module/

88 Cablelink Plus Modular Technical raised floor systems Cablelink Plus Modular Floorbox Cablelink Plus Raised Modular Floorboxes have been specifically engineered to ensure robustness, a faster installation and maximum life span flexibility. Tested to EN50085-2-2 to accept 5000N load Quick release blades ensure a fast and simple installation Designed to support Cat 6 structured cabling systems Choice of two frame sizes provide 3 and 4 module solutions to suit all applications Self Closing lid in accordance with IEC 61534-22 Wide range of power and data accessories available to meet all requirements Quality, reliability and safety come as standard Provision of RCD protection supports compliance with the 17th Edition Wiring Regulations 5 year guarantee Materials All plastic components are manufactured from UL94 V2 rated nylon. Metal components are manufactured from pre-galvanised steel, accessory plates are powdercoated or colour coated. RAL Colours Grey (GRY) = RAL 7011 Light Grey (LGY) = RAL 7046 Standards The Cablelink Plus Modular Floorbox supports compliance with the latest edition of the IEE Wiring Regulations (BS 7671:2008) and to BS EN50085 Part 1 and EN50085 Part 2-2. Additionally the floorboxes also comply with IEC 60670 Parts 1 and 23. Installation Cablelink Plus Modular boxes should not be installed in the following situations: Where protruding electrical cables are likely to cause a safety hazard In passageways, especially where trolleys or other vehicles may be used On escape routes, as this may impede the evacuation of the occupants from the building Where the cleaning methods employed result in the formation of pools of liquid or soaking of the floor surface Desks, chairs, shelving, filing cabinets should not be positioned on the floorbox as this will interfere with opening the lid Load Testing Load Testing of Floorboxes to EN50085 Part 2-2 (Clauses 10.5.103 and 10.5.104). The floorboxes have been tested to and comply with the loading requirements of EN50085 Part 2-2 (Cable trunking systems and cable ducting systems for electrical installations Part 2-2: Particular requirements for cable trunking systems and cable ducting systems intended for mounting underfloor, flushfloor, or onfloor). There are two loading criteria for the floorboxes - one with a point loading to replicate foot traffic for example, and the other, with a large plate to replicate fork trucks and heavier larger loads for example. For both loading criteria the maximum allowable deflection under load is 6mm and the maximum permanent deflection after the load has been removed is 3mm. The loading position is the centre of the lid. The Lid Deflection (loading) graph shows that the maximum point loading classification achieved is 3kN and the maximum large plate loading classification achieved is 5kN. The Permanent Deflection graph shows the permanent deflection from the test wheel loading at 3kN is 0.55mm and large plate loading at 5kN is 0.4mm. This is well within the maximum allowable deflection of 3.0mm. Note: This test data specifically refers to the 265x265mm sized floorbox frame assembly. The other floorbox sizes also comply with the required test criteria. Declarations of conformity are available on request for the entire range. Lid Deflection Cablelink Plus 265x265mm Frame Assembly Deflection under Load (mm) Permanent Deflection (mm) 7 6 5 4 3 2 1 0 3.5 3 2.5 2 1.5 1 Maximum Allowable Deflection Under Load (6mm) 0.5 1 1.5 2 2.5 3 3.5 4 Load (kn) Maximum Allowable Permanent Deflection (3mm) Point Loading Plate Loading 4.5 5 0.5 0 Large Plate Load (5kN) Point Load (3kN)