Functional safety in the process industry

Similar documents
FUNCTIONAL SAFETY CERTIFICATE. TVL/TVH/TVF Switchboxes

You would like to reduce your costs? You prefer a more reliable partner? We have the right approach for you.

Valve Manifold Solutions for Fieldbus Applications

Bürkert < > Bayer F3 Project Automation with valve islands and remote I/O systems for chemical plants of the future

Technological Training Programs

Food & Beverage Portfolio

Spring return and double acting pneumatic rack and pinion actuator

OPTIMASS 7400 Technical Datasheet

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

Partner for Automation

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Results of the IEC Functional Safety Assessment

Reliability of Safety-Critical Systems Chapter 2. Concepts and requirements

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Water was the beginning. 10 years of modular automation A retrospective

Automated valve control and monitoring. Valve-top control and indicator units

Automation and Drives OSEA Totally Integrated Automation SIMATIC. Process Automation. Exceeding requirements of a DCS

You rely on highly efficient packaging processes. You are looking for flexible automation. We create great solution packages.

FUNCTIONAL SAFETY CERTIFICATE. Topworx, Inc 3300 Fern Valley Road, Louisville, Kentucky, 40213, USA

The Benefits of Fieldbus Technology in Power Plants

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

Functional safety Safety instrumented systems for the process industry sector

IDS Pipeline Automation Reliable and cost-effective Solutions

Complete Automation Solutions

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

TABLE OF CONTENT

RVM System. Engineering GREAT Solutions. Setting the standard for reliability and safety Redundant Valve Manifold

Development of Safety Related Systems

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

High-Precision Platforms

Results of the IEC Functional Safety Assessment HART transparent repeater. PR electronics

Proline Added Values Simply clever. Proline in industries Innovative products for your business

Brief Summary of Last Lecture. Model checking of timed automata: general approach

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

Digital E3 Modulevel Liquid Level Displacer Transmitter

Over pressure Switching pressure difference (typical) Lower range Upper range

Liquid level switch BW 17

QINEO PULSE. The versatile welding machine for industry

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

ABB JOKAB SAFETY Products. Packaging industries Machine safeguarding solutions

Mechatronic pressure measurement. Applications. Special features. Description

Introduction and Revision of IEC 61508

Software for Calculation of complex safety Parameters for Systems in safety critical Applications

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

Tank Scale Service Checklist

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

EMOS. Electrolyzer Maintenance Optimization and Safety. General Specifications

COMBIMASS Thermal Gas Flow

T91 - How to Select the Right Machinery Safety Logic System

ALUBOX Series Junction boxes in IP66 aluminium alloy

ARC WHITE PAPER DART Ushers in the Next Generation of Intrinsic Safety

ARC STUD WELDING SYSTEMS

Results of the IEC Functional Safety Assessment. ABB, Inc. Baton Rouge, LA USA

Machine Builder s Guide to Improving Turns on the Floor Enhance your manufacturing efficiency through distributed modular controls architecture

Visual Level Indicators VLI

The complete guide to transformers and packaged substations

HEATMAX. Mechanical Installation and Commissioning Instructions HEATMAX

ProFoss for in-line process analysis of dairy powder

IEC KHBO, Hobufonds SAFESYS ing. Alexander Dekeyser ing. Kurt Lintermans

Energy Saving Services

Aerospace Manufacturing. Productivity and performance, from machining to final assembly

Electromagnetic flowmeter ProcessMaster FEP300/500 The first choice for the process industry

Flow Measurement SITRANS F M

LIQUID CONTROLS. Terminal and Bulk Plant Metering Applications. Application Brochure:

STERIS Continuous Effluent Decontamination (CED) System

Communication and Software

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Energy & Data Transmission Systems for Underground Applications

European MID Directive for Custody Transfer Measuring Instruments Proven, certified technology for Fiscal & Custody transfer applications

AT9000 Advanced Transmitter Absolute Pressure Transmitters

IMATIC PDM. Version 6.0 SP1

Mechatronics Courses by School Period

UNDERSTANDING SAFETY INTEGRITY LEVELS

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

Technical System Catalogue Modular PDU (PSM)

Weighing Terminals. IND780 Connectivity Communications Customized Solutions. Power and Performance for Advanced Weighing Applications

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Weighing Electronics. SIWAREX - PLC-based weighing modules SIWAREX FTC. Overview

VALVES. Prospector Series Poppet Valves 1/4" to 2" Air Pilot Actuated 2/2, 3/2, & 4/2 Inline Valves

Products Solutions Services. Field Xpert SFX350, SFX370 Rugged Handheld for Mobile Plant Asset Management

GRAVOTECH GROUP. Complete range of Integrable Fiber Laser Marking Solutions LASER SOLUTION F-SERIES.

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

AUSTRALIA S LARGEST WEIGHBRIDGE MANUFACTURER!

Smarte Feldgeräte Die Basis für Industrie 4.0 Vortragsreihe Automatisierungstechnik 2017

6485 Pneumatics Simulation Software (LVSIM -PNEU)

/ Hybrid Cooling Towers

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Accessories for Sample Gas Probe GAS 222

SKF Mechatronics Knowledge Engineering. From concept to reality

Field Automation with PROFIBUS and SIMATIC PCS 7. Product Brief April 2003

Transcription:

Functional safety in the process industry

You want that feeling of security. You require uninterrupted production. We bring you safety and reliability. Our expertise Your advantage Page 3 SIL Safety Integrity Level Page 4 SIL in concrete terms 2

SIL Safety Integrity Level Safety equipment in process plants aims to reduce the hazards presented by processes for people, the environment and property to the lowest possible, acceptable level. Depending on the potential hazards, plants are assigned a Safety Integrity Level (SIL1 to SIL4). SIL1 represents the lowest risk and SIL4 the highest acceptable risk with catastrophic consequences. As a general principle, the more hazardous the plant, the more reliably its safety equipment must operate in case of an emergency. Once a plant is assigned a SIL level, specific installation principles must be observed, e.g. redundant design. This enables the risk to be reduced to the greatest possible extent in the event of a malfunction. SIL (Safety Integrity Level) S1 F1 S2 F2 F1 S3 F2 S4 P1 P2 P1 P2 W1 W2 W3 SIL1 SIL1 SIL1 SIL2 SIL1 SIL1 SIL3 SIL2 SIL1 SIL3 SIL3 SIL2 SIL4 SIL3 SIL3 SIL4 SIL4 SIL3 S F P Extent of damage S1 Minor injury to a person S2 Severe injury to several persons or death of a person S3 Deaths of several persons S4 Catastrophic consequences with multiple deaths Frequency and exposure time F1 Seldom to relatively frequent F2 Frequent to continuous Avoiding/mitigating the danger P1 Possible under certain conditions P2 Hardly ever possible Four discrete levels (SIL1 to SIL4). The higher the SIL of a safety-related system, the lower the probability of the system not being able to execute the necessary safety functions. W Probability of occurrence W1 Relatively high W2 Low W3 Very low Page 6 Components for safety-related applications Page 9 Redundant system conditions for safety-related applications Page 12 Solutions for safety-related applications 3

SIL in concrete terms The standards: The basic standard for functional safety is IEC 61508, entitled "Functional Safety of Electrical/Electronic/ Programmable Electronic Safety-Related Systems". IEC 61511, entitled "Functional Safety Safety Instrumented Systems for the Process Industry Sector" applies to process automation. IEC 61508 describes the method for assessing risks (using a riskograph) and the measures required to design suitable safety functions, ranging from sensors and logic circuits to actuators. A safety circuit, or SIS Safety Integrated System normally consists of the following components: Sensors, e.g. pressure, temperature, fill level gauge Evaluation and output unit, e.g. a safety PLC Automated process valve comprising solenoid valve, actuator and process valve IEC 61511 describes the specific implementation of IEC 61508 for the process industry. The focus here is on applications with a low demand mode. In process plants, this represents most safety functions. Important to know The requirement for failure probability to IEC 61508 always refers to a complete protective device and not to individual components. A component, in and of itself, can therefore not have a SIL level, only a complete safety circuit can. Relevant characteristic values for calculating SIL PFD (Probability of Failure on Demand): Probability that a safety function will fail in low demand mode (demand rate/year < 10) Low Demand PFH (Probability of Failure per Hour): Probability that a safety function will fail during continuous use (demand rate/year > 10) High Demand SFF (Safe Failure Fraction): Proportion of safe failures out of the total number of failures HFT (Hardware Failure Tolerance): Ability of a requested function to continue to perform during errors and deviations HFT0: An individual error can lead to the loss of the safety function, e.g. 1oo1 connections HFT1: At least 2 errors must occur simultaneously in order to cause a failure of the safety function, e.g. 1oo2 connections HFT2: At least 3 errors must occur simultaneously in order to cause a failure of the safety function, e.g. 1oo3 connections λ (Failure rates): S : Total failure rate for safe failures SD: Failure rate for safe, identifiable failures SU: Failure rate for safe, unidentifiable failures D: Total failure rate for dangerous failures DD: Failure rate for dangerous, identifiable failures DU: Failure rate for dangerous, unidentifiable failures MTBF (Mean Time Between Failure): Mean time between two successive failures Device type A: Device for which the failure behaviour of all components and the failure characteristics are adequately determined, e.g. through operational reliability. Device type B: Device for which the failure behaviour of at least one component and the behaviour in the event of a failure are not adequately determined. 4

Typical distribution of the PFD/PFH between the sub-systems of a safety function in single-channel systems Sensor 35% Logic 15% Actuator 50% What does SIL mean for operators? A company that erects and operates a system which represents a potential hazard for employees, local residents or the environment must minimise the risk presented by the process under fault conditions. To achieve end, both IEC 61508 and IEC 61511 essentially require the following steps to be carried out: PFD/PFH λ SD PFD/PFH λ SD PFD/PFH λ SD SFF λ SU SFF λ SU SFF λ SU 1. Risk definition and rating according to detailed failure probabilities for everything from sensors to controllers and actuators for the entire service life of the components. HFT λ DD HFT λ DD HFT λ DD MTBF λ DU MTBF λ DU MTBF λ DU SIL required (SIL r ) PFD total /PFH total Defined by the manufacturer To be determined by the system operator 2. Definition and implementation of measures to minimise residual risk. 3. Use of suitable equipment (evaluated or certified) 4. Periodic tests and inspections to ensure correct observation of the safety functions. Target: SIL SIL r SIL level Device type A Device type B Safe Failure Fraction (SFF) High Demand Mode Max. acceptable failure of the safety system < 60% 60...90% 90...99% > 99% < 60% 60...90% 90...99% > 99% Low Demand Mode Max. acceptable failure of the safety system 10 5 PFH < 10 4 One risk of failure every 10,000 hours 1 3x10 6 PFH < 10 5 One risk of failure every 1,250 days HFT 0 HFT 1 HFT 0 10 2 PFD < 10 1 Once every 10 years 10 6 PFH < 3x10 6 One risk of failure every 115.74 years 2 10 7 PFH < 10 6 One risk of failure every 115.74 years 3 10 8 PFH < 10 7 One risk of failure every 1,157.41 years 4 10 9 PFH < 10 8 One risk of failure every 11,574.1 years (per hour) HFT 1 HFT 0 HFT 2 HFT 1 HFT 0 10 3 PFD < 10 2 Once every 100 years HFT 2 HFT 1 HFT 0 HFT 0 HFT 2 HFT 1 HFT 0 10 4 PFD < 10 3 Once every 1,000 years HFT 2 HFT 1 HFT 1 HFT 2 HFT 1 10 5 PFD < 10 4 Once every 10,000 years HFT 2 HFT 2 HFT 2 5

Components for safety-related applications The product range presented here is used in systems for safety-related applications in the chemical and petrochemical industries. Products with a SIL3 compliance or higher require certification to IEC 61508 by an autonomous organisation; for products up to SIL2 the suitability can be declared by the company itself. The characteristic values required to calculate the achievable SIL level of an SIS system are detailed in the relevant certificate or user documentation. Components with SIL certificate Pilot valves VOFC For safety-related systems up to SIL3 in redundant cricuits or up to SIL2 in single-channel circuits for low demand, high demand and ESD (Emergency Shut Down) applications. Design principle: pilot operated Explosion protection to IEC Ex: EPL Gb/ EPL Db Explosion protection to ATEX: II 2 G / II 2 D Types of ignition protection, solenoid coils: Ex ia, Ex me, AEx-m IP65 housing protection Surface finish: aluminium (Ematal coated) stainless steel Operating conditions: indoors/outdoors Pilot valves VOFD For safety-related systems up to SIL3 in redundant circuits or up to SIL2 in single-channel circuits for low demand, high demand and ESD (Emergency Shut Down) applications. Design principle: direct acting Explosion protection to IEC Ex: EPL Gb / EPL Db Explosion protection to ATEX: II 2 G / II 2 D Types of ignition protection, solenoid coils: Ex me, Ex d, AEx-d IP65 housing protection Surface finish: Aluminium (Ematal coated) stainless steel Operating conditions: indoors/outdoors Quarter turn actuator DFPD Double- and single-acting for activating process valves in safety-related systems up to SIL3 in a redundant design or to SIL2 in single-channel design in low demand and high demand applications. Temperature range: 50 + 150 C Explosion protection to ATEX: II 2G c T4 X / II 2 D c 125 C X Rotation angle up to 180 Surface finish: stainless steel shaft, housing with epoxy coating 6

Sensor box SRBC For the electronic and visual position indication of automated process valves in safety-related systems up to SIL2 for lowdemand and high-demand applications. Housing protection IP67/NEMA 4/4X Type of ignition protection: Ex ia Explosion protection to ATEX: II 2G c X / II 2D c X ccsaus: ordinary location Operating conditions: indoors/outdoors Sensor box SRBE Visual position indication and electrical position sensing of automated process valves in safety-related systems up to SIL2 for low-demand and highdemand applications. Housing protection IP67/NEMA 4/4X Types of ignition protection: (A)Ex d, (A)Ex tb Explosion protection: To IEC Ex: EPL Gb / EPL Db ATEX: II 2G / II 2D CSA: Class I, Div 1; Class I Div 2 Class II, Div 1; Class III, T4A Class I, Zone 1; Class I, Zone 21 Operating conditions: indoors/outdoors How to find the SIL certificates/declarations 1st step: www.festo.com/supportportal 3rd step: Click on the Certificates tab 4th step: SIL certificate/declaration 2nd step: Enter the product type or part number 7

Components with SIL manufacturer's declaration Pilot valves VSNC With changeable seal for 3/2- or 5/2-way function, 5/2-way double solenoid and 5/3-way design. For safety-related systems up to SIL2. Design principle: pilot operated Types of ignition protection, solenoid coils: Ex ia, Ex m, Ex na, AEx-m IP65 housing protection Surface finish: aluminium Operating conditions: indoors Pneumatic linear actuator DLP Double-acting opening/closing linear actuator to activate process valves in safety-related systems up to SIL2. High corrosion resistance (CRC 3) for outdoor installations Contactless position sensing Port pattern to Namur VDI/VDE3845 for mounting solenoid valves ATEX certification: II 2 GD Pneumatic valve terminal MPA Maximum function integration, many electrical connection options, multi-pin plug, Festo I-Port, fieldbus and a comprehensive diagnostics concept. Suitable for use in safety-related systems up to SIL2. Different manifold block materials Optimised variants with increased flow rate Fast-switching valves available IP20 variant ideal for control cabinet solutions Pneumatic valve terminal CPV Intrinsically safe valve terminal with pneumatic multiple connector plate with wall through-feed, for use in safetyrelated systems up to SIL2. Protection class to IP65 Protection class IP65 also in conjunction with pneumatic multiple connector plate for control cabinet assembly CE marking Can be directly installed in Ex zone 1/21 8

Redundant system conditions for safety-related applications Process safety and reliability are always at the forefront when using redundant systems. Current safety circuits in process engineering are 1oo2 (One out of Two), 2oo2 (Two out of Two) and 2oo3 (Two out of Three). These are used in the production and processing of high-value and dangerous substances such as crude oil, natural gas, chemicals etc. The functions in the circuit diagram 1oo1 (One out of One) 1oo2 (One out of Two) 2oo2 (Two out of Two) 2oo3 (Two out of Three) A single failure can lead to an unsafe condition. Safety If a fault is detected in a valve, the entire system is exhausted. This leads to an unsafe condition and the system moves to a safe position. Increased uptime Only when both valves fail is the correct function no longer ensured and this leads to an unsafe condition. Safety and reliability At least three failures must occur simultaneously to cause an unsafe condition. To provide redundancy in the event that a valve fails, the above mentioned systems are installed in safety- or process-critical systems. Their compact design reduce the cost of the piping and simultaneously the potential for leaks in a system. This reduces assembly and operating costs of the plant. 9

Most widely used redundant systems at field level Safety (1oo2) With enhanced safety (1oo2), two valves are connected in series. Both valves are energised during operation. Should a valve or a solenoid fail during operation, the entire system is exhausted in order to protect it from subsequent damage. Media conveyor lines frequently require this higher level of safety. Increased uptime (2oo2) With increased uptime (2oo2), two valves are connected in parallel. Both valves are energised during operation. Should a valve or a solenoid fail during operation, the plant remains active and the entire system continues to work. For example, cooling circuits require this increased uptime. Redundant NAMUR block (1oo2 & 2oo2) The NAMUR block enables the installation of two solenoid valves VOFC or VOFD. The NAMUR interfaces make redundancy easy to implement. The advantages: low warehousing costs and easy replacement of solenoid valves. Both solenoid valves are redundantly interconnected and provide a redundant function for automated process valves. The blocks are available in fail-safe function (1oo2) or with increased uptime (2oo2) The NAMUR block can be mounted directly on quarter turn actuators using the standardised interface. Separate installation with suitable piping is also possible. With 1oo2 and using the additional auxiliary power terminal, the NAMUR block can also be used with piloted solenoid valves on actuators that have a positioner for failsafe functions. High flexibility due to the available types of ignition protection and global certification of the solenoid coils. Available with G and NPT connections. RFS block RIA block V1 1 3 12 V2 V1 1 3 12 V2 12 NAMUR interface to. VDI/VDE 3845 NAMUR interface to. VDI/VDE 3845 12 12 NAMUR interface to. VDI/VDE 3845 NAMUR interface to. VDI/VDE 3845 12 3 1 3 1 3 1 3 1 2 2 2 2 3 2 3 2 NAMUR interface to. VDI/VDE 3845 NAMUR interface to. VDI/VDE 3845 Redundant Fail Safe 1oo2 Redundant Increased Uptime 2oo2 10

Redundant INLINE valves (1oo2 & 2oo2) With these compact systems, Festo is drawing on the tried and trusted technology (proof-in-use) of the valves VOFD and is combining this in one housing. Thanks to the Ematal coating, these valves meet the highest safety standards in process engineering and can withstand the toughest of ambient conditions. Available types of ignition protection: Ex me, Ex d. Simple replacement of individual valve installations. The valve's redundant circuit ensures a redundant fail-safe function (1oo2) or provides increased uptime (2oo2) for automated process valves. High flexibility due to the available types of ignition protection and global certification of the solenoid coils. Compact and robust housing for installations in harsh ambient conditions. Available with G and NPT connections. 1oo2 (One out of Two) 2oo2 (Two out of Two) Safety and reliability Inline/ Namur (2oo3) There is a combination that provides maximum safety and reliability at the same time. This so-called 2oo3 system combines both technologies and meets the highest demands of a system. The block is an inline variant and is integrated in your system. The built-in standard valves are mounted on the block via the NAMUR interface. This opens up the opportunity for diversity in the design. It also means that individual valves can be easily replaced. In addition, with the 2oo3 system the functions of the four valves can be bypassed. This bypass can be unlocked with a key so that maintenance can be carried out during operation. The mechanical pressure indicators or pressure gauges, mounted directly on the valve block, always give a reliable and swift indication if a valve is pressurised. In addition, the mechanical displays can be replaced with electronic pressure sensors in order to reflect the status in the control system. 2oo3 (Two out of Three) 11

Solutions for safety-related applications 1. Actuator units from Festo ready to install Complete actuator units, whether single- or double-acting, save you time and money. We will build your ready-to-install and tested actuator unit in accordance with your requirements including for safetyrelated systems. To do this, we use automated process valves based on certified components with a corresponding SIL manufacturer's declaration. Fully assembled to your specifications Costs and time saving Ready to install SIL or ATEX assessment of the actuator with the corresponding manufacturer's declaration possible Designs for low temperatures 2. Panel and control cabinet solutions for safety-related applications Piped pneumatic control systems Festo offers a broad spectrum of pneumatic control systems. Our offer encompasses all stages of the value chain, from initial planning and engineering up to assembly, testing and delivery of the ready-to-install panels. Control cabinets for the process industry Control cabinet solutions tailored to your specifications and requirements protect the components used against environmental factors, fluids and foreign matter. You decide whether tubing or piped connections are more suitable for your purpose. Regardless of whether you are using pneumatic, electric or electropneumatic components, you will receive a control cabinet that is completely in line with your requirements. On request, we can subject the entire cabinet to a SIL assessment. For explosion protection, we also manufacture control cabinets in a 2GD or 3GD design with international approvals and in accordance with the U.S. NEC standard. 12

3. Current solutions for batch processes 3.1 PROFIBUS redundancy Festo uses a redundant PROFIBUS solution to increase the safety between the control system (DCS) and remote I/O. If a PROFIBUS line is removed or the PROFIBUS node is faulty, the second PROFIBUS line/node takes over. This reliably sends and receives the control system protocols. It has the further benefit that you can access the remote I/O directly on site via a controller with Ethernet interface and parameterise or implement additional processes. The triedand-tested technology of the CPX-P, with its input modules for connecting NAMUR sensors, reliably takes over the tasks of the control level. The modular terminal CPX together with the SIL2-rated valve terminal MPA is a compact alternative. DCS/PLC Level Fieldbus PROFIBUS cable PROFIBUS cable Input registers 1st FB13 Output registers Festo CPX terminal Input registers 2nd FB13 Output registers or Valve 1 Valve 2 Valve 3... Valve x Valve Terminal Input 1 Input 2 Input 3... CEC controller Input x Digital Input module 13

3.2.1 CPX/MPA with safety PLC Valve terminal with integrated safety shutdown to control separate actuators. In the operating mode, the valve terminal is activated via a fieldbus and switches actuators in the process. In addition, the valve terminal has a separate supply to the safety PLC, which actuates the valves on the valve terminal for the safety shutdown. The actuators for the operating mode and the actuators for the safety shutdown are connected in series. This solution is suitable for SIL2 circuits. To increase the safety level, there is also an option of interconnecting the valves redundantly. DCS/PLC Level Fieldbus Safety PLC 3.2.2 CPX/MPA with safety PLC Valve terminal with integrated safety shutdown to control actuators for operating and safety mode. DCS/PLC Level Fieldbus Safety PLC In operating mode, the valve terminal is actuated via a fieldbus and switches actuators in the process. In addition, the valve terminal has a separate supply to the safety PLC, which actuates the valves on the valve terminal for the safety shutdown. It also activates the same actuators in order to shut down the process safely. This solution is suitable for SIL2 circuits. To increase the safety level, there is an option to switch the valves redundantly. Mechanical safety converter 14

3.3 VOFC/D as a safety valve Valve terminal plus individual valve for safety shutdown. The operating mode is controlled via the fieldbus and the valve terminal and is used to switch actuators in the field. The certified individual valve mounted on the same actuator is directly actuated by the safety PLC and, if required, switches off safely. These valves can be used in safety-related circuits up to SIL3 level. DCS/PLC Level Fieldbus Safety PLC 15

Productivity Maximum productivity is a question of ambition Do you share this attitude? We would be happy to help you achieve this goal with our four outstanding qualities: Security Efficiency Simplicity Competency We are the engineers of productivity. Discover new dimensions for your company: www.festo.com/whyfesto 135821 en 2017/01 Errors and omissions excepted