MIIG INJECTABLE Graft The following languages are included in this packet:

Similar documents
PRO-STIM Injectable Inductive Graft Containing DONATED HUMAN TISSUE

TRELLIS COLLAGEN RIBBON

CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed physician.

HydroSet. Injectable HA Bone Substitute

NORIAN DRILLABLE TECHNICAL MONOGRAPH. Fiber reinforced calcium phosphate phate bone void filler

CRANIOS REINFORCED BONE VOID FILLER

Artist Proof: Clotalyst. Autologous Serum Collection System

TRUFILL DCS ORBIT Detachable Coil System

Comfort your patient deserves. Strength you demand.

PHYSICIAN OFFICE BILLING INFORMATION SHEET FOR IMLYGIC (talimogene laherparepvec)

Repliform. Tissue Regeneration Matrix. Instructions for Use. Distributed by:

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Universal Trocar Stability Sleeve. Reprocessed Device for Single Use.

Instructions for Use Reprocessed Ethicon ENDOPATH XCEL TM Dilating Tip Trocar with OPTIVIEW Technology

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

Symphion 6.3 Endoscope

Sterilization in Aesculap Sterilization Containers

Implants for surgery Active implantable medical devices. Part 3: Implantable neurostimulators

Section 8. To introduce the basic theory and principles of collecting blood for Intraoperative Cell Salvage (ICS)

Page 1 of 6 Reprocessed by. Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

Instructions for Use Reprocessed Balloon Inflation Devices

Insulin Syringes ACCU-SHOT TM ACCU-SHOT U40 & U100. (with Ultra Thin & Short Needle) Sizes. Colour Code of Top Cap ml U G 6 mm Red

Collagen Solutions Plc

Advanced FEA Stress Analysis of Medical Instruments and Devices using Femap, NX Nastran and LS-DYNA

Owner s Manual & Safety Instructions

THE SAFE DISPOSAL OF CLINICAL/DOMESTIC WASTE

Flash Back Function - During the insertion of the cannula, blood flow is visualized by blood flash back in the hub of the cannula.

4 rotary milling table

intervention embosphere embogold quadrasphere bearing nspva

RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)

NEXT GENERATION ECM-BASED ALLOGRAFT TECHNOLOGY:

REGULATORY LABELLING REQUIREMENTS AND ITS COMPARISON IN USA AND CANADA

First Experiences with the Ziehm Vision FD Mobile C-Arm with Flat-Panel Detector

Owner s Manual & Safety Instructions

Trabecular Metal Acetabular Revision System Cup-Cage Construct

Project Proposal Ultrasound Mediated Tissue Engineering Project Team 21

The neov endovascular

LOAD RAMP 1000 LB. CAPACITY

Model M120 Mini Temperature/Humidity Meter

Cranio-caudal Fixation Unit CC-GE MR10063-CC-GE

RIGID ENDOSCOPE OPERATING INSTRUCTIONS

21 CFR Ch. I ( Edition) Personnel Design controls Identification Traceability.

Cortical Bone Healing after Internal Fixation and Infection

92831 TEL: (714) FAX:

Understanding Clinical Equivalence

Policies Concerning Survival Surgery of Mice

GMP Specific Considerations for ATMPs

Cranio-caudal Fixation Unit CC-320-Plus

PHYSICO-CHEMICAL, BIOLOGICAL OR MICROBIOLOGICAL TESTS OF MEDICINAL PRODUCTS

Inspection Checklist for NIH BL3 Laboratories (7 CFR 331; 9 CFR 121; 42 CFR 73; NIH Guidelines)

Owner s Manual & Safety Instructions

Visit us at

PQS performance specification

Official Letter from DOH

Surgical Technique. and Product Catalog FOR NON-USA USE ONLY

Functional Assessment and Clinical Outcome

BRIC Surgical Sutures Market Outlook to 2020

We ve built a STRONG CASE. for changing the way you sterilize. Reusable Sterilization Container System

VISE MOUNTED. Model 97359

Owner s Manual & Safety Instructions

Protect the Neck. Lieven Maene, MD. Marc Bosiers Koen Deloose Joren Callaert. Patrick Peeters Jürgen Verbist. Lieven Maene Roel Beelen.

Clinical Waste. Policy. Responsibilities

Guidelines on procedures and data requirements for changes to approved biotherapeutic products. Proposed guidelines

POSITION PAPER Moving from the MDD to the MDR

MISSION - Set (align) the arm bone, then apply the blue cast. The cast needs to be all the way down, and it needs to completely cover the break.

DRYWALL DOLLY 900 LB. CAPACITY

Radiography Curriculum Analysis

Food and Drug Administration, HHS Pt Sec Scope Definitions Quality system.

This document is a preview generated by EVS

RePneu (Lung Volume Reduction) Coil System Instructions For Use

BAXTER UNVEILS DESIGN ENHANCEMENTS TO FLOSEAL AND TISSEEL HEMOSTATIC AGENTS AT AORN MEETING

Pneumatic PalletPal Level Loader

CoAxial Spray Kit And Applicator Tips. Simplifying the Application of Platelet and Plasma Concentrate

PART 820 QUALITY SYSTEM REGULATION. 21 CFR Ch. I ( Edition)

MEDPOR. Orbital Floor

PREVELEAK Surgical sealant

MEDICAL DEVICE GUIDANCE

MIE - H&S WHMIS

AUSTRALIAN MEDICAL DEVICES GUIDANCE DOCUMENT NUMBER 5. The Declaration of Conformity

Due diligence in the European medical devices industry

BIOSAFETY AND BIOSECURITY (BSS) Series Catalog

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

MEDICAL DEVICES : Guidance document

BIP Central Venous Catheter

Vacuum Forming Machine. Sheets. Instruction manual

1 TON PORTABLE GANTRY CRANE Model LB. PORTABLE GANTRY CRANE Model 94831

Regulated Medical Waste Management and Proper Waste Segregation. State-Specific Information New Jersey

Legal Aspects and Process of Biomedical Waste Management Practices in India. *Prakash V **Dr. N. Palaniraj

Doxorubicin Hydrochloride Liposome Injection

Stainless steel rolling cabinet

MEDICATION GUIDE RIBAVIRIN TABLETS Rx Only Read this Medication Guide carefully before you start taking ribavirin tablets and read the Medication

Sterile Compounding elearning Course Curriculum 28 lessons with 33 hours of CE. Fundamentals of Sterile Compounding (8 lessons/8 hours CE)

Transcription:

MIIG INJECTABLE Graft 128801-10 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt) 中文 - Chinese (sch) Türkçe (tr) For additional languages, visit our website www.wmt.com Then click on the Prescribing Information option. For additional information and translations please contact the manufacturer or local distributor. M* C 0086* P Wright Medical Technology, Inc Wright Medical EMEA 5677 Airline Rd Hoogoorddreef 5 Arlington, TN 38002 1101 BA Amsterdam U.S.A. The Netherlands * The CE-Marking of Conformity is applied per catalog number and appears on the outer label, if applicable. March 2012 Printed in U.S.A.

Attention Operating Surgeon IMPORTANT MEDICAL INFORMATION WRIGHT MEDICAL MIIG INJECTABLE Graft (128801-10) EN OUTLINE: DEFINITIONS I. GENERAL PRODUCT INFORMATION A. INDICATIONS B. CONTRAINDICATIONS C. POTENTIAL COMPLICATIONS D. PRECAUTIONS E. ADVERSE REACTIONS F. HANDLING & STERILIZATION G. STORAGE CONDITIONS H. DIRECTIONS FOR USE/MIXING INSTRUCTIONS

DEFINITIONS Symbols and abbreviations may be used on the package label. The following table provides the definition of these symbols and abbreviations. Table 1. Definitions of Symbols and Abbreviations Symbol g h D Y i H l p N M K Definition Batch code Catalog number Do not re-use Caution, consult accompanying documents Consult operating instructions Use by Storage temperature limitation Keep dry Keep away from sunlight Date of manufacture Manufacturer Sterilized using radiation For prescription use only I. GENERAL PRODUCT INFORMATION MIIG graft products consists of pre-measured surgical grade calcium sulfate, pre-measured mixing solution, and the tools necessary to mix the components into a paste and inject the material into the defect site. These products are provided sterile for single patient use. When mixed and injected according to directions, MIIG paste will harden in situ and provide temporary intra-operative support. The mini MIIG 115 kit contains a vial of calcium sulfate, a vial of sterile saline, a syringe, two delivery needles, a spatula, and a funnel. The MIIG 115 kit contains a vial of calcium sulfate, a vial of sterile saline, a syringe, two delivery needles, and a spatula. 2

The micro MIIG HV kit contains a vial of calcium sulfate, a vial of sterile water, a syringe, two delivery needles and four k-wires, a spatula, and a funnel. The MIIG X3 HiVisc kit contains a vial of calcium sulfate, a vial of sterile water, a syringe, two delivery needles, a spatula, five transfer syringes, and a vacuum mixing bowl All other MIIG X3 kits contain a vial of calcium sulfate, a vial of sterile water, a syringe, two delivery needles, a spatula, and a vacuum mixing bowl. A. INDICATIONS The MIIG paste is intended to be injected into open bone voids/gaps that are not intrinsic to the stability of bony structure of the skeletal system (i.e., the extremities, spine, and pelvis) and to cure in situ. These open bone voids may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. The MIIG paste provides a bone void filler that resorbs and is replaced with bone during the healing process. The MIIG paste cured in situ provides an open void/gap filler that can augment provisional hardware (e.g., K-Wires) to help support bone fragments during the surgical procedure. The cured paste acts only as a temporary support media and is not intended to provide structural support during the healing process. B. CONTRAINDICATIONS The MIIG paste is contraindicated where the device is intended as structural support in load-bearing bone and in articulating surfaces. Conditions representing relative contraindications include: Severe vascular or neurological disease Uncontrolled diabetes Severe degenerative bone disease Closed bone void/gap filler Pregnancy Uncooperative patients who will not or cannot follow postoperative instructions, including individuals who abuse drugs and/or alcohol Hypercalcemia Renal compromised patients Patients with a history of or active Pott s disease When intra-operative soft tissue coverage is not planned or possible C. POTENTIAL COMPLICATIONS Proper surgical procedures and techniques are the responsibility of the medical professional. Each surgeon must evaluate the appropriateness of the procedure used based on personal medical training and experience. Although Wright Medical cannot recommend a particular surgical technique suitable for all patients, a detailed surgical technique is available for surgeon reference. D. PRECAUTIONS As with any surgical procedure, care should be exercised in treating individuals with preexisting conditions that may affect the success of the surgical procedure. This includes individuals with bleeding disorders of any etiology, long-term steroidal therapy, immunosuppressive therapy, or high dosage radiation therapy. Avoid overfilling the bone void or pressurizing the treatment site. The provided K-wires (where supplied) are not intended for implantation. Use MIIG graft products as supplied and according to the Handling and Use information provided. This device has not been evaluated for safety and compatibility in the MR environment. This device has not been tested for heating or migration in the MR environment. 3

Warning: Do not use kit if glass vial is cracked or broken. Intra-Operative Precautions Use medical devices in accordance with their labeled indications and Wright Medical Technology s instructions for use, especially during insertion and removal. Inspect devices prior to use for damage during shipment or storage or any out-of-box defects that might increase the likelihood of fragmentation during a procedure. Inspect devices immediately upon removal from the patient for any signs of breakage or fragmentation. If the device is damaged, retain it to assist with Wright Medical Technology s analysis of the event. Carefully consider and discuss with the patient (if possible) the risks and benefits of retrieving vs. leaving the fragment in the patient. Advise the patient of the nature and safety of unretrieved device fragments including the following information: a. The material composition of the fragment (if known); b. The size of the fragment (if known); c. The location of the fragment; d. The potential mechanisms for injury, e.g., migration, infection; e. Procedures or treatments that should be avoided such as MRI exams in the case of metallic fragments. This may help to reduce the possibility of a serious injury from the fragment. E. ADVERSE EFFECTS Possible adverse effects include but are not limited to: Wound complications including hematoma, site drainage, bone fracture, infection, and other complications that are possible with any surgery Fracture or extrusion of the bone void filler, with or without particulate debris generation Deformity of the bone at the site Incomplete, or lack of, osseous ingrowth into bone void, as is possible with any bone void filler. Transient hypercalcemia Potential to pressurize material in a closed void, which could result in fat embolization and/or embolization of the device material into the blood stream. F. HANDLING AND STERILIZATION MIIG injectable graft products are provided sterile and should be considered sterile unless the inner packaging has been opened or damaged. This product should not be resterilized. The kits are for single patient use and should never be reused. Devices labeled for single-use only should never be reused. Reuse of these devices may potentially result in serious patient harm. Examples of hazards related to the reuse of these devices include, but are not limited to: significant degradation in device performance, cross-infection, and contamination. G. STORAGE CONDITIONS All kits must be stored in a clean, dry environment and be protected from sunlight and extremes in temperature. MIIG graft products should be stored at 15-30 C or 59-86 F. H. DIRECTIONS FOR USE/MIXING INSTRUCTIONS MIIG graft products are supplied in a kit that contains the components and tools required to mix and inject the resultant paste. Detailed mixing and handling instructions are included on the Mixing Instructions Card. 4