SECTION SPRAY APPLIED FLOOR ADHESIVE

Similar documents
SECTION SPRAY APPLIED WALL COVERING ADHESIVE

Vinyl Rx GUIDE SPECIFICATIONS Ecore Commercial

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

CONDUCTIVE RESILIENT FLOORING

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

RESILIENT PHOTOLUMINESCENT STAIR TREADS

Section Wood Grille Ceiling Panels

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

RESILIENT FLOORING: Select Step Wood

KOSTER AMERICAN CORPORATION

RESILIENT FLOORING: Hot and Heavy - Secoya

GUIDE SPECIFICATION

GUIDE SPECIFICATION

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

CHATTANOOGA, TN Last Updated: 04/12/17. NOTE TO SPECIFIER: Be sure to obtain the latest version of this Guide Specification.

Specification and Installation

SECTION WOOD FLOORING

SECTION WOOD FLOORING. 1. Section Above-Grade Vapor Retarders. 2. Section Below-Grade Vapor Retarders

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

Product Guide Specification

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

ACOUSTICAL WALL TREATMENT SECTION 09840

SECTION A. American Society for Testing and Materials (ASTM):

INSTRUCTIONS FOR EDITING AND COORDINATION SECTION WOOD FLOORING - ATHLETIC

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING

Regupol AktivPro RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER MOLDED TILES

by Rollfab Metal Products

SECTION RESINOUS MATRIX TERRAZZO FLOORING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION POLYACRYLATE MODIFIED CEMENTITIOUS TERRAZZO FLOORING

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

CSI GUIDE Countertops

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

HARO SPORTS FLOOR C.S.I. GUIDE SPECIFICATION Helsinki-Gymnasium Floor System 10/2010 SECTION WOOD ATHLETIC FLOORING

Everlast Smash Tile GUIDE SPECIFICATIONS Ecore

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

A. American Association of Textile Chemists and Colorists (AATCC): 1. AATCC 16, Test Method of Colorfastness to Light.

SECTION ULTRACOMPACT WALL FINISHES - THIN SET

HAWORTH PORCELAIN FLOORING SYSTEM CSI Specifications 03/29/2017. A. Concrete work and concrete floor sealer is specified in Section

Page 1 of 5 PART 1 GENERAL

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Section Polished Concrete Finishing. Vexcon

Action ReFlex Spin Resilient Floor System

Pliteq Inc. - LEED Summary

SECTION EXPANSION CONTROL

Section SoundPly LR M25 Acoustic Ceiling Panels

PRODUCT SPECIFICATIONS

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

TOLI INTERNATIONAL MATURE SELECT GUIDE SPECIFICATION LONG-FORM

FlexLok Adhesive Tabs for Carpet Tile

SECTION RESILIENT SHEET FLOORING

Application Specification:

ENKASONIC FLOOR UNDERLAYMENT 9110

CONTRACT PAGE 1 OF 5

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

SECTION EPOXY TERRAZZO

Product Guide Specification

High Panel - KC129. Karastan. MasterFormat Number: Sheet Carpeting

Floor Insulation Underlayment Section Sound Control Matting

Installation Guide LVP Glue Down

1.1 Related Work Specified in Other Sections (Delete if Not Applicable):

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Genentech Building 20 Office LEED-CI Gold XL CONSTRUCTION

Close Up - BC379. Bigelow. MasterFormat Number: Sheet Carpeting

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

SECTION QUARTZ SURFACING COUNTERTOPS

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Guideline Specifications

SECTION LINEAR WOOD CEILINGS

GUIDE SPECIFICATIONS IN CSI FORMAT: RESILIENT FLOORING

VINYL COMPOSITION TILE

SECTION SILOXANE WATER REPELLENTS

SECTION EPOXY TERRAZZO

WOOD FLOORING WOOD FLOORING

HPL CSI 3-PART SPECIFICATION FORM

Matuto. Global Entry Collection. Manufacturer Brand MasterFormat Number. Mohawk Group Hard Surface Resilient Tile Flooring PRODUCT ATTRIBUTES

CHAMPAIGN CENTRAL HIGH SCHOOL COMBES GYM FLOOR REPAIR. A. Submittals: Product Data, Specification Sheets, Samples and Manufacturer Warranty.

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

TILE TILE

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

2018 Flooring Specification - Tile Set Method TECTURA DESIGNS CEMENT TERRAZZO TILES

TOPCOAT Restoration Specifications Structural Concrete

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

EDGEWATER, FLORIDA JUNE 14, 2010

Resilient and Wood Floor Covering Flatness Requires High Performance, Cementitious Self-Leveling Underlayment

SECTION GYPSUM CEMENT UNDERLAYMENT RECOMMENDED SPECIFICATION FOR DURA-CAP FLOOR UNDERLAYMENT OVER EXTRUDED OR EXPANDED POLYSTYRENE FOAM

UNIFIED FACILITIES GUIDE SPECIFICATIONS

A. Section Includes: SpectraPour Poured-in-Place Playground Surfacing System

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Magnum Board Section Digicon Information Inc. Page 1

INSTALLATION INSTRUCTIONS FOR GERFLOR TARASAFE ULTRA VINYL SHEETGOODS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Transcription:

PART 1 - GENERAL 1.1 SUMMARY SECTION 09 00 50 CSI 3-PART SHORT-FORM GUIDE SPECIFICATION: USE FOR OUTLINE OR DD SPECIFICATION ISSUES. EDIT TO SUIT PROJECT A. Work of this Section consists of spray adhesive, and includes but is not limited to the following: 1. Spray-Lock 0.02 g/ml VOC Spray Adhesive for Flooring 2. Substrate preparation 3. Substrate testing B. Related Documents and Sections: Examine Contract Documents for requirements that directly affect or are affected by Work of this Section. A list of those Documents and Sections include, but is not limited to the following: 1. Drawings and general provisions of the Contract, including General and Supplementary Conditions and DIVISION 01 General Requirements, and DIVISION 01 through 9 Specification Sections, apply to this Section. 1.2 ADMINISTRATIVE REQUIREMENTS A. Coordination in accordance with DIVISION 01, and as follows: 1. Coordinate concrete slab or concrete topping finish in accordance with DIVISION 03, and as required by DIVISION 09 finish flooring material manufacturer. 2. Coordinate wood-based panel underlayment in accordance with DIVISION 06, and as required by DIVISION 09 finish flooring material manufacturer. 1.3 SUBMITTALS A. Product Data: Submit manufacturer's printed descriptions of materials, components and systems; performance criteria; use limitations; preparation instructions and recommendations; storage and handling requirements and recommendations; and installation methods. B. Quality Assurance Submittals: Certificates, and Test and Evaluation Reports. C. Sustainable Design (USGBC LEED ) Submittals: 1. LEED Credit IEQ, Indoor Environmental Quality. Complete online LEED forms and submit other required materials as follows: a. LEED 2009 IEQ 4.1, Low Emitting Materials, Adhesives & Sealants: Submit VOC Data b. LEED 2009 IEQ 4.3, Low Emitting Materials, Carpet and Resilient Flooring Systems: Submit CRI Green Label Certificate LEED v4 (below) may be used projects after November 20, 2013 or LEED 2009 (above) may be used on projects until October 31, 2016. c. LEED v4 (BD&C [ ID&C ] ) EQ Credit: (1-3 points): Low-Emitting Materials. D. Closeout Submittals: Operation and Maintenance Data, Executed Warranty Documentation, and Record Documents. Edit LEED Requirements below to suit project. 1. Sustainable Design Closeout Documentation: Complete and maintain online USGBC 09 00 50-1

Last Updated: 10/29/2014 SPRAY-LOCK, INC. CHATTANOOGA, TN LEED worksheets for the following credits: a. LEED 2009 EQ 4.1, EQ 4.3 b. LEED v4 (BD&C [ ID&C ] ) EQ 1.4 QUALITY ASSURANCE A. Qualifications: Installer / Applicator with a minimum three (3) years successful experience; and a Testing Agency in accordance with ISO/IEC Standard 17025 or ASTM E699 and ASTM E329. Installer / Applicator qualification requirement recommended for proper substrate preparation for the finish flooring material to be adhered. B. Source Limitations: Obtain spray-applied adhesive through one source from a single manufacturer or a Spray-Lock approved distributor. To find an approved distributor, go to: http://spraylock.com/distributors C. Sustainability Standards and Certifications: Edit sustainability standards and certifications below to suit project. 1. Adhesive and Sealant VOC Limits: According to Green Seal GS-36 for aerosols. 2. VOC Limits: As tested using U.S. EPA Reference Test Method 8260B. 3. General Emissions Evaluation: Use California Department of Public Health (CDPH) Standard Method v1.1 2010, using the applicable exposure scenario (mg/m 3 ). Benchmark mockup requirement recommended to test substrate preparation, workmanship, and compatibility between finish flooring material and adhesive. D. Benchmark Installations: Provide on site mockup installations to verify final selections made under sample submittals and prototypes, to demonstrate aesthetic effects and set quality standard benchmarks for materials and execution. 1.5 DELIVERY, STORAGE, AND HANDLING A. Delivery, Storage and Handling in accordance with manufacturer s written recommendations, industry guidelines, and DIVISION 01 requirements. 1.6 FIELD CONDITIONS A. Conditions and Measurements: 1. Visit jobsite to verify installation conditions and floor measurements. 2. Ambient Conditions in accordance with manufacturer s written recommendations, DIVISION 01, and as follows: 1.7 WARRANTY a. New concrete slabs to be flat, clean and dry meeting all moisture tests passing manufacturer s written requirements. b. Environmental Limitations: Maintain temperature and RH in accordance with manufacturer s recommendations. c. Conditioning: Acclimate floor finish materials a minimum 48 hours in advance of installation. A. Provide Spray-Lock Flooring Adhesive Manufacturer s: 1. Material and Workmanship Warranty: a. Aerosol (22oz) Flooring Adhesive to be free from defects for a period of three (3) years from date of manufacture. 2. Delamination Warranty that there shall be no delamination failure: 09 00 50-2

a. Due to adhesive failure for a period of five (5) years from date of installation. b. As long as moisture vapor emissions do not exceed 90% RH (for Spray-Lock Standard Adhesives) or 95% RH (for Spray-Lock Platinum Adhesives), when tested in accordance with ASTM F2170 c. For moisture in concrete slab conditions up to 8 lbs. (for Spray-Lock Standard Adhesives) or 10 lbs. (for Spray-Lock Platinum Adhesives) per 1,000 sf per 24 hours, when tested with a prepackaged calcium chloride crystal kit performed in accordance with ASTM F1869. d. For concrete slab conditions up to a ph of 11 (for Spray-Lock Standard Adhesives) or 12 (for Spray-Lock Platinum Adhesives) when tested in accordance with ASTM F710. PART 2 - PRODUCTS 2.1 MANUFACTURERS / FABRICATORS A. Manufacturers List: Subject to compliance with requirements, provide spray adhesive products by one of the following: 1. Spray-Lock, Inc., 5959 Shallowford Road, Suite 405, Chattanooga, TN 37421; 423.305.6151; 423.305.6150 (fax); www.spraylock.com 2. Substitution Limitations: Manufacturers of equivalent products beyond those listed above shall be considered when submitted in accordance with DIVISION 01, using CSI Substitution Request Form 1.5C (During the Bidding Phase) or Form 13.1 (After the Bidding Phase.) B. Product Options: For information on Spray-Lock products visit: http://spraylock.com/adhesives 2.2 DESCRIPTION A. Spray-Lock Spray Adhesive is an aerosol water-based aerosol adhesive that: Acts similar to pressure sensitive adhesives; contains less than 0.02 g/ml VOC; is non-flammable; and is a non-hap that emits no dangerous fumes or odors. B. Sustainability Characteristics 1. USGBC LEED Rating: Comply with project requirements intended to achieve the following Rating, as measured and documented according to the USGBC LEED Green Building Rating and Version indicated: Each LEED Version requires a different credit total to achieve the desired LEED Rating. NOTE. Select one of the following Ratings and edit the Version listed to suit your project: a. Rating: Certified, Silver, Gold, or Platinum b. Version: LEED 2009-NC v. 3 (New Construction) c. Version: LEED v4 - BD&C (Building Design and Construction) 2. Applicable LEED Credits: Performance requirements of the following LEED Categories and Credits apply to this Section are met as follows: a. Indoor Environmental Quality (EQ): 1). LEED 2009 IEQ Credit 4.1, Low-Emitting Materials: Adhesives and Sealants: as applied to Spray-Lock adhesives. a). Green Seal GS-36 requires a VOC limit of 70 g/l for Aerosol Adhesives, 65 g/l for Mist Spray Adhesives and 55 g/l for Web Spray Adhesives. b). Spray-Lock Flooring Adhesive tested VOC is 0.02 g/ml using EPA Method 8260B. 2). LEED 2009 IEQ 4.3: Low Emitting Materials, Carpet and Resilient Flooring Systems, CRI Green Label a). Spray-Lock Adhesives comply with the CRI Green Label Plus; See certificate 09 00 50-3

Last Updated: 10/29/2014 SPRAY-LOCK, INC. CHATTANOOGA, TN #GLP 60255 NOTE. Select either a. LEED 2009 or b. LEED v4, deleting the one not used. 3). LEED v4 (BD&C) EQ Credit (1-3 points): Low-Emitting Materials at least 90%, by volume, for emissions, and 100% for VOC content. a). General Emissions Evaluation in accordance with CDPH v1.1-2010. b). Spray-Lock Flooring Adhesive tested VOC is 0.02 g/ml in accordance with EPA Method 8260B. C. Accessories: Spray-Applied Adhesive with aerosol container holder/dispenser accessory as recommended by the adhesive manufacturer. PART 3 - EXECUTION 3.1 EXAMINATION, PREPARATION, AND INSTALLATION A. Examination, preparation, and installation in accordance with floor finish assembly product manufacturer s and adhesive manufacturer s written instructions, industry guidelines, DIVISION 01, and as follows: 1. Acceptance of Conditions: Carefully examine installation areas with Installer/Applicator present, for compliance with requirements affecting Work performance. a. Verify that field measurements, surfaces, substrates, structural support, tolerances, levelness, plumbness, temperature, humidity, moisture content level, cleanliness and other conditions are as required by the manufacturer, and ready to receive Work. b. Test substrates as required by manufacturer to verify proper conditions. c. Proceed with installation only after unsatisfactory conditions have been corrected. 2. Provide and prepare substrates to ensure proper adhesion of flooring system in accordance with spray-adhesive manufacturer s instructions. a. Sweep or vacuum, and damp mop clean flooring substrates immediately prior to sprayapplied adhesive installation. 3. Spray-Applied Adhesive Method: a. Mark floor equivalent to manufacturer s recommended area for size of container used. Apply no more or less adhesive than what manufacturer recommends. b. Outline perimeter of the room with a band of adhesive. c. Lay flooring finish material, adjust and reset until layout placement is certain. d. Roll entire floor area with a 75 to 100 lb (34 to 45 kg) roller to ensure proper bonding with instant shear strength. 4. Close space to traffic for 2 hours before beginning installation. Flooring to be immediately available after rolling for all range of use. 3.2 FIELD QUALITY CONTROL A. Site Tests and Inspections in accordance with DIVISION 01, and as follows: 1. Inspect floor finish system installation for non-conforming work including, but not limited to, lack of adequate adhesion, adhesive overspray, and improper substrate preparation. 3.3 CLEANING A. Waste Management in accordance with DIVISION 01, and as follows: Store and recycle cartons and aluminum adhesive containers. 3.4 CLOSEOUT ACTIVITIES A. Perform Closeout Procedures in accordance with DIVISION 01, and as follows: 09 00 50-4

1. Substantial Completion Requirements. 2. Perform required Demonstration and Training with Owner s designated staff. 3. Sustainable Design Closeout Documentation: Online LEED credit worksheets. B. Correct Non-Conforming Work in accordance with General Conditions, and the acceptance of the Architect. END OF SECTION Be sure to obtain the latest version of this Guide Specification. This Guide Specification is not a completed document ready for use. It must be edited, deleting, adding, or modifying text, as required to suit project requirements. The professional stamping and the contracting parties of the Contract Documents are responsible for the accuracy of issued project specifications, including any use of this SPRAY-LOCK Guide Specification. SPRAY-LOCK, INC. SHALL NOT BE LIABLE FOR DAMAGES ARISING OUT OF THE USE OF THIS GUIDE SPECIFICATION. 09 00 50-5