SNAP-CLAD. Technical Information and Flashing Details. /

Similar documents
PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SL175 Panel Technical Data Guide

Specifications for FL-100 Soffit Panel

Design: Stuart Cohen & Julie Hacker Architects Photo: Tony Soluri Photography

SHEET METAL ROOF TEST REPORT

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

TRIAD CORRUGATED METAL, INC.

SL150 Guide Specification

Through-Fastener Panel UL Listing documentation

LUX Specifications. Section S - Preformed Steel Siding

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Alply CLASSIC WALL Architectural Insulated Panel Wall System

March 26, 2017 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

DAN S CUSTOM SHEETMETAL Manufacturer and Distributor

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION MANUFACTURED ROOF AND WALL PANELS SECTION SHEET METAL ROOFING

Sapphire Metal Tile Roofing System

SECTION ALUMINUM STORM WINDOWS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Metal Roof Panels

ALLMET CONTINENTAL INSTALLATION GUIDE

LP SmartSide Perfection Shingle

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

Prestige Series Guide Specifications

MS-100 MS-150. MS SERIES Flashing and Details Guide. MS150 Flashing and Details Guide. MS200 Flashings and Details Guide

TECHNICAL INFORMATION

Three Great Steel Panels

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal March 1, 2015

Guide Specification SDP 200

SECTION METAL BUILDING SYSTEMS

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

DIVISION 7 METAL WALL AND ROOF SYSTEMS STANDARD STOCKED ARCHITECTURAL COLORS

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

S BI COM P ON E NT CA T ALOG

SECTION ALUMINUM WINDOWS

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

BEARING METAL STUD FRAMING

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

KS SERIES - VERTICAL INSTALLATION

by Rollfab Metal Products

Architectural Metal. custom fabrication for curtainwall and storefront applications

Corium Brick Rainscreen System Specifications

INSULATED PANEL OVERVIEW

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

Prestige Roofing System

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

LP OSB Sheathing & Structural 1 Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

Specifications. Materials and Fabrication. Physical Properties. Environmental Impact. Sizes. Installation - General Requirements.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

PBR & PBU PANELS. Technical/Installation Information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

DuPont RainVent Batten Installation Guidelines

Fascia Systems S. Old Peachtree Rd Norcross, GA (800) Copyright 2010, Innovative Metals Company, Inc.

WATERPROOFING TAMKOWATERPROOFING.COM

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

Built to Last a Lifetime

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

MultiLok-24 Guide Specifications conforming to C.S.I. standards. A Division of ASC Profiles

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

SECTION TURBINE VENTILATORS

PROJECT STATEMENT OF WORK ROOFING PHASE AREA CAMP BLANDING JOINT TRAINING SITE STARKE, FL 32091

/BUT BuyLine BUtler roof systems ROOF SYSTEMS DESIGN AND SELECTION GUIDE

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION CONCRETE ROOF TILE

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

Non Structural Metal Roofing Systems. Structural Metal Roofing Systems. Curved Panel Systems. Wall Panel Systems. Soffit Systems.

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Steelway Building Systems. Product Specifications Guide

Span-Lok hp, Curved Span-Lok, & SpanSeam

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

The GlasRoc Shaftliner Type X advantage...

SLATE ROOFING INSTALLATION PROPOSAL [Last updated 10/08/2017]

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Scope. Definitions. For definitions of terms used in this application standard, refer to ASTM 1079 and the Florida Building Code, Building.


REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

Metl-Span ThermalSafe Insulated Metal Wall and Ceiling Panels

Gold Bond BRAND Gypsum Sheathing

STILE. Panel Information. Design/Installation Considerations. Flashing Profiles. Detail Conditions. Notes. Accessory Profiles. Testing Information

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Transcription:

SNAP-CLAD Technical Information and Flashing Details

Product Information: PAGE 3 SNAP-CLAD Spec. Sheet PAGES 4-13 UL List Cards - UL Construction Numbers 261, 254, 255, 263, 343, 303, 508, 508A, 614, 790 PAGE 14 UL Construction Code Miami-Dade/Florida Product Approvals PAGES 15-38 PAGES 39-42 SPEC-DATA Sheet PAC, Petersen Aluminum Corporation reserves the right to discontinue products at any time or change specification and/or designs without notice and without incurring obligation. Application details are for illustration purposes only, and may not be appropriate for all environmental conditions, building designs, or panel profiles. Projects should be engineered to conform to applicable building codes, regulations, and accepted industry practices. Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. Petersen Aluminum Corporation does not build or design buildings. It acts solely as a supplier of materials, and assumes no responsibility for the proper use or installation of those materials, nor for the suitability of those materials for any specific use or for compliance with local building codes. 2

SNAP-CLAD sealant bead (optional) 1-3/4" 10", 12", 16" or 18" O.C. SNAP-CLAD 10, 12, 16 or 18 O.C..032 aluminum 1-3/4 high.040 aluminum 24 gauge steel 22 gauge steel 16 oz. copper U.L. Construction Numbers 261, 254, 255, 343, 303, 508, 508A, 614 SNAP-CLAD Panels feature architectural panel aesthetics as well as structural panel performance. These panels carry a U.L. rating over a wide variety of assemblies as indicated by the above listed U.L. Construction numbers. Features: Requirements:.032 aluminum,.040 aluminum, 24 ga. steel, or 22 ga. steel, 16 oz. copper (Standard Colors are limited in 22 ga. steel &.040 aluminum) 10 o.c., 12 o.c., 16 o.c., 18 o.c. Factory Applied Sealant Bead in Seam (Optional) Tension Leveled Available Smooth, with Stiffening Beads or with Striations Factory Eave Notching Solid Substrate, Open Framing, or Rigid Insulation Vapor Barrier (on solid substrate and rigid insulation) Clips (U.L. 90 Clip or Standard Clip) Bearing Plates: Required when used in assembly including rigid insulation over metal decking. Minimum Roof Pitch: 2 on 12 (If less than 2 on 12, contact our factory.) SNAP-CLAD Finish: Air & Water Infiltration Tested: PAC-CLAD (Kynar 500 or Hylar 5000 ) ASTM E283/1680 and E331/1646 Miami-Dade NOA & Florida Approvals: Note: Petersen Aluminum s Snap-Clad Panel is thoroughly tested to meet the requirements of Miami-Dade and the Florida Building codes. Please refer to our website, www.pac-clad.com, for specific NOA & Florida Building Approvals available by gauge and building assembly. When a U.L. Rating is required, Petersen Aluminum Corporation must be notified prior to fabrication of the panels. 3

UL Construction No. 254 Wind-Uplift - Class 90 (See Item No. 4) / Fire Not Investigated UL Construction No. 254 1 2 3 4 Metal Roof Deck Panels* Snap-Clad Roof Deck Fasteners* (Panel Clips) Snap-Clad Clip Panel Fasteners (Screws) Purlins No. 22 MSG or No. 24 MSG min. thickness coated steel panels. Panels 12 in. wide max., 10 in. wide min. 1-3/4 in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip located at each purlin intersection. Fasteners used to attach panel clips (item 2) to purlins to be No. 10-16 by 1 in. long No. 3 self-drilling point, No. 2 Phillips drive head, cadmium plated steel screws. Two screws per clip to be used, inserted through 1/4 in. diameter guide holes. No. 16 MSG min. thickness steel (50,000 psi min. yield strength). Spacing: For 22 MSG thickness panels - 60 in. OC For 24 MSG thickness panels - 48 in. OC *Bearing the UL Classification Marking 4

UL Construction No. 255 Wind-Uplift - Class 90 and 60 (See Item No. 4) / Fire Not Investigated 1 2 3 4 Metal Roof Deck Panels* Snap-Clad Roof Deck Fasteners* (Panel Clips) Snap-Clad Clip Panel Fasteners (Screws) Purlins No. 24 MSG min. thickness coated steel. Panels 18 in. wide max., 10 in. wide min. 1-3/4 in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip located at each purlin intersection. Fasteners used to attach panel clips (item 2) to purlins to be No. 10-16 by 1 in. long cadmium plated pancake head No. 2 phillips drive, No. 3 self-drilling point steel screws. Two screws per clip to be used inserted through 1/4 in. diameter guide holes. No. 16 MSG min. thickness steel (50,000 psi min. yield strength). Spacing for Class 90 to be 48 in. OC: For Class 60 to be 60 in. OC UL Construction No. 255 *Bearing the UL Classification Marking 5

UL Construction No. 261 Wind-Uplift - Class 90 or 60 (See Item No. 4) / Fire Not Investigated UL Construction No. 261 1 2 3 4 Metal Roof Deck Panels* Snap-Clad Roof Deck Fasteners* (Panel Clips) Snap-Clad Clip Panel Fasteners (Screws) Purlins 0.032 in. thick aluminum or No. 24 MSG min. thickness coated steel. Panels 10 in. wide. 1-3/4 in. high at the ribs. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints. One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip located at each purlin intersection. Fasteners used to attach panel clips (Item 2) to purlins to be No. 10-16 by 1 in. long cadmium plated, pancake head, No. 2 phillips drive, No. 3 self-drilling point. Two screws per clip to be used, inserted through 1/4 in. diameter guide holes in clip base. No. 16 MSG min. thickness steel (50,000 psi min. yield strength). Spacing for aluminum panels: For Class 90 to be 36 in. OC. For Class 60 to be 48 in. OC. Spacing for steel panels: 22 MSG thick to be 60 in. OC. 24 MSG thick to be 48 in. OC. *Bearing the UL Classification Marking 6

UL Construction No. 303 Uplift - Class 90 / Fire Not Investigated 1 Metal Roof Deck Panels * / Snap-Clad No. 24 MSG min thickness coated steel. Panel width 18 in. max., 10 in. min., 1-3/4 in. high at the ribs. A bead of sealant may be used at panel side joints. 2 3 4 5 6 A Metal Roof Deck Panels* (Not Shown) 0.032 in. min thick aluminum, 16 in. wide max, 10 in. wide min, 1-3/4 in. high at the rib. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, 3-1/2 in. wide, 1-7/8 in.. high. Clip spacing to be 48 in. max. OC for steel panels and 18 in. max. OC for aluminum panels. Clips to interface with Item 2A (bearing plate). A Bearing Plate* (Not Shown) To be used with Snap-Clad Clips only (Item 2). To be 24 MSG thick coated steel, nom 4-5/8 in. wide by 6 in. long. Panel Fasteners (Screws) Fasteners used to attach panel clips and bearing plates (Items 2 & 2A) through rigid insulation and optional OSB and/or gypsum board and into light gauge steel deck (Item No. 5) to be No. 14 truss head type with No. 3 Phillips drive, self-drilling steel screws. Two screws per clip to be used, inserted through 1/4 in. diameter guide holes. Fasteners to penetrate liner panel 3/4 in. min. Foamed Plastic (Rigid Insulation) Min thickness 1 in., max thickness 4-1/2 in. Density to be a min of 1.8 pcf. A B Oriented Strand Board (OSB) (Optional) (Not Shown) Located over foamed plastic (Item 4). Max thickness 7/16 in. Note: Bearing plates not required when OSB is used. Gypsum Board (Optional) Max thickness 5/8 in. Located over liner panel (Item 5). Liner Panel Min thickness No. 22 MSG. Coated steel (33,000 psi) min yield strength min. depth 1-1/2 in., max. pitch 6 in., fabricated to various profiles. Underlayment (Not shown) One ply of 30 lb roofing felt or one layer of bituminous resin type water proofing membrane. UL Construction No. 303 7 Supports (Not Shown) Used to support liner panels, spaced per deck manufacturer s specifications for uplift. *Bearing the UL Classification Marking 7

UL Construction No. 343 Uplift - Class 90 / Fire Not Investigated UL Construction No. 343 1 2 3 4 5 Metal Roof Deck Panels* / Snap-Clad No. 24 MSG min. coated steel panels 18 in. wide max., 10 in. wide min., 1-3/4 in. high at the ribs. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips spaced 36 in. OC, max, fastened to plywood deck. Panel Fasteners (Screws) Fasteners used to attach panel clips (Item 2) to plywood to be No. 10-12 by 1 in. long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Min two fasteners per clip to used. Underlayment Underlayment used over plywood deck to be Type 15 or 30 organic felt. Sides overlapped min. 2 in., end laps per manufacturer s instructions. Felt nailed to plywood deck with 1-1/4 in. long steel cap nails, located per manufacturer s instructions. Nail spacing to be max 12 in. OC at the side lap and max 24 in. OC in interior rows. As An Alternate: A self-adhering modified bitumen water proofing membrane may be used, installed per manufacturer s instructions. Note: when alternate is used the plywood joints need not be sealed. Plywood Decking Plywood decking to be graded per PS83 specifications, 19/32 in. thick, exposure 1, APA Rated Sheathing (42/20) square edged, Butt ends not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant applied with a caulking gun and feathered outward from the joint. (Note exception under Item No. 4, alternate.) 6 7 Supports (Not Shown) Spaced max of 24 in. OC. Any of the following types may be used to support the plywood decking: a) Nom. 2 by 6 in., No. 2 grade or better S-P-F, Hemlock Fir, Douglas Fir or Southern Yellow Pine or equivalent. b) Wood trusses with a nom. 2 by 4 in. upper chord of the same grade as item a. c) No. 22 MSG min cold formed coated steel (min. yield to be 33,000 psi). Plywood Fasteners (Not Shown) Fasteners used to attach the plywood deck or OSB to the supports to be as follows: a) For plywood-to-wood supports No. 8-18 by 1-7/8 in. long bugle-head steel screws with a No. 2 Phillips drive, a Hi-Low thread pattern and an S-Point. b) As an alternate to Item a, 8d common nails may be used. c) For plywood-to-steel supports for a steel thickness less than No. 20 MSG No. 7-19 by 1-1/4 in. long bugle-head steel screws with a No. 2 Phillips head drive Hi-Low threads and an S-Point. For a steel thickness greater than No. 20 MSG to No. 16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel screws with a No. 2 Phillips drive and a S12 (TEKS/3)supR point. Spacing: Fastener spacing for all fastener types to be 6 in. OC at the plywood edges and 12 in. OC in the interior. Refer to General Information, Roof Deck Construction (Building Materials Directory) for items not evaluated. *Bearing the UL Classification Marking 8

UL Construction No. 508 Uplift - Class 90 / Fire Not Investigated 16 MAX 1 2 3 4 5 24 MAX Metal Roof Deck Panels* / Snap-Clad 0.032 in. min. thick aluminum; Panels 16 in. wide max., 10 in. wide min., 1-3/4 in. high at the rib. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips spaced 18 in. OC. Panel Fasteners (Screws) Fasteners used to attach panel clips (Item 2) to plywood (Item 5) to be No. 10-12 by 1 in. long, No. 1 Phillips drive, bugle head coated steel wood screws. Two screws used per clip inserted through 1/4 in. diameter guide holes. Underlayment Underlayment used over plywood deck to be Type 30 organic felt. Sides overlapped min. 2 in., end laps per manufacturer s instructions. Felt nailed to plywood deck with 1 in. long galvanized steel roofing nails, located per manufacturer s instructions. Nail spacing to be max 12 in. OC at the side lap and max 24 in. OC in interior rows. As An Alternate: A self-adhering modified bitumen water proofing membrane may be used, installed per manufacturer s instructions. Note: when alternate is used the plywood joints need not be sealed. Plywood Decking Plywood decking to be graded per PS83 specifications, 19/32 in. thick, exposure 1, APA rated sheathing (42/20) square edged, Butt ends not blocked. 6 7 Supports Spaced max 24 in. OC. Any of the following types may be used to support the plywood decking: a) 2 by 6 in., min No. 2 grade A.F.P.A. S-P-F Hemlock Fir, Douglas Fir or Southern Pine or equivalent. b) Wood trusses with a nominal 2 by 4 in. upper chord of the same grade as item a. c) No. 22 MSG min thick cold formed coated steel (min. yield to be 33,000 psi). Plywood Fasteners (Not shown) Fasteners used to attach the plywood deck to the supports to be as follows: a) For plywood-to-wood supports No. 8-18 by 1-7/8 in. long bugle-head steel screws with a No. 2 Phillips drive, a Hi-Low thread pattern and an S-Point. b) As an alternate to Item a, 8d by 2-1/2 in. long deformed shank common nails may be used. c) For plywood-to-steel supports for a steel thickness less than No. 20 MSG, No. 7-19 by 1-1/4 in. long bugle-head steel screws with a No. 2 Phillips head drive Hi-Low threads and an S-Point. For a steel thickness greater than No. 20 MSG to No. 16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel screws with a No. 2 Phillips drive and a S12 (TEKS/3) point. Spacing: Fastener spacing for all fastener types to be 6 in. OC at the plywood edges and 12 in. OC in the interior. Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for items not evaluated. *Bearing the UL Classification Marking UL Construction No. 508 9

UL Construction No. 508A Uplift - Class 90 / Fire Not Investigated 18" MAX. (STEEL) 16" MAX. (ALUM.) UL Construction No. 508A 1 2 3 4 5 Metal Roof Deck Panels* / Snap-Clad No. 24 MSG min. thick coated steel panels, 18 in. wide max., 10 in. wide min., or 0.032 in. min. thick aluminum, 16 in. wide max., 10 in. wide min., 1 3/4 in. high at the rib. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. Clips spaced 36 in. OC max for steel panels and 18 in. OC max for aluminum panels. Fastened to nailable insulation (Item 5). Fasteners (Screws) Fasteners used to attach panel clip (Item 2) to nailable insulation (Item 5) to be No. 10-12 by 1 in. long pancake head, No. 2 Phillips drive, A-point coated steel screws. Min. two fasteners per clip. Underlayment Underlayment used over nailable insulation (Item 5) to be Type 30 organic felt. Sides overlapped min. 2 in. End laps per manufacturer s instructions. Felt nailed to nailable insulation with 1 in. long galvanized steel roofing nails, located in side laps and between side lap per manufacturer s instructions. Nail spacing to be max 12 in. OC at the side lap and max 24 in. OC in interior rows. Nailable Insulation Consisting of 1 in. min. to 3-1/2 in. max thick Classified polyisocyanurate foamed plastic with a factory laminated 7/16 in. thick APA rated O.S.B. Density of foamed plastic to be 2 pcf. 5 7 8 7 8 9 2 1 3 4 5 1.750 NOM. Fasteners (Screws) Fasteners used to attach nailable insulation (Item 5) to liner panel (Item 8) to be No. 11-13, No. 3 Phillips drive, truss head, painted steel screws. Length to depend on overall thickness of deck and to penetrate steel deck 1/2 in. min. A 2 in. diameter formed pressure plate fabricated from No. 22 MSG coated steel to be used with each screw. Fasteners located in three rows along the 8 ft. length of the nailable insulation beginning 6 in. from the 8 ft. edges with a row down the center and spaced 21 in. OC beginning 6 in. from the 4 ft. edges. A total of 15 fasteners used for each 4 by 8 ft. board. Liner Panel (Steel Deck) No. 22 MSG min. thick coated steel. Min. depth 1-1/2 in., max pitch 6 in. fabricated to various profiles. Min. yield strength 33,000 psi. Fastened to supports (Item 6) with fastener type and spacing per liner panel manufacturer s instructions for uplift loading. Gypsum Board (Optional - Not Shown) Max. thick 5/8 in. supplied in 4 by 8 ft. sheets. Butt joints located over crests of metal roof deck panel (Item 1). Fastened to panel with same fasteners used for nailable insulation (Item 5). Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for items not evaluated. 6 Supports (Purlins) Purlins used for liner panel (Item 8) support to be cold formed steel sections. As alternatives, structural steel components (hot rolled beams, channels, open web joists, etc.) may be used. Min. gauge and yield to depend on design considerations for uplift loading with max spacing to be 6 ft. OC. *Bearing the UL Classification Marking 10

UL Construction No. 614 Uplift - Class 90 / Fire Not Investigated 16 MAX 1 2 3 4 5 6 Metal Roof Deck Panels* / Snap-Clad 16 in. wide max., 10 in. wide min., 1-3/4 in. high at the rib, fabricated from 16 oz., half-hard copper. A bead of sealant may be used at panel side joints. Roof Deck Fasteners* (Panel Clips) / Snap-Clad Clip One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. The clips are to be spaced a maximum of 24 in. OC. Panel Fasteners (Screws) Fasteners used to attach panel clips (Item 2) to plywood (Item 5) to be No. 10-16 by 1 in. long, No. 1 in. pancake head coated stainless steel screws. Two screws used per clip inserted through 1/4 in. diameter guide holes. Underlayment* Any UL Classified base or ply sheet, mechanically fastened with nails or staples. A 24 MAX Underlayment: Rosin paper, 9 mil. thick, mechanically fastened with nails or staples. Plywood Decking Plywood decking to be graded per PS83 specification, 19/32 in. thick, Grade B-C, exposure 1, APA rated sheathing (42/20) square edged. All plywood joints to be sealed against leakage with caulk or a one part urethane sealant. Supports Spaced max 24 in. OC. Any of the following types may be used to support the plywood decking: a) 2 by 6 in., min. No. 2 grade A.F.P.A. S-P-F Hemlock Fir, Douglas Fir or Southern Pine or equivalent. b) Wood trusses with a nominal 2 by 4 in. upper chord of the same grade as item a. 7 c) No. 22 MSG min. thick cold formed coated steel (min. yield to be 33,000 psi). Plywood Fasteners (Not shown) Fasteners used to attach the plywood deck (Item 5) to the supports (Item 6) to be as follows: a) For plywood-to-wood supports, No. 8-18 by 1-7/8 in. long bugle-head steel screws with a No. 2 Phillips drive, a Hi-Low thread pattern and an S-Point. b) As an alternate to Item a, 8d by 2-1/2 in. long deformed shank common nails may be used. c) For plywood-to-steel supports for a steel thickness less than No. 20 MSG, No. 7-19 by 1-1/4 in. long bugle-head steel screws with a No. 2 Phillips head drive Hi-Low thread and an S-Point. For a steel thickness greater than No. 20 MSG to No. 16 MSG, No. 6-20 by 1-1/4 in. long bugle-head steel screws with a No. 2 Phillips drive and a S12 (TEKS/3) point. Spacing: Fastener spacing for all fastener types to be 6 in. OC at the plywood edges and 12 in. OC in the interior. Refer to General Information, Roof Deck Construction (Roofing Materials and Systems Directory) for items not evaluated. *Bearing the UL Classification Marking UL Construction No. 614 11

UL Construction No. 790 Class A Coated Steel and aluminum panels identified as Snap-On Standing Seam, High Snap-On Standing Seam, Snap-On Batten, Integral Batten, Redi-Roof Batten, Redi-Roof Standing Seam, Snap-Clad, Integral Standing Seam, Tite-Loc and Tite-Loc Plus. UL Construction No. 790 1 2 3 4 5 6 Deck: Incline: Barrier Board: Ply Sheet (optional): Surfacing: Deck: Incline: Barrier Board: Ply Sheet (optional): Surfacing: Deck: Incline: Barrier Board: Ply Sheet (optional): Surfacing: Deck: Incline: Barrier Board: Ply Sheet (optional): Surfacing: Deck: Incline: Surfacing: Deck: Incline: Barrier Board: Ply Sheet (optional): Surfacing: NC No Limitations 1/4 in. min. Georgia Pacific Corp. Dens-Deck Overlayment Board Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels, mechanically fastened NC No Limitations 5/8 in min. plywood Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel roofing panels mechanically fastened NC No Limitations 7/16 OSB or 5/8 in. plywood over polyisocyanurate insulation board or polyisocyanurate composite board, any thickness Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels mechanically fastened NC No Limitations Polyisocyanurate, glass fiber, perlite or wood fiber, any thickness Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels mechanically fastened NC No Limitations Steel roofing panels mechanically attached to metal purlins C-15/32 No Limitations Georgia Pacific Corp. 1/4 in. (min.) Dens-Deck with all joints staggered a min. of 6 in. from the plywood joints Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace Ice and Water Shield Steel or aluminum roofing panels mechanically fastened 12

UL Construction No. 263 Metal Roof Deck Panels / File R14293 Mechanically Attached Metal Roof Panels 1 2 3 Mechanically Attached Metal Roof Panels For use in Design Numbers: Mechanically Attached Metal Roof Panels For use in Design Numbers: Mechanically Attached Metal Roof Panels For use in Design Numbers: Type Snap-Clad roof deck panels (No. 24 MSG min gauge coated steel or 0.032 min. gauge coated aluminum) placed over specified insulation and/or roof covering for respective designs. Type Snap-Clad panels are secured by Snap-Clad Clips with the upper portion of the clip engaging the panel rib. A 4-1/2 by 6 in. bearing plate fabricated from No. 26 MSG coated steel is used under each panel clip (the bearing plate shall be placed over the specified insulation). Panel clips are attached to the steel deck with No. 14 steel screws having a No. 3 Phillips-drive truss head with an off-set drill-type point. Two fasteners per clip are used. P225, P227, P230, P233, P237, P259, P508, P510, P512, P514, P701, P711, P717, P720, P722, P723, P724, P726, P731, P734, P736, P801, P815, P819 and P821. Types High Snap-On Standing Seam, Snap-On Standing Seam, Integral Batten, Integral Standing Seam, Redi-Roof Standing Seam, Redi-Roof Batten, Snap-Clad, Tite-Loc, Tite-Loc Plus roof deck panels (No. 24 MSG min. gauge coated steel or 0.032 min. gauge coated aluminum) placed over specified insulation and/or roof covering for respective designs. Panels secured to a top layer of 7/16 in. APA-Rated oriented stand board (OSB) laminated to rigid insulation or 5/8 in. plywood over rigid insulation. Panels secured to oriented strand board or plywood at side ribs with panel clips designed specifically for these panels. Panel clips spaced 18 in. OC using No. 10 by 1-1/4 in. long self-drilling, self tapping wafer head. Zinc-plated carbon steel screws. The oriented strand board laminated insulation or plywood covered rigid insulation are mechanically fastened to steel roof deck and covered with a 30 lb. felt. P225, P227, P230, P233, P237, P259, P263, P508, P510, P512, P514, P515, P701, P711, P717, P720, P722, P723, P724, P726, P731, P734, P736, P801, P815, P819 and P821. Types Tite-Loc and Tite-Loc Plus roof deck panels (No. 24 MSG min. gauge coated steel or 0.032 min. gauge coated aluminum) placed over specified insulation and/or roof covering for respective designs. Both types secured to hat sections+ or bearing plates++ with panel clips designed for the particular panel. P225, P227, P230, P233, P237, P508, P510, P512, P701, P711, P715, P717, P720, P722, P724, P726, P731, P734, P736, P801, P815, P819, P821 +Hat-shaped member to be a minimum of 16 MSG, 1 in. min. depth. Member to be fastened through the roof insulation to the steel roof deck with No. 14 self-drilling and/or self-tapping fasteners. Spacing to be determined by the structural loading requirements. In addition, any compressible UL Classified glass fiber compressible blanket insulation with or without a vapor retarding facing may be used between the specified roof insulation and the metal roof panels. UL Construction No. 263 ++Bearing plate to be a minimum of 16 MSG. Member to be fastened through the roof insulation to the steel deck with No. 14 self-drilling and/or self-tapping fasteners. 13

UL Construction Code Maximum Clip Spacing Substrates Rigid Insulation Over UL Construction Code Gauge 22 GA 24 GA 0.032 0.040 16 Oz. Copper 1 2 3 10 Width 18, 16, 12, 10 18, 16, 12, 10 10 12, 10 18, 16, 12, 10 18, 16, 12, 10 10 16, 12, 10 16, 12, 10 10 16, 12, 10 16, 12, 10 16, 12, 10 Open Frame Purlins UL 261 (5-0 ) UL 255 (4-0 ) UL 261 (4-0 ) UL 254 (4-0 ) UL 255 (4-0 ) UL 261 (3-0 ) UL 261 (3-0 ) 5/8 Plywood UL 343 (3-0 ) UL 343 (3-0 ) UL 508 (1-6 ) UL 508 (1-6 ) UL 614 (2-0 ) Contact Petersen Aluminum Corporation for complete UL construction assemblies. 22 GA Steel Deck With Bearing Plates UL 508A (3-0 ) UL 303 (4-0 ) UL 303 (4-0 ) UL 508A (3-0 ) UL 303 (1-6 ) UL 508A (1-6 ) UL 303 (1-6 ) UL 508A (1-6 ) For complete information regarding appropriate purlin spacing, contact Petersen Aluminum Corporation directly. Insulation thicknesses varies between 1 and 4-1/2 according to R-value desired. Refer to UL Roofing Materials directly. SNAP-CLAD MIAMI-DADE NOA S & FLORIDA APPROVALS Petersen Aluminum s Snap Clad panel is thoroughly tested to meet the requirements of Miami-Dade and Florida Building codes. Please refer to our website, www.pac-clad.com, for specific NOA s and Florida Building Approvals available by gauge and building assembly. 14

Hip/Ridge Detail 15

Eave Detail 16

Eave Detail 17

Eave Detail 18

Valley Detail 19

Peak Detail 20

Outside Corner Detail 21

Inside Corner Detail 22

Rake Detail 23

Head Wall Detail 24

Pitch Break Detail 25

Gable Detail 26

Fascia/Rake Wall Detail 27

Gutter Detail 28

Sill Detail 29

Fascia to Soffit Transition 30

Fascia to Soffit Transition 31

Gravel Stop/Head Detail 32

Vented Ridge Detail 33

34

35

36

Bearing Plate Assembly 37

38

SPEC DATA Roof & Wall Panels 07 41 00 Petersen Aluminum Corporation 1. Product Name TITE-LOC, TITE-LOC HS and TITE-LOC Plus Mechanically Seamed Panels SNAP-CLAD Standing Seam Panels Snap-On and High Snap-On Standing Seam Panels Redi-Roof and Redi-Roof Batten Standing Seam Panels Integral Standing Seam and Integral Batten Panels Flush Panels PAC-750 and PAC-850 Soffit Panels Exposed Fastener Panels Precision Series Horizontal Wall Panel 2. Manufacturer Petersen Aluminum Corp. 1005 Tonne Rd. (847) 228-7150 (800) 323-1960 Fax: (800) 722-7150 www.pac-clad.com 3. Product Description Basic Use Petersen Aluminum produces a wide variety of wall and soffit panels in addition to a complete line of metal roofing panels. All standing seam panels are corrective leveled. Standing seam, flush, exposed fastener panels and wall and soffit panels are all factory formed in continuous lengths up to 50. Check specific profile for maximum panel length and consult with local factory for longer lengths. Matching flashing and trim can be factory or field formed from PAC-CLAD material. Materials and Finishes PAC-CLAD is a versatile prefinished sheet metal coating (Kynar 500 or Hylar 5000 ) that is applied to G90 galvanized steel, galvalume steel, or prime quality aluminum. Originally developed for use in abrasive environments, PAC-CLAD is ideally suited for roofing, curtainwall, storefront and trim applications. TITE-LOC, TITE-LOC HS and TITE-LOC Plus 24 gauge PAC-CLAD G-90 galvanized steel 22 gauge PAC-CLAD Galvalume steel.032 PAC-CLAD prime quality aluminum.040 PAC-CLAD prime quality aluminum 24 gauge Galvalume Plus SNAP-CLAD Panels 24 gauge PAC-CLAD G-90 galvanized steel 22 gauge PAC-CLAD Galvalume steel.032 PAC-CLAD prime quality aluminum.040 PAC-CLAD prime quality aluminum 16 oz cold-rolled copper 24 gauge Galvalume Plus Snap-On and High Snap-On Panels 24 gauge PAC-CLAD G-90 Galvanized steel.032 PAC-CLAD prime quality aluminum 24 gauge Galvalume Plus Redi-Roof and Redi-Roof Batten Panels 24 gauge PAC-CLAD G-90 galvanized steel 22 gauge PAC-CLAD Galvalume steel.032 PAC-CLAD prime quality aluminum 16 oz cold-rolled copper 24 gauge Galvalume Plus Integral Panels 24 gauge PAC-CLAD G-90 Galvanized Steel.032 PAC-CLAD prime quality aluminum 24 gauge Galvalume Plus Flush Panels 24 gauge PAC-CLAD G-90 galvanized steel 22 gauge PAC-CLAD Galvalume steel.032 PAC-CLAD prime quality aluminum.040 PAC-CLAD prime quality aluminum 24 gauge Galvalume Plus PAC-750 and PAC-850 Soffit Panels.032 PAC-CLAD prime quality aluminum Exposed Fastener Panels 24 gauge PAC-CLAD G-90 galvanized steel 22 gauge PAC-CLAD Galvalume steel.032 PAC-CLAD prime quality aluminum.040 PAC-CLAD prime quality aluminum.050 PAC-CLAD prime quality aluminum 24 gauge Galvalume Plus TYPES TITE-LOC,TITE-LOC Plus and TITE-LOC HS Panels TITE-LOC panels combine structural performance with architectural panel aesthetics. A factory-applied sealant bead offers additional weather resistance. The minimum panel length is 4 (1.2 m). TITE-LOC panels feature a 2 (51 mm) leg height that requires mechanical field seaming after installation. Panels include a concealed fastener floating clip system designed to allow for thermal expansion/contraction. All three panels carry a UL 90 classification over a wide variety of substrates and assemblies, including 5/8 (15.9 mm) plywood, purlins and rigid insulation in conjunction with bearing plates (UL design numbers 90, 176, 180 238B, 437, 449, 451, 452, 487, 616, and 617). TITE-LOC and TITE-LOC HS panels are factory formed to length and field-seamed to a 90 degree lock, while TITE-LOC Plus panels are designed to be field-seamed to a 180 degree lock. TITE-LOC panels are designed for application on roof slopes as low as 1/2:12 pitch. The TITE-LOC seamer is bi-directional, offering labor savings to travel up and down slope. 6:12 roof pitch is the maximum the Tite-Loc seamer will travel upslope. The TITE-LOC Plus seamer runs in one direction only and care should be taken to install panels from left to right to ensure the seamer travels downslope. The seamer will not run up slope on a roof pitch greater than 4:12. The 90 degree TITE-LOC can be fieldcurved to a minimum radius of 20. Contact local factory for more details about curving capabilities. Additional features include: Weathertighness warranty available Available in four panel condition variations, check with local factory for striation and pencil rib availability Corrective leveled SNAP-CLAD Panels Offering architectural panel aesthetics, as well as structural panel performance, SNAP- CLAD panels feature a 1 3/4 (44.5 mm) leg height and a continuous interlock for improved structural performance. A factoryapplied sealant bead provides additional weather resistance. The minimum panel length is 4 (1.2 m). A concealed fastener clip system allows for thermal expansion/contraction while providing extraordinary hold-down strength. Two clips are available: a standard clip for most mansard and fascia applications and a highperformance clip for roofing application and UL 90 rated assemblies. SNAP-CLAD panels carry a UL 90 classification over a wide variety of substrates and assemblies, including 5/8 (15.9 mm) plywood, purlins and rigid insulation in conjunction with bearing plates (UL design numbers 254, 255, 261, 303, 343, 508, 508A, and 614). A minimum slope of 2:12 pitch is recommended on most applications. Additional features include: Continuous interlock Labor-saving one-piece design Striations and factory eave notching Stiffener beads Weathertightness Warranty Available Snap-On and High Snap-On Panels These panels are designed for use in roofing, mansard and fascia applications and should be installed over a waterproofed solid substrate with a minimum 3:12 roof pitch. Factory roll formed in continuous lengths, Snap-On panels are ideal for specification on applications where roof transitions are required. The simplicity of the pan design, SPEC-DATA SPEC-DATA is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. 2007 Reed Construction Data. All Rights Reserved. 39

SPEC-DATA combined with inline tension leveling, provides superior flatness and allows for greater workability onsite. Both panels in steel carry a UL 90 rating for wind uplift when fastened to a solid substrate, including 5/8 (15.9 mm) plywood or OSB laminated to rigid insulation (UL design numbers 351 and 352). This is one of the few UL 90 systems that does not require sealant between plywood boards. The 1 (25.4 mm) Snap-On standing seam panel can now be curved to a concave or convex radius, with a minimum radius of 9 (2.7 m). This panel is ideal for barrel vaults and entranceways. Curved panels must be installed over a waterproofed solid substrate. The High Snap-On profile features a 1 1/2 (38.1 mm) standing seam. Unlike the Snap-On panel, this panel cannot be curved. Additional features include: Stiffener beads available Redi-Roof and Redi-Roof Batten Panels This architectural metal roofing system, which is available exclusively from Petersen Aluminum, may be specified in either batten or standing seam profile and is intended for application over a solid substrate with a minimum 3:12 roof pitch. The minimum panel length is 4 (1.2 mm). Steel Redi-Roof panels carry a UL 90 rating for wind uplift when fastened to a solid substrate, including 5/8 (15.9 mm) plywood or OSB laminated to rigid insulation (UL design numbers 350, 353 and 615). Additional features include: Labor-saving one-piece design Factory eave notching Stiffener beads Integral Standing Seam and Integral Batten Panels PAC-CLAD Integral panels are designed for roofing applications, mansards, canopies and fascia. The one-piece design of the Integral panels minimizes labor and allows for quick and easy installation. The minimum panel length is 4 (1.2 mm). Steel PAC-CLAD Integral panels carry a UL 90 classification for wind uplift when fastened to a solid substrate, including 5/8 (15.9 mm) plywood or OSB laminated to rigid insulation (UL design numbers 346 and 347). Flush Panels PAC-CLAD Flush panels are designed for use in wall, fascia and soffit applications where a flush or flat appearance is desired. A rounded interlock leg and concealed fastening system improve the flush appearance while providing additional strength. These panels are not intended for use in roofing or mansard applications. Panels are factory-formed to length to minimize field cutting. The minimum panel length is 4 (1.2 m). The maximum panel length is 28 (8.4 m). The Flush panels are available with optional stiffening beads, which are recommended for longer panel lengths. One or two beads are available. Flush panels may also be specified for use as soffit panels. The soffit version of this panel is available with venting strips or perforated, in aluminum only, for increased air flow and under eave ventilation. Contact the local factory for venting options. Additional features include: Rounded interlock leg providing improved flush fit PAC-750 and PAC-850 Soffit Panels PAC-750 preformed soffit panels are suitable for both commercial and residential use. PAC-850 soffit panels utilize an innovative hook and grab interlock. Both panels are rollformed of.032 gauge aluminum, and both panels are 12 (305 mm) wide with a vee groove every 6 (152 mm) center-tocenter. They are furnished in continuous lengths up to 20 (6.1 m). Steel is not available in either profile. The PAC-750 and PAC-850 soffit panels can be perforated to allow for airflow and under eave ventilation. Both PAC-750 and PAC-850 can be specified as fully vented, half vented or solid. Petersen Aluminum can provide a soffit J channel as trim to match any of their soffit panels. J channel is available in lengths up to 12 (3.7 m) in matching colors. Additional features include: Perforation available for ventilation (PAC- 750 and PAC-850) Roll-formed to exact lengths Exposed Fastener Panels Petersen Aluminum offers a complete line of exposed fastener panels providing design flexibility, cost-effectiveness and aesthetics. The 7.2 Panel, R-36 Panel and 7/8 Corrugated Panels are ideal for a wide range of building envelope applications including roofs, walls, and linear panels. The R-41, M-42, M-36 and 1/2 Corrugated panels are suitable for wall applications and equipment screens. The exposed fastener panels can also be produced perforated for a variety of exterior projects, such as equipment screens, or interior acoustical applications. Additional features include: Matching screws and rivets Closure strips available Precut short lengths - 2 (0.61 m) minimum Precision Series The PAC Precision Series Horizontal Wall Panels offer design flexibility, bold visual effect, cost effectiveness and easy installation. Two profiles are available: The HWP has a concealed extended screw leg and the HWPC utilizes a clip leg. Both panels can also be installed vertically in some applications, and can be specified as perforated for use in equipment screen applications. Maximum panel length is 35. SIZES TITE-LOC, TITE-LOC HS and TITE-LOC Plus Panels Width - 12, 16, 18 - (305, 406, 457 mm) Height - 2 (51 mm) SNAP-CLAD Standing Seam Panels Width - 10, 12, 16, 18 - (254, 305, 406, 457 mm) Height - 1 3/4 (44.5 mm) Snap-On Standing Seam Panels Width - 12, 18, 19, 20 (305, 457, 483, 508 mm) Height - 1 (25.4 mm) Snap-On Batten Panels Width - 11, 12, 18 (279, 305, 457 mm) Height - 1 1/2 (38.1 mm) High Snap-On Panels Width - 11, 18, 19 (279, 457, 483 mm) Height - 1 1/2 (38.1 mm) Redi-Roof Standing Seam Panels Width - 12, 16, 18 - (305, 406, 457 mm) Height 1 9/16 (40 mm) with offsets, 1 3/8 (35 mm) without offsets Redi-Roof Batten Panels Width - 12 (305 mm) Height - 1 1/4 (32 mm) Integral Panels Width - 11, 12, 18 (279, 305, 457 mm) Height - 1 1/2 (38.1 mm) Flush Panels Width - 7, 11, 12 (178, 279, 305 mm) Height - 1 (25.4 mm) PAC-750 and PAC-850 Soffit Panels Width - 12 (305 mm) M-42 Exposed Fastener Panels Width - 42 (1067 mm) Height - 3/4 (19.1 mm) M-36 Exposed Fastener Panels Width - 36 (914 mm) Height - 3/4 (12.7 mm) R-41 Exposed Fastener Panels Width - 41 (1041 mm) Height - 1 1/4 (31.8 mm) R-36 Exposed Fastener Panels Width - 36 (914 mm) Height - 1 1/4 (31.8 mm) 7.2 Exposed Fastener Panels Width - 36 (914 mm) Height - 1 1/2 (38.1 mm) 1/2 Corrugated Exposed Fastener Panels Width - 40 (1016 mm) Height - 1/2 (12.7 mm) 7/8 Corrugated Exposed Fastener Panels Width - 34.6 (879 mm) Height - 7/8 (22.2 mm) Precision Wall Panels Width 12 or 16 (305, 406 mm) Height 7/8 (22 mm) 40 SPEC-DATA is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. 2007 Reed Construction Data. All Rights Reserved.

FLASHING & TRIM All flashing and trim shall be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032 -.063 gauge as specified) or PAC-CLAD steel (24 gauge G-90 galvanized or 22 gauge galvalume as specified). Vinyl masking is recommended on all fabrication applications where extra handling is expected. NOTE: The strippable film must be removed immediately after installation. COLORS Petersen Aluminum panels are available in the following PAC-CLAD finishes: 24 gauge G-90 galvanized steel 37 stocked colors 22 gauge galvalume steel 13 stocked colors.032 prime quality aluminum 36 stocked colors.040 prime quality aluminum 20 stocked colors.050 prime quality aluminum 29 stocked colors 24 gauge Galvalume Plus also available ACCESSORIES Petersen Aluminum fabricates a wide range of roofing accessories. Coping, gravel stops, gutters and downspouts are all formed from 38 standard PAC-CLAD colors. LIMITATIONS Contact Petersen Aluminum regarding panel limitations as they pertain to your project specifics. 4. Technical Data ASTM International ASTM A653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc- Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process ASTM A792/A792M Standard Specification for Steel Sheet, 55 % Aluminum-Zinc Alloy- Coated by the Hot-Dip Process ASTM B209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen ASTM E331 Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference ASTM E1592 Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference ASTM E1646 Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference ASTM E1680 Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems Underwriters Laboratories, Inc. (UL) UL 263 Fire Tests of Building Construction and Materials UL 580 Standard for Tests for Uplift Resistance of Roof Assemblies UL 790 Standard Test Methods for Fire Tests of Roof Coverings UL 1897 Uplift Tests for Roof Covering Systems UL 2218 Standard for Impact Resistance of Prepared Roof Covering Materials ENVIRONMENTAL CONSIDERATIONS Where possible, Petersen Aluminum products include a high percentage of recycled material, which lowers the environmental footprint. Additionally, PAC products offer a long life span, and are 100% recyclable at the end of their extended service life, which may reduce the solid waste stream. Petersen also offers 29 finishes that are listed with the Cool Roof Ratings Council, 31 finishes that are Energy Star approved, and 29 finishes that have an SRI of 29 or higher for steep slope roofs, for qualification towards credits for LEED s Green Building Rating System. PHYSICAL PROPERTIES TITE-LOC & TITE-LOC Plus ASTM E331/1646 and ASTM E283/1680 SNAP-CLAD - ASTM E331/1646 and ASTM E283/1680 Snap On & High Snap-On - ASTM E331/1646 and ASTM E283/1680 (when applied over a solid substrate) Redi-Roof & Redi-Roof Batten - ASTM E331/1646 and ASTM E283/1680 (when applied over a solid substrate) Integral Panels - ASTM E331/1646 and ASTM E283/1680 (when applied over a solid substrate) Flush Panels ASTM E330 PAC 850 ASTM E330 Precision Wall Series ASTM E330, ASTM E283, ASTM E331, AAMA 501.1-05 Test reports are available to design professionals upon request. 5. Installation PREPARATORY WORK Handle and store products according to manufacturer s recommendations. Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact. Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions recommended by the manufacturer. Verify that site conditions are acceptable for installation. Do not proceed with installation until unacceptable conditions are corrected. METHODS Contact Petersen Aluminum for complete installation information. PRECAUTIONS In coastal applications, Petersen Aluminum recommends that stainless steel clips be used with prefinished aluminum in lieu of prefinished steel. BUILDING CODES Current data on building code requirements and product compliance can be obtained from Petersen Aluminum technical support specialists. Installation must comply with the requirements of all applicable local, state and national code jurisdictions. 6. Availability & Cost AVAILABILITY Contact manufacturer for information on local availability. COST Budget installed cost information can be obtained from the manufacturer upon request. 7. Warranty A full 20-year pro-rated finish warranty is available covering cracking, peeling and color fade on all PAC-CLAD applications. Finish warranty terms for Cardinal Red, Award Blue and Interstate Blue, and all metallic finishes, as well as embossed finishes, vary slightly. Please refer to www.pac-clad.com for further details. 8. Maintenance Maintenance is not required. The panel finish is a member of the Teflon family and is selfcleaning. If cleaning is desired, panels can be washed with mild soap and water followed by a clean water rinse. 9. Technical Services Technical services are available from Petersen Aluminum Corp. and regional architectural representatives. 10. Filing Systems Reed First Source MANU-SPEC Additional product information is available from the manufacturer upon request. SPEC-DATA SPEC-DATA is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. 2007 Reed Construction Data. All Rights Reserved. 41

PAC-CLAD Color Availability SPEC-DATA PAC-CLAD Standard Reflectivity Emissivity 3 Year Exposure SRI* Steel 24ga. 22ga. Aluminum.032.040.050.063 Almond 0.56 0.83 0.57 64 Arcadia Green 0.33 0.84 0.32 33 Bone White 0.71 0.85 0.71 86 Cardinal Red 0.42 0.84 0.41 45 Charcoal 0.28 0.84 0.28 27 Cityscape 0.37 0.85 0.34 39 Colonial Red 0.34 0.85 0.33 35 Dark Bronze 0.27 0.85 0.26 26 Evergreen 0.27 0.85 0.25 26 Granite* 0.36 0.84 0.35 37 Hemlock Green 0.30 0.85 0.31 30 Hunter Green 0.26 0.84 0.26 24 Mansard Brown 0.26 0.84 0.24 24 Medium Bronze 0.30 0.85 0.29 30 Military Blue 0.29 0.84 0.28 28 Musket Gray 0.32 0.84 0.31 32 Patina Green 0.34 0.85 0.33 35 Sandstone 0.51 0.83 0.51 57 Sierra Tan 0.38 0.85 0.35 40 Slate Blue 0.25 0.84 0.27 23 Slate Gray 0.38 0.84 0.37 40 Stone White 0.61 0.86 0.59 72 Teal 0.26 0.85 0.26 24 Terra Cotta 0.37 0.84 0.37 39 PAC-CLAD Metallic Aged Copper 0.27 0.83 0.25 25 Champagne 0.45 0.78 0.41 57 Copper Penny 0.45 0.82 0.42 49 Silver 0.53 0.80 0.51 59 Weathered Zinc 0.27 0.80 0.27 23 Zinc 0.30 0.85 0.30 30 Galvalume Plus** 0.68 0.14 0.55 57 Energy Star PAC-CLAD Standard Colors (do not meet cool roof requirements) Award Blue Berkshire Blue* 0.25 0.84 0.22 23 Burgundy Forest Green Hartford Green Interstate Blue Matte Black Midnight Bronze PAC-CLAD Metallic finishes are available from stock at a moderate extra cost. PAC-CLAD Copper Penny is a Non-Weathering finish. Solar Reflectance Index calculated according to ASTM C-1549. *Low Gloss/Low Sheen,full Kynar 500 or Hylar 5000 finish **Acrylic coated, non-kynar Finish. 42 SPEC-DATA is a registered trademark of Reed Elsevier Inc. The manufacturer is responsible for technical accuracy. 2007 Reed Construction Data. All Rights Reserved.

43