Zero Discharge Treatment Method for Cooling Towers and Heat Exchangers with SP3, I-SOFT-OB, OXYDES & KATALOX LIGHT

Similar documents
COOLING TOWER WATER TREATMENT

COOLING TOWER WATER TREATMENT

White Paper. A Reliable Alternative to Chemicals for Cooling Water Treatment. GWS-1107-D 10/31/11 Copyright 2011 All Rights Reserved

4709 Hwy 36 South, Suite 10 Rosenberg, TX Phone:

Green Technologies to Minimize Cooling Tower Water Use

EXHIBIT A UNIVERSITY OF NEVADA - LAS VEGAS WATER TREATMENT BEST PRACTICES

Cooling Tower Water Management

Cooling Tower Water Conservation: Simple Strategies & Advanced Treatment Eric Elam Water Savers LLC, RTS Water August 15 th, 2017

How can liquid ozone be used in different industries?

Forward Osmosis Applications for the Power Industry

COC = ,000/ (CaH x TA) This discovery is the basis of our unique, patented HighCycle water management products.

Cooling tower efficiency U2 Eco-efficiency resources for the food processing industry

SPECIALIZED WATER TREATMENT

EFFECTIVE USE OF RECYCLED WATER IN COOLING TOWERS WITH NEW GREEN TECHNOLOGY. Abstract

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

THE EDDY WATER MANAGEMENT SYSTEM PRODUCT MANUAL

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER

PRODUCT PROGRAMMING GUIDELINES CHEMICAL GUIDELINES

Technical Service Bulletin

Water Talk. Volume 8, Issue 8 August 2008 Zero Blowdown, Reality or Fantasy? A Critical Look at the Claims and Possibilities

Wastewater Characterization. Tenaska Westmoreland Generating Station

Tech Talk The Importance of Side Stream Filtration in Water and Energy Conservation By Kenn Latzer, Process Efficiency Products, Inc

COOLING TECHNOLOGY INSTITUTE

Lead & Copper Control with Phosphates Darin Skutt Technical Service Manager Carus Corporation

Steamate* technology. superior protection against condensate system corrosion. Water Technologies & Solutions technical bulletin

Operation and Maintenance of Electrochlorination Plant

New Trends for Purification of Industrial Contaminated Water

Cooling Tower Water Treatment. 30A avenue du Pacifique Laval Qc.H7N 3X5 Téléphone

THE WATER MANAGEMENT SYSTEM PRODUCT MANUAL

Laboratory Experiments in Corrosion Engineering II

Breaking new ground in

Beer Line Disinfection System

TRUSTEES OF THE CALIFORNIA STATE UNIVERSITY CALIFORNIA STATE UNIVERSITY, FULLERTON REQUEST FOR PROPOSAL NO ADDENDUM NO. 1

Distribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives

Electricity and Chemistry

WATER SAVING REDUCES TREATMENT OPERATING COSTS ENERGY-EFFICIENT COOLING TOWER

Higher COC and ph Independent Operation of Cooling Water Systems

Watch Water. ANSI/NSF 61 Certified From. February 2014

Chapter 7: Control of Microbial Growth

Important Terminology

Hard water. Hard and Soft Water. Hard water. Hard water 4/2/2012

Water Treatment Program. Training Manual

Forward Osmosis Applied to Desalination and Evaporative Cooling Make-up Water

Bypass filtration in cooling water systems

411 MAXKOOL SS. Maxkool SS does not contain any sulfur, chlorine, nitrites, phenols, Diethanolamine (DEA) or heavy metals.

Cooling Tower Water Savings Stakeholder Meeting #1 - DRAFT California Statewide Utility Codes and Standards Program

Cooling Towers and Environmental Sustainability. Daniel M. Cicero

Worldwide Pollution Control Association

"Significant Cost Savings Obtained Using Advanced Membrane Systems for Cooling Tower Water Treatment and in ZLD plants

Anticorrosive Coatings

SECTION 5 E-Treat Water Conditioning Systems

METALS AND THEIR COMPOUNDS

on-line cleaning of boilers using a novel polymer technology to avoid acid

Legionella Outbreak Prevention for Cooling Towers

Organisation de Coopération et de Développement Economiques Organisation for Economic Co-operation and Development

Environmental Sustainability through the use of Nalco 3D TRASAR Technology for Sea Water Cooling tower

BIOGAS PURIFICATION AND UTILIZATION. ENVE 737 Anaerobic Biotechnology for Bio-energy Production

Pretreatment of Industrial Wastewater for ZLD/Resources Recovery

Wastewater Treatment Additives

TDS AND SLUDGE GENERATION IMPACTS FROM USE OF CHEMICALS IN WASTEWATER TREATMENT

CHANGING THE GAME FOR DESAL

IWC REPORT ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

Overview of Desalination Techniques

BALCLOR TM Ballast Water Treatment System. SunRui Corrosion and Fouling Control Company 3 December 2009, Shanghai China

Concrete Cooling Towers - Salt Water

Thermodynamic Processes

Condensate System Troubleshooting andoptimization

MAINTAINING DRIP IRRIGATION SYSTEMS

ADVANCED SOFTENING MATERIAL FOR PROBLEM WATER

Water for Instrument Processing

Tribology Module4: Lubricants & Lubrication

Concentration mg/l TDS mg/l 10, ,000 Recovery 75% Waste TDS mg/l 44,000 COD mg/l 3,500 0 BOD NTU 1,250 0 Power Used kwh/m3 2.

RECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY

Unit Treatment Processes in Water and Wastewater Engineering

Side Stream Filtration!!

ACUSOL 445/445N/445ND Detergent Polymers for Industrial Machine Dishwash (Warewash)

University of Houston Master Construction Specifications Insert Project Name SECTION WATER TREATMENT SYSTEMS PART 1 - GENERAL

WATER RECYCLING SOLUTIONS

high cycles cooling tower operation using a revolutionary alkaline treatment program Continuum* AEC (Alkyl Epoxy Carboxylate)

Solus* AP - advanced boiler all-polymer internal treatment technology

Plant Utilities and Energy Efficiency CH505

Understanding the Environmental Requirements for Fish

TRASAR TECHNOLOGY A REVIEW AND COMPARISON Cooling Water Feed Control Automation Gary Reggiani and Paul Young

Wastewater Treatment Processes

Is Oxygen Injection the Solution for Your Collection System Odors and Corrosion?

Chemical Testing of Drinking Water

The Control of Microbial Growth

TermoRens Offshore Service as

Copper Corrosion Control

POOL BASIC TYPES ADVANTAGES. Naturally clean water for swimming pools

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

Green Corrosion Inhibition and. (NGC) for Cooling Water Treatment. Report by Dan Duke Water Conservation Technology International

Making the most of cooling water

KR-153SL SOLUTION. GUARANTEE: 2,2-Dibromo-3-nitrilopropionamide 20% COMMERCIAL REGISTRATION NO PEST CONTROL PRODUCTS ACT DANGER

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

Drinking Water Treatment Optimization Tools

Oxygen. Oxygen is one of the fundamental resources required by life forms on Earth. Aquatic ecosystems have a wide assortment of life forms.

Ethylene Oxide Sterilant Alternatives

ACRP. Fact Sheets. On-Site Monitoring Methods AIRPORT COOPERATIVE RESEARCH PROGRAM. Sponsored by the Federal Aviation Administration

Electricide HG Electrochemical Chlorine Generators

Transcription:

Zero Discharge Treatment Method for Cooling Towers and Heat Exchangers with SP3, I-SOFT-OB, OXYDES & KATALOX LIGHT By Deepak Chopra Watch Water GmbH Fahrlachstraße 14 68165 Mannheim Germany May 2013 Web: email: www.watchwater.de info@watchwater.de Telefon: +49 (0) 621 87951-0 Telefax: +49 (0) 621 87951-99 1

Why consider this technology to all traditional chemical water treatment 1) Because Contaminants are destroyed (not separated or concentrated) 2) Because it is the most intelligent thing to do 3) Because there are no toxic chemicals involved 4) Because Instant Dosing Products reduce 95% of water used in conventional water treatment chemicals, which are associated costs for shipping, insurance, handling storage and disposal. 5) To descale systems which have lost heat transfer efficiency, without the need for service companies and dangerous acid cleaning. 6) To reduce the amount of water used in open cooling loop operation and associated costs for supply and discharge of Toxic Chemicals. 7) Eliminate all inorganic, organics, algae, bacteria, fungi including very difficult problems such as yeast and Legionella with the use of very simple biocide I-SOFT OB (Oxidizing Biocide) either as liquid or in the INSTANT powder form 8) To treat water without water softeners where the use of water softeners are forbidden or too costly because of salt and waste water costs. 9) To reduce the amount of sodium chloride (NaCl) in discharge to municipalities 10)It is easy to start up and stop 2

I-SOFT - OB (Oxydizing Biocide) I-SOFT OB: is one of the unique Mixed inhibitor composes of three different types of proprietary formulation that works as 1. Cathodic Scaling prevented 2. Anodic Scaling and Corrosion preventer 3. Oxidizer including adsorption, dispersion and passivation technique used in I-SOFT OB (See more about I-SOFT OB) 3

I-SOFT OXYDES + KATALX LIGHT The unique WATCH strategy of water treatment is to control all 1. Scale 2. Corrosion 3. Biofouling and 4. Filtration only in one process technology without using any harmful chemicals and service and maintenance costs. In this process Cathodic inhibitor (against scale) coats all the cation metals such as making a thin film to prevent free oxygen and water from coming into close contact with the metal surface. I-SOFT breaks the reaction cell and stops the Corrosion rates. ONLY I-SOFT treatment method can be used to stop scale and corrosion problems and to assure efficient and reliable operation on any kind of cooling water systems. 4

I = Cathodic Scale Inhibitor I and SOFT components It is very effective by formation of strong film on all Cathodic corrosion surfaces as to prevent any oxygen attack. It is much more effective than any other inhibitor and very low dosage level is required. Therefore it is the best choice to use in cooling water treatment. "I" does not contain any bicarbonate, metal cations and useless phosphonates or poly phosphates. SOFT = Anodic Corrosion Inhibitor It is capable of forming a protective oxide inhibitor film to cover all the anodic corrosion points inside all the cooling water circulation systems. This method of dosing SOFT is effective to keep all points under protection film and isolate from corrosion initiators like sulfates, chlorides, silicates and nitrates including hydrogen sulfide. Therefore sufficient safety margin shall be applied and should be dosed as to Watch Water Instructions. 20 mg/l should be applied in the feed water. All other hazardous anodic inhibitors like chromates, nitrites, orthophosphates, molybdates are not used in SOFT formulations. 5

I-SOFT I-SOFT as a mixture of three types of inhibitors having the proprietary scale and corrosion inhibitor formula is classified as "MIXED INHIBITOR" category. Since the chemicals used in this formulation have different characteristics supplement to their mutual deficiency, the overall efficacy of the I-SOFT increases. Hence, dosage concentration reduces to half, and this lowers the operating cost of all the cooling towers and environmental impacts caused by phosphates, phosphonates, heavy metals as they are not biodegradable. I- SOFT is 100% Biodegradable. 6

OXYDES Chemistry for Green Biocide: In order to understand the function of I-SOFT OXYDES and KATALOX LIGHT in the cooling water treatment it is helpful to have a basic knowledge of the ISO + KL (Online Learning) involved. Hydroxyl radicals (OH) is one of the Strongest oxidants that is available in Watch Water Chemicals toolbox. OXYDES is extremely reactive and degrades promptly any available organic molecules. Hydroxyl radicals, likewise other reactive oxygen species, are also very POTENT BIOCIDE which vigorously attacks microorganisms and tissues, damaging cell membrane lipids, proteins carbohydrates and RNA/DNA. OXYDES hydroxyl radical reactions are extremely fast, having a rate constant ranging between 10 7 to 10 9 M -1 sec -1. Consequently the OXYDES hydroxyl radicals only diffuses the equivalent of 5-10 times of its molecular diameter before it reacts. 7

Version I Standard Cooling Tower Configuration EVAPORATION Water Spray Heat Exchanger SUMP Makeup Water Feed Water Inlet Pump Watch-DOS System OB Blowdown Standard Cooling Tower Configuration Treating the water for scale and corrosion inhibition with biodegradable biocide. 8

Standard Cooling Tower Configuration (continues from slide 8) All cooling towers functions to cool a circulating stream of water (see figure Version I). The tower acts as a heat exchanger by driving ambient air through falling water, causing some of the water to evaporate (evaporation gives off heat- providing cooling) and then circulates cooled water through whatever equipment needs for cooling. The chemicals used are typically such as chlorine, phosphates, phosphonates, polyacrylates and chelates such as EDTA and NTA to control biological growth, formation of bio-films and to inhibit the scale and corrosion and none of them are biodegradable, thus polluting the environment. I-SOFT OB is a GREEN FORMULATION to control the bio-film and scale formation, which are essential in maintaining cooling tower heat transfer efficiency. 9

Standard Cooling Tower Configuration (continues from slide 9) As the water volume in the tower is reduced through evaporation and drift the concentration of I-SOFT OB increases in the sump. As all cooling towers picks up organic contaminants from ambient air, to maintain chemical and contaminant concentrations at a prudent level, water is periodically removed from the system through a process called "BLOWDOWN" or "BLEED OFF". Blow down water must subsequently be discharged to a local wastewater treatment facility or discharge onsite to the environment. The blow down contains organic materials as well as phosphates, phosphonates or chelates like EDTA or NTA materials. The local wastewater treatment facility will charge extra sewage fees for this polluted water or may not even accept this water. These costs can be quite significant in the overall operation of a tower. cooling 10

ZERO DISCHARGE configuration Discharge of the blow down water to the environment onsite is forbidden and is coming under increasing regulations because of the contaminants like phosphonates, molybdates, chromates, copper, nitrites, orthophosphates are still available in blow down water. Watch has solved all these blow down problems to ZERO DISCHARGE. Watch treats the "makeup" water with FILTERSORB SP3, involving ZERO regeneration salts or chemicals and ZERO Backwash water and ZERO waste water. Dosing I-SOFT OB is circulated back to the makeup water after a UNIQUE combination of I-SOFT OXYDES and KATALOX LIGHT filtration (see Version II, next slide). 11

Version II ZERO DISCHARGE configuration EVAPORATION Water Spray Makeup Water = Evaporation loss + KL backwash water + 5% others loss SUMP Pump Heat Exchanger Time controlled solenoid valve Watch-DOS System Feed Water Inlet Backwash dependent on ph or conductivity control Filtrating the SUMP water once/twice a day, thus saving a significant amount of water from going to waste 12

Benefits of using ISO + KL System The oxygen (O) and hydroxyl (OH) radicals generated in this process will destroy all organics, inorganic and will dissipate quickly and would not be found in the makeup water. The water will be crystal clear and reduce the consumption of chemicals. Only an addition of non-oxidizing biocide is needed to kill Legionella. As a result, huge cost savings accrued from decreased chemicals costs and water use requirements as well as from a ZERO discharge wastewater volume. There are hundreds of benefits to the environment with NO discharge of Hazardous chemicals like phosphates, phosphonates, molybdates, EDTA and NTA compounds and other chemicals discharged. ISO + KL smart systems should require very little maintenance and costing per years compared to conventional chemical or ozone systems. 13

Conclusion There are many references that using FILTERSORB SP3 with a combination of I-SOFT also acts like a de-scaling agents. The premise is that CO 2 oxidizes the biofilm that serves as a binding agent adhering to scale of heat exchangers' surfaces. When scale build-up on condenser is reduced, higher "HEAT TRANSFER" rates are achievable. Increasing the condenser heat transfer rates reduces the chiller head pressure, which then allows the chiller to operate more efficiently and consume less energy. Thanks to FILTERSORB SP3 The Plant friendly Technology We would like to customize a Residential, Commercial or Industrial system to meet your needs. Please contact us at info@watchwater.de END OF PART IV Thanks 14