Ventilated facade design in hot and humid climate. Ventilated facade design in hot and humid climate

Similar documents
Controlling ventilated façades

Great Ocean Rd Ice Creamery

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

INFLUENCE OF HIGH PERFORMANCE FAÇADE ON HEATING/COOLING LOAD IN OFFICE BUILDINGS IN LONDON AND HONGKONG

Solar Energy Technologies

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

Analysis 2: Alternative Thermal Window Design

The Technical Merit of Double Facades for Office Buildings in Cool Humid Climates

Assessment of Climate Change Robustness of a Deep Energy Retrofit Design of an Existing Day Care Centre

Assessment of Indoor Climate: Learning from Buildings

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

Published in: Sichuan - Hong Kong Joint Symposium 2006, Chengdu, June 30 - July 1, 2006.

EFFECTS OF TREES ON THE ROOM TEMPERATURE AND HEAT LOAD OF RESIDENTIAL BUILDING. Tokyo, Japan

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Facade Design for Super High- Rise Building in Subtropic Region in China

ENERGY PERFORMANCE OF DIFFERENT TYPES OF DOUBLE SKIN FACADES IN VARIOUS CLIMATES

PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY

CHP Case Studies. Midwest CHP Application Center (MAC) .org (312) University of Illinois at Chicago Energy Resources Center UIC

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

LOW-ENERGY HOUSING ESTATE SUNDAYS

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Assignment 3 Integrated Energy Design

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Available online at ScienceDirect. Energy Procedia 57 (2014 )

Performance-Risk Methodology for the Design of High-Performance Affordable Homes

Energy Saving Public Swimming Complex In Finland

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Environmental Planning, Energy Efficiency and Renewable Energy Initiatives in Newport, Rhode Island

RENEWABLE ENERGY DESIGN OF TWO HOUSES ENERGETICALLY INDEPENDENT LOCATED AT THETHE PICO S ISLAND (AZORES ISLANDS, PORTUGAL)

Appendix T Renewable Energy Applications on the Green Deck

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

The effect of shading design and control on building cooling demand

Zero Energy Building Example in Estonia. Tõnu Mauring

CAMBRIDGE PUBLIC LIBRARY

A Comparative Analysis On The Effect Of Double- Skin Façade Typologies On Overall Building Energy Consumption Performance In A Temperate Climate

through Early Stage Energy Modeling dl

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Evaluation of Thermal Properties for BIPV Experimental Results of U-value and SHGC for Crystalline Silicone PV Module

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Integration of Energy Efficiency Through Architectural Design. Presentation by TERI. 10 th June,2010

Available online at ScienceDirect. Energy Procedia 48 (2014 )

Sustainable Building Design and Renewable Applications

Energy Efficiency in Kuwait: Past, Current & Future

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

High Performance Buildings for Singapore for Better Energy Management. SERIS Solar Energy Research Institute of Singapore

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

ENERGY SELF SUFFICIENCY WITH RENEWABLE SOURCES BIOMASS AND WIND IN THE REHABILITATION PROJECTOF AN OLD RURAL BUILDING COMPLEX IN SICILY (ITALY)

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

Building Integrated Photovoltaics

Improving the passive building energy efficiency Case study: Office building in Tetuan city in northern of Morocco

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

SOLAR XXI: A Portuguese Office Building towards Net Zero-Energy Building

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

Heating, Cooling, Lighting: Sustainable Design Methods for Architects

Integrated BIPV performance assessment for tropical regions: a case study for Bangalore

Student Modeling Competition

Passive House in Canada: Case Studies on a Near EnerPHit Retrofit and Post-Occupancy Research

A prototype architecture for passive and plus energy building in Estonia

Extended pilot study of an energy efficient glazed office building during pre-design and design. Åke Blomsterberg (WSP och LTH)

COMFORT-PRODUCTIVITY Building costs COMFORT-PERFORMANCE. Radiant Heating and Cooling Systems for Better Comfort and Energy Efficiency INDOOR - OUTDOOR

Developing Solutions for the Environmental Challenges to Deploying PV Plants in Desert Areas

Efficient utilization of energy sources

How to Design Zero Emission Buildings

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

VELUX A/S, Daylight Energy and Indoor Climate, Ådalsvej 99, 2970 Hørsholm, Denmark *Corresponding author:

MODELLING THE IMPACTS OF NEW UK FUTURE WEATHER DATA ON A SCHOOL BUILDING

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

Potential of ventilative cooling in German residential buildings

Bioclimatic chart analysis in three climate zones in Cyprus

OVERALL PERFORMANCE OF VENTILATED DOUBLE FAÇADES COMPARED TO A STATE OF THE ART SINGLE SKIN FAÇADE

SAMPLE ZNE PRESENTATION

Building performance analysis for double skin residential buildings ABSTRACT BACKGROUND. Porooshat Akhgari

European Cooperation in the field of Scientific and Technical Research. Building Integration of Solar Thermal Systems TU1205 BISTS

ESCI-61 Introduction to Photovoltaic Technology

NZEB: The new challenge of HVAC Manufacturers. ASTRO Tower (Archi Urbain)

Principles of Ventilation and Air Conditioning Design & Installation

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Modeling and analyzing solar cooling systems in Polysun

Energy and Thermal Comfort Management in a Kindergarten School Building in the South of Portugal in Winter Conditions

The optimization of the mechanical night cooling system in the office building

Ventilation and Airtightness, different relationship for different quality of buildings

Efficient cooling in a natural and energy-saving way. Large volume flows of outside air provide cooling. Intelligent control

Thermal Comfort in Architecture

Italcementi Center for Research and Innovation

Energy Efficient Buildings in Germany An Introduction

Work Package 2: Performance of naturally ventilated buildings

Experimental investigation of zero energy office under natural and forced ventilation

THERMAL CHARACTERISTICS AND ENERGY CONSERVATION MEASURES IN AN INDOOR SPEED-SKATING ARENA

OPTIMIZATION OF ICE THERMAL STORAGE SYSTEM DESIGN FOR HVAC SYSTEMS

Adaptive buildings' facades for thermal comfort in hot-humid climates

Green Building Guideline of Jordan

THE ENERGY BEHAVIOUR OF THE RESIDENTIAL BUILDING STOCK IN CYPRUS IN VIEW OF THE ENERGY PERFORMANCE OF BUILDINGS DIRECTIVE IMPLEMENTATION

IRP 101. Intro to Integrated Resource Planning. Scott Benson Manager, Resource & Transmission Planning. March 23, 2017

5.0 Daylighting Analysis (Breathe Study)

Green Building Guideline of Jordan

Transcription:

Ventilated facade design in hot and humid climate Matthias Haase Dr. Alex Amato Department of Architecture Faculty of Architecture The Hong Kong University Pokfulam Road, HK, China September 2006 Ventilated facade design in hot and humid climate Background Principles Case studies Simulation Analysis Results Conclusions 1

Background Need for sustainable development Key role of Building industry Energy consumption (world-wide) Transport Building Industry Image credits: Behling, S. Sol power - The evolution of Solar Architecture, 1996, Prestel Background Energy responsible approach Energy consumption (Hong Kong) Building Transport Industry Edited by Mat Haase, Image credit: http://www.emsd.gov.hk 2

Background Energy in buildings in HK Energy consumption (Hong Kong) Commerci al 34% Transport 36% Residential 18% Industry 12% Edited by Mat Haase, Image credit: http://www.emsd.gov.hk Background Energy in buildings in HK Energy consumption in office Buildings in HK Transport, Energy consumption (Hong Kong) Sanitary, others 21% Air-con 47% Lighting 32% Air-con 16% Lighting 11% Transport Transport, Sanitary and others 7% Residential Industry 27% of energy in HK is consumed by Aircon and Lighting in commercial buildings Edited by Mat Haase, Image credits: http://www.emsd.gov.hk and http://arch.hku.hk/research/beer/besc.htm 3

Background Possible integrated functions Daylight Ventilation Sun protection/ shadowing Acoustic protection Façade technology Photovoltaics Insulation Heating/cooling Passive solar Background New concepts for sustainable buildings Double-skin facades for office buildings left: Multimedia Center, Hamburg, Germany by Foster and Partners right: Uni, Erlangen, Germany by UBA Erlangen Image credit: http://www.fosterandpartners.com 4

Background Why double-skin façades? 55.6% Peak cooling load of office building in HK Lam, J. C. and Li, D. H. W. (1999) An analysis of daylighting and solar heat for cooling-dominated office buildings. Solar Energy, 65, 251-262. Background Why double-skin façades? Reduction of peak wind pressure Improvement of energy efficiency of façade by passive solar heat gain in winter reducing thermal losses in winter reducing overall solar heat gain (in summer) support of natural ventilation (with the stack effect) 5

Background Why double-skin façades? Improving comfort Thermal: - predicted mean vote (PMV) - percentage people dissatisfied (PPD) - draft temperature Visual: - daylight factor - glare - view Acoustic: - intrusive noise Image credits: Thermal comfort, INNOVA AirTec instruments and MatHaase Main Type Background Classification of double-skin façades (DSF) Box window facade Corridor facade Shaft-box window facade Multi-storey facade Cavity ventilation natural hybrid mechanical Airflow concept Supply air Exhaust air Static air buffer External air curtain Internal air curtain Haase, M., Amato, A., (2005), Double-skin facades for Hong Kong, proceedings of the Fifth International Postgraduate Research Conference in the Built and Human Environment, The University of Salford, UK. 6

Principles of DSF Principles of airflow in cavity open not open ext. int. ext. int. int. ext. int. int. Exhaust air Supply air Static air buffer External air curtain Internal air curtain Haase, M., Amato, A., (2005), Double-skin facades for Hong Kong, proceedings of the Fifth International Postgraduate Research Conference in the Built and Human Environment, The University of Salford, UK. Background Qout Heat transfer Radiation Q 12 =? A 1? 12?T 14 - T 24 ) primary facade Transmission Second glass layer Conduction Q =??A ( T 1 - T 2 ) / t Reflexion Convection Q = h c A? T Traditional performance criteria U-value, SHGC, meaningless Absorption N 1 Conduction and Convection Qin N 2 7

Background Building design concept Building energy consumption Energy conservation 2 1 Increasing efficiency 3 Utilization of renewable energy resources Haase, M. and Amato, A., (2005), Development of a double-skin facade system that combines airflow windows with solar chim neys, proceedings of Sustainable Building Conference (SB05), Poster session, Tokyo, Japan. Background Energy conservation 35 8000 30 7000 25 6000 degrees C 20 15 5000 4000 3000 degree hours 10 2000 5 1000 0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 0 min/max temperature heating degree hours solar excess degree hours cooling degree hours 8

Climate analysis Psychrometric Chart Location: Hong Kong, China Frequency: 1st January to 31st December Weekday Times: 00:00-24:00 Hrs Weekend Times: 00:00-24:00 Hrs Barometric Pressure: 101.36 kpa A.J.Marsh '00 AH 30 Abs. Humidity [AH] 25 20 15 10 Comfort 5 DBT( C) 5 10 15 20 25 30 35 40 45 50 Dry bulb temperature [ C] Climate analysis Selected Psychrometric Chart Location: Hong Kong, energy China conservation Weekday Times: 00:00-24:00 Hrs Weekend Times: 00:00-24:00 Hrs design Barometric Pressure: 101.36 kpa A.J.Marsh '00 strategies Frequency: 1st January to 31st December SELECTED DESIGN TECHNIQUES: 1. exposed mass + night-purge ventilation 2. natural ventilation 3. direct evaporative cooling 4. indirect evaporative cooling AH 30 25 20 15 10 Comfort 5 DBT( C) 5 10 15 20 25 30 35 40 45 50 9

Climate analysis Case studies Case studies of existing DSF in Hong Kong: 1. Dragon Air office building, Lantau 2. Kadoorie Biological Science Building, HKU 3. Science Park (Phase 1), Pak Shek Kok 4. Governmental offices, Shatin 5. No. 1 Peking Road, Kowloon 6. New emsd hq, Kai Tak 10

Case studies Double-skin façade (external air curtain) Double-skin cavity acts as external shading device Sealed façade with cavity externally naturally vented (as in Dragon Air office and in Science Park) Image credit: Meinhardt Facade Technology Case studies Example of DSF with EAC: Dragon Air office building by Wong Tung & Ptns. Image credit: www.draigonair.com and Meinhardt Facade Technology 11

Case studies Example of DSF with EAC: Science Park (Phase 1) by Simon Kwan Building here: with PV integrated Case studies Example of DSF with EAC: Kadoorie Biological Science building by Leigh & Orange Building here: with HVAC system components in cavity 12

Case studies Airflow window (internal air curtain) Shatin Govermental Offices No. 1 Peking Road New emsd hq one room Image credit: Meinhardt Facade Technology Case studies Airflow window (internal air curtain) Heat is concentrated in cavity 10% exhaust air: savings in overall cooling energy possible AHU Visible glass Second glass layer Improving thermal comfort Exhaust air 13

Case studies Example of AFW with IAC: Shatin Governmental Office by ASD Active window (developed by Meinhardt Façade Technology) Image credits: HK Construction Ltd http://202.66.146.82/listco/hk/hkconstruction/ annual/2001/sum.pdf Case studies Example of AFW with IAC: No. 1 Peking Road by Rocco Ltd Active façade system (developed by Permasteelisa Group) Image credit: Permasteelisa and Mat Haase 14

Case studies Example of AFW with IAC: New emsd hq by ASD 2 upper storeys Refurbishment Image credit: emsd and Mat Haase Simulation double-skin facades basecase DSF AFW 15

Simulation double-skin facades basecase DSF AFW AHU External glass layer Internal movable blinds External glass layer Internal movable blinds Internal glass layer External glass layer Internal movable blinds Internal glass layer Spandrel panel Simulation Thermal building simulation coupled with airflow simulation DSF 16

Simulation Thermal building simulation coupled with airflow simulation AFW Simulation Façade 3 Cp over height 0.04 0.03 facade 1 Façade 4 Façade 1 Façade 2 wind direction Cp 0.02 0.01 0-0.01 12 18 30 42 54 66 78 90 102 108 0 45 90 135 180 225 270 315-0.02-0.03 DSF2-2 DSF2-3 height DSF2-4 17

Simulation Results cooling load (kwh) 0 200 400 600 800 1000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Monthly results for simulation of DSF at different heights basecase with reflective glass DSF1 DSF2-2 DSF2-4 basecase solar control glass DSF2-1 DSF2-3 Control strategies Controlling solar radiation Controlling HVAC >200W/m² AHU Visible glass Movable louvres Controlling exhaust airflow using a climate sensitive regulator 18

HVAC control Air velocity AND temperature Haase, M. and Amato, A., (2005), Double-skin facades and Thermal comfort, proceedings of Healthy Buildings HK Conference, HKCII, HK. Climate sensitive regulator Enthalpy balance A D B C Haase, M. and Amato, A., (2005), Double-skin facades for Hong Kong, proceedings of the Fifth International Postgraduate Research Conference in the Built and Human Environment, The University of Salford, UK. 19

Simulation Results 1000 900 800 without climate control cooling load (kwh) 700 600 500 400 300 200 100 with climate control 0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec basecase DSF1 DSF2 AFW1 AFW2 Monthly simulation results for DSF and AFW with and without climate control Simulation Results 20% 15% annual cooling load saving [% of basecase] 10% 5% 0% -5% -10% basecase DSF1 DSF2 AFW1 AFW2 Annual simulation results for DSF and AFW with and without climate control 20

Simulation Results 30% 25% 20% 15% 10% 5% Simulation results for basecase, DSF and AFW 0% basecase (internal shading) basecase with reflective glass basecase solar control glass annual DSF1-1 DSF1-2 DSF2-1 DSF2-2 3 hottest months hottest month Conclusions Possible to design an energy efficient DSF system Amount of energy through the building envelope resulting in cooling loads can be reduced by designing a ventilated airflow window that is optimised in respect to heat transfer Airflow through the DSF depends on the cp-values of the façade, estimated the cp-values for different building shapes and heights did not influence the performance of the model with DSF The EAC uses buoyancy to reject solar heat gain Possibility to reduce annual cooling loads as well as peak cooling loads EAC with a climatic control better in reduction of cooling loads in the hot summer period IAC does not reduce cooling load Best results depend on an enthalpy based control that extracts air in order reduce the cooling load 21

Conclusions Planned future work Validation with measured data Detailed daylight analysis Solar assisted extract air device LCA of different façade systems Ventilated facade design in hot and humid climate Background Simulation Analysis Results Conclusions Thank Qs? you http://thegreenroom.arch.hku.hk 22