MVC Moisture Vapor Control FOR NEW CONSTRUCTION AND REMEDIATION OF EXISTING FLOORS

Similar documents
FLOORING INSTALLATION SYSTEMS. Product Catalog

Cutting Edge Solutions Using Advanced Self Leveling Materials. ICRI National Convention April 14, 2010

SECTION HYDRAULIC CEMENT UNDERLAYMENT

1.1 Related Work Specified in Other Sections (Delete if Not Applicable):

Resilient and Wood Floor Covering Flatness Requires High Performance, Cementitious Self-Leveling Underlayment

Engine Bay Floors Floor Resurfacing 4000

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

prospec.com Concrete Repair & Restoration

KOSTER AMERICAN CORPORATION

Acceptable Floor Substrates: Concrete, cured mortar bed, plywood, and backer board.

for the master tradesman Setcrete Product Guide

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Florock Seamless Flooring Systems

We ve got you covered.

Installation Guide LVP Glue Down

Specification and Installation

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

FLOORING Sikafloor NA PurCem ADVANCED GENERATION POLYURETHANE-CEMENT SYSTEMS FOR EXTREME SERVICE CONDITIONS: SELECTION GUIDE

Custom Polishing Systems

SECTION SHEET MEMBRANE WATERPROOFING AND CRACK ISOLATION

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

Epoxy Moisture Vapor Reduction / Mitigation for Flooring. April 2015

SECTION WOOD FLOORING. 1. Section Above-Grade Vapor Retarders. 2. Section Below-Grade Vapor Retarders

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

SECTION WOOD FLOORING

SECTION LATEX-MODIFIED MEDIUM BED MORTAR

Kolorines Glass Mosaic Tiles Project Specification

1. Rapid Set Cement. 2. Methods of preparation. 3. How to stage a job site. 4. Installation Mix, place, finish. 5. Coloring the TRU.

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

FLUID APPLIED WATERPROOFING

RESILIENT FLOORING: Select Step Wood

NXT SUBSTRATE PREPARATION AND PRIMER GUIDE TDS 230N

Construction. Sika Services AG. Sika Services AG. Sikafloor reactive resin systems

CONDUCTIVE RESILIENT FLOORING

SECTION SELF-ADHERING SHEET WATERPROOFING

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

Learn how to reduce the amount of moisture in concrete floors.

Installation Instructions

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

Case Study. Industry: Civil Construction. Client: Marina Bay Sands. Project: Marina Bay Sands Resort Singapore. Date:

ARDEX AMERICAS I Wear Surface Toppings

STEAM SHOWER / ROOM; WOOD OR METAL STUDS Wood or Metal Studs Cement Backer Board Walls, Mortar Bed Floor Ceramic Tile

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Drying of Concrete TDS 183

SELECTION CHART OF CHOOSING ADHESIVES FOR INSTALLING PARQUET

2012 Hardwood Price List

SECTION EPOXY TERRAZZO

RESILIENT PHOTOLUMINESCENT STAIR TREADS

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

prospec.com Flooring Preparation Systems

PECORA-DECK TRAFFIC COATING SYSTEMS

SEALING & BONDING JOINT SEALANTS FOR CURTAIN WALL AND STORE FRONT WATERPROOFING

ECOfit Rolls GUIDE SPECIFICATIONS Ecore Commercial Flooring

RESILIENT FLOORING: Hot and Heavy - Secoya

A. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.

PRODUCT SELECTION GUIDE

PARKING FACILITIES REPAIR SOLUTIONS

Installation Instructions

WINNER. USGBC Best of Building Awards

Selecting and Specifying Ceramic Tile with ANSI and ISO Standards

ARDEX X 90 OUTDOOR TM

ARDEX GUIDE SPECIFICATION ARDEX K 521 Self-Leveling Concrete Topping with Aggregate Surface

Anti-Carbonation Ceramic Coating

Installation Products

SUPER-KRETE SPECIFICATION S-1 EXISTING CONCRETE SURFACE PREPARATION SECTIONS ; /19; ;

Signature Sports Flooring Installation Instructions. For SignaDeck Premium Rubber Tiles

Floor Care Solutions. Cost Effective, High Performance and Easy to Use Concrete Treatments

Cures, Sealers Densifiers & Crystal Technology Ultimate / Proven Concrete Protection

Concrete Polishing Specification Guide TECHNOKOTES ISO Pune, INDIA

Luxury Vinyl Plank Installation Manual 2017

SECTION EPOXY FLOORING SYSTEMS

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

KEY 9418 MMA BINDER DESCRIPTION KEY ADVANTAGES KEY CONSIDERATIONS COMPOSITION COLOR SELECTION SURFACE PREPARATION

ARDEX X 32 MICROTEC Universal Rapid Setting and Drying Thin-to-Thick Bed Mortar

SECTION SPRAY APPLIED FLOOR ADHESIVE

Specifier Notes: Edit the following list as required by the project. List other sections with work directly related to the floor coating.

SECTION RESILIENT STAIR TREADS CSI 3-PART SHORT-FORM GUIDE SPECIFICATION USE FOR OUTLINE OR DD SPECIFICATION ISSUES. EDIT TO SUIT PROJECT

LATICRETE products may help contribute to the following LEED v4 Credits (unless otherwise noted);

SECTION A. American Society for Testing and Materials (ASTM):

Section COATING RESTORATION

adhesive Adhesive 5100 DESCRIPTION USES LIMITATIONS RECOMMENDED SUBSTRATES SETTING INSTRUCTIONS

Decorative, Dynamic Resinous Flooring Systems Combining Warehouse Strength and Exquisite Beauty

Sample Specification Guideline for Installing a Polished Concrete System Using Rapid Set TRU PC SECTION POLISHED CONCRETE TOPPING

SECTION EPOXY TERRAZZO

TechLevel 125 Deep Pour Self-Leveling Underlayment

POROUS (ABSORBENT) SUBFLOORS. (most wood subfloors and some concrete)

Balconies Information. How to waterproof and reduce efflorescence

Section Polished Concrete Finishing. Vexcon

Page 1 of 5 PART 1 GENERAL

SILRES BS CONSTRUCTION SILICONES

MasterSeal M 861 (Formely known as Conipur M 860 Thix)

MAINTENANCE OF CONCRETE /40/50.72 Rehabilitation of Concrete

CTIOA Field Report

Polymer Linings for Restoration & Corrosion Protection of Steel Surfaces: Crude Oil Storage Tank Repair and Reline in New Zealand

Moisture Control Systems

TILE TILE

Transcription:

MVC Moisture Vapor Control FOR NEW CONSTRUCTION AND REMEDIATION OF EXISTING FLOORS FLOORING PROTECTION GUARANTEED Low Odor and Low VOC Treat up to 25 lbs of Moisture Vapor Cost Effective Single Coat Application Faster Construction www.bessern.com

WHY DO FLOORS FAIL? Until it happens, most designers, contractors and owners don t lose sleep over flooring failure. When it does, the results are costly, embarrassing and disruptive to operations. Understanding floor failures and the quickest, most cost-effective way to avoid them are the foundations upon which ENDURIT was built. With over 25 years of experience in the flooring and moisture mitigation industries, we have learned that today s flooring failures are the result of four primary issues that occur on almost every construction project. Flooring Composition The decrease of vinyl asbestos tile (VAT) installations and increase in less permeable flooring has led to entrapped moisture under these new types of materials. VOC Reduction Code required reductions in volatile organic compounds (VOCs) have resulted in flooring adhesives that are not as tolerant to decomposition by high ph or alkaline slab conditions. High Moisture Fast track construction, missing or unreinforced under slab vapor retarders, light weight concrete and troweling and finishing methods can all contribute to high moisture content in new slabs that can cause flooring blisters and adhesion loss. Curing Compounds Curing compounds used to retard the drying of concrete to ensure the concrete s physical properties can cause flooring delamination and de-bonding if not used properly. Every designer or building owner who has experienced flooring failure for any of these reasons knows that effective moisture vapor control (MVC) solutions are as critical to a building s long-term performance as roofing and waterproofing. ENDURIT MVC products offer a unique blend of properties and performance that provide building owners, contractors and designers with fast-track, cost effective solutions to prevent flooring failures. ENDURIT MVC products are: A Vapor Barrier Highly Chemical Resistant Coating Easy to Apply Fast Curing Low VOC A Good Base Coat for Adhesives, Self-Levelers and Top Coats A Concrete Densifier A Guaranteed Defense Against Flooring Failures ENDURIT can be used on new and existing concrete slabs in all types of flooring applications including: Hospitals and Schools Retail, Entertainment and Casinos Office Buildings Hangars and Warehouses Industrial Facilities Running Tracks Field Houses and Sport Facilites Manufacturing Plants

ENDURIT should be used where: Existing concrete slabs have missing or unreinforced under slab vapor barriers New concrete slabs with high moisture content will receive resilient floor coverings Fast track construction is required and new concrete is still green Above grade, light weight, high-moisture content concrete is used Previous flooring failures have already occurred Flooring failure is not an option All ENDURIT Moisture Vapor Control (MVC) products are manufactured in the US in an ISO 9000 certified facility and are low VOC for LEED and sustainable design projects. In addition to the MVC products, the ENDURIT line also offers a complete range of products to prepare substrates for their final floor coverings. We manufacture and supply: cement repair, joint fillers, underlayments and primers. Consult our website or contact your sales representative or our home office for more information.

ENDURIT offers high-performance moisture vapor control solutions that prevent costly flooring failures in all types of commercial, institutional and retail buildings. We provide guaranteed flooring protection to architects, building owners and facility managers through our nationwide network of technical sales professionals and certified installers. When flooring failure is not an option, ENDURIT is the solution. Contact Us: BESSERN Building Products 1400 North Providence Road Media PA 19063 Tel: 484-234-5035 Fax: 484-234-5037 BESSERN Building Products and its affiliated companies have been serving the construction industry for over ten years. With extensive waterproofing, manufacturing and product research and development experience, BESSERN is able to provide cost effective products and solutions to the North American architectural and construction communities. BESSERN Building Products manufacturing facilities are located in North America and we strive to manufacture all of our products in the USA. info@bessern.com

The ENDURIT line of products are designed to work as a system to allow the designer, contractor and owner the ability to quickly and cost effectively prepare floors that are to receive decorative or protective flooring. We offer FLOORING PROTECTION GUARANTEED. Moisture Mitigation MVC 8 MOISTURE VAPOR CONTROL 8 Hour Cure MVC 2 MOISTURE VAPOR CONTROL 2 Hour Cure MVC 2LT MOISTURE VAPOR CONTROL 2 Hour Low Temperature Cure Joint Sealants Quick Fix 100 Polyurea Joint Filler/Repair Polymer Underlayments LEVELEX Primer Underlayment and Non-Porous Substrate Primer LEVELEX 150 Self-Leveling Calcium Aluminate Based Underlayment LEVELEX 250 Self-Leveling Calcium Aluminate Based Underlayment Concrete Repair MRS EM400 Epoxy Mortar Resin Repair System WCP E100 Water Cured Polyurethane Repair Polymer Quick Fix 100 Polyurea Joint Filler/Repair Polymer www.bessern.com BESSERN Building Products 1400 North Providence Road, Media PA 19063 Tel: 484-234-5035 Fax: 484-234-5037