Air Cooled Packaged Air Conditioning

Similar documents
Daikin LXE10E Reefer Machine

WATER CHILLER / HEAT PUMP. The high performance packaged solutions for all your needs

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.

Air-cooled Chillers with High Speed Centrifugal Compressors

Nilan VPL Active heat recovery and cooling (air/air)

Industrial heat pumps and cooling machines Oilon ChillHeat. Optimized heating and cooling performance

MPE 4-76 kw. Outdoor packaged unit. Air/water chillers and heat pumps MPE. Efficiency under all operating conditions. 152 galletti.

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

EES Energy Efficient Systems Rotary Screw Air Compressors kw Horsepower

QINEO PULSE. The versatile welding machine for industry

CI/SfB (57.7) 1st edition

GLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems

Energy Efficiency. best in class

Mechanical Product Overview

Sullair Water Chillers. Precision Chilled Water

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Daikin AURORA MULTI-ZONE HEATING & COOLING SYSTEMS

B. System Design and Performance Requirements

Retail Centre. Green Star - Calculator Guide. Date Issued: April 2009

I S O. Eco-Smart Energy Recovery Ventilator

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

Innotech is a registered Trademark of Mass Electronics Pty Ltd Copyright 2013 Mass Electronics Pty Ltd

PANASONIC AIR CONDITIONING

Product Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs)

Renewable Energy. to heat your home. thermia.com

Save with Business Programs and Services

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models :

Asset Energy Calculator Guidance

HEat PumP technology FoR underfloor HEatINg comfortheat.com.au

TABLE OF CONTENTS SELECTING AN ENCLOSURE COOLING SYSTEM MANUFACTURER. 3 7 QUALITIES TO LOOK FOR IN A MANUFACTURER Manufacturer Location..

Testing and Optimization

Design and development of a residential gas-fired heat pump

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 160 / 25 to 40 bar / 37 to 160 kw

22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Fiberglass Cooling Towers

Proceedings of BS2015: 14th Conference of International Building Performance Simulation Association, Hyderabad, India, Dec. 7-9, 2015.

Achieving Zero Carbon for Buildings in a Densely Populated City and a Subtropical Climate. Guiyi LI Construction Industry Council

Chiller Optimiser Technical Specification

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

AIRCOOL VENTILATORS FURTHER INFORMATION

a f f i n i t y s e r i e s C O M M E R C I A L P A C K A G E D S Y S T E M S

Unit Coolers SKB. 4 kw 30,5 kw.

Flooded Type Water-Cooled Chillers. R134a

Trane eflex. For Ton Light Commercial Applications

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m.

TRANQUILITY WATER-TO-WATER SERIES

Chilled Water System Optimization

Product Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS

It s All a Matter of TechNiQ. NiQ: Our latest generation of energy-saving motors.

Lubricated Rotary Screw Air Compressors. Constant Speed Drives and Variable Speed Drives kw hp

INDOOR UNITS FVXS25F FVXS35F FVXS50 F

Unitary Air Conditioner Field Performance

Geothermal Comfort Systems

A GUIDE TO REACH SYSTEM RELIABILITY. Commercial HVAC Buyers Guide

Standardizing Smart/Connected Products in a Highly Innovative and Dynamic Market

Danfoss and Controls for CO2

Transform your HVAC performance. Good for your comfort, for the environment and for your bottom line

Secondary loop chilled water in super high-rise

2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment

Heat Pumps from Viessmann: Efficient heating with ambient heat

SECTION ROTARY SCREW WATER CHILLERS

THE NEW WAY TO PROVIDE COMFORT IN 4 PIPES SYSTEMS APPLICATIONS

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.

Large University Central Chiller Plant Design Considerations

Specifying... Or Equal

The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, 2009 All Rights Reserved

Application of Advanced Energy Technologies

Comparative Heating Performances of Ground Source and Air Source Heat. Pump Systems for Residential Buildings in Shanghai

Your guide to Irinox blast chillers and shock freezers

An energy-saving control strategy for VRF and VAV combined air conditioning system in heating mode

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 275 / 25 to 40 bar / 37 to 275 kw

DTS & ENERGY MODELLING PROTOCOL GUIDE Version 1.0

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

UFL Micro Biogas CHPs

Underf loor For Schools

SAVE YOUR LIFE SAVE YOUR PLANET

DISPLACEMENT VENTILATION

Integration of the hidden refrigeration capacity as a heat pump in smart energy systems

The complete, efficient, solar water pumping solution Delivering you more water!

Secondary loop chilled water in super high-rise

ANK. ANK heat pump All the heat you want more efficiency more savings more well-being

ASHRAE Chapter Meeting HVAC Noise & Vibration Control Specifications & Best Practices

Control Products & Systems OEM siemens.com/buildingtechnologies-oem

Energy Savers: Air-Source Heat Pumps

Trane Precedent 3- to 10-ton light commercial rooftop units

QINEO Product overview

SorTech package solution description

St. Clair County Road Commission. For Turn Key Replacement of the Existing Chilled Water System Page 1 of 6

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

ENERGY CALCULATOR & MODELLING PROTOCOL

AIR CONDTIONERS XC16. ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology

Light commercial rooftop units Retail applications

Industrial Retrofit Guide. Superior Solutions for Industrial Heating and Ventilating

Product Specifications

MEDICAL REFRIGERATION

ELECTRICAL SYSTEMS. TEST YOURSELF QUESTIONS: Answer Key. CHAPTER 1: Sustainability in Electrical Systems

Caribbean Hotel Energy Efficiency Action (CHENACT)

From Sensor to Smart Home

Transcription:

Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control

More than just another air conditioning company. temperzone is dedicated to pioneering innovative new technologies and creating market-leading, easy-to-use solutions that offer the customer and user complete control. When spaces are wide and open, it s time to rely on temperzone ECO Air Conditioning Rooftop Packaged units * Combine a large commercial floor space and constantly changing cooling or heating loads and you will have a climate control challenge that temperzone s ECO technology can cope with. Increasingly the preferred option for major supermarket and home improvement store chains across Australasia, our highly responsive ECO system is a premium package design which can be relied on to keep customers comfortable. Complete package units designed to connect to duct networks, they range in capacity from 11.6kW to 193.0kW and offer a wide range of air conditioning solutions. Why those in the know are making the switch While chilled water installations have been used to air condition commercial spaces, developers are increasingly moving to the temperzone alternative. Unlike complicated chiller or VRF units, units can be installed quickly and easily, enabling project cost savings. Due to the use of a variable capacity compressor, EC fans and electronic expansion valves controlling refrigerant flow the temperzone ECO package units are economical and efficient in comparison to a chilled water system. This means the ECO Rooftop Packaged AC system can form an important part of a sustainable energy strategy. They can even be used for smaller commercial applications and multi-storey buildings with appropriate duct design. * Refer to Technical specification for ECO series Range Page 1

A smart in-store operator A responsive and adaptive solution, temperzone s ECO system can adjust its own cooling or heating capacity in accordance with changing cooling/heating loads. Thanks to a high-tech, variable capacity compressor the temperzone ECO unit adapts to suit the requirements in the occupied space load. It works hard only when needed, all the while offering the ability to provide comfortable conditions. Featuring simple control technology, our system is easy-to-use. Other benefits The ability to operate within specific time periods, as well as 24-hours-a-day. Quiet mode for low outdoor noise levels, making it ideal for buildings located near built-up residential areas. Ease of servicing. Reliability and simplicity of design. BMS compatibility. The ability to remotely monitor performance parameters. Outdoor fans that can operate within a wide ambient temperature range. The ability to use cool outside air to cool an indoor space during favourable weather conditions, thus eliminating the need to activate the compressor. Page 2

Why call temperzone? As innovative market leaders in air conditioning technology development, temperzone is ideally positioned to play a partnering role in commercial projects and to ensure the selected ECO Air Cooled units will meet the project requirements. All temperzone units are designed, manufactured and supported locally, readily available and with easily accessible technical support. Page 5

Efficiency and Comfort High levels of comfort and energy savings can be provided regardless of climatic conditions. Load Response Controls BMS connectivity or Third-Party control compatibility revolutionises installation, offering a viable alternative to chilled water and VRF installations. Tech Specs The use of variable capacity compressors allows a precise load variation response. High response levels to current load conditions are further guaranteed using Electronic Expansion Valves and variable speed control of the indoor and outdoor fans. Variable Compressor Matches Supply and Demand Capacity Matches Load High Comfort Load Compressor Output Variable capacity Building load Heating Cooling * Contact temperzone on % of fresh air Page 7

ECO Advanced Variable Technologies Compressor 40-100% continuous modulation enables wide capacity range Better humidity control at low capacity See figures 1-2 EC Fans Variable speed EC fan with variable system capacity Superior fan efficiencies with EC fans Increased energy savings at part load conditions with variable 0-10VDC control signal See figure 3 Variable Condenser Fans Extended system operating envelope with fully modulating head pressure control Increased energy savings at part-load conditions with integrated speed control High fan reliability with soft starting and low air noise See figure 5 Fig 1 Fig 3 Fig 5 100 High speed Competitor +15 to +50 C Capacity Total output Digital Digital Fixed Capacity Input Power (%) 75 50 25 Low speed Medium speed temperzone -10 to +52 C -10-5 0 5 10 15 20 25 30 35 40 45 50 Ambient temperature ( C db) Fig 2 100 Instantaneous Input Power (%) 75 50 25 0 Fixed Speed Compressor Variable Capacity Compressor Energy Savings 0 25 50 75 100 Capacity (%) 0 0 25 50 75 100 3 Speed AC Motor power consumption Continuous variable EC Fan Power Consumption Savings from continuous speed adjustment Applicable to OPA186 Fig 4 Moisture removal Super Dry Mode Dry Mode Standard Mode 100 75 50 Unit Capacity (%) Electronic Expansion Valve Optimum control of superheat at varying load for outstanding comfort with indoor air temperature and humidity control Increased efficiencies by lowering head pressure and optimum feeding of heat exchanger coils See figure 6 Dry Mode or Super Dry Mode is available for increased dehumidification, where high humidity may be an issue See figure 4 *OPA ECO Series have additional dehumidification modes available where high humidity may be an issue. Fig 6 Superheat Unit Start-Up ECO Series c/w EEV Unit without EEV * Contact temperzone for Application Page 8 Page 9

ECO Features Efficiency Variable capacity system High efficiency indoor EC fans Variable speed condenser fans Economy cycle option * Electronic expansion valve Generously-sized epoxy-coated evaporator and condenser coils Advanced rifle bore copper tubes Foil face polyethylene insulation Intelligent Defrost Cycle Versatility Flexible handling configurations High ambient application, reliable operation up to 52 C Low ambient cooling reliable operation down to -5 C Low ambient heating reliable operation down to -15 C High outside fresh air applications * Wide cabinet colour range * Louvered coil guards for outdoor coil protection High static indoor up to 450Pa * Powder coated panels to withstand 1000-hour salt spray test Filter cavity with inbuilt filter slides AS1530.3 compliant insulation Installation Control UC controls Precise temperature control Additional de-humidification modes available * BMS Connectivity Third-Party control integration Ease of wiring Service GPO available Individual motor protection Adjustable indoor airflow control Easy maintenance with access panels or access doors Optional WiFi Service Unit * * Refer to temperzone for application Page 10 Page 11

Control temperzone s UC control system makes it easy for an optional thermostat to control the unit and maintain the space at a prescribed temperature. Controlled via an easy-to-use, wall-mounted controller with optional TZT-100 LCD display panel, the system can be upgraded with features including remote temperature sensors. 7-day programmable with 2 events per-day Night set back After-hours run timer Averaging temperature sensor Time clock or manual operation Additional UC features Remote On / Off Remote Common Fault Alarm HP/LP Safety Discharge line safety temperature thermostat No matter how simple or complex the climate control requirements, temperzone can offer a unit that can be integrated into the building air conditioning infrastructure. BMS Simplified BMS Integration with Modbus or BACnet Communication Protocol. Page 12

temperzone s ECO design is one of the most energy-efficient on the market. With the right application and selection advice, energy modelling shows temperzone technology can lead to running cost savings of up to 60%. Energy Savings With the right application and selection advice, temperzone ECO technology can lead to substantial running cost savings. Upgrading air conditioning infrastructure generally involves a process of either: 1. Replacing old technology or 2. Making a choice between competing modern technologies (STD vs ECO) Using ACADs Camel and ACADS Beaver software, annual energy consumption was modelled on a large office supply retailer in Sydney with a total heat load of 148kW. Energy modelling was based on a system consisting of 3 x OPA 550 rooftop units or their R22 equivalents, with economy cycle dampers fitted. The objective was to examine the energy efficiency of three comparative technologies: R22 units with a scroll compressor Standard OPA units ECO OPA units * Hours of operation 6am to 10pm, 7 days. Up to 60% Savings when Replacing Old Technology The results revealed the R22 system consumed 125,824 kwh, the Standard OPA system 86,149 kwh, while the ECO system consumed only 50,866 kwh annually. When we examine individual unit energy consumption we see a substantial 60% energy savings which the OPA 550 ECO achieves over the R22 unit. See figure 7 Fig 7 Annual Energy Usage 62 kpa kwh 41,941 28,716 kwh 16,955 kwh 60% energy savings R22 Unit Std OPA ECO OPA * OPA 550 ECO unit features R410A, Plug Fans, EEV and Digital Scroll Compressor Page 15

Up to 60% Reduction in Greenhouse Gas Emissions temperzone s ECO design has the potential to save you considerable operating costs The energy modelling study revealed the retailer could reduce carbon emissions by 65.2 tonnes annually with ECO units. While HVAC is essential for creating comfortable and safe working environments, in Australia it s also been estimated to account for 45% of energy usage and 63% of greenhouse gas emissions. With such serious environmental considerations at stake, system design and equipment selection is critical when replacing equipment and planning new constructions. Referencing the emission factor of 0.87 we calculated the significant reduction in carbon emissions achieved by replacing old R22 units with ECO units for our retail store - 65.2 tonnes! See figure 8 Your business could potentially save hundreds of thousands, if not millions, of dollars by utilising temperzone ECO technology across your network. The cost savings generated in our single retail store over the 15 year product life expectancy of our air conditioning units was substantial. The study revealed a difference in lifetime cost of ownership** between R22 and ECO units of $160,750. This represents the significant savings which can be attained by replacing old R22 units with ECO technology. In choosing to install ECO units over Standard units the lifetime cost of ownership** savings were $71,500. Lower running and maintenance costs meant recovering the extra capital and installation cost of fitting ECO units was just over two and a half years. See figure 9 Our energy study revealed that replacing R22 units with ECO units throughout 50 stores would save over $8 million in electrical costs * over 15 years. Fig 8 Annual CO 2 Emissions Fig 9 Retail store lifetime cost of ownership ECO STD R22 109.4 tonnes 62 kpa 74.9 tonnes 65.2 tonne reduction in CO 2 emissions $450,000 $400,000 $350,000 $300,000 $250,000 Pay Back Period $160,750 $71,500 R22 Unit Std OPA 44.2 tonnes ECO OPA Our energy study revealed that replacing R22 units with ECO units throughout 50 stores would reduce CO 2 emissions by 48,910 tonnes over 15 years. $200,000 $150,000 $100,000 $50,000 $0 Install 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Year Contact temperzone to help determine your potential project cost savings. * Electricity cost based on $0.15 per kwh ** Includes mechanical systems cost (provide/install), yearly service/maintenance costs, and yearly running costs*. Page 16 Page 17

ECO Range Options and Features The range of available temperzone options allows you to completely customise your unit, giving you flexibility and ultimate control. Configurations Multiple handing options are available to suit most applications. OPA Series ECO ECO ECO ECO ECO Model OPA 116 OPA 161 OPA 186 OPA 201 OPA 242 OPA 294 OPA 340 OPA 370 OPA 465 OPA 550 OPA 705 OPA 855 OPA 960 OPA 1370 OPA 2000 Adjustable Indoor Fan Variable speed Condenser Fans BMS Connection Epoxy Coated Coil Evaporator Condenser Economy Cycle Kit N/A N/A N/A N/A Outside Air Kit N/A N/A N/A N/A Variable Compressor Fixed Compressor EC Indoor Fan Compressor Soft Starter Optional Panel Filters 50mm N/A N/A N/A N/A 100mm N/A N/A N/A N/A N/A N/A N/A N/A Handing Options Supply Air Return Air N/A N/A N/A N/A OPTION STANDARD Page 18 Page 19

OPA Range Technical Specifications OPA Series ECO ECO ECO ECO ECO Model OPA 116 OPA 161 OPA 186 OPA 201 OPA 242 OPA 294 OPA 340 OPA 370 OPA 465 OPA 550 OPA 705 OPA 855 OPA 960 OPA 1370 OPA 2000 Total (Gross) Capacity kw * Cooling 11.6 16.1 18.6 20.0 23.5 29.5 34.0 39.1 44.9 54.6 69.7 85.1 96.0 137.0 193.0 Nett (Rated) Capacity kw * Cooling / Heating 11.33 / 10.8 15.55 / 14.4 18.2 /16.2 19.76 / 18.08 22.34 /22.1 28.3 / 27.2 32.5 /30.1 36.9 / 35.6 43.9 / 41.1 52.9 / 53.4 67.9 / 67.5 79.4 / 78.0 87.9 / 90.0 130.0 / 135.0 184.0 / 213.0 EER/COP * EER* Cooling 3.35 3.24 3.17 3.14 3.19 3.21 3.31 3.23 3.22 2.93 3.30 3.10 2.99 3.16 2.81 COP* Heating 3.58 3.23 3.44 3.33 3.39 3.58 3.59 3.48 3.62 3.35 3.75 3.28 3.40 4.02 3.55 Power Supply Power Supply 3 Phase - 342-436V 50 Hz 3 Phase - 342-436V 50 Hz Run Amps / Phase (A/ph.) IP Rating Compressor 9 / 5 / 5 11 / 7 / 7 12 / 8 / 8 13 / 9 / 9 13 /10 /10 18 /15 / 15 17 / 20 / 17 20 / 24 / 20 20 / 26 / 20 29 / 38 / 29 33 / 40 / 34 45 / 52 / 45 58 / 66 / 57 75 / 83 / 83 125 / 125 / 125 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 Number per Unit 1 1 1 1 2 2 2 2 2 2 2 2 2 4 4 Type Hi Efficiency Scroll Hi Efficiency Digital Scroll 2 x Hi Efficiency Scroll 2 x Hi Efficiency Scroll 2 x Hi Efficiency Scroll 1 x Hi Efficiency Digital Scroll / 1 x Hi Efficiency Scroll 2 x Hi Efficiency Digital Scroll No. of Refrigeration Circuits 1 1 1 1 2 2 2 2 2 2 2 2 2 4 4 4 x Hi Efficiency Scroll Refrigerant R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A R 410A Fans Indoor Centrifugal / EC Direct Drive Centrifugal / EC Direct Drive Centrifugal / EC Direct Drive Centrifugal / EC Direct Drive Plug Fan Forward Curved Forward Curved Forward Curved Plug Fan Plug Fan Plug Fan Plug Fan Plug Fan Forward Curved Forward Curved Outdoor Vari Speed Propeller Type Vari Speed Propeller Type Airflow Nominal** 650 815 1000 1100 1400 1600 1800 2100 2400 2800 3700 4200 4750 7500 9500 Maximum 800 1000 1200 1225 1600 2100 2200 2500 3330 3330 5100 5100 5100 8500 10500 Noise Data *** SPL @ 3 Metres 55 55 59 59 62 57 65 65 68 65 63 63 63 70 62 Overall Dimensions (mm) Length 1110 1160 1160 1230 1675 1780 2058 2080 2344 2344 2902 2902 2902 4668 6248 Width 1200 1200 1200 1200 1567 1490 1625 1670 1949 1949 2149 2149 2149 2425 2430 Height 915 1070 1070 1175 1375 1500 1500 1550 1634 1792 1859 1859 1859 2377 2430 Weight (kg) Nett 193 225 235 270 443 516 631 662 798 878 1105 1133 1129 2000 3070 Shipping 229 266 276 325 513 595 740 775 880 960 1193 1221 1217 2180 3220 NOTES: * To AS/NZS 3823 conditions ** Supply Airflow at Nominal Conditions *** Noise Data measured to BS 848.2: 2014 - Installation Type A - measured in decibels re 1 picowatt **** Units comply with MEPS & or the requirements on the NCC Page 20 Page 21

Sydney: (02) 8822 5700 Newcastle: (02) 4962 1155 Christchurch: (03) 379 3216 Adelaide: (08) 8115 2111 Perth: (08) 6399 5900 Jakarta: (62) 21 2963 4983 Brisbane: (07) 3308 8333 1800 897 253 Melbourne: (03) 8769 7600 Launceston: (03) 6331 4209 Auckland: (09) 279 5250 Wellington: (04) 569 3262 Singapore: (65) 6733 4292 Shanghai: (21) 5648 2078 temperzone.biz Auckland (Head Office and Manufacturing) Sydney (Australian Head Office and Manufacturing) Branches Wellington, Christchurch, Brisbane, Melbourne, Adelaide, Singapore, Shanghai and Jakarta. Distributors Perth, Launceston, Newcastle, Singapore, Shanghai, Beijing, Jakarta, Hong Kong, Sri Lanka, Mauritius, Bangalore, Bangkok, Hanoi, Cambodia, South Pacific Islands and Bangladesh. TEM0124-18