Safety Innovations FOUNDATIONHTSI. Best Practice Recommendations for Infusion Pump-Information Network Integration

Similar documents
Device interoperability through IntelliBridge solutions. Leigh White PCMS Marketing Communications & Digital August 05, 2015

Lexmark esf Applications. Product Demonstration Guide

Optimization: The Next Frontier

HEALTHCARE INDUSTRY VISION: SMART INVENTORY MANAGEMENT SYSTEM

Working with Health IT Systems is available under a Creative Commons Attribution-NonCommercial- ShareAlike 3.0 Unported license.

EHR Site Visit Questionnaire

RFID Vendor Collaboration and Meeting the Needs of Your Clients

Veterans Health Administration Bar Code Medication Administration

THE ESSENTIAL ELEMENT of a

St. James s Hospital leading global innovation in healthcare - a hospital wide approach to adopting GS1 standards

Regional Extension Center Request for Information Meaningful Use EHR Vendors July 26, 2010

EGUIDE BRIDGING THE GAP BETWEEN HEALTHCARE & HIPAA COMPLIANT CLOUD TECHNOLOGY Created for mike elfassi

National Learning Consortium

QUALITY IMPROVEMENT STRATEGY

Connected Healthcare. Integrated Solutions for Connected Clinician Innovation in Practice

Health Information. for Government. Maximize the Value of Your Health Information Exchange

The One Thing You Can Do to Radically Transform Your New Employee Orientation A

OpenText RightFax. OpenText RightFax OnDemand. Product Brochure. Benefits

Lab Outreach Connectivity

Investor Presentation November 2017

HL7 Plenary EHR In Canada

Karisma v3 The most significant release of Karisma in almost ten years

Welch Allyn Connex. Electronic Vitals Documentation (EVD) System

EDI Solutions Your guide to getting started -- and ensuring smooth transactions anthem.com/edi

Digital Slide Sharing and Consultative Strategies and Tactics Pathology Informatics 2011 October 6, 2011

EVALUATE LABELING SYSTEM? IS IT TIME TO YOUR A GUIDE TO CHANGE MANAGEMENT

Solving Healthcare Challenges. Increasing patient safety, reducing errors and improving efficiencies with Intermec Healthcare Solutions.

ProcessUnity Standard Support Policy

HEALTHCARE. Taking workflow where you want it to go.

Laboratory Information Management System Index

Lytec Features Evolution Matrix

University Health Network UDI Capture Work Group Case Study

Create interoperability in a MEDITECH environment

E-Guide PACS INTEGRATION SCHEDULING OTHER ELEMENTS STREAMLINE RADIOLOGY IT

SapphirePlus TM. The Small, Simple Solution for Complex Healthcare. Infusion System

A Review of Constraints to Using Data for Decision Making. Recommendations to Inform the Design of Interventions

HEALTHCARE SOLUTIONS UNIPICK 2 AUTOMATED PACK DISPENSING SYSTEM

2007 CPR Generation Criteria Update: Clinical Decision Support

Dictation & Transcription Solutions

CLINICAL PORTAL Hospital Services. Presented by Stephen Parsons

Centricity * Precision Reporting

ALTIRIS Implementing an Asset and Contract Management System

Innovative ways radiology practices improve workflow

S4B SOLUTIONS GUIDE. Your Guide to Successful Mobile Integration with UC

Australian Communications and Media Authority s Calling the Emergency Call Service Review of Arrangements Discussion Paper

RADIO FREQUENCY (((((((((((((((((((( IDENTIFICATION WRISTBAND SOLUTIONS. Solutions you can identify with

Use of Electronic Health Records to Facilitate Colorectal Cancer Screening Recommendations for Improvement

Connecting Cardiac Device Data and the EHR

A Comprehensive Handbook On Designing A Blueprint

Health Spectrum Pharmacy Services succeeds in a fast-growing market with a range of pharmacy management solutions.

BENEFIT ADMINISTRATION

TECSYS Benefits. Improve margin performance. Optimize preference cards. Free up operating room time. Reduce inventory value and wastage

Update on the BioSense Program Redesign

Qualifacts Carelogic Enterprise S2.15 Costs and Limitations of Certified Health IT

Top 5 Must Do IT Audits

ExtendTime A completely automated IP Telephony time and attendance solution that immediately realizes an organizational return on investment.

Getting the most out of your SIEM technology

BIOMEDICAL EQUIPMENT CUSTOMER DEPARTMENT REFERENCE MANUAL

Constructing Rural Health Information Systems for Critical Access Hospitals:

EDI Solutions Your guide to getting started -- and ensuring smooth transactions anthem.com/edi

DICTATION & TRANSCRIPTION

spend on health care and related markets is also on the rise across all geographies.

Digital Assets Management/Document Imaging Service Level Expectation

Q-STRESS CARDIAC STRESS TESTING SYSTEM

Request for Proposal (Sample Language) For a. Fire Station Alerting System

Evaluating RTLS Technology: Success Criteria for Hospitals

MEANINGFUL USE CRITERIA PHYSICIANS

INCREASING UTILITY: DESIGNING MEDICAL DEVICES AND APPLICATIONS FOR REMOTE MONITORING

Orientation Towards the Future Through Innovation

DFS-Sphere Human Resources Automation Efficient processes, Compliance and Audit Trails: Keys to Success

Health Data Management

meddispense Automated Dispensing Series Medication and Inventory Management that s easy-to-use, easy-to-afford, not easy to be without.

FOR CSPs, IoT-ENABLEMENT SERVICES CAN ACCELERATE REVENUE GROWTH

Appendix B: PDMP Planning Tool

EMR White Paper. Executive Summary.

Benefit Administration System Capabilities & Details. System Details v4 06_16

Vanderbilt University Medical Center

Aligning Process Redesign and Change Management with Project Management (System Implementation Projects)

Electronic Prescribing and Medicines Administration Project Overview

EHR AND ERP INTEGRATION. January 25, 2018

cobas POC IT solutions Bringing it all together

June 2013 Clinical Laboratory News: Volume 39, Number 6

Think Locally, Connect Nationally

Packaging tracking made Smart. Simple. Secure.

Instant Insights. Driving impact through operational readiness: Operational preparation for enabling technology transformation in health care

elearning Ambulatory Course Catalog >> October 2014

Performance Measures & MetricsBased Management

The UDI Experience: From a US Perspective

Are you on track for success?

DIGITAL STRATEGY SUMMARY

The Future of HealthCare Information Technology

Duke University Health System gets smarter for its patients

Greentree. Financial Management

TOOL 8.1. HR Transformation Milestones Checklist. The RBL Group 3521 N. University Ave, Ste. 100 Provo, UT

The Appliance Based Approach for IT Infrastructure Management

RALS Connectivity Without Limits

Transcription:

FOUNDATIONHTSI Healthcare Technology Safety Institute Safety Innovations Best Practice Recommendations for Infusion Pump-Information Network Integration Pump integration requires pervasive and reliable wireless coverage if pumps can t communicate with the server via a wireless network, no integration can occur.

Acknowledgements Special thanks to the following contributors: Todd Cooper, 80001 Experts Al Gould, Nebraska Medical Center Bill Hawley, Intermountain Healthcare, Inc. John Hoffman, BBraun Luis Melendez, Partners Healthcare Gary Mills, Hospira Worldwide Loretta Murphy, Smiths-Medical Cheryl Olson, Mayo Clinic-Rochester Bryanne Patail, VA National Center for Patient Safety Alan Ravitz, Johns Hopkins Hospital Jeff Rinda, Hospira Worldwide Nathanial Sims, Massachusetts General Hospital Erin Sparnon, ECRI Institute Tina Suess, Lancaster Hospital Scott Thiel, Anson Group Acknowledgements also go to the members of the Healthcare Technology Safety Institute s Infusion System Working Group on Integration/Connectivity. About the Healthcare Technology Safety Institute (HTSI) Founded within the AAMI Foundation, the 501(c)(3) charitable arm of AAMI, the HTSI is a community of leaders throughout the healthcare system that are dedicated to one common vision, No patient will be harmed by healthcare technology. HTSI s mission is To engage the entire healthcare community in multi-disciplinary safety initiatives that strengthen the development, management, and use of healthcare technology for improved patient outcomes. HTSI engages the healthcare community in research, education, consensus, and partnerships related to the challenges facing healthcare technology industries, regulatory and accrediting bodies, clinicians, caregivers, and patients. Permission to Copy We encourage you to share this paper with your colleagues. You may freely reproduce this publication for educational purposes only, provided that proper attribution is made as follows: Copied with the permission of the AAMI Foundation and the Healthcare Technology Safety Institute. This publication may not be copied in part or in whole for commercial use. The barriers, must haves, and must dos in this paper are based on the real life experiences of organizations that have learned from these experiences. Healthcare organizations are unique, and each integration involves potential other barriers and challenges that cannot possibly be anticipated here. A thorough, organization-specific and multi-disciplinary risk assessment is an essential foundation for success. These tips will help support that assessment but cannot take the place of it. The views expressed in this publication do not represent the views of the AAMI Foundation or HTSI. The work of the AAMI Foundation is intended to be a helpful resource for healthcare delivery organizations, so that every organization does not have to reinvent the wheel or start their technology management work from scratch. It does not constitute legal, regulatory, operational, or procedural advice, nor does it constitute a standard of care. It is essential that each healthcare delivery organization assess the material in the context of its own organizational needs, culture, technology, and priorities.

Best Practice Recommendations For Infusion Pump-Information Network Integration Introduction Closed-loop medication administration with infusion devices is being driven by the healthcare community in order to improve patient safety and to meet electronic health record (EHR) goals under the Meaningful Use provisions of the ARRA-HITECH act. Therefore, hospitals are exploring the following infusion pump functionalities that not only can reduce errors thus improving safety, but also reduce manual data entry: Auto-programming, in which orders are sent to the pump to be confirmed by a nurse before starting infusions Auto-verification, in which a nurse manually programs the infusion pump and then the programming is checked against a medication order Auto-documentation, in which pump programming, status, and alerts are automatically fed into the patient s electronic medication record for confirmation EHR alerting systems that bring together diverse patient information and pump data to generate combinational alerts in near real time Although these integrative processes and functionalities facilitate accurate, timely, and complete charting of medication infusions, only a handful of healthcare facilities in the United States have adopted one or more of them. Why is integration of pumps with electronic/information systems so slow to take off? In this paper, authors provide current barriers to closed-loop medication administration and offer best practices from some of the early adopters. The Must-Haves and Must- Dos for Pump Integration: Infusion pump integration rests on five specific infrastructure requirements, which must be in place before a facility can move forward with any integration plans: 1. Reliable, pervasive, and secure wireless connectivity; 2. Electronic medication orders containing all infusion parameters; 3. High compliance with bedside barcode scanning for medication administration; 4. Electronic repositories for administration data; and 5. A highly reliable method of associating a pump channel with a patient and a medication. Today s infusion pumps typically use wireless communication with a pump server or gateway. Wireless networks need to be pervasive, highly reliable, and offer adequate security protection and many facilities are often not ready to provide this level of wireless coverage. Some facilities (e.g. Veterans Administration) need to comply with FIPS requirements for wireless One of the strategic decisions hospitals have to make when integrating infusion pumps to the network is whether or not the available technology meets the organization s requirements for information security. 2012 AAMI Foundation HTSI 3

Consider implications of WEP, WPA, and WPA2 to your hospital s wireless network security. Food for Thought The long life of infusion pumps, 7 to 10 years, reduces the window for the adoption of pump integration. Generally, the ability to implement integration is only available in the latest pumps. The opportunity to accomplish integration, therefore, must be planned as part of the budgeting process for new pumps and EHR software. It would be wise to buy integration-capable pumps even if you are not ready to integrate. If you don t, you could wait a long time before you can integrate your pumps with your data or information network(s). security, which require support from the facility, pump supplier, and router/server suppliers. One approach to addressing security concerns is for patient specific information to be documented and contained outside the pump (i.e., at the pump server or EHR level). If the pump does not contain a patient ID, medication order number, or other patient identifying data but only receives programming information, sends delivery information, serial number, and channel, the data transmission between the pump and its server may not comply with FIPS requirements. Pump integration requires pervasive, reliable, and secure wireless coverage if pumps can t communicate with the server via a wireless network, no integration can occur. However, facilities vary widely in wireless coverage and signal strength, and facilities need to make sure their systems can still function during times when the pump is out of communication or the pump server is unavailable. Infusion pumps typically have cache-and-forward capabilities to prevent data loss, with sufficient memory to store pump information until the pump can re-connect. Additionally, most wireless pumps have notification capabilities when communications between the pump and the server are lost. These notifications can be in the form of a visible icon on the pump showing that data transmission was interrupted or as a message directly from the server indicating interruption. Although a gold standard approach to wireless integration would include assessment of coverage and potential interference at all bed locations, this may not be feasible for all facilities. One rough method of quickly assessing wireless coverage is through the support and use of voice over internet protocol (VOIP) communication devices. If patient care areas in the facility have been shown to offer adequate coverage and uptime for VOIP use, it is likely that they will offer sufficient support for infusion pump integration. Even after a wireless environment is made ready for networked pumps, facilities need to monitor their networks for jamming or other malicious activity that could prevent pervasive and timely wireless transmission, and also routinely assess the impact that pump traffic itself is having on the network. Along with adequate wireless coverage, facilities need prompt and seamless support from EHR and pump suppliers, especially when it comes to troubleshooting and site-specific customization during and after implementation. While pump suppliers generally view medical device integration (MDI) as a business driver (and therefore worthy of the time and effort necessary for a successful implementation), the story can be quite different when it comes to EHR suppliers. Be aware that many suppliers prioritize MDI far behind other initiatives like ancillary site support or public health reporting. What Can a Healthcare Facility Do Now to Get Ready for Infusion Pump Integration? First, establish correct and consistent use of both bedside barcoding [e.g., barcode enabled point of care (BPOC) or bar code medication administration, (BCMA)] and electronic IV medication orders that hold all pieces of data required for an infusion to begin. Although Computerized Provider Order Entry (CPOE) is certainly a path to electronic IV medication orders, a facility does not necessarily need to have CPOE in play to integrate infusion pumps into the EHR. However, a facility must have some type of electronic IV medication order available for entry into the system. For example, electronic orders can either be created through CPOE or through a pharmacist entering an electronic order after verifying a non-electronic order from a physician. Until BPOC/BCMA and electronic IV medication orders (CPOE or other) are accomplished, do not attempt to integrate your pumps with your information network. Next, establish executive support for integration and give a clear mandate for safety to a single individual who can serve as an integration champion. The integra 4 2012 AAMI Foundation HTSI

tion champion must own the CPOE, emar, BPOC, and any other order and documentation system and serve as a single point-person to all suppliers concerning medical device integration. The champion must have the authority (granted by the facility s decision makers, e.g., executives) and backing of the clinical users to carry out integration readiness efforts. To support the integration champion, establish a standing department that is responsible for Medical Device Integration (MDI) and is led by the integration champion. An integration team should be established that consists of representatives such as nurses, physicians, pharmacists, clinical program managers, dieticians, medical informatics professionals, medical researchers, risk managers, HIM, quality improvement managers, IT managers, purchasers, and clinical engineers. The size and makeup of the team should be adjusted according to the integration project. Such a group should have the following duties: 1. Identifying devices that have information that is useful to clinicians 2. Setting clinical priorities for integration 3. Overseeing design and development, making sure that the integration of pump devices into documentation and alerting systems meets the requirements of all care areas using pumps 4. Budgeting for development and equipment purchases 5. Purchasing specifications and assistance for new devices 6. Installing new or updated software to support device integration 7. Ensuring ongoing maintenance for installed device integration systems and collecting and analyzing data on the efficiency of installed systems. After BPOC/CPOE, a champion with a mandate, and a team of support have been achieved, then proceed with readying your devices and systems. RECOMMENDATIONS Regardless of whether a facility is selecting new suppliers or attempting integration with existing suppliers, the following steps should be taken. 1. Device readiness Purchasing authorities in your facility must buy the appropriate devices and interface equipment. Clinical Engineering and IT must be able to support the connected devices. Equipment management must be able to supply enough equipment to areas that use integration. It is confusing to have only some of the equipment (of the same type) capable of interface. Devices should be identified and labeled with a short 4 or 5 digit asset number (not the serial number) that is human readable (and rememberable) and scanable to facilitate ease of use during integration. The asset number should ideally be programmed into the device and is separate from the serial number. Clinical Engineering and Equipment Management are responsible for maintaining the labels. 2. Pharmacy readiness Move towards radical standardization on concentrations and formulations towards a goal of one or two concentrations that support most (98%) patients. Ensure that CPOE, pharmacy, pump drug libraries, and other related systems reflect this new formulary and establish a plan for updating all systems in response to formulary changes. 3. IT Infrastructure readiness Assess and upgrade wireless coverage in care areas and pump storage locations. Assess and upgrade database infrastructure. Assess server/client hardware and software requirements. 2012 AAMI Foundation HTSI 5

Contact Us Has your healthcare organization implemented any of the strategies discussed in this publication? Do you know of a healthcare facility that has dealt with a technology-related issue and has a story to share? If so, we would love to hear from you! Please email HTSI@aami.org. Create an information security and privacy policy that you can send to suppliers whose devices or systems include protected health information. Determine wireless capabilities and identify potential interference sources. 4. Nursing readiness Study and describe current infusion administration workflows in various care areas. Keep these observations in a document that you share with pump and EHR suppliers. Develop use cases for pump integration that cover infusion pump use in all areas. Keep these observations in a document that you share with pump and EHR suppliers. Establish a plan for compliance monitoring over time. 5. EHR readiness BPOC system needs to be able to accept a scanned-in pumping channel during the 5 rights bar code scanning process. This is the most efficient way for the EHR to link the patient, the IV medication and the pump, and will probably require an upgrade or update to the BPOC configuration and workflow. Pharmacy-verified electronic orders must be available to the BPOC system that includes pump programming parameters. The system has to be able to receive pump data from the pump server and integrate it into infusion charting and the patient record. Conclusion Although infusion pump and network integration has been slow in the U.S., it will likely remain a high priority for healthcare facilities to improve patient care and to comply with the Meaningful Use requirements. It was the intent of this white paper to outline the major steps to successful integration and to emphasize the need for pervasive and highly reliable secure wireless networks that offer adequate security protection, electronic medication orders containing all infusion parameters; high compliance with bedside barcode scanning for medication administration; electronic repositories for administration data; and a highly reliable method of associating a pump channel with a patient and a medication. 6 2012 AAMI Foundation HTSI

Contact Information: AAMI Foundation 4301 N. Fairfax Drive, Suite 301 Arlington, VA 22203 Phone: (703) 525-4890 Fax: (703) 276-0793 Email: slombardi@aami.org www.aami.org/foundation Contributions and Donations: To make a tax-deductible donation, please complete the donation form at www.aami.org/foundation/donate and mail your check or money order to: AAMI Foundation 4301 N. Fairfax Drive, Suite 301 Arlington, VA 22203-1633 2012 AAMI Foundation HTSI 7