Transmission Tower Maintenance Bottom Line Savings Through Active Maintenance

Similar documents
SAFETY BARRIER SYSTEM

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

Table of Contents. List of Drawings

SUPERIOR PRODUCTS INTERNATIONAL LEAD-BASED PAINT ABATEMENT ENCAPSULATION METHOD THAT ELIMINATES SANDBLASTING FOR STEEL STRUCTURES

LUSTRELOK Acrylic Coating for Galvanized Steel

Aliphatic Acrylic-Polyester Polyurethane

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

MECHANICAL TUBE DIVISION

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

GHD Materials Technology

Maximum Rust Protection!

TL FOUNDATIONS. Fleet Strategy. Document TP. FL /10/2013

Real estate managers and

Frank D. Rea Director of Coatings Services / Chief Chemist

Liquid Road Bituminous Surface Treatment for Parking Lots

ADVANCED PROTECTIVE COATING SYSTEM Breakthrough Protective Top Coat and High Performance Epoxy Primer

Refer to Substrates & Surface Preparation.

Bharat Heavy Electricals Limited Piping Centre Chennai-17. Specification Number Revision Number Sheet Number PC:E:GF: of 7 CONTENTS

Bringing coatings to life. Performance-engineered precipitated silicas

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

MAKE ROOFS LAST LONGER

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

ASBESTOS CEMENT PIPE: ASSET OR LIABILITY?

Specifications for FL-100 Soffit Panel

Technical Information Sheet

STEEL FINISH COATING SYSTEMS. Meeting Steel Design Specifications for Pole Finishes

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

Joint Surface Preparation Standard. NACE No. 3/SSPC-SP 6 Commercial Blast Cleaning

Structural Steel: An Industry Overview

Brise Soleil Fixed Sunshades

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

PRICES: DESIGN: TAXES:

Wood Pole Restoration

PAINT SPECIFICATIONS WHO TO TALK TO AND WHAT OWNERS SHOULD EXPECT

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

Attractive, Durable Composite Sound Walls

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

ITW ROCOL METAL ENRICHED PAINTS

STANDARD SPECIFICATION FOR CRIBLOCK CONCRETE CRIBWALL

Avoiding Fading Paint

Coating Types. Coating Systems. Coating Basics. Why coatings are used Component of coatings Methods of protection Service environment

The Best of Both Worlds!

Heat Resistance Range

HYDROJETTING INFORMATION. a six page issue October 1999

SSPC: The Society for Protective Coatings. Commercial Blast Cleaning

Nucor Steel - Arkansas Customer Focused, Quality Driven, Environmentally Responsible

Remediating Salt Attack in Adobe

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Refining Corrosion Technologist NACE-RCT-001

two component high build amine adduct cured phenolic epoxy primer

Cleaning and Protecting Concrete Surface Preparation, Application, and Inspection. NESMEA October 17, 2017 Kenneth A. Trimber KTA-Tator, Inc.

Assessment of reinforcement corrosion in concrete façades

Anti-Carbonation Ceramic Coating

INDUSTRIAL GUARDRAIL SYSTEMS

TRANSPORT II " 10.5" MOUNTING POSTS FENCE LINE POST. Classic gate shown GATE OPENING CANTILEVER GATE SAFETY WARNING

POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES

SAMPLE SPECIFICATION

Cathodic Protection as a Corrosion Control Alternative

Asset Performance Management from GE Digital. Enabling intelligent asset strategies to optimize performance

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

Penn State Forestland Management Office Multi-Strand High-Tensile Wire Fence Specifications

QUALITY ASSURANCE MANUAL FOR APPLICATORS OF ELASTOMERIC SHEET LININGS

Corrosion, Coatings and Hydropower

THERMOPLASTIC POWDER COATINGS

Designing Bridges for a 100-year Service Life. TEAM Conference 2016

1.1 This Section includes surface preparation and the application of base coats, intermediate and topcoats.

Vegetation Management Plan

A well proven method for corrosion control. Swedish high quality work by

SECTION 1045 PAINT FOR STRUCTURAL STEEL

How to digitally transform your manufacturing operation. Manufacturing sector whitepaper

Metal Roof and Wall Panel Components in Contact with Preservative Treated Lumber A position paper

Installation Instructions

INSTALLING A CYPRESS DECK. The Natural Choice. Southern Cypress Manufacturers Association

METAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

ARTICLE XXIII SMALL WIND ENERGY SYSTEMS 85

Hot-Dip Galvanized Fabrication Considerations

Safety Railing Solutions

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

Thermal Diffusion Galvanizing

Innovative New Chimney Design for Wet Flue Gas. Paul Nederlof, Msc. Hadek Protective Systems, Inc. 651 Holiday Drive Pittsburgh, PA 15241

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

Anti-Graffiti Coatings Guide

Application Guidelines

Overview of Coatings and Surface Treatments

VHB Tapes. Design Guide for Sign Assembly. Proven worldwide. Now even more versatile for more sign applications, more surfaces.

Why Does Rust Occur? 7.1 IN GENERAL

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Understanding the Basics of Electrocoat. Kelly Moore Development Chemist

SPECIALIST PRODUCTS. Leading edge solutions for specialist commercial applications. Innovative technology. Ultimate performance

GUIDE SPECIFICATION EXETER VERSA SHIELD SECURITY SCREEN SYSTEM

SECTION SIMULATED STONE MASONRY

A. Product Data: For each type of deck, accessory, and product indicated.

FOR STEEL POTABLE WATER TANKS INTERIOR AND EXTERIOR CORROSION PROTECTION. Hydro-Zinc

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

ITEM 458 WATERPROOFING FOR STRUCTURES

PRODUCT DATA SHEET Sika Galvashield XP

MTS-Test Workmanship Standards

STANDARD INSPECTION OF GUY ANCHORS IN DIRECT CONTACT WITH SOIL. Rev: 4/06

TECHNICAL PROCEDURE TABLE OF CONTENTS

Transcription:

Transmission Tower Maintenance Bottom Line Savings Through Active Maintenance Introduction Transmission towers/poles are among an electrical utility s largest and most important commercial assets. Unfortunately, as the need to generate profits and shareholder dividends has intensified, regular investment in tower/pole maintenance has often been reduced or eliminated to cut costs. Ironically, such cost-saving measures have the potential to double or triple long-term maintenance costs while increasing the risk for power outages and public safety problems....regular investment in tower/pole maintenance has often been reduced or eliminated to cut costs. Ironically, such cost-saving measures have the potential to double or triple long-term maintenance costs while increasing the risk for power outages and public safety problems. This white paper describes how electrical utilities can implement active transmission tower/pole maintenance programs, and details the long-term cost savings they can realize when they use them in place of reactive, fix-as-needed maintenance regimes. On Top of Tower Maintenance The Principle of Exponential Corrosion There are hundreds of thousands of transmission towers in the United States, operated by more than 3,200 electrical utilities 1. These poles and lattice works of galvanized steel typically range from 50 to 180 feet in height, but can reach 900 feet or more. In the United States, the vast majority of these structures were built between 1960 and 1990, which means they have had or will soon be needing maintenance and/or repairs. Depending on where they are situated, galvanized transmission towers/poles can function for 20 to 35 years before showing the first signs of corrosion. While galvanized steel in rural or desert settings may remain rust-free for up to 50 years, coatings in salty coastal air or heavy industrial environments may only do so for 15 years or less. Unfortunately, once the corrosion of a galvanized transmission tower/pole does begin, it advances exponentially. As the chart below indicates, a tower/pole with less than 5 percent rust at age 30 can oxidize to the point of failure within ten years. More critically, as the corrosion of the tower/pole accelerates, so too can the cost of time, labor and materials to repair it. THE PRINCIPLE OF EXPONENTIAL CORROSION Footnote: 1 : http://www.eia.doe.gov/electricity/page/prim2/toc2.html

Transmission Tower Maintenance 2 Four Phases of Corrosion The following section depicts transmission towers through four phases of corrosion and describes the physical condition of each. PHASE I Phase I Coffee stain rust (cosmetic, not structural) 5% rust On edges and bolts Approximately 1-2 mils of galvanization remains PHASE II Phase II Abrasive rust On bolts, edges and horizontal flat areas Rust falls off on touch

Transmission Tower Maintenance 3 PHASE III Phase III Extensive, abrasive rust PHASE IV Phase IV The tower falls Managing and Budgeting for Repairs When corrosion begins to consume a transmission tower/pole, the key to managing repair costs is to arrest its progress before the unit transitions from one phase of corrosion to the next. For electrical utilities, the optimal solution is to repair the entire inventory of towers/poles as early as possible in Phase I, when it is less costly. Unfortunately, that simply is not possible for most utility companies because of budget constraints and the varied ages of the towers/poles in their inventory.

Transmission Tower Maintenance 4 The following chart details the repairs and costs for tower maintenance in Phases I, II and III. The cost of repairing or replacing a tower in Phase IV is total. Description and Cost of Repairs Phase Tower Condition Repair Regimen Cost (per tower)* Phase I Coffee stain rust (cosmetic) Minimal cleaning (5%) $2,750 5% rust One coat of paint 1-2 mils of galvanization remain One summit of tower Phase II Abrasive rust Cleaning (up to 50%) $5,555 On bolts, edges and horizontal flats Spot or full primer as needed Rust falls off upon touch One coat of paint Two summits of tower Phase III Extensive, abrasive rust Cleaning (75 to 100%) $8,883 One full coat of primer Optional intermediate coat One coat of paint Three summits of tower Prioritizing Repairs As the chart demonstrates, because of the relative difference in cost and labor, repairs for Phase III damages can be up to 70 percent more expensive than Phase I repairs. For this reason, the most effective way to maximize maintenance expenditures is not to fix towers/poles needing the most or least extensive repairs, but to fix those closest to transitioning from one phase to the next. According to this protocol, repairs to towers/poles early in Phases I, II or III are typically deferred to those later in each phase. This approach not only saves several thousand dollars per repair over the short term, but also allows utilities to plan on-going repairs in the most systematic way possible. Long-Term Cost Savings When electrical utilities were deregulated in the late 1980s, there was an immediate and dramatic drop in the resources directed to transmission tower maintenance. Although utilities often owned or maintained thousands of transmission towers/poles, for many the organizing goal shifted from delivering power to maximizing return on investment. As a consequence, many of today s transmission towers/poles are in need of significant repair. The chart below shows how much money utilities can save by actively maintaining large transmission tower/pole inventories compared to allowing them to deteriorate before repair. # of Towers Phase of Corrosion Cost of Repair Total Repair Added Long-Term (per tower) Cost Cost 5,000 Phase I $2,750 $14 million Phase II $5,555 $28 million $14 million Phase III $8,883 $44 million $30 million 10,000 Phase I $2,750 $28 million Phase II $5,555 $56 million $28 million Phase III $8,883 $89 million $61 million 25,000 Phase I $2,750 $69 million Phase II $5,555 $139 million $70 million Phase III $8,883 $222 million $153 million * Figure based on standard 50- to 180-foot galvanized steel transmission towers.

Transmission Tower Maintenance 5 In addition to saving millions of dollars, an active maintenance program delivers the benefits of increased employee and public safety, a lower risk for power outages, and the goodwill of the community for towers that are clean and attractive. PPG s Eliminate The Movement Program A Plan for Active Transmission Tower Maintenance PPG Industries offers a comprehensive maintenance program designed to eliminate the movement of transmission towers/poles from one phase of corrosion to the next. Elements of the program include the following: Application of Keeler and Long s KL4400 Series Paint, an anodic, self-priming PPG paint engineered specifically for use on electrical transmission towers, bridges and substation structures Free structural grid evaluations, including on-site surveys by trained and experienced PPG personnel Recommendations of trusted and qualified repair contractors Development of maintenance plans, including prioritization of repairs Paint specification proposals Application consultation Proposed budgets Below Ground Inspections, Too PPG s Eliminate the Movement program includes thorough underground evaluation of transmission towers and poles, which deteriorate faster than visible sections due to constant exposure to sub-surface moisture, alkalis and other hazards. About KL4400 Series Paint KL4400 Paints are technically advanced coatings developed specifically for the power industry by Keeler & Long, a leading coatings manufacturer with decades of experience in the power industry. Keeler and Long s anti-corrosive coatings provide year-round protection from severe weather as well as the contaminants and aggressive exposure associated with heavy industrial environments. In addition to self-priming on weathered galvanized or previously painted steel surfaces, KL4400 Series Paints offer the following benefits: Lowest cost-per-square-foot, per-year protection Minimal surface preparation Excellent surface wetting ability Single-coat application Easy application by brush or mitt Low-VOC formulation 90% solids by volume Single-component To learn more about Keeler & Long s coatings for the power industry or PPG s Eliminate The Movement transmission tower maintenance program, visit www.keelerandlong.com, call 1-888-9-PPGPMC (1-888-977-4762) or email PMCMarketing@ppg.com.

PPG Industries, Inc. One PPG Place Pittsburgh, PA 15272 USA 1-888-9-PPG-PMC (1-888-977-4762) www.ppgpmc.com/northamerica pmcmarketing@ppg.com PPG and the PPG logo are trademarks owned by PPG Industries, Inc. PM16769 10/2010