POLYETHYLENE LINED PRODUCTS PROJECTS TABLE OF CONTENTS IMPACT BAFFLES CATCH BASINS MANHOLE MATERIALS LARGE DIAMETER ROUND MANHOLES

Similar documents
STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

PRECAST RECTANGULAR CHAMBERS

16. Design of Pipeline Structures.

THE ADVANTAGES HDPE MANHOLES

MANHOLES, VAULTS AND CATCH BASINS SECTION A. Section Soil and Aggregate Materials. C. Section Storm Drainage Systems

Engineering Design Center. Standard Drawings. 1st Edition -January 2016

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

New Fulton State Hospital Energy Control Center and Services Building (ECC/SVC) Project Number: M

(b) Discuss in brief shaft spillway with neat sketches. Marks 04. OR Q (2) Explain in brief USBR stilling basin. Marks 08

DIVISION 3: SEWER. Improvement Design Standards City of Dundee Oregon. Division 3 : Sewer Page 1

Pre-Sloped Drain System

THE WORLD LOOKS UP TO COMPOSITE ELEVATED TANK

Section [ ] Storm Water Treatment Device

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY PHASE II

TANK SUMPS SINGLE WALL & DOUBLE WALL

SECTION MANHOLES AND STRUCTURES. A. Section Includes: 1. Manholes for water, storm drain and sanitary sewer systems.

Table of Contents Con Cast Pipe Price List - Page 1

iv) Alberta fish weirs

SECTION UTILITY MANHOLES AND STRUCTURES

TYPE "A" CATCH BASIN

GV 001 Equipment Bases and Enclosures General Information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Hydrodynamic Separation Product Calculator

Inlets & Catch Basins

ROLES AND RESPONSIBILITIES Small Pond Approval. SWM MD-378 Pond Checklist Training 10/17/07. Exemptions EMBANKMENT HEIGHT. Height of Dam Weir Wall

Aqua-Swirl Stormwater Treatment System

Storm Drainage

SECTION STORM DRAINAGE DESIGN, GRADING, AND WATER QUALITY TECHNICAL CRITERIA TABLE OF CONTENTS PAGE 402 STORM DRAINAGE DESIGN CRITERIA 400-1

CITY STANDARD DETAILS FOR CITY OF JACKSONVILLE FLORIDA DEPARTMENT OF PUBLIC WORKS

Storm. Section. B. General Design and Drawing Standards Design

A reliable solution for ditching, underpassing and rainwater drainage

SEPTIC TANK CONSTRUCTION GUIDELINES

SECTION XXXX POLYMER CONCRETE PUMP STATIONS

Attachment D-1: Civil/Structural Scope of Work

***************************************************************************************************************

ENGINEERING DESIGN & IMPROVEMENT STANDARDS

Lyon Creek Cedar Way Stormwater Detention Dam Operation and Maintenance Manual

APPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

Welcome: What is U-Drain? Drain Materials. Flow

MODEL Stormwater Local Design Manual. City of Centerville

11. Construction processes and materials Power House Maintenance Building Fuel Treatment Building...

Fabrication and Installation Table of Contents

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

Stormwater Local Design Manual For Houston County, Georgia

FLOOR AND AREA DRAINS

CHAPTER 6. Sanitary Sewer

NEW CASTLE CONSERVATION DISTRICT. through. (Name of Municipality) PLAN REVIEW APPLICATION DRAINAGE, STORMWATER MANAGEMENT, EROSION & SEDIMENT CONTROL

TAMDID PIPES GRP MANHOLE BROCHURE

INDUSTRIAL GUARDRAIL SYSTEMS

The Inspection Process. Waxhaw N.C.

ADDENDUM NO. 1. Mallory Valley Utility District Technical Specifications & Design Criteria for Water Supply & Distribution Facilities

Training Certification Categories

This is only a general checklist; please refer to the CVWD Development Design Manual (DDM) for all requirements and regulations.

CHAPTER 12: DRAINAGE

Operation and Maintenance Manual

On Site Detention System.

A.2.a Random Riprap... Table

We Offer Solutions. Temporary Storage

SECTION FACILITY SANITARY SEWERS

SITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

Delivering Reliability. Electrical Vaults. Power & Energy-Underground Structures

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

CORRUGATED HDPE PIPES FOR SEWER AND STORMWATER

Light Duty Ramps. Loadingdocksupply.com PHONE:

Pipe blocked by sand - NOW. Sand will block the pipe completely after some time. How can I do it better?

Alberta Bridge Inventory STANDARD BRIDGE & CULVERT COMPONENTS. Standard Bridges. Typical Bridge Components. In Alberta there are about 13,300 bridges.

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

CHECKLIST FOR STREETS, INLETS, AND STORM SEWER DESIGN

ENGINEERED SOLUTIONS. Terre Arch Concrete Detention/Infiltration. Solutions Guide

Inspection of New One- and Two- Family Dwellings

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

Table of Contents AQUA-SWIRL 2

CONCRETE PIPE JOINTS, YOUR BEST CHOICE

SERVICE LINES, METERS AND APPURTENANCES

The Islamic University of Gaza- Civil Engineering Department Sanitary Engineering- ECIV 4325 L5. Storm water Management

Concrete Pipe Joints Your Best Choice

SECTION 3 DRAINAGE. 3-1 General. 3-2 Drainage Ordinances and Legal Requirements

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

Project Type: Drainage and Storm Systems

Box Culverts. Easy to install, suitable for very shallow or deep fill, ideal for use in a wide variety of civil engineering applications.

Smarter. Safer. Leaner.

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

TYPICAL INSTALLATION INSTRUCTIONS

Sediment Basin. Fe= (Depends on soil type)

Electrical Work. NOV Embankments Over Swamps and Compressible Soils

Installation Instructions

SECTION STORM UTILITY DRAINAGE PIPING

General Discussion of Corrosion Monitoring Considerations in Pipeline Design


CONSTRUCTION PROCEDURES. AWWA D110 Type I Prestressed Concrete Tanks

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Dam Safety Inspection Checklist

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

Administrative Changes

HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)

SPECIFICATION FOR SPHERICAL VESSELS (PROJECT STANDARDS AND SPECIFICATIONS)

200 Series In-Slab Pool Fittings

Transcription:

2018 www.precon.ca

2 2017 PROJECTS

TABLE OF CONTENTS 3 2 PROJECTS 11 POLYETHYLENE LINED PRODUCTS 3 TABLE OF CONTENTS 12 IMPACT BAFFLES 4 CATCH BASINS 13 INLET/TURNOUTS 5 MANHOLE MATERIALS 14 FLARED END SECTIONS 6 LARGE DIAMETER ROUND MANHOLES 15 CHECK/DROP STRUCTURES 7 CONNECTION OPTIONS 16 PANEL WALLS 8 STANDARD VAULTS 17 BUILDINGS 9 MULTI-PANEL VAULTS 18 TRENCH DRAINS/UTILITY DUCTS 10 STORM POND STRUCTURES 19 BOX CULVERT 20 VALUE ADDED ACCESSORIES 21 HYDROGUARD 22 PRECAST SLABS & BASES 23 MECHANICAL

4 CATCH BASINS CATCH BASIN MATERIAL Precon manufactures several Catch Basin pieces including tops, barrels, bases and adjuster rings to accommodate the requirements of Alberta various cities and municipalities. For Catch Basin Manhole materials please see Manhole Material on page 5. 1. Municipal storm sewer infrastrucure 2. Leachate Collection Systems SIZES Precon manufactures both 600mm and 900mm diameter catch basin material. Precon is committed to maintaining a wide range of catch basin material in stock. There are many different sizes ranging from 1070mm to 1220mm high monobases and 600mm to 1200mm high barrels (600mm diameter material only comes in an 1850mm high monobase).

MANHOLE MATERIALS 5 MANHOLE MATERIALS Precon s precast concrete Manhole Materials are a combination of tops, barrels and bases and when configured, allow the creation of manhole systems to suit a variety of needs. Custom Prebench Bases are built to specification, with watertight pipe connections at the appropriate angle, height and slope. Bases are also prebenched with the correct trough, making installation easy, fast and worry-free. Precon s Slab Tops come in a variety of openings to suit any installation. Conical Tops are also available for 1200 diameter material. 1. Municipal Infrastructure 2. Lift Stations 3. Leachate collection systems 4. Toe drain collection systems SIZES Precon has a wide range of manhole material in stock. There are many different sizes, ranging from 300mm to 2000mm high barrels and 50mm to 150mm high grade rings. Any desired height can easily be achieved. Precon is the only CSA Certified Producer of Manhole Material in Alberta

6 LARGE DIAMETER ROUND MANHOLES LARGE DIAMETER MATERIAL Precon s large diameter precast concrete Manhole Materials also consist of a combination of tops, barrels and bases and when configured, allow the creation of manhole systems to suit a variety of needs. Precon provides custom Prebench Bases for its large diameter Manholes too. Like the standard 1200mm diameter Manholes, the large diameter Manholes are built to specification, with sized pipe connections at the appropriate angle, height and slope. Bases are also prebenched with the correct trough, making installation easy, fast and worry-free. Precon s Slab Tops come in a variety of openings to suit any installation. 1. Municipal Infrastructure 2. Lift Stations 3. Leachate Collection Systems 4. Toe Drain Collection Systems SIZES Precon can provide the following sizes for large diameter requirements: 1500mm, 1800mm, 2400mm and 3000mm.

CONNECTION OPTIONS 7 Weldable F Thimble Boot Connection F Type Thimbles Grout Connection *flat wall only *flat wall only Steel Sleeve Link Seal E Type Thimbles Kwik Seal Connection *flat wall only *supplied by contractor *flat wall only Grout Connection CONNECTIONS INCLUDE: Kwik Seal Connection Boot Connection Link Seal A-Lok *supplied by contractor

8 STANDARD VAULTS STANDARD VAULTS One of Precon s most versatile products, the Standard Vault is an engineered, concrete box that can be used in a variety of applications from manholes to water meter chambers. Precon s Standard Vaults are typically used to accommodate smaller vault installations. These stackable pieces are available in standard 400mm increment riser sections so that the required structure height is easily achieved. Custom riser heights are also available. The Standard Vault piece, much like the rest of our product line, can also have many different types of accessories cast in. It can also be poured with almost any size of hole. These pieces are quick and easy to install. 1. Municipal Infrastructure 2. Lift Stations 3. Valve Chambers 4. Drain Chambers 5. Air Valve Chambers 6. Water Reservoirs 7. Water Meter Chambers 8. Pump Stations 9. Storm Pond Control Structures

MULTI-PANEL VAULTS 9 MULTI-PANEL VAULTS Precon s Multi-Panel Vault Structure is an engineered, multi-piece structure that is assembled on-site. The Multi-Panel Vault is typically used to accommodate larger vault installations. The structure is highly versatile in its assembly. Large structures can be designed, produced and shipped with minimal assembly. Typically, installation and backfill can be achieved in one day. This structure can accommodate all kinds of pipe penetrations, grout holes, thimbles and personnel access. Integrated splitter walls, weir walls and intermediate floors are also possible with Multi-Panel Vaults allowing for wet well/dry well combinations, energy dissipation and access to large mechanical or valve equipment. The installation process provides unique opportunities for accommodating difficult installations. For instance, when installing large diameter water mains with valve assemblies, a portion of the structure can be installed, followed by the installation of the interior piping and valve assembly and completed with the installation of the remaining pieces of the structure. 1. Large Vaults Exceeding Standard Vault Sizing 2. Lift Stations 3. Valve Chambers 4. Drain Chambers SIZES 5. Air Valve Chambers 6. Water Reservoirs 7. Water Meter Chambers 8. Pump Stations 9. Storm Pond Control Structures Multi-Panel vaults can be produced in sizes up to and including 5000mm ID x 6500mm ID. The width and length are in increments of 250mm and the height is in increments of 250mm. All Multi-Panel Vaults range from 1250mm 8000mm inside height with wall thicknesses of 204mm or 254mm.

10 STORM POND STRUCTURES STORM POND STRUCTURES Precon s Storm Pond Structures are engineered structures consisting of Standard or Multi-Panel Vaults. These storm pond structures can be used in a variety of applications, with or without weir walls and built to accommodate gates and ICD control devices, and super catch basin vaults. Precon vaults can accommodate grated, straight, or sloped tops to be used as large catch basins. These structure tops can accommodate a variety of slopes. The storm pond structures, like the rest of our product line, can also have many of the different types of accessories cast in, or can be poured with almost any size of rough hole.

POLYETHYLENE LINED PRODUCTS 11 POLYETHYLENE LINED PRODUCTS Precon can cast a polyethylene liner onto the inner surface of most of our products*. The polyethylene liner protects against corrosion, permeation and groundwater intrusion. Precon s polyethylene liner is resistant to most acids, bases, hydrocarbons, vapors and microbiological attacks. For more details please see www.precon.ca * requires field welding at joints

12 IMPACT BAFFLES IMPACT BAFFLES Precon s Impact Baffle Structure is an outlet style structure, with an engineered basin and headwall, designed to dissipate energy as water is introduced into a drainage system or natural water course. The dissipation of energy is controlled by a baffle wall that is cast into the structure and can handle flows up to 5.6m 3 /second. The headwall is also constructed with a unique anchoring system that acts as a seepage barrier. The Impact Baffle is easy to handle and install. It has been designed to USBR standards and Precon can accommodate many different thimbles or pipes that can be cast directly into the structure. 1. Pipeline terminal structures requiring energy dissipation during normal or event type flow situations SIZES Precon s Impact Baffle Structures are produced in five standard sizes to accommodate flows between 0.4m 3 /second to 5.6m 3 /second and pipe sizes up to 1350mm diameter.

INLET/TURNOUTS 13 INLET/TURNOUTS Precon s Inlet/Turnout Structure is an engineered structure consisting of a headwall and basin designed for water inlet and outlet control. The structure is exceptionally easy to handle and install and the unique design of the headwall acts as an anchoring system as well as a seepage barrier. The Inlet/Turnout is ideal for municipal, irrigation and farm turnouts or pond inlets. This structure compliments Precon s Check and Check/Drop structures, creating a system that allows efficient water control in a water conveyance system. The Inlet/Turnout is designed based on the shape of the canal or existing topography, required flow, and pipe size. Several different types of connection accessories (eg. 86 or 150 psi thimbles) can also be cast into the headwall that can accommodate numerous gates, pipe thimbles and valves with a variety of bolt hole patterns. 1. Inlets for Irrigation Pipelines 2. Inlet/Turnout for Irrigation Water Delivery 3. Inlet/Turnout for Storm Pond Control 4. Outlet for Drainage Control SIZES Precon Inlet/Turnouts sizes are sized based on the slope of the canal or pond and the size of the conveyance pipe. Precon can accommodate slopes of 2:1, 2.5:1 and 3:1.

14 FLARED END SECTIONS FLARED END SECTIONS Precon s precast concrete headwalls offer a cost effective alternative to in-situ structures for connecting pipework discharging into open watercourses such as rivers, ditches, ponds and swales. These precast headwalls allow contractors to quickly complete pipe runs without extending time spent in environmentally sensitive areas, and preventing the requirement of using the costly cast in place option. Precon s headwalls come in standard sizes for 200mm to 1200mm diameter pipe and are available to suit most pipe types. Headwalls can be configured with dissipaters, handrails, grillages and other custom items such as bolt on icd plates, sluice or flap gates. Precast headwalls also control erosion and scour resulting from excessive velocities and turbulences.

CHECK/DROP STRUCTURES 15 CHECK/DROP STRUCTURES Precon s Check/Drop Structure is a multi-piece (typically using 9-13 pieces) precast concrete structure that assembles in the shape of an H and is installed in an irrigation canal perpendicular to the flow of water. The shape of the structure provides a double water cutoff, helping to prevent bank erosion by ensuring that water cannot migrate around or under the structure. The Check/Drop Structure is engineered and designed to USBR standards and is a reliable solution for water level and grade control in a water conveyance system, where there is also a change in elevation. The Check/Drop Structure allows the designer to control water levels and water velocity. It works well in conjunction with Precon s Inlet/Turnout as a way to obtain necessary water levels for water delivery. The structure is designed for canals with flows as large as 3.0m 3 /second. The width of the canal at the top and bottom, the flow of water and the type of gate are taken into account when designing the structure. The structure can accommodate Overshot gates, Stop Log Systems and several other popular gate systems. The Check/Drop Structure can also be used to measure the flow of the water. 1. Level and grade control in the storage, delivery and drainage of water systems where there is a change in elevation 2. Weir Structure 3. Check/Drop Structure 4. Drop Structure SIZES Precon Inlet/Turnouts sizes are sized based on the slope of the canal or pond and the size of the conveyance pipe. Precon can accommodate slopes of 2:1, 2.5:1 and 3:1.

16 PANEL WALLS PANEL WALLS Precon s precast concrete Panel Walls are constructed using smaller, more manageable pieces that are assembled to make a wall of any length. The Panel Wall is engineered and designed based on the opening required and the depth necessary to eliminate seepage. The product is shipped in pieces. On site, it is easily assembled, making it ideal for remote areas. Stability of the wall must be taken into account when selecting this structure 1. Simple Canal Weir Structure 2. Pond Level Control SIZES Panel Walls can be built to a maximum height of 4000mm and any length. Wall pieces can be poured 152mm, 204mm or 254mm thick.

BUILDINGS 17 BUILDINGS Precon s precast concrete Building is an engineered, two piece structure that combines a safe, secure location for electrical, computer or automated equipment with a maintenance-free exterior. The precast concrete Building, when equipped with a heavy duty steel door, is vandal resistant. It is water tight, fire resistant and vermin proof, making it ideal in harsh environments. The precast concrete Building can be insulated (R20) and several other accessories or options can be built in. Installation is quick and easy and, when compared with alternative steel or wood products, the precast concrete Building provides a long lasting solution. 1. Control Buildings 2. Generator Sites 3. Accessory to Lift or Pump Stations 4. Mechanical Room SIZES Precon s Buildings are produced in four standard sizes BD2025 (2.0m OD x 2.5m OD), BD2530 (2.5m OD x 3.0m OD), BD3040 (3.0m OD x 4.0m OD), BD3050 (3.0m OD x 5.0m OD). Insulation can vary in thickness depending on the application.

18 TRENCH DRAINS/UTILITY DUCTS TRENCH DRAINS/UTILITY DUCTS Trench Drains/Utility Ducts are engineered, 3-sided concrete boxes that can be used in a wide variety of applications from cableways to fluid conveyance trenches. Precon s Standard Trenches are available in a wide variety of spans from 508mm to 4000mm wide. These connectable pieces are also available with a variety of tops types (eg. CL-800 precast tops and grating tops). Trench Drains/Utility Ducts, much like the rest of our product line, can also have many different types of accessories cast in. It can also be poured with almost any size of hole. These pieces are quick and easy to install. 1. Trench Drains 2. Utility Ducts 3. Cableways 4. Rupture Disk Trenches

BOX CULVERT 19 BOX CULVERT Precon s precast box culvert is ideal for channeling storm and stream water and are designed for a wide range of bury depth and loading applications. Our box culvert is compliant with Alberta Transportation s CL-800 traffic loading requirements for road crossings (engineer stamped shop drawings provided upon request). Each section can be poured monolithically, or 3-sided with a removable lid for future access or maintenance. We have the ability to provide a mechanical connection between each section creating a secure joint that is simple and efficient to install. SIZES Standard Sizes Include: 1.2m x 1.2m 1.5m x 1.5m 1.8m x 1.8m 1.8m x 2.4m 2.5m x 3.0m 3.0m x 4.0m

20 VALUE ADDED ACCESSORIES PRECON HAS A WIDE VARIETY OF ACCESSORIES INCLUDING: Ladder Rungs Ladder Extensions Hatches Lifting Devices Grates, Walkways and Safety Platforms Water Control Gates Lifting Davits Trash Racks Inlet Control Devices Various Sealants Spray Foam Insulation 3-D Printing

HYDROGUARD STORMWATER HYDRODYNAMIC SEPARATOR HYDROGUARD 21 BENEFITS lower capital cost compared to other competitive structural stormwater quality measures treats low and high flows separate low flow path minimizes scour at high flows removes trash captures oil spills removes fine suspended solids supports Smart Growth principles since Hydroguard is installled underground maximizing the development density potential engineered for traffic loading and anti-bouyancy minimum elevation difference between inlet and outlet pipe can be used as a bend structure sized based on local hydrology and continuous simulation technical support to assist with design and approval minimal maintenance for typical applications multiple access points for inspection and maintenance. MODEL Structure Inside Diameter (SID) in (mm) Structure Depth ft(mm) Sediment Volume ft3 (m3) Oil/Floating Trash Volume US gal (L) Permanent Pool Wet Volume US gal (L) HG 4 4 (1200mm) 5 (1500mm) 38 (1.1) 76 (288) 470 (1779) HG5 5 (1500mm) 5.5 (1650mm) 64 (1.8) 123 (465) 808 (3059) HG6 6 (1800mm) 6 (1800mm) 92 (2.6) 203 (768) 1269 (4803) HG8 8 (2400mm) 7 (2000mm) 163 (4.6) 457 (1730) 2507 (9490) HG 10 10 (3000mm) 7.6 (2300mm) 268 (7.6) 893 (3380) 4455 (16864)

22 PRECAST SLABS/BASES PRECAST SLABS/BASES Precon s precast concrete slab and bases are engineered and designed for each individual project and application. These products are highly customizable. Slabs and bases, much like the rest of our product line, can also have many different types of accessories cast in. These pieces can also be poured with almost any size of opening. On site, they are easily installed, making them ideal for remote areas. 1. CSP Bases 2. Pipeline Protection Slabs 3. Boat Ramp Slabs 4. Anti-Floatation Slabs 5. Compressor Bases

MECHANICAL 23 MECHANICAL Precon offers complete packages for Valve Chambers and PRV s, including the mechanical. All Precon s Valve Chambers are engineered to meet Alberta s CL-800 loading and all installed mechanical components are pressure tested prior to shipping. Precon s prepackaged mechanical structures are one less thing for you to worry about. 1. PRV s 2. Backflow Valves Chambers 3. Flow Meters 4. Air Relief Valve Manholes

35 Sales Office 23012 110Ave NW Edmonton, Alberta T5S 2C6 Phone: 780.464.0755 Main Office/Production Plant #2, CP Rail Road, Kipp Road Coalhurst, Alberta Phone: 403.382.4938 Sales Office #333, 4615 112 Avenue SE Calgary, Alberta T2C 5J3 Phone: 403.723.7225 Toll Free: 1.800.661.8020 www.precon.ca