KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV KPH-SF-03-MTLV KPH-FO-01-MTLV KPH-FO-02-MTLV KPH-CW-01-MTLV KPH-CW-02-MTLV KPH-PR-01-MTLV KPH-PR-02-MTLV KPH-LE-01-MTLV KPH-RD-01-MTLV KPH-TP-01-MTLV KPH-TL-01-MTLV KPH-TL-02-MTLV C & I DISCLAIMER EXPANDED PANEL JOINT ENGAGED PANEL JOINT VERTICAL JOINT PROFILE VERTICAL JOINT VERT. JOINT BETWEEN STUDS BASE DETAIL FLUSH BASE DETAIL FLUSH W/ EXTRUSION BASE AT NOTCHED CONCRETE BASE AT OVERHANG (WITH BASE FLASHING) OUTSIDE CORNER (MITERED TILE) INSIDE CORNER STOREFRONT WINDOW HEAD STOREFRONT WINDOW JAMB STOREFRONT WINDOW SILL FRAMED OPENING HEAD FRAMED OPENING JAMB CURTAINWALL (FLUSH) HEAD CURTAINWALL (FLUSH) JAMB PARAPET DETAIL PARAPET DETAIL OVERHANG CAP LOW EAVE DETAIL RAKE DETAIL PANEL TERMINATION TRIM END LAP TRIM END LAP WITH HEM INDEX SHEET
DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. WALL SYSTEM DEFLECTIONS ARE TO BE DETERMINED BY THE ENGINEER OF RECORD. ALL DETAILS ARE BASED ON TYPICAL STUD WALL CONSTRUCTION WITH SINGLE. FOR ATTACHMENT TO OTHER WALL SUPPORT SYSTEMS, PLEASE CONTACT KINGSPAN TECHNICAL SERVICES FOR FASTENING RECOMMENDATIONS. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. DISCLAIMER
INTERIOR FACE SHADOWLINE KS24SL 2" - 6" EXTERIOR FACE 24" COVERAGE SHADOWLINE VERTICAL SUPPORT AT 16" O.C. FEMALE JOINT CONTINUOUS BUTYL SEALANT CONTINUOUS BUTYL SEALANT (OPTIONAL) SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 4 " - 14 HEX HEAD S WALL PANEL INSTALLATION DIRECTION MALE JOINT 1" CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EVO MID-CLIP (TYP) THROUGH AS REQUIRED EXPANDED PANEL JOINT
1" - 3" VERTICAL SUPPORT AT 16" O.C. (NOT BY INGSPAN) 2 3 4 " [69mm] INSULATED METAL PANEL (IMP) 1 4 " - 14 HEX HEAD S WALL PANEL INSTALLATION DIRECTION CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EVO MID-CLIP (TYP) THROUGH AS REQUIRED PANEL THICKNESS 1" [25mm] 1 3 4 " [43mm] ENGAGED PANEL JOINT
VERTICAL SUPPORT AT 16" O.C. 1 4 " - 14 HEX HEAD S 1" PANEL THICKNESS SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 3 4 " CONTINUOUS KARRIER RAIL THROUGH AT KARRIER RAIL (BELOW) NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS VERTICAL JOINT PROFILE
TRIPLE STUD 5" MIN. VERTICAL SUPPORT FILL GAPS 1 4" OR LARGER WITH F.I.P. INSULATION CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT THROUGH AT KARRIER RAIL (BELOW) 5" MIN. OPTIONAL FRAMING CONTINUOUS MENDING PLATE 1 4 " - 14 HEX HEAD S SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 3 4 " 1" PANEL THICKNESS CONTINUOUS KARRIER RAIL VERTICAL JOINT
VERTICAL SUPPORTS AT 16" O.C. CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FILL GAPS 1 4" OR LARGER WITH F.I.P. INSULATION 1 4 " - 14 HEX HEAD S VERTICAL SUPPORT 1 3 4 " 1" PANEL THICKNESS CONTINUOUS KARRIER RAIL THROUGH AT KARRIER RAIL (BELOW) VERTICAL JOINT BETWEEN STUDS
Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) VERTICAL SUPPORTS 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER WEEP HOLE BASE FLASHING CONTINUOUS BUTYL SEALANT BELOW BASE FLASHING (AIR SEAL) TO CONCRETE BASE CHANNEL SET IN SEALANT BASE DETAIL FLUSH
Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) VERTICAL SUPPORTS 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT AT PANEL JOINT CONTINUOUS BUTYL SEALANT 1 4 " - 14 HEX HEAD S BASE CHANNEL SET IN SEALANT WEEP HOLE BASE FLASHING CONTINUOUS BUTYL SEALANT BELOW BASE FLASHING (AIR SEAL) TO CONCRETE ALUMINUM BASE EXTRUSION FILL VOID WITH COMPRESSIBLE FOAM CLOSURE BASE DETAIL FLUSH WITH EXTRUSION
VERTICAL SUPPORTS Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM WEEP HOLE BASE FLASHING TO CONCRETE BASE CHANNEL SET IN SEALANT CONTINUOUS BUTYL SEALANT CONTINUOUS BUTYL SEALANT BELOW BASE FLASHING (AIR SEAL) BASE AT NOTCHED CONCRETE
VERTICAL SUPPORTS Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM WEEP HOLE TO CONCRETE BASE CHANNEL SET IN SEALANT CONTINUOUS BUTYL SEALANT BASE FLASHING BASE AT OVERHANG (WITH BASE FLASHING)
NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL CONTINUOUS KARRIER RAIL 1 3 4 " F.I.P. INSULATION AS REQUIRED (BY OTHERS) 1" OUTSIDE CORNER TRIM FIELD MITER CUT PANELS POP RIVETS THROUGH AT KARRIER RAIL (BELOW) EVO MID-CLIP (TYP) SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT INSIDE CORNER TRIM CONTINUOUS BUTYL SEALANT AT PANEL JOINT VERTICAL SUPPORT OUTSIDE CORNER (MITERED TILE)
NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS F.I.P. INSULATION AS REQUIRED (BY OTHERS) VERTICAL SUPPORT 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT POP RIVETS CONTINUOUS KARRIER RAIL OUTSIDE CORNER TRIM INSIDE CORNER TRIM 1 3 4 " [44mm] POP RIVETS EVO MID-CLIP (TYP) CONTINUOUS BUTYL SEALANT AT PANEL JOINT 1 3 4 " [44mm] CONTINUOUS KARRIER RAIL INSIDE CORNER
INSULATED METAL KARRIER PANEL (IMP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S WITH WASHER VERTICAL SUPPORT AT 16" O.C. (NOT BY INGSPAN) CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM WEEP DRIP FLASHING WINDOW FIXED WITH FERRULES FIELD CUT FEMALE JOINTS WHERE REQUIRED WEATHER SEAL BY WINDOW INSTALLER WINDOW BY OTHERS STOREFRONT WINDOW HEAD
INTERNAL FINISH TO ARCHITECTS DESIGN VERTICAL SUPPORT AT 16" O.C. 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL JOINT INTERIOR CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS INSULATED METAL KARRIER PANEL (IMP) WINDOW BY OTHERS WEATHER SEAL BY WINDOW INSTALLER THROUGH AT KARRIER RAIL (BELOW) JAMB FLASHING W/ OPEN HEM RETURN 1 3 4 " STOREFRONT WINDOW JAMB
WEATHER SEAL BY WINDOW INSTALLER WINDOW SILL FLASHING 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER WINDOW BY OTHERS INTERNAL FINISH TO ARCHITECTS DESIGN Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S WITH WASHER INSULATED METAL KARRIER PANEL (IMP) VERTICAL SUPPORT AT 16" O.C. (NOT BY INGSPAN) STOREFRONT WINDOW SILL
1 3 4 " 1" 3" INSULATED METAL KARRIER PANEL (IMP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM 1 4 " - 14 "LOW PROFILE" THROUGH WEEP DRIP FLASHING FIELD CUT FEMALE JOINTS WHERE REQUIRED WEATHER SEAL BY INSTALLER DOOR, DOOR FRAME AND COMPONENTS FRAMED OPENING HEAD
DOOR, DOOR FRAME AND COMPONENTS INTERNAL FINISH TO ARCHITECTS DESIGN VERTICAL SUPPORT AT 16" O.C. 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL JOINT INTERIOR CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS INSULATED METAL KARRIER PANEL (IMP) WEATHER SEAL BY WINDOW INSTALLER THROUGH AT KARRIER RAIL (BELOW) JAMB FLASHING W/ OPEN HEM RETURN 1 3 4 " FRAMED OPENING JAMB
1 3 4 " 1" 3" INSULATED METAL KARRIER PANEL (IMP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM 1 4 " - 14 "LOW PROFILE" THROUGH WEEP FIELD CUT FEMALE JOINTS WHERE REQUIRED WEATHER SEAL BY INSTALLER CURTAINWALL SYSTEM BY OTHERS CURTAINWALL (FLUSH) HEAD
NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL INTERNAL FINISH TO ARCHITECTS DESIGN VERTICAL SUPPORT AT 16" O.C. WEATHER SEAL BY WINDOW INSTALLER 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL JOINT INTERIOR CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS INSULATED METAL KARRIER PANEL (IMP) 1 3 4 " EPDM MEMBRANE BONDED TO FACE OF PANEL (BY OTHERS) CURTAINWALL (FLUSH) JAMB
WRAP MEMBRANE OVER PANEL FACE PARAPET CAP FLASHING TRIM CONTINUOUS BUTYL SEALANT PARAPET BLOCKING SLOPE TO PARAPET BACKER Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S INSULATED METAL KARRIER PANEL (IMP) PARAPET DETAIL
PARAPET CAP WRAP MEMBRANE OVER PANEL FACE PARAPET BLOCKING STAINLESS STEEL EVO MID-CLIP (TYP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER CONTINUOUS BUTYL SEALANT 1 4 " - 14 HEX HEAD S INSULATED METAL KARRIER PANEL (IMP) PARAPET DETAIL OVERHANG CAP
REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION FIP INSULATION AS REQUIRED 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER CONTINUOUS BUTYL SEALANT COUNTER FLASHING EAVE STRUT 1 4 " - 14 HEX HEAD S Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) EAVE ANGLE INSULATED METAL KARRIER PANEL (IMP) LOW EAVE DETAIL
REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION RAKE ANGLE FIP INSULATION AS REQUIRED 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER CONTINUOUS BUTYL SEALANT RAKE FLASHING 1 4 " - 14 HEX HEAD S Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) RAKE ANGLE INSULATED METAL KARRIER PANEL (IMP) RAKE DETAIL
1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT STRUCTURAL SUPPORTS CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS CONTINUOUS KARRIER RAIL BACKER ROD & SEALANT THROUGH AT KARRIER RAIL (BELOW) PANEL TERMINATION
(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP
FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM END LAP WITH HEMS