FACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET

Similar documents
KS SERIES - VERTICAL INSTALLATION

200 / 300 SERIES PANELS COLD STORAGE

Insulated Panels North America. KarrierPanel Universal Barrier Wall Solution

Thin Brick Façade. Façades Installation Guide

ELEVATION FOR DETAIL REFERENCE ONLY

ELEVATION FOR DETAIL REFERENCE ONLY

BENCHMARK Evolution Axis

ELEVATION FOR DETAIL REFERENCE ONLY

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

ELEVATION FOR DETAIL REFERENCE ONLY

Designwall 2000/4000. Façades Installation Guide

ELEVATION FOR DETAIL REFERENCE ONLY

Proper Installation of Insulated Metal Wall Panels

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

TRIAD CORRUGATED METAL, INC.

Maximum thermal performance ISOLEREN INSULATED METAL PANELS INSTALLATION GUIDE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

MID-RISE DESIGN & CONSTRUCTION

How do you install yours?

NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS

STUCCO FAILURES and REMEDIATION Roger G. Morse AIA

PBR & PBU Panels. Technical/Installation Information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION METAL BUILDING SYSTEMS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Architectural Wall Panels (AWP) KS CX/EB/FL/FL-S/ MR/MM/PL/WV KS1000 CW/LV/TL

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

KNIGHT WALL SYSTEMS GUIDE DETAILS:

PBR & PBU PANELS. Technical/Installation Information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

KNIGHT WALL SYSTEMS GUIDE DETAILS:

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

TECHNICAL SPECIFICATIONS & PROFILES PIR INSULATED EXTERNAL WALL PANEL TECHNICAL GUIDE TO CONQUEROR TM PIR INSULATED EXTERNAL WALL PANEL

Alply CLASSIC WALL Architectural Insulated Panel Wall System

RS24-10 Single-Section Skylight System

Installation Procedures for the Ultra Air Barrier Wall System

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

Series Silicone structural glazed. Installation Instructions

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

S BI COM P ON E NT CA T ALOG

Page 1 of 5

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

ALLMET CONTINENTAL INSTALLATION GUIDE

RS32 Multi-Section Skylight System under/over seam clip double diverter

Prior to ordering and installing materials, all dimensions should be verified by field measurements.

YCW 250 I-Beam Curtain Wall System Installation Manual

LP SmartSide Perfection Shingle

Senturion TM III Wall System

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

Central Snap. Condition Details C SNAPDETAILS

OSB.COMFORT INSTALLATION GUIDE * 1 RECOMMENDED USE PANEL COMPOSITION

A. Section includes extruded aluminum windows with operating sash, operating hardware, and insect screens.

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

Perimeter Relief and Control Joints in Fire-Rated Gypsum Board

SPECIFICATION GUIDELINE

PRODUCT DATA ECMS EC-200 SYSTEM COMPOSITE WALL PANEL 8/25/2016

Insulated Metal Panels

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

STRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SURESILL WATER MANAGEMENT GUIDE

Senershield -R / Senershield -VB

INSULATED PANEL OVERVIEW

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

TMS 114 XT TECHNICAL MANUAL

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

7520 Casement Windows

HIGHLANDVIEW CEMETERY CHAPEL

Series 510-I Thermal Heavy Commercial Projected Window

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

SWING DOOR SPECIFICATION

Western States 7/8 Corrugated

A Design-Build Project: Repairing the Courthouse Square Complex

Duracast Pressure Plate Installation Instructions

SECTION MANUFACTURED ROOF EXPANSION JOINTS

The Alternative to Storefront. Gerkin Model 58F

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

138 H-STUD AREA SEPARATION WALL SYSTEM

Brava Spanish Tile. Installation Manual. Brava Roof Tile Phone: Fax:

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

SECTION GYPSUM BOARD ASSEMBLIES

TW-12. (Horizontal Installation) Installation Guide

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

Thermal Bridging and Whole Building Energy Performance

Container Installation Guide

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

TMS 152 / 152T / 152XT TECHNICAL MANUAL

Guideline Specifications

LUX Specifications. Section S - Preformed Steel Siding

Transcription:

KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV KPH-SF-03-MTLV KPH-FO-01-MTLV KPH-FO-02-MTLV KPH-CW-01-MTLV KPH-CW-02-MTLV KPH-PR-01-MTLV KPH-PR-02-MTLV KPH-LE-01-MTLV KPH-RD-01-MTLV KPH-TP-01-MTLV KPH-TL-01-MTLV KPH-TL-02-MTLV C & I DISCLAIMER EXPANDED PANEL JOINT ENGAGED PANEL JOINT VERTICAL JOINT PROFILE VERTICAL JOINT VERT. JOINT BETWEEN STUDS BASE DETAIL FLUSH BASE DETAIL FLUSH W/ EXTRUSION BASE AT NOTCHED CONCRETE BASE AT OVERHANG (WITH BASE FLASHING) OUTSIDE CORNER (MITERED TILE) INSIDE CORNER STOREFRONT WINDOW HEAD STOREFRONT WINDOW JAMB STOREFRONT WINDOW SILL FRAMED OPENING HEAD FRAMED OPENING JAMB CURTAINWALL (FLUSH) HEAD CURTAINWALL (FLUSH) JAMB PARAPET DETAIL PARAPET DETAIL OVERHANG CAP LOW EAVE DETAIL RAKE DETAIL PANEL TERMINATION TRIM END LAP TRIM END LAP WITH HEM INDEX SHEET

DISCLAIMERS: THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES. LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED ON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARY VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER). PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS. ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND ILLUSTRATION PURPOSES ONLY. WALL SYSTEM DEFLECTIONS ARE TO BE DETERMINED BY THE ENGINEER OF RECORD. ALL DETAILS ARE BASED ON TYPICAL STUD WALL CONSTRUCTION WITH SINGLE. FOR ATTACHMENT TO OTHER WALL SUPPORT SYSTEMS, PLEASE CONTACT KINGSPAN TECHNICAL SERVICES FOR FASTENING RECOMMENDATIONS. CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS AND FASTENING PATTERNS. DISCLAIMER

INTERIOR FACE SHADOWLINE KS24SL 2" - 6" EXTERIOR FACE 24" COVERAGE SHADOWLINE VERTICAL SUPPORT AT 16" O.C. FEMALE JOINT CONTINUOUS BUTYL SEALANT CONTINUOUS BUTYL SEALANT (OPTIONAL) SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 4 " - 14 HEX HEAD S WALL PANEL INSTALLATION DIRECTION MALE JOINT 1" CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EVO MID-CLIP (TYP) THROUGH AS REQUIRED EXPANDED PANEL JOINT

1" - 3" VERTICAL SUPPORT AT 16" O.C. (NOT BY INGSPAN) 2 3 4 " [69mm] INSULATED METAL PANEL (IMP) 1 4 " - 14 HEX HEAD S WALL PANEL INSTALLATION DIRECTION CONTINUOUS KARRIER RAIL (KARRIER RAIL AVAILABLE IN 1"- 3" FACES) EVO MID-CLIP (TYP) THROUGH AS REQUIRED PANEL THICKNESS 1" [25mm] 1 3 4 " [43mm] ENGAGED PANEL JOINT

VERTICAL SUPPORT AT 16" O.C. 1 4 " - 14 HEX HEAD S 1" PANEL THICKNESS SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 3 4 " CONTINUOUS KARRIER RAIL THROUGH AT KARRIER RAIL (BELOW) NOTE: CONTACT KINGSPAN TECHNICAL SERVICES FOR SPECIFIC PROJECT RECOMMENDATIONS VERTICAL JOINT PROFILE

TRIPLE STUD 5" MIN. VERTICAL SUPPORT FILL GAPS 1 4" OR LARGER WITH F.I.P. INSULATION CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT THROUGH AT KARRIER RAIL (BELOW) 5" MIN. OPTIONAL FRAMING CONTINUOUS MENDING PLATE 1 4 " - 14 HEX HEAD S SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 3 4 " 1" PANEL THICKNESS CONTINUOUS KARRIER RAIL VERTICAL JOINT

VERTICAL SUPPORTS AT 16" O.C. CONTINUOUS MENDING PLATE CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT FILL GAPS 1 4" OR LARGER WITH F.I.P. INSULATION 1 4 " - 14 HEX HEAD S VERTICAL SUPPORT 1 3 4 " 1" PANEL THICKNESS CONTINUOUS KARRIER RAIL THROUGH AT KARRIER RAIL (BELOW) VERTICAL JOINT BETWEEN STUDS

Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) VERTICAL SUPPORTS 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER WEEP HOLE BASE FLASHING CONTINUOUS BUTYL SEALANT BELOW BASE FLASHING (AIR SEAL) TO CONCRETE BASE CHANNEL SET IN SEALANT BASE DETAIL FLUSH

Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) VERTICAL SUPPORTS 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT AT PANEL JOINT CONTINUOUS BUTYL SEALANT 1 4 " - 14 HEX HEAD S BASE CHANNEL SET IN SEALANT WEEP HOLE BASE FLASHING CONTINUOUS BUTYL SEALANT BELOW BASE FLASHING (AIR SEAL) TO CONCRETE ALUMINUM BASE EXTRUSION FILL VOID WITH COMPRESSIBLE FOAM CLOSURE BASE DETAIL FLUSH WITH EXTRUSION

VERTICAL SUPPORTS Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM WEEP HOLE BASE FLASHING TO CONCRETE BASE CHANNEL SET IN SEALANT CONTINUOUS BUTYL SEALANT CONTINUOUS BUTYL SEALANT BELOW BASE FLASHING (AIR SEAL) BASE AT NOTCHED CONCRETE

VERTICAL SUPPORTS Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM WEEP HOLE TO CONCRETE BASE CHANNEL SET IN SEALANT CONTINUOUS BUTYL SEALANT BASE FLASHING BASE AT OVERHANG (WITH BASE FLASHING)

NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL CONTINUOUS KARRIER RAIL 1 3 4 " F.I.P. INSULATION AS REQUIRED (BY OTHERS) 1" OUTSIDE CORNER TRIM FIELD MITER CUT PANELS POP RIVETS THROUGH AT KARRIER RAIL (BELOW) EVO MID-CLIP (TYP) SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT INSIDE CORNER TRIM CONTINUOUS BUTYL SEALANT AT PANEL JOINT VERTICAL SUPPORT OUTSIDE CORNER (MITERED TILE)

NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS F.I.P. INSULATION AS REQUIRED (BY OTHERS) VERTICAL SUPPORT 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT WITH MARRIAGE BEAD TO HORIZONTAL PANEL JOINT POP RIVETS CONTINUOUS KARRIER RAIL OUTSIDE CORNER TRIM INSIDE CORNER TRIM 1 3 4 " [44mm] POP RIVETS EVO MID-CLIP (TYP) CONTINUOUS BUTYL SEALANT AT PANEL JOINT 1 3 4 " [44mm] CONTINUOUS KARRIER RAIL INSIDE CORNER

INSULATED METAL KARRIER PANEL (IMP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S WITH WASHER VERTICAL SUPPORT AT 16" O.C. (NOT BY INGSPAN) CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM WEEP DRIP FLASHING WINDOW FIXED WITH FERRULES FIELD CUT FEMALE JOINTS WHERE REQUIRED WEATHER SEAL BY WINDOW INSTALLER WINDOW BY OTHERS STOREFRONT WINDOW HEAD

INTERNAL FINISH TO ARCHITECTS DESIGN VERTICAL SUPPORT AT 16" O.C. 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL JOINT INTERIOR CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS INSULATED METAL KARRIER PANEL (IMP) WINDOW BY OTHERS WEATHER SEAL BY WINDOW INSTALLER THROUGH AT KARRIER RAIL (BELOW) JAMB FLASHING W/ OPEN HEM RETURN 1 3 4 " STOREFRONT WINDOW JAMB

WEATHER SEAL BY WINDOW INSTALLER WINDOW SILL FLASHING 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER WINDOW BY OTHERS INTERNAL FINISH TO ARCHITECTS DESIGN Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S WITH WASHER INSULATED METAL KARRIER PANEL (IMP) VERTICAL SUPPORT AT 16" O.C. (NOT BY INGSPAN) STOREFRONT WINDOW SILL

1 3 4 " 1" 3" INSULATED METAL KARRIER PANEL (IMP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM 1 4 " - 14 "LOW PROFILE" THROUGH WEEP DRIP FLASHING FIELD CUT FEMALE JOINTS WHERE REQUIRED WEATHER SEAL BY INSTALLER DOOR, DOOR FRAME AND COMPONENTS FRAMED OPENING HEAD

DOOR, DOOR FRAME AND COMPONENTS INTERNAL FINISH TO ARCHITECTS DESIGN VERTICAL SUPPORT AT 16" O.C. 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL JOINT INTERIOR CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS INSULATED METAL KARRIER PANEL (IMP) WEATHER SEAL BY WINDOW INSTALLER THROUGH AT KARRIER RAIL (BELOW) JAMB FLASHING W/ OPEN HEM RETURN 1 3 4 " FRAMED OPENING JAMB

1 3 4 " 1" 3" INSULATED METAL KARRIER PANEL (IMP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM 1 4 " - 14 "LOW PROFILE" THROUGH WEEP FIELD CUT FEMALE JOINTS WHERE REQUIRED WEATHER SEAL BY INSTALLER CURTAINWALL SYSTEM BY OTHERS CURTAINWALL (FLUSH) HEAD

NOTCH THE KARRIER RAIL AS NECESSARY TO ALLOW FOR THE INSTALLATION OF THE CORNER TRIM AND/OR MEMBRANE MATERIAL INTERNAL FINISH TO ARCHITECTS DESIGN VERTICAL SUPPORT AT 16" O.C. WEATHER SEAL BY WINDOW INSTALLER 1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL JOINT INTERIOR CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS INSULATED METAL KARRIER PANEL (IMP) 1 3 4 " EPDM MEMBRANE BONDED TO FACE OF PANEL (BY OTHERS) CURTAINWALL (FLUSH) JAMB

WRAP MEMBRANE OVER PANEL FACE PARAPET CAP FLASHING TRIM CONTINUOUS BUTYL SEALANT PARAPET BLOCKING SLOPE TO PARAPET BACKER Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S INSULATED METAL KARRIER PANEL (IMP) PARAPET DETAIL

PARAPET CAP WRAP MEMBRANE OVER PANEL FACE PARAPET BLOCKING STAINLESS STEEL EVO MID-CLIP (TYP) Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER CONTINUOUS BUTYL SEALANT 1 4 " - 14 HEX HEAD S INSULATED METAL KARRIER PANEL (IMP) PARAPET DETAIL OVERHANG CAP

REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION FIP INSULATION AS REQUIRED 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER CONTINUOUS BUTYL SEALANT COUNTER FLASHING EAVE STRUT 1 4 " - 14 HEX HEAD S Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) EAVE ANGLE INSULATED METAL KARRIER PANEL (IMP) LOW EAVE DETAIL

REFER TO 900/1000 SERIES ROOF PANEL DETAILS FOR ADDITIONAL INFORMATION RAKE ANGLE FIP INSULATION AS REQUIRED 1 4 " - 14 HEX HEAD S WITH 1 1 8" BONDED WASHER CONTINUOUS BUTYL SEALANT RAKE FLASHING 1 4 " - 14 HEX HEAD S Z-GIRT TO SUIT (SET IN BUTYL SEALANT AT LOCATIONS) RAKE ANGLE INSULATED METAL KARRIER PANEL (IMP) RAKE DETAIL

1 4 " - 14 HEX HEAD S CONTINUOUS BUTYL SEALANT BOTH SIDES OF TRIM W/ MARRIAGE BEAD TO HORIZONTAL PANEL JOINT STRUCTURAL SUPPORTS CAP TRIM SET KARRIER RAIL IN BUTYL SEALANT AT LOCATIONS CONTINUOUS KARRIER RAIL BACKER ROD & SEALANT THROUGH AT KARRIER RAIL (BELOW) PANEL TERMINATION

(2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP MIN. 3" TRIM LAP TRIM END LAP

FIELD NOTCH HEM(S) AS REQUIRED MIN. 3" TRIM LAP (2) BEADS BUTYL SEALANT MIN. 3" TRIM LAP TRIM END LAP WITH HEMS