COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

Similar documents
LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Online Gas Analyzer / Monitor

testo 330 Flue gas analysis with increased convenience and safety

testo 340 Speed, power & precision in industrial combustion analysis.

Compact flue gas analyser: testo 300 M-I

GreenLine 6000 GreenLine 8000

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

New Measurement Engineering For Monitoring Emissions In Industry

Using the PPM2 Portable Trace Moisture Transmitter

Fine particle measuring system

GAS 3050P NDIR FLUE GAS

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Instruction Manual Dräger MSI EM200-s

testo 350 M testo 350 XL

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

Combustion Laboratory Unit C492

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

ICAC MARAMA Portable Emission Analyzers

AS950 ALL-WEATHER REFRIGERATED SAMPLER

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

EUROλYZER STx. Flue Gas Analyzer. BlueLine

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

The Leader in Performance Indoor Air Quality Measurements

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

MRU Instruments, Inc. Houston, Texas Tel.: (844) (Toll Free)

Flue gas analyzer. We measure it. testo 310 Flue gas analysis the easy way. Robust design for daily use. Battery lifetime up to 10 hours

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Data Logging Solutions from Lascar Electronics

TVOC Heated FID VE 7

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

The new testo 330 LL visualizes measurement data graphically

PORTABLE HARDNESS TESTING

Flue gas analysis brilliantly easy: testo 350

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

8 stream capability with dual mode (H 2 S & total Sulphur)

Gas concentrations in the air

Multifunction HVAC and IAQ Meter

Macro 900 WQS. Macro 900 Meter completely waterproof, simple to use, rugged for field use

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

Humidity/temperature measuring instrument

Controls and Software CHORE-TRONICS 2 Controls

TWIN LASER PARTICLE COUNTER

Instruction Manual. for. gskin U-Value Kit

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

Flue gas analyser. We measure it. testo 327 The special class entry instrument. Simple menu structure

Fpollutant-free zero air for analytical

FLUXUS F/G601 and F/G608

Ultrasonic Load Monitoring

NovaWAVE. A new category of Automated Microwave Digestion

Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification.

The. universal 3D Inspection reference. advanced 3D measurement software & solutions

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

Dräger MSI Variox-2 Combustion Gas Analysis

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

PORTABLE COATING THICKNESS GAUGE

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

S700 Modular Gas Analyzer. Measures more than 60 different gases

Carbon / Sulfur Analyzers

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Hydrant Pressure Monitoring Five of the most popular uses of Telog s HPR-31, hydrant pressure recorder, are:

ZK830 COUNTING SCALE. Precision counting scale for industrial use ZK830 COUNTING SCALE

Ambient Air Monitoring Systems

Multi-function VAC measuring instrument

Winweigh Plus. The versatile Windows software package with:

???? Spot Check Measurement Simple, accurate, reliable

6515 Series Measurement of CO2 in Flue Gases. A simple Katharometer-type measuring system for CO2 in flue gases as a guide to combustion efficiency

AlgaeTorch. The handy measurement instrument for rapid deployment. Fast and simple algae monitoring

INSTRUCTION & OPERATIONS MANUAL. E8500 Plus PORTABLE INDUSTRIAL INTEGRATED EMISSIONS SYSTEM COMBUSTION GAS ANALYZER

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

Inscale Measurement Technology Ltd Tel: Fax:

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit

Handheld Transit-Time Ultrasonic Flowmeter

Advances in NOx Compliance Testing with Portable Electrochemical Analyzers

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

testo 350 M/XL Short Operation Instruction Manual Rev. 11/03 Instrument Software Version 1.30

Model BF 260 Incubators Avantgarde.Line with forced convection

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

COp 28 CO2% 6.2. O2 CO Air Free. Eff X-Air. Temp. Fuel. Date Time C85 LONG LIFE EOS ANALYZER

Explore the future of osmometry. Multi-Sample Micro-Osmometer

Combustion Control Ltd.

PRODUCT CONFORMITY CERTIFICATE

Daikin LXE10E Reefer Machine

Infrared Temperature Measurement Systems. Designed for the Aluminium Extrusion Industry

4Ch Real time / Duplex LCD Combo DVR

Model BF 720 Incubators Avantgarde.Line with forced convection

PRODUCT CONFORMITY CERTIFICATE

Comp. Tag No. Component Title Options Installation Detail No.

Flue gas analyzer. We measure it. testo 327 The special class entry instrument. Simple menu structure. 4-line segment display with LED illumination

Transcription:

High /H comp NO NOx 2 LANM 4 www.lancom4.com NO2 2 H2S SO2 CXHY Portable Flue Gas Monitoring

LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available. In excess of two thousand Lancom analysers are in use today, in a wide range of applications - all subjected to very different measurement conditions. Features Monitoring of up 17 measurement parameters Up to 9 simultaneous gas measurements in a single instrument Weighs only 6 kg (13 lbs) Robust, industrial design Wake and Sleep, semi-continuous operation mode Range of user selectable options Data acquisition & analysis software Simple field upgrade Meets ASTM D-6522 with Dry Sampler probe USB Communications Support Benefits one instrument to meet all requirements User selectable easily carried around plant for daily use in the harshest plant environments for periodic unattended operation ideally matched to application requirements capture, manipulate, and report data on your PC add features and options as and when required report generation to recognised standards Simple interface to PC and data transfer - supports USB memory sticks S C X H Y H 2 Comp NO High NO X 2 The world s most versatile portable flue gas analyser H 2 S

Convenient catchpot visible and accessible Clip-in filters - visible and quick to change The side-mounted catchpot is both fully protected and highly visible for rapid checking, removal and emptying. The chemical and particulate filters are mounted on the side of the instrument. Visible inspection and replacement is straightforward. The rugged case design protects all components from damage. High Colour Display Straightforward servicing New high resolution colour display supports a multilingual, simple user interface. Service is simple via the menu driven software. Flue gas & ambient temperature Setup and measure within minutes The analyser takes a direct thermocouple temperature measurement of the flue gas, and has an ambient temperature sensor fitted. Simply switch on, an automatic zero calibration is performed by the analyser. Plug in the sample probe and take real-time gas readings in a matter of minutes. Self diagnostic checks are run continuously on calibration status and battery life. These are required for making accurate combustion efficiency calculations. Easy access sensors Each sensor is installed in its own unique position. Replacing a sensor is a simple process and takes only a few minutes. Unclip the side panel for access, swap the sensor and re-calibrate. Direct 2 Measurement capability Data Logging The infrared sensor used in the Lancom 4 enables direct measurement of 2 in flue gas. The combination of this 2 sensor with the measurement capability offered by the flow probe, can give quantitative information on greenhouse gas emission. Internal data logging makes it easy to record measured gas concentration. After a measurement run, simply download the data to a USB memory stick to transfer to PC. The 64MB of available memory means an almost unlimited number of log records can be stored. Long life rechargeable battery Automatic Sensor Protection Rechargeable batteries give up to 8 hours continuous operation. A power supply cable is is supplied for battery recharging. Auto Purge of sensors on system shutdown clears system of corrosive flue gases. overrange protection Automatically purges low sensor and switches to high range measuring mode, if high levels of are encountered.

How the analyser works 1 6 3 5 2 4 7 8 11 H CXHY H2S NO2 2 10 L O2 NO SO2 9 Key 1. Integral sample conditioning Sample Gas Inlet 2. Catchpot for condensate 3. Particulate Filter 4. Pressure Sensor 5. Air Input 6. Sample Pump 7. Expansion Chamber 8. Chemical Filter 9. Purge Pump 10. Exhaust 11. Flow Probe Inlet The gas sample is drawn into the analyser via a sample probe and hose connected to the input connection on the side panel of the analyser. The sample enters the water catchpot where residual water is removed. The sample gas is then passed through a 0.1 micron particulate filter. Filtering out damaging chemicals prolonging sensor life The sample gas is routed to the sensor manifolds, after removing flow and pressure variations. To ensure that the and CXHY sensors are not poisoned by other gases the sample gas is fed through a chemical filter prior to being routed to these sensors. This action ensures prolongs sensor life and improves measurement accuracy. Automatic Sensor protection To protect the sensor from excessive levels of (normally levels >2000ppm), the system automatically switches to the high range sensor (up to 4000ppm). The low sensor is then automatically purged using a dedicated pump which blows ambient air to protect the sensor, ensuring rapid recovery time and maximum sensor life. Sensor accuracy and longevity View showing measurement sensors The Lancom 4 performs a zero calibration every time it is switched on, and purges the sensors with ambient air before switching off. This ensures maximum accuracy and sensor longevity.

Selecting the analyser The following features are standard on all instruments: Standard Sample Probe Data Logging RS 232 or RS 422 Serial Communications Interface The user selects which gases (between 3 and 9) and then the options that are required for their application. (See list below) Options Draft Measurement Flow Measurement Smoke Measurement Range of Sample Probes Insight Data Acquisition Software system Analogue outputs Wake and Sleep facility (Semi-continuous monitoring) Language display options Description Internal stack pressure in hpa or inches water gauge Flue gas velocity, flow rate and mass emissions rate Readings of Smoke spot number (Bacharach Smoke scale) Smoke, Flow, DrySampler* and High Temperature Simple-to-use Windows reporting software (16 current loops, independently user configurable) Takes gas measurement at user defined intervals (see below) English, French, German, Italian, Spanish & Chinese *US Patent No. 6782767 **Bacharach scale Sample Probes A wide range of sample probes suitable for specific application and measurement requirements are available. Request Information ref. PDS 198 DrySampler Probe High Temperature Probe Standard Probe Smoke Probe Flow Probe H 2 Comp C H SO Semi-continuous Monitoring Wake and Sleep monitoring takes gas measurements X Y 2 at user defined intervals. This is achieved by cyclically sampling and logging gas concentrations over a period of time. (alternate wake and sleep phases). User settings include wakeup interval, number of samples between wakeup, sample interval and first wakeup. NO High NO X 2 leading the way in portable flue gas monitoring H 2 S N

Measurement Specifications Sensor Minimum Range Maximum. Range # Accuracy % of range Resolution 25% v/v 30% v/v ±1% 0.1% v/v (low) 100 ppm 10000 ppm ±2%* 0.1 ppm (H 2 compensated) 100 ppm 4000 ppm ±2%* 0.1 ppm (high) 4000 ppm 10 % v/v ±2%* 0.1 ppm S 100 ppm 5000 ppm ±2%* 0.1 ppm NO 100 ppm 5000 ppm ±2%* 0.1 ppm N 100 ppm 1000 ppm ±2%* 0.1 ppm 2 ** 10% v/v 25% v/v ±3%* 0.1% v/v Hydrocarbons (C x H y ) 5% v/v 5% v/v. Application dependent 0.1% v/v Flue Gas/Ambient Temperature Measured Draft ± 50 h Pa / 20 Water Gauge *** Flow (velocity) 1 to 50 m/s Note: Special ranges are available *Calibration per ASTM D-6522 or LAND factory procedure **True measurement if sensor fitted (calculated if not) ***Reduced to ± 25 h Pa / 10 Water Gauge when used with flow probe # Operating at maximum possible range may affect sensor life and accuracy Combustion & Environmental calculations Combustion efficiency Loss Excess Air 2 (where no sensor fitted) Oxygen normalisation Total NO X Wet or dry basis Automatic conversions - ppm, mg/m 3, lb/mmbtu, ng/j Sensor Types Lancom analysers use the following sensors in order to measure gas concentration levels. Sensor Type Gas Electrochemical,, High, H 2 compensated,, NO, N, S and H 2 S Infrared 2 Pellistor/Catalytic C X H Y S C H X Y H2, Comp NO High NO X 2 capable of monitoring up to 9 different gases simultaneously H S

Combustion & Environmental Monitoring Suitable for most applications where the flue gas temperature is below 600 C / 1112 F. Suitable for applications where the sample gas temperature is between 600 C and 1400 C / 1112 F and 2552 F. For measuring smoke density simultaneously with flue gas analysis. For measuring the sample gas flow rate, and calculating mass emissions levels. Proven revolutionary design to dry the flue gas at the sample point. Independently verified by the UK National Physical Laboratory, Report No. QE21/02/1042. Selection of probe length options Range of flexible hose lengths Integral flue gas temperature thermocouple (except HT probe) Standard replaceable particulate filter (Standard and DrySampler probes only) Probe Length Options (m) Length Options (ft) Max. Flue Gas Temp. Options/Accessories Standard Probe 0.3, 1.0, 1.5, 2.0, 3.00 0.9, 3.3, 5, 6.6, 9.8 600 C / 1112 F 3 m or 10 m / 10 ft or 33 ft hose available High Temp. Probe 0.5, 1.0, 1.5 2.0 1.6, 3.3, 4.9, 6.6 1400 C / 2552 F 3 m / 10 ft hose available Smoke Probe 0.3, 0.75, 1.0 1, 2.4, 3.2 600 C / 1112 F 3 m / 10 ft hose, Filter Papers, Bacharach Chart and In-line Flowmeter Flow Probe 0.7, 1.2, 2.2, 3.0 2.3, 3.9, 7.2, 9.8 600 C / 1112 F 3 m or 10 m / 10 ft or 33 ft hose DrySampler 0.3, 1.0, 1.5, 2.0, 3.0 0.9, 3.3, 5, 6.6, 9.8 600 C / 1112 F 3 m or 10 m / 10 Probe ft or 33 ft hose available Insight is a Windows based data acquisition software program, used for logging measurement data directly from a LANM portable gas analyzer. Data can be analyzed either as it is collected in real time, or during review of logged data. A range of statistical and graphical tools allow the user to perform measurements, manipulate, report, present and print data. Trace Graph Frequency Distribution Specifications - lancom 4 Display: Keypad: Indicators: Power Supply Ambient Temperature: Case: Dimensions: Weight: Standard Accessories: Options: Full function colour LCD with backlight, wide QVGA display Tactile membrane (integral with display) function keys and cursors LED type for ON (Power), Stand-by, Charge, Batt., Fault 95-265 V a.c. ±10%, 50-60 Hz, 30 Watts. Battery, rechargeable lead-acid (internal). Typical 8 hour operation, dependent on options fitted -5 C to 45 C (+23 F to 113 F) Medium density blended polyethylene 453 x 120 x 245 mm (17.8 x 4.7 x 9.6 inches) 6 kg (13 lb) Integral water catchpot and filters, Rechargeable lead acid battery (internal), Battery Charger supply, Probe handle, Hose and Probe pipe (Lengths listed below under options), Data logging Min of 3 to max 9 gases in total, from a selection of 9 gases Probe length options - 0.3, 1.0, 1.5, 2.0, 3.0m/1, 3.3, 5, 6.5, 10ft Alternative probes available - Refer to Data Sheet Reference PDS198 for details Hose length options - 3 m/10 ft or 10 m/33 ft Draft Measurement Flow Measurement, probe length options - 0.7, 1.2, 2.2, 3.0 m/2.3, 3.9, 7.2, 9.8 ft Smoke Measurement, probe length options - 0.3, 0.75, 1.0 m/1, 2.4, 3.2 ft Insight Data Acquisition Software system - Refer to Data Sheet Reference PDS205 for details Analogue outputs (16 current loops, independently configurable) Wake and Sleep facility (Semi-continuous monitoring) Language display options - English, French, German, Italian, Spanish & Chinese, others available Other related data sheets LANM Portable Flue Gas Analyzers Insight Data Acquisition & Analysis Software SAMPLE PROBES The LANM range of portable flue gas analyzers feature a full choice of sample probes suitable for a wide range of applications. Standard Sample Probe High Temperature Sample Probe Smoke Probe Flow Probe DrySampler Probe All LANM sample probes feature: Features Real-time data display, capture and storage Range of display formats Integrated statistical analysis functions Range of calculations User definable alarms with event monitoring User-programmable averaging algorithms Export data to Microsoft Excel or text file Simple to use Windows-based software Range of user-configurable sample triggers Local or remote operation Ideal for USEPA CTM-034 reporting A simple tool for on-site record keeping, analysis and reporting Lancom Sample Probes - further information Insight Data Acquisition System - further information Land Instruments International Ltd Dronfield S18 1DJ England Email: land.combustion@ametek.co.uk www.landinst.com Tel: +44 (0) 1246 417691 Fax: +44 (0) 1246 290274 Combustion & Environmental Monitoring AMETEK Land, Inc. 150 Freeport Rd Pittsburgh, PA 15238 U.S.A. Email: combsales@ametek.com www.ametek-land.com Tel: +1 (412) 828 9040 Fax: +1 (412) 826 0399 For a full list of international offices, please visit www.landinst.com www.lancom4.com Applies in the UK Copyright 2011 Land Instruments International Continuous product development may make it necessary to change details without notice. PDS242/0111