LCA on HFC-365mfc and high performance rigid polyurethane foams

Similar documents
EPD. 3 rd P A R T Y V E R I F I E D. ECO EPD Ref. No.: Owner: ISOKLINKER ApS No.: MD EN Issued: Valid to:

HCFC REPLACEMENT IN FOAMS OORG RECOMMENDATIONS

HCFC Phase-out in China for Rigid Polyurethane Foam Applications

ENVIRONMENTAL PRODUCT DECLARATION In accordance with EN and ISO Isover Roof N 160 mm. Realization data: Version:

Environmental Product Declaration

LIFE-CYCLE ASSESSMENT (LCA) FOR SPRAY POLYURETHANE FOAMS

This EPD complies with the Building Envelope Thermal Insulation Product Category Rule (PCR), version 1.0 by Underwriters Laboratory (UL).

Same on the outside, different on the inside ODP. Insulation GLOBAL WARMING POTENTIAL AND OZONE DEPLETION POTENTIAL OF DIFFERENT PIR INSULATION

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

K5 External Wall Board

Paroc Insulation, product group with density kg/m³ Product

K5 External Wall Board

Eco-profiles and Environmental Product Declarations of the European Plastics Manufacturers

Ortiz Oscar 1, Castells Francesc 2, Sonnemann Guido 3

EPD. Environmental Product Declaration

ISOVER Rolls R=1 ENVIRONMENTAL PRODUCT DECLARATION. Program holder and publisher. Declaration number. Issue date. Valid to

2015 Japan Technology Summit Yokohama, September Honeywell Blowing Agent for LNG Insulation Katsuyuki Matsui, Fluorine Products, Honeywell

K8 Cavity Board. Insulation CAVITY WALL INSULATION

Life Cycle Assessment of Sports Surfaces

Your reference for Recticel PIR insulation.

ENVIRONMENTAL PRODUCT DECLARATION

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

Environmental product declaration. KONE MonoSpace Special

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

Thermal Laminate Board.

TR26 LPC/FM / TR27 LPC/FM

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

Measuring environmental sustainability: The use of LCA based building performance indicators

Product Environmental Profile

Holistic optimisation of noise reducing devices

ENVIRONMENTAL PRODUCT DECLARATION In accordance with EN and ISO 14025

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

Environmental Product Declaration Structural Steel according to EN 15804

Environmental Product Declaration (EPD) According to ISO14025, BS EN ISO 15804:2012 and International EPD System PCR 2012:01

EPD. 3 r d P A R T Y V E R I F I E D. Owner: Gamle Mursten ApS No.: ECO EPD: MD EN Issued: Valid to:

ENVIRONMENTAL PRODUCT DECLARATION as per /ISO 14025/ and /EN 15804/

Environmental Product Declaration (EPD) According to ISO14025, BS EN ISO 15804:2012 and International EPD System PCR 2012:01

EPD FOR COPPER EPD STAKEHOLDER CONFERENCE 15TH MAY 2012 STOCKHOLM WATERFRONT CONGRESS CENTRE, SWEDEN.

ECOWORX CARPET TILE WITH ECOSOLUTION Q FACE FIBER

ENVIRONMENTAL PRODUCT DECLARATION AXIOM

Label Eco-Efficiency Analysis Pitched Roof Insulation Above Rafter (Northern Italy)

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

ENVIRONMENTAL PRODUCT DECLARATION as per ISO 14025

Product Data Sheet. Product: Benchmark Wall Liner System

8 a Conferenza di Responsible Care. La sostenibilità dell industria Chimica, della sua filiera e dei servizi indotti

Environmental credentials. Energy efficiency and environmental protection with KIMMCO glass mineral wool

Life Cycle Assessment and Life Cycle Costing of the World s Longest Pier:

INNOVIA APM 300. Environmental Product Declaration

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

PRODUCT DISCLOSURES FOR SUSTAINABLE BUILDING PROGRAMS

ENVIRONMENTAL PRODUCT DECLARATION STEEL DECK STEEL ROOF DECK STEEL FLOOR DECK

Think Blue. The up! Environmental Commendation Data Sheet

RH Mereo 220 with armrests Product

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

Insulation. A4/6 AW2242 Issue 1 Oct Kingspan Insulation

D W O CH C E H M E ICA C L A CO C M O PA P N A Y N Y

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

INSULATION AGING & GREEN FOAM

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

ENVIRONMENTAL PRODUCT DECLARATION Kerto LVL

Solutions. Main Headings Third Issue July Insulation DON T COMPROMISE ON THERMAL PERFORMANCE, FIRE PERFORMANCE AND ENVIRONMENTAL RESPONSIBILITY

The functional unit: provision of support for an UPS unit (weighing between 13 kg to 110 kg) within a server rack or enclosure for 20 years

EPD - ENVIRONMENTAL PRODUCT DECLARATION

FABRICATED HOT-ROLLED STRUCTURAL SECTIONS

AFA-L1, a Low Global Warming Potential Blowing Agent for Cold Chain Applications

LCA DATABASE OF STEEL BUILDING TECHNOLOGIES

Polyrey HPL Compact Laminate

Sustainability aspects, inventory, comparisons

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Product Environmental Profile DT A 16A/C 1P+N

ENVIRONMENTAL PRODUCT DECLARATION for the LoFric Hydro-Kit catheter system. Verified by: DNV (Det Norske Veritas Certification AB)

HÅG Capisco ENVIRONMENTAL PRODUCT DECLARATION in accordance with ISO Scandinavian Business Seating AS

INSULATED PANEL OVERVIEW

UNITED NATIONS FRAMEWORK CONVENTION ON CLIMATE CHANGE

Further Development of FEA-1100: a Low GWP Foam Expansion Agent

Product Environmental Profile

INSULATED PANELS. Cold Store

ENVIRONMENTAL PRODUCT DECLARATION

SECURITRON AQD6 SERIES POWER SUPPLY

Foams. Coordinating Lead Author Paul Ashford (United Kingdom)

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

Cold Rooms Kide

Insulated Roof & Wall Panels. Foilback KS1000 FB Insulated Roof Panels. Product Data Sheet

ENVIRONMENTAL PRODUCT DECLARATION as per /ISO 14025/ and /EN 15804/

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Ductslab and Ductwrap

Sectional garage doors. A product of ALPHA Deuren International BV

Product Environmental Profile

Thermablok Aerogel Insulation Blanket Thermablok Aerogel Blanket

ENVIRONMENTAL PRODUCT DECLARATION as per /ISO 14025/ and /EN 15804/

Environmental Product Declaration Aluminium Door Systems. February 2017

LIFE CYCLE ASSESSMENT OF A BIOREACTOR AND AN ENGINEERED LANDFILL FOR MUNICIPAL SOLID WASTE TREATMENT

PowerDeck F. PIR insulation for Warm Flat Roofs. Product Guide

ENVIRONMENTAL PRODUCT DECLARATION According to ISO EUMEPS

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

Environmental Product Declaration Aluminium Window System

Transcription:

page 1 LCA on HFC-35mfc and high performance rigid polyurethane foams H. Krähling, Solvay Management Support GmbH L. Zipfel, Solvay Fluor und Derivate GmbH Hans-Böckler-Allee, D-3173 Hannover even though > 9 % reduction of the ODP as compared to R11 was achieved have to be withdrawn from the markets in the EU, USA, and Japan between 3 and. The motivation for this study Adequate temperatures in our working and living spaces keep as healthy and are a part of our living comfort that we do not want to miss. On the other hand, efficient housekeeping with natural resources as well as avoiding unacceptable overloads of our environment with emissions and waste have become an ever increasing demand during the last decades. Therefore, we are challenged to find solutions which satisfy our needs and at the same time prove to be environmentally responsible and economically viable. Third generation hydrofluorocarbons (HFC) like 35mfc (1,1,1,3,3-pentafluorobutane), which do not affect the ozone layer at all, are at present developed to fill the gap of high-performing blowing agents. Reflecting the importance of environmental aspects, it is obvious that insulation products manufactured by using third generation blowing agents have to prove their environmental competitiveness to achieve market acceptance. In this context information is required for the dialog with all stake holders as well as to support company internal decision making. Thermal insulation can contribute significantly to reach these goals, PU-rigid foams being amongst the most efficient thermal insulation materials known so far. Halogenated hydrocarbons have proven to be the most effective blowing agents in terms of achievable insulation performance of PU-rigid foam products. However, the use of fully halogenated (first generation) chlorofluoro-hydrocarbon (CFC) blowing agents like R11 had to be stopped because of the high ozone depletion potential (ODP) of such compounds. Partially halogenated (second generation) hydrochlorofluorocarbon (HCFC) blowing agents like 11b Therefore, Solvay Fluor und Derivate decided to commission this life cycle assessment (LCA) to support the application development and the market positioning of 35mfc as a blowing agent for PU-rigid foams. Elastogran, Kingspan and Synthesia as experts and stake holders in the PU-industry were invited and accepted to join the project as partners. The goals of the study The project partners jointly agreed upon the following goals of the study:

page Elaborate a full LCA (complete insulation systems, comprising all relevant environmental aspects no restriction to single selection criteria) comparing different blowing agents in selected PU-rigid foam insulation products to support application development of 35mfcblown PU-rigid foam products positioning of 35mfc-blown PU-rigid foam products on the market. The acceptance of the study is regarded as a key issue. Therefore the study is performed (a) in collaboration with partners who participate in the production chain of thermal insulation and (b) according to the respective ISOstandards (ISO EN 1 series) including an external critical review. The results of the study are published in a full report as well as in a summary report available from any of the project partners. The scope of the study The PU-rigid foam thermal insulation products under study are 11b-, water/co -, 35mfc-blown sprays for a warm flat roof of an industry building 11b-, n-pentane, 35mfc-blown boards for cavity walls and warm pitched roofs of domestic houses. The functional unit for the investigations is 1 m of insulated area with PU-rigid foam products of specific thicknesses. The system boundaries of the study encompass the complete life cycle of the products; recycling/disposal options are dealt with separately, however. Investigations refer to the situation in Germany and to current technologies. The impact assessment is performed regarding those environmental categories which are considered particularly relevant for sustainable development today and for the product systems investigated, i.e. cumulative energy demand, requirement of non regenerative (non-fuel) material resources, water demand, global warming potential (GWP), ozone depletion potential (ODP), acidification potential (AP), nutrification potential (NP), photochemical ozone creation potential (POCP), potentially hazardous and non-hazardous waste. Key settings for standard scenarios are given in the table below. sprays boards spec. weight [kg/m 3 ] 3 facing no facing foam thickness [m] roof:. λ-value [mw/(m*k)] blowing agent emissions during production [%] service life for calculation [years] blowing agent emissions during service life [% or %/a] 11b: 9 H O/CO 35 35mfc: 3 alu-foil/kraft paper/alu-foil (7µm each) on both sides roof:.1 wall:.5 11b: 1 n-pentane: 35mfc: 15 5 5 5 1 st year: 5, following years: 1.. degree days [K*d/a] 717 35 heating system oil heating Mix (Germany)

page 3 The key settings for standard scenarios vary throughout Europe, e.g. in Spain sprays are used with lower density (5 kg/m 3 ) or different facings for boards (5 µm aluminium foil instead of trilaminate facings) are applied in different countries. In addition to calculating standard scenarios, sensitivity analyses are performed for all aspects and settings which may influence the results of the study, i.e. service life, degree days, thermal conductivity of PU-rigid foams, diffusion rate of blowing agents during service life, thickness of the PU-rigid foams, heating systems and allocations of inputs and outputs for production steps which give raise to more than one product. During the use phase the environmental effects resulting directly or indirectly (e.g. acquisition of fuels) from necessary heating to compensate thermal losses determine most of the environmental aspects investigated by at least 75 % and up to 99 %. Blowing agent losses during the use phase contribute only to a limited extend to GWP (11b and 35mfc: 1 7 %) and POCP (n-pentane: 1 %). As expected losses of 11b during production of foams and during the use phase of such products determine the ODP all other product systems show only very low ODP-values due to unspecified emissions e.g. from power plants. The Results General findings Regarding the complete life-cycle of the PU-rigid foam sprays and boards investigated, the use phase of the products clearly dominates all environmental criteria investigated with the exception of the parameter water demand. Thus, the production of the products itself is only of marginal importance (figure 1and ), with the exception of water demand and NP (some products) and ODP (only 11bblown products). The contribution to the overall environmental profiles caused by the recycling/disposal of PU-rigid foam sprays and boards was found to be marginal ( % or less) when considering waste incineration with energy recovery (which completely destroys blowing agents still present in the foams). Otherwise blowing agents emitted in the course of recycling/disposal may substantially worsen the environmental performance particularly regarding 11b- (for ODP and for GWP), 35mfc- (for GWP), and n-pentane- (for POCP) blown products.

page Production Thermal Energy (oil) Diffusion (1 years) Production Thermal Energy (oil) Diffusion Production Thermal Energy (oil) Diffusion 9 55 5,5,5 [MJ / m board / 5 years] 7 5 3 [kg CO -equi. / m board / 5 years] 5 35 3 5 15 1 [kg ethene-equi. / m board / 5 years],,35,3,5,,15,1 1 5,5, 11b-spray (/9/,) HO/CO-spray (/35/,) 35mfc-spray (/3/,) 11b-spray (/9/,) HO/CO-spray (/35/,) 35mfc-spray (/3/,) 11b-spray (/9/,) HO/CO-spray (/35/,) 35mfc-spray (/3/,) Figure 1: Cumulative energy demand, GWP, and POCP for thermal insulation systems with different PU-rigid foam sprays Shown are standard scenarios for sprays without facings. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)], and the thickness in [m]. For key settings see preceding table. (1 years) Production Thermal Energy (Mix ) Diffusion Production Thermal Energy (Mix ) Diffusion Production Thermal Energy (Mix ) Diffusion [MJ / m board / 5 years] 13 1 11 1 9 7 5 3 1 11b-board roof (3/1/,1) n-pentane-board roof (3//,1) 35mfc-board roof (3//,1) 11b-board wall (3/1/,5) n-pentane-board wall (3//,5) 35mfc-board wall (3//,5) [kg CO -equi. / m board / 5 years] 7 5 3 1 11b-board roof (3/1/,1) n-pentane-board roof (3//,1) 35mfc-board roof (3//,1) 11b-board wall (3/1/,5) n-pentane-board wall (3//,5) 35mfc-board wall (3//,5) [kg ethene-equi. / m board / 5 years],5,5,,35,3,5,,15,1,5, 11b-board roof (3/1/,1) n-pentane-board roof (3//,1) 35mfc-board roof (3//,1) 11b-board wall (3/1/,5) n-pentane-board wall (3//,5) 35mfc-board wall (3//,5) Figure : Cumulative energy demand, GWP, and POCP for thermal insulation systems with different PU-rigid foam boards Shown are standard scenarios for boards with tri-laminate facings. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)], and the thickness in [m]. For key settings see preceding table.

page 5 Comparison of PU-rigid foam sprays for the thermal insulation of a flat warm roof In the standard scenario (figure 1) the 35mfc-blown spray shows an app. % lower GWP and approx. 15 % lower values for all other criteria as compared to the water/co -blown spray. As compared to the 11b-blown spray the 35mfc-blown spray is found to cause marginally higher ( %) environmental effects, avoiding however the 11b-born ODP. Sensitivity analyses reveal: The environmental advantages of the 35mfc-blown spray increases in absolute terms when increasing the service life of the products or under conditions requiring more heating. Assuming an increase in blowing agent losses during the service live of the sprays will only affect the parameters GWP, ODP and POCP (i.e. the advantages of the 35mfc-blown product for the other parameters remain valid). 35mfc-losses of approx..5 %/a would result in a total GWP that equals the respective value for the water/co -blown spray (figure 3); such losses however exceed empirical values. Increasing the thickness equally for all sprays will not substantially alter the results except for the GWP for which the reduction of heating generated CO is counterbalanced by GWP relevant (1 years) 11b-spray (/9/,) HO/CO-spray (/35/,) 35mfc-spray (/3/,) 11b-spray (/9/,) HO/CO-spray (/35/,) 35mfc-spray (/3/,) 57,75 [kg CO -equi. / m spray / 5 years] 5 55 5 53 5 51 5 9 7 [kg ethene-equi. / m spray / 5 years],5,55,5,35,5,15,5,395 5,35,, 1, 1,, 3,,, 1, 1,, 3, diffusion [%/year] diffusion [%/year] Figure 3: Dependence of the GWP and POCP on variations in the diffusion rates of different PU-rigid foam sprays Shown are standard scenarios with varying diffusions rates of blowing agent for sprays without facings. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)], and the thickness in [m]. For key settings see preceding table.

page to the water/co- blown spray [%] 1 1 1 1 1 11b-spray (/9) 35mfc-spray (/3),,3,,5 thickness of the spray [m],,7 to the water/co-blown spary [%] (1 years) 15 1 5-5 -1-15 - 11b-spray (/9) 35mfc-spray (/3),,3 Figure : Dependence of the cumulative energy demand, GWP and POCP on variations in the thickness of 35mfc- and 11b-blown PU-rigid foam sprays relative to the water/co -blown spray Shown are standard scenarios with varying thicknesses for sprays without facings. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)]. For key settings see preceding table. Positive values represent environmental advantages while negative values stand for environmental disadvantages.,,5, thickness of the spray [m],7 to the water/co-blown spray [%] 1 1 1 1 1 11b-spray (/9) 35mfc-spray (/3),,3,,5, thickness of the spray [m],7 flat roof, non-insulated (oil) 35mfc-spray (/3/,) (oil) flat roof, non-insulated (gas) 35mfc-spray (/3/,) (gas) (1 years) flat roof, non-insulated (oil) 35mfc-spray (/3/,) (oil) flat roof, non-insulated (gas) 35mfc-spray (/3/,) (gas) flat roof, non-insulated (oil) 35mfc-spray (/3/,) (oil) flat roof, non-insulated (gas) 35mfc-spray (/3/,) (gas) [MJ / m spray] 1 1 1,5 1 1,5 [kg CO -equi. / m spray] 1 9 7 5 3 1,5 1 1,5 Figure 5: Cumulative energy demand, GWP, and POCP for a non-insulated and an with a 35mfcblown spray insulated flat warm roof with different heating systems during the first two years of use Shown are standard scenarios for different heating systems for sprays without facings. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)]. The source for the thermal energy is either a central oil or gas heating system. For key settings see preceding table. [kg ethene-equi. / m spray],9,,7,,5,,3,,1,,5 1 1,5 emissions of blowing agents. Below a thickness of approx..5 m the 35mfc-blown spray shows a lower GWP as compared to the water/co - blown spray. Above this break-even point the 35mfc-blown spray shows a higher GWP as compared to the water/co -blown spray, keeping however its environmental advantages in the other parameters (figure ). To achieve the insulation performance of the 35mfc-blown spray the thickness of a water/co -blown spray has to be increased by approx. 17 %.

page 7 For u-values higher than. W/(m * K) the GWPs for all thermal insulation systems regarded are equally competitive (i.e. differences are below approx. 1 %). Gas heating (instead of oil heating) substantially reduces environmental effects irrespective of the blowing agent applied. The 35mfc-blown spray keeps its advantageous environmental profile as compared to the water/co - blown spray. The higher cumulative energy demand as well as the higher contribution to the GWP and POCP of an insulated flat warm roof as compared to a non-insulated roof are compensated by the lower transmission losses of the insulated flat warm roof within the first year of use irrespective of the heating system (figure 5). Comparison of PU-rigid foam boards for the thermal insulation of a pitched warm roof or a cavity wall In the standard scenarios (figure ) the 35mfc-blown boards show a similar GWP (roof) or an app. % lower GWP (wall) and approx. 1 % lower values for all other criteria as compared to the respective n-pentane-blown boards. As compared to the 11b-blown boards the 35mfc-blown boards are found to cause marginally higher ( 5 %) environmental effects, avoiding, however, the 11b-born ODP. (1 years) 11b-board roof (3/1/,1) n-pentane-board roof (3//,1) 35mfc-board roof (3//,1) 11b-board roof (3/1/,1) n-pentane-board roof (3//,1) 35mfc-board roof (3//,1) 11b-board wall (3/1/,5) n-pentane-board wall (3//,5) 35mfc-board wall (3//,5) 11b-board wall (3/1/,5) n-pentane-board wall (3//,5) 35mfc-board wall (3//,5) 75 [kg CO -equi. / m board / 5 years] 7 5 55 5 5 35 [kg ethene-equi. / m board / 5 years],5,375,35,75,5 3,1,,3,,5 diffusion [%/year],175,1,,3,,5 diffusion [%/year] Figure : Dependence of the GWP and POCP on variations in the diffusion rates of different PU-rigid foam boards Shown are standard scenarios with varying diffusions rates of blowing agent for boards with tri-laminate facings. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)], and the thickness in [m]. For key settings see preceding table.

page Sensitivity analyses reveal: The environmental advantages of 35mfc-blown boards increase in absolute terms when increasing the service life of the products or under conditions requiring more heating. Assuming an increase in blowing agent losses during the service life of the sprays will only affect the parameters GWP, ODP and POCP (i.e. the advantages/competitiveness of 35mfc-blown products with the other parameters remain valid). 35mfc-losses of approx.. %/a (roof) or 1 %/a (extrapolated; wall) would result in a total GWP that equals the respective value for the n-pentane- 11b-board roof (3/1) 35mfc-board roof (3/) 13 1 (1 years) 11b-board roof (3/1) 35mfc-board roof (3/) 1 11b-board roof (3/1) 35mfc-board roof (3/) to the n-pentane-blown board [%] 1 11 1 9 7 5 3 1,5,,7,,9,1,11,1,13,1,15 1 - - - - -1-1 -1-1 11b-board wall (3/1) 35mfc-board wall (3/) (1 years) 11b-board wall (3/1) 35mfc-board wall (3/) 11b-board wall (3/1) 35mfc-board wall (3/) 13 13 1 to the respective n-pentane PU-rigid foam [%] 1 11 1 9 7 5 3 1 to the respective n- pentane PU-rigid foam [%] 1 11 1 9 7 5 3 1 13 1 11 1 9 7 5 3 1,15,,5,3,35,,5,5,55,,15,,5,3,35,,5,5,55,,15,,5,3,35,,5,1 to the n-pentane-blown board [%],5,,7,5,55,,,9,1,11,1,13,1,15,1 to the n-pentane-blown board [%] 1 1 1 1,5,,7,,9,1,11,1,13,1,15,1 to the respective n- pentane PU-rigid foam [%] Figure 7: Dependence of the cumulative energy demand, GWP and POCP on variations in the thickness of 35mfc- and 11b-blown PU-rigid foam boards relative to the n-pentane-blown boards Shown are standard scenarios with varying thicknesses for boards with tri-laminate facings. The upper and the lower set of figures show the results for a pitched warm roof and a cavity wall, respectively. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)]. For key settings see preceding table. Positive values represent environmental advantages while negative values stand for environmental disadvantages.

page 9 blown boards (figure ); such losses are equal to or exceed empirical values. Increasing the thickness equally for all boards will not substantially alter the results except for the GWP for which the reduction of heating generated CO is counterbalanced by GWP relevant emissions of blowing agents. Below a thickness of approx..9 m the 35mfc-blown board for the pitched warm roof shows a lower GWP as compared to the n-pentane-blown board. Above this break-even point the pitched roof, non-insulated (Mix ) 35mfc-board roof (3//,1) (Mix ) pitched roof, non-insulated (gas) 35mfc-board roof (3//,1) (gas) pitched roof, non-insulated (electricity) 35mfc-board roof (3//,1) (electricity) (1 years) pitched roof, non-insulated (Mix ) 35mfc-board roof (3//,1) (Mix ) pitched roof, non-insulated (gas) 35mfc-board roof (3//,1) (gas) pitched roof, non-insulated (electricity) 35mfc-board roof (3//,1) (electricity) pitched roof, non-insulated (Mix ) 35mfc-board roof (3//,1) (Mix ) pitched roof, non-insulated (gas) 35mfc-board roof (3//,1) (gas) pitched roof, non-insulated (electricity) 35mfc-board roof (3//,1) (electricity) 5 3, [MJ / m board] 5 35 3 5 15 1 5 [kg CO -equi. / m board] 5 15 1 5 [kg ethene-equi. / m board],7,,5,,3,,1,,,5,5,75 1, 1,5 1,5,,,5,5,75 1, 1,5 1,5,,,5,5,75 1, 1,5 1,5, cavity-wall, non-insulated (Mix ) 35mfc-board wall (3//,5) (Mix ) cavity-wall, non-insulated (gas) 35mfc-board wall (3//,5) (gas) cavity-wall, non-insulated (electricity) 35mfc-board wall (3//,5) (electricity) (1 years) cavity-wall, non-insulated (Mix ) 35mfc-board wall (3//,5) (Mix ) cavity-wall, non-insulated (gas) 35mfc-board wall (3//,5) (gas) cavity-wall, non-insulated (electricity) 35mfc-board wall (3//,5) (electricity) cavity-wall, non-insulated (Mix ) 35mfc-board wall (3//,5) (Mix ) cavity-wall, non-insulated (gas) 35mfc-board wall (3//,5) (gas) cavity-wall, non-insulated (electricity) 35mfc-board wall (3//,5) (electricity) [MJ / m board] 5 35 3 5 15 1 5,,5,5,75 1, 1,5 1,5, [kg CO-equi. / m board] 5 15 1 5,,5,5,75 Figure : Cumulative energy demand, GWP, and POCP for a non-insulated and an with a 35mfcblown board insulated pitched warm roof or cavity wall with different heating systems during the first two years of use Shown are standard scenarios for different heating systems for sprays without facings. The numbers in parentheses refer in sequence to the specific weight in [kg/m 3 ], to the thermal conductivity in [mw/(m * K)]. The source for the thermal energy is either a representative mix of heating systems in Germany for the year, a gas heating system, or electricity. For key settings see preceding table. 1, 1,5 1,5, [kg ethene-equi. / m board],7,,5,,3,,1,,,5,5,75 1, 1,5 1,5,

page 1 35mfc-blown board shows a higher GWP as compared to the n-pentaneblown board, keeping however its environmental advantages in the other parameters (figure 7). To achieve the insulation performance of the 35mfc-blown boards the thicknesses of the n-pentane-blown boards have to be increased by approx. 1 %. For u-values higher than. W/(m * K) the GWPs for all thermal insulation systems regarded are equally competitive (i.e. differences are below approx. 1 %). Changing heating systems may substantially alter environmental effects for both insulation applications irrespective of the blowing agent used. 35mfc-blown boards keep their advantageous/competitive environmental profile as compared to n-pentane boards. The higher cumulative energy demand as well as the higher contribution to the GWP and POCP of an insulated pitched warm roof or a cavity wall as compared to a non-insulated roof or wall are compensated by the lower transmission losses of the insulated roof or wall within the first year of use irrespective of the heating system (figure ). Conclusions and recommendations environmentally high performing PU-rigid foam insulation products. In a practicable and meaningful range of variations of key parameters 35mfc as a blowing agent offers an opportunity to produce environmentally advantageous or at least competitive PU-rigid foam products for thermal insulation as compared to available environmentally sound alternatives. Environmental advantages of 35mfcblown PU-rigid foams are all the more evident when the applicable thickness of the insulation products is limited (e.g. due to spatial or static restrictions) or their service lives are increased. Apart from aiming at even lower λ-values in the further application development of 35mfc-blown PU-rigid foams, controlling blowing agent losses should be strived for, e.g. by diffusion-resistant facings and by an adequate after-use-management of the products to keep the environmental lead. The full report indicates in detail which properties of 35mfc-blown PU-rigid foam products will result in which overall environmental performance. Thus, the elaborated results can guide further application development, form the basis for product communication, and support considerations regarding marketing activities. The results show that the zero-odp blowing agent 35mfc has the potential to replace 11b to be the standard in