MEDICAL THE SURFACE ENGINEERS

Similar documents
AEROSPACE THE SURFACE ENGINEERS

PRIREV. ZI Vagos, lote

Cutting Tool Materials and Cutting Fluids. Dr. Mohammad Abuhaiba

PVD Coating Solutions Around You

Relation Between Internal Stress and Surface Roughness of Titanium Nitride Films Deposited by HCD Ion Plating

COMPARISON BETWEEN PVD AND CVD+PVD COATED INSERTS FOR CUTTING FORCES AND TOOL WEAR DURING TURNING OF RAMAX-2

INTRODUCTION. Think HSS

NANO SCRATCH TESTING OF THIN FILM ON GLASS SUBSTRATE

Tribology in Industry. PVD-Alumina Coatings on Cemented Carbide Cutting Tools: A Study About the Effect on Friction and Adhesion Mechanism

The most important parameters determining the performance of a cutting blade are:

Stamping Tooling Optimization Coating Fatigue Test

CORUN ELKOTRON ELKOTRON PLASMA VACUUM DEPOSITION PVD TECHNOLOGY

WEAR AND BLANKING PERFORMANCE OF AlCrN PVD-COATED PUNCHES

Study of the Effect of Substrate on 3D Surface Roughness in Diamond-Like-Carbon Coating Process

ÓASM International DOI: /s /$19.00

Status of surface modification techniques for artificial hip implants

Kanigen Group, your partner for electroless nickel plating

DuraCer. Ceramic Components. The Strong Choice In Ceramics

Mold Design. 12. Mold Materials. Bong-Kee Lee School of Mechanical Engineering Chonnam National University

Author: M Shaw, Sika Limited. Construction. A Guide to the Concrete Repair European Standards BS EN 1504 Series

Ultra High Barrier Coatings by PECVD

Discover the variety of Metal Powders

Available online at ScienceDirect. Procedia Engineering 152 (2016 )

Vacuum Furnaces Furnaces for Advanced Materials

Ion implantation the job coater s supplement to coating techniques

Future Developments in High-Performance Plastics

PLASTICIZING SCREWS AND BARRELS. Brixiaplast brand

Friction and Wear Properties of Materials used in Hydrogen Service*

Available online at ScienceDirect. Procedia Engineering 148 (2016 )

LUBRICATION & MACHINING OF COMPACTED GRAPHITE IRON

Tribological dry coatings. Integrated security of installation

Genesis of Friction between Macroscale contacts. Reference: Chapter 3 of the text books

High-Performance Treatments & Coatings

Tribological Property of FG/UHMWPE Composites

1. INTRODUCTION. Further exploitation of the technology led to coatings which offer huge

High-Performance Plastics for. Drivetrain Systems SPECIALTY

WEAR PROPERTIES OF PLASMA NITRIDED INCONEL 718 SUPERALLOY

HIGH PERFORMANCE LINING FOR BULK MATERIAL HOPPER

Fastening technology for metals and plastics

High strain point glass substrate for photovoltaic solar cell

Price and Availability

Full Nanomechanical Characterization of Ultra-Thin Films

APPLICATION METHODS AND PERFORMANCE STUDY OF COATINGS ON TOOLS USED IN DRY MACHINING

2.79J/3.96J/BE.441/HST522J MATERIALS: BONDING AND PROPERTIES. M. Spector, Ph.D.

ArenNano Black Stainless black sol gel on Stainless Steel

MECHANICAL COMPATIBILITY OF TI COATINGS DEPOSITED BY HVOF THERMAL SPRAYING

Micro-Electro-Mechanical Systems (MEMS) Fabrication. Special Process Modules for MEMS. Principle of Sensing and Actuation

Advanced Surface Technology

Ceramics in Orthopaedic and Neurosurgery. B. Sonny Bal, MD MBA JD PhD University of Missouri-Columbia Amedica Corporation

Fatigue behaviour of duplex treated AISI 316L stainless steel

The Performance Advantage. tough coatings perform. Performance Engine Parts

Spiral Point Plug Taps

iglidur A180 FDA-general purpose waterproof material

Epoxy adhesive EN

Pulsed laser deposition of AlMgB14 thin films

CARBONITRIDING & NITROCARBURIZING. Comparative study on tribological behaviours

Atomic Layer Deposition

The Leader in Oilfield Coating Technology ISO 9001:2008.

Lubricating coating prepared by PIIID on a forming tool

Material data sheet. EOS Titanium Ti64. Description

One-part moisture-curing elastic adhesive meeting UL94V-0 flammability standard

Lecture 19 Microfabrication 4/1/03 Prof. Andy Neureuther

Cryogenic Metal Seated Butterfly Valves

EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2012/48

MECHANICAL AND PHYSICAL PROPRIETIES

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

PROPYLUX HS rods are exclusively produced by Westlake Plastics.

LOT. Contents. Introduction to Thin Film Technology. Chair of Surface and Materials Technology

APPLICATION OF CERAMICS TO HIGH PRESSURE FUEL SYSTEMS. Thomas M. Yonushonis Cummins, Inc.

Annealing effects on microstructure and mechanical properties of chromium oxide coatings

A hollow cathode high density plasma process for internally coating cylindrical substrates

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

Tribology behavior of a lubricant with nano-diamond particles on steel

Special Coatings Special Materials

Ion Nitriding of Stainless Steel: III

iglidur J200 For Anodized Aluminium iglidur J200 Phone Fax Very long service life with hard anodized aluminium

ON-GOING STUDIES AT CEA ON CHROMIUM COATED ZIRCONIUM BASED NUCLEAR FUEL CLADDINGS FOR ENHANCED ACCIDENT TOLERANT LWRS FUEL

CVD DIAMOND AND RELATED MATERIALS AT INSTITUTE FOR SPACE RESEARCH AND INDUSTRY: RESEARCH, DEVELOPMENT AND INNOVATION.

Modern Methods of Surface Engineering

Flat-Sheet-Dies up to 9 m width and high-tech Coatings for wear and corrosion protection

Universal resistance to chemicals. High compressive strength. Very low moisture absorption

ATI Datalloy HP TM Alloy

Scotch-Weld Metal Bonder Acrylic Adhesive DP8407NS Gray

Surface Morphology and Characteristics of Electroplated Au/Ni Films for Connector Contact Materials

Surface Protection Systems

Keysight Technologies Laser Heated Tip and High Temperature Stage for G200 Nano Indenter. Data Sheet

MANUFACTURING PROCESSES. Tool Material & Cutting Fluid

Nanoindentation of La-Cr-O Thin Films

ABSTRACT. Annex 4. Table of contents

material specifications

C Si Mn Cr P S N Nb <0.030 <1.0 < to 18 <0.040 <0.030 < xC to 0.6

Effects of TiO2 Contents on HA/TiO2 Composite Coating by Electrophoretic Deposition Lei Zhao, Huiping Shaoa, Hang Zheng

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved.

AM CORRAX. Uddeholm AM Corrax

Coating Thickness Meter Data Sheet / Instructions

RESEARCH AND DEVELOPMENT OF COATINGS FOR ZIRCONIUM FUEL CLADDINGS

ZnO-based Transparent Conductive Oxide Thin Films

ME 383S Bryant February 10, 2005

"ITO Film Trend for Touch Panel Applications"

Transcription:

MEDICAL THE SURFACE ENGINEERS

We are the leader in Medical Coatings, you get the benefits Ionbond Coatings for Medical Implants Ion Concentration (p.p.m.) Co Cr Mo 25 20 15 10 5 0 No coating TiN-TiN* CrN-CrN Corrosion Resistance Femoral head coated with Ionbond Medthin Ultrahigh Molecular Weight Polyethylene Tibial plate coated with Ionbond Medthin Wear (mm 3 ) MOM TiN ontin CrN on CrN 2.5 2.0 1.5 1.0 0.5 0.0 Cycles (x10 6 ) Low wear anti-allergy solutions There are two primary types of artificial joint designs, those that use polyethylene separators and those that employ metal-on-metal designs. In both cases Medthin coatings significantly improve the performance of these systems. Polyethylene-based Designs The established design of articulating systems experiencing heavy loads, as for example in the case of a full knee replacement, is to use a polyethylene separator to avoid metal-on-metal (MOM) contact. Here Ionbond nanoscale coatings are essential in three ways: Prevents corrosion caused by contact with body fluids Minimizes the creation of polyethylene wear debris Reduction of the metallic ion concentration by a factor of 1000 x over uncoated implants Metal-on-Metal Designs In some systems metal-on-metal contact is the preferred solution. These ball-socket type of joints are common in hips, wrists, ankles, and fingers. Ionbond over the last 15 years has developed special coatings for these ball-socket systems. With the loads bearing directly on the metallic joints the wear resistance in such systems is of primary importance. Medthin coatings provide: Reduced wear by a factor of 10 over uncoated joints Low friction coefficients of less than 0.2 Consistently high film cohesion 0.0 0.5 1.0 1.5 2.0 Wear Resistance

State of the art PVD, CVD, and PACVD coatings for Medical applications in the Most Demanding Applications Tribology Ionbond s Tribological PVD/PACVD films Spinal discs can be coated with our industryleading Medthin 43 ADLC (Diamolith) that provides: Rough surface prepared for osseointegration Tribological solutions PVD/PACVD thin films Hydrophobic surfaces Higher contact angle when compared with other thin films such as PVD nitrides High hardness Low friction coefficient Approved for low load applications (< 300 N) Cell attachment Poly-Ether-Ether-Ketone SmArtSpine SAS Poly-Ether-Ether-Ketone (PEEK) substrates coated with thick PVD Medthin 65 Ti for cell attachment (Hydrophilic surfaces low contact angle): Ionbond recently developed a unique industrial scale technique for application of Medthin 65 Ti onto implants made of PEEK and Carbon Fiber re-inforced PEEK. Ionbond «Metal on PEEK» coating has the following properties: Adhesion > 20 MPa. Coating thickness up to 20µm. Coating possible on smooth plastic injected molded surfaces as well as on blasted surfaces Medthin 65 Ti is a coating suitable for cell attachment Cell attachment to Medthin 65 Ti

Ionbond Coatings for Medical Instruments Anti-reflection Ionbond Nanocrystalline anti-reflection coatings for surgical instruments: Nanocrystalline coating structure of Medthin 20 coatings allow long life time through improved corrosion resistance Light reflection reduced by 70 % Deposition temperature below 200 C PVD-process preserves properties of thin instruments tips Ionbond has extended capacity for coating large volumes at our medical device coating locations worldwide. Thread coating Ionbond tailored coatings for screw and spindle systems: Reduction of Friction Reduction of Galling Color-coding Instruments made from stainless steel and CrCoMo can be color coded. Excellent chemical inertness Amorphous or dense nanostructured thin films High resistance to sterilization processes THE SURFACE ENGINEERS

You make it first, we make it last The Medthin Family of Biocompatible Coatings Amorphous C:H Nanocrystalline-AlTiN Columnar w/nanograins Surface morphology 1µm 1µm 1µm 50µm Photo: Cross section micrograph Photo: Cross section micrograph Photo: Cross section micrograph Photo: morphology micrograph Medthin 43 ADLC Medthin 20 AlTiN Medthin 01; 16; 30; 60 TiN, TiAlN, CrN, ZrN, Medthin 65 Ti Hardness [GPa] Adhesion [N]: >50 Friction Coefficient: 0.10 Color: Black Physical properties Hardness [GPa] Elastic modulus [GPa] Adhesion [N]: >70 Friction coefficent: 0.2 after post treatment Color: Dark Gray Adhesion [N]: >60 Thick films are possible Multilayers are possible Adhesion [MPa]: >20 Roughness Ra >1µm Excellent intrinsic roughness for cell attachment Applied on PEEK and CF-PEEK Elastic Modulus [GPa] 50 400 40 350 30 20 10 300 250 200 150 0 100 Wear Rate [mm 3 /(Nm)] 1.2 10 5 1 10 5 8 10 6 6 10 6 4 10 6 2 10 6 1 10 7 Wear rates Post-treated coatings As deposited coatings Adhesion For a complete list of coatings see www.ionbond.com Adhesion [MPa] 25 20 15 10 5

Competence and Innovation Worldwide Ionbond is a global leader in surface enhancement technology with 38 local coating centers and has been dedicated to the medical device industry for more than 20 years. Ionbond has pioneered the commercial application of hard coatings. The Ionbond Medthin line of Medical Grade Coatings meets the strict guidelines and performance requirements of the medical device industry. Quality and consistency are insured through compliance with established industry regulatory requirements that include certified biocompatibility acoording to ISO 10993-1 and compliance with the tenets of ISO 13485. Ionbond employs IQ, OQ, PQ process validated systems and Medthin coatings have US FDA Master Files for Medical Devices (MAF). Key locations for Medical Coatings NORTH AMERICA Ionbond US Rockaway 200 Roundhill Drive US-Rockaway, NJ 07866 USA Phone: +1 973 586 4700 email: infous@ionbond.com EUROPE Ionbond Switzerland Olten Industriestrasse 211 CH-4600 Olten Phone: +41 62 287 86 86 email: infoch@ionbond.com Ionbond France Paris 19, rue Robert-Schuman F-77350 Le Mée-sur-Seine Phone: +33 1 64 83 01 25 email: infofr@ionbond.com Ionbond UK Consett Unit 36 Number One Industrial Estate Medomsley Road Consett, County Durham GB DH8 6TS Phone: +44 1207 500 823 email: infouk@ionbond.com ASIA Ionbond China Wuxi Building 17-B, Land Plot A-52 National High-Tech Industrial Development Zone CN-214028 Wuxi City Jiangsu Province Phone: +86 510 8815 2528 email: infocn@ionbond.com Ionbond Malaysia Kualalumpur No. 5 Block B, Jalan Sungai Kayu Ara 32/39 Taman Berjaya, Seksyen 32 MY-40460 Shah Alam, Selangor Phone: +60 16 661 2727 email: infomy@ionbond.com See our Website for a full list of our coating centers. www.ionbond.com THE SURFACE ENGINEERS 04.2014