Flanged Water Meters (non-continuous flow)

Similar documents
Dorot Irrigation Meter

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

METERING TO DATA MANAGEMENT

Bore 15 and 20 Threaded male BSP 0 C + 30 C Max Pressure : 16 Bars Specifications : Single jet Rotating dial Super dry Magnetic transmission

NOTICE OF DISCONTINUATION,

DIVA flowmeter. for saturated steam flow measurement

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Gilflo flowmeters. for steam, liquids and gases

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

F Series Flow Meter F300. User Manual

SUGGESTED SPECIFICATIONS Pump Frames through 64132

Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Target Inline Flowmeter

In-line Twin Pump. Type Series Booklet. Omega DSL

Process Inline Filter, Change-Over

EC medium pressure axial fans.

METERS AMR/AMI CONTROL. AGRICULTURE P r o d u c t s C a t a l o g. Member of the

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Series description Wilo-Drain STS 40

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

3.1 Rev Features. Horizon. Materials and Specifications. Horizontal Turbine Meters Sizes 1-1/2", 2"

VERIS Accelabar. Superior Flow Measurement Accuracy

Turbine Meter TRZ 03 PRODUCT INFORMATION. Serving the Gas Industry Worldwide

Model EVMS Vertical Multistage Pumps for the Global Market

Monolithic Isolation Fittings

ISO INTERNATIONAL STANDARD

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Forward-looking and energy efficient Biomass heating

AVK (WWE) BUTTERFLY VALVE DN 50 to DN 2000 (2" to 80") 75 (EVFS)

Industrial Flowmeters

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

GD Valves Rubber Lined - Centric EVS. Wouter Witzel - EVS /

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

Regulating valves REG 6-65, REG-SS 15-40

Vortex EX DELTA lowmeter Technical Specifications

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

DCV Wafer check valves

Series Sump and Sewage Systems

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid

Liquid level switch BW 17

TVA Target Variable Area Flowmeter

Flow Meter Calibration

Water Measurement. Presentation by. L. Niel Allen Extension Irrigation Specialist Utah State University

Flygt 3171, 50Hz. Technical Specification

FPI Mag Flow Meter. Next Generation Mag Meter: Solving WTP s Tight Installation Dilemma. McCrometer, Inc. (800)

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

SECTION PACKAGE BOOSTER PUMP STATIONS

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

SECTION ALUMINUM GATES

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3)

N-pump, Standard Motor

Datasheet RS Pro RS Series Axial Carbon Resistor 1kΩ ±5% 2W ppm/ C RS Stock No:

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Diaphragm seal with flange connection With internal diaphragm Model

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

UDZVFH18B Zener Diode (AEC-Q101 qualified) Outline

Operating instructions - Translation of the original -

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Tuchenhagen. Product Recovery Systems

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice

Heat measuring and heat cost allocation. HVAC Products

SECTION SLUDGE HOLDING TANK DECANTER PUMP

Magnetic float switch For vertical installation Model FLS for nuclear power plants

AS/NZS 2280:2012 AS/NZS

Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE

ECLIPSE. NSF/ANSI 61* *Non-metallic Only EXTERNAL GEAR PUMP ENGINEERED PRODUCTS. Flow: up to 33 gpm (125 lpm)

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. : +200 C OScrew O thread: G ¼... G 4. t max. Rp 1...

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

J.I.C. HYDRAULIC TUBING Seamless & Welded Hydraulic Fluid Line 23 Seamless Burst Pressures & Working Pressures 24 Welded Burst Pressures 25

Close Coupled Sump Pumps Type ETLB

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86

UNIVERSAL SEAL SERIES

GOULDS PUMPS. Commercial Water. e-sv General Market Specifications. Applications. Specifications

tandard International Shipbuilding - Bilge mud boxes for machinery spaces and tunnels - General design characteristics First edition

Figure 3. 1 Nutating Disc with R-10 register

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1

SIWAREX FTC-B Weighing Module for Belt Scales Set-up of SIWAREX FTC with SIWATOOL FTC_B

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Electromagnetic flowmeter ProcessMaster FEP300/500 The first choice for the process industry

Mechatronic pressure measurement. Applications. Special features. Description

Pressure transducers DMU 02 Vario (flush)

SECTION TAPPING SLEEVES AND VALVES

Selecting the correct device for measurement control

Dŵr Cymru Welsh Water s Self-lay Policy for Water Mains and Services July 2015

Swirl flowmeter FS4000 Compact, reliable and robust

FLOWRATE MEASURE PROBE DEBIX

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Transcription:

Flanged Water Meters (non-continuous flow) Features MW-F Suitable for use with domestic water Pulsed output Low head loss Specification Product Codes Meter: Cold water: Fluid temp. range: Cold 0 to 30 C (safety margin 50 C) Hot 0 to 90 C (safety margin 120 C) Body material GG25 Grey cast iron, epoxy coated Flanges DIN2501 PN1 Counter 7-Roller type Max. working pressure 1bar Installation position Meter horizontal / dial upwards (preferred) or vertically MW-CF-50-B MW-CF-5-B MW-CF-80-B MW-CF-80-C MW-CF-100-B MW-CF-100-C MW-CF-125-C MW-CF-150-C MW-CF-200-C 50mm Flanged meter 100LPP 5mm Flanged meter 100LPP 80mm Flanged meter 100LPP 80mm Flanged meter 1000LPP 100mm Flanged meter 100LPP 100mm Flanged meter 1000LPP 125mm Flanged meter 1000LPP 150mm Flanged meter 1000LPP 200mm Flanged meter 1000LPP Pulsed output specification: Hot water: Switch type Reed switch proximity sensor Contracts Volt free Pulse value (per litre) 1, 10 or 100 Max. load current 500mA Max. switching voltage 180Vdc Max. contact rating 10W Connection type Flying lead Lead length 2 Meters MW-HF-50-B MW-HF-5-B MW-HF-80-B MW-HF-80-C MW-HF-100-B MW-HF-100-C MW-HF-125-C MW-HF-150-C MW-HF-200-C 50mm Flanged meter 100LPP 5mm Flanged meter 100LPP 80mm Flanged meter 100LPP 80mm Flanged meter 1000LPP 100mm Flanged meter 100LPP 100mm Flanged meter 1000LPP 125mm Flanged meter 1000LPP 150mm Flanged meter 1000LPP 200mm Flanged meter 1000LPP Page 1 of 5

An Introduction to Flow Parts for Metering Sontay offer flow parts for two distinct applications. Flow parts for water Denoted as water meters - are used specifically for sanitary water only, i.e. water without additives or chemical treatment, and are designed for non-continuous flow, such as domestic cold and hot water supplies. The total daily flow should not exceed 3 hours, over a year period. Volumetric flows higher than this can lead to increased wear in the bearings of the impellor, causing inaccuracies in reading. Note also that water meters have a narrow fluid temperature range, typically between 0 C to +90 C for hot water meters and 0 C to +30 C for cold water meters. Flow parts for heating Denoted as flow sensors - can be used with chemically treated water, and are designed for continuous or very high duty cycle flow conditions typically found in hot water heating systems. Flow sensors have a wider fluid temperature range than water meters, typically between 0 C to +120 C. Note: Because of these distinct differences, only flow parts designed specifically for heat metering should be used for heat metering applications. Although water meters can, in theory, be used for heat meter applications, Sontay cannot warranty water meters if used in this manner. Definitions Qs, the upper limit of the flow-rate, is the highest flow-rate at which the heat meter shall function for short periods (< 1h / day; < 200 h / year), without the maximum permissible errors being exceeded. Qp, the permanent flow-rate, is the highest flow-rate at which the heat meter shall function continuously without the maximum permissible errors being exceeded. Qi, the lower limit of the flow-rate, is the lowest flow-rate above which the heat meter shall function without the maximum permissible errors being exceeded. Page 2 of 5

Technical Overview The MW-F range of flanged meters incorporate unique paddle wheels which enable the meters to cover a very large measuring range with low head loss. The impellers that are mounted perpendicular to the flow. The impeller rotation speed increases with the water flow rate. The meters use a magnetic transmission system between the impeller and the totalising register to minimise drag and to enable the register to be total sealed from the water supply. All meters are fitted with a pulsed output reed switch. Installation & Location Flanged meters can be installed horizontally and vertically, that is, in horizontal, vertical, and inclined pipelines. The best measuring results can be obtained if the meter is installed in horizontal position with the counter facing upwards. Water meters should always be fitted with a minimum of 3x pipe diameter upstream. For example, a 5mm water meter would have 195mm before the meter as straight pipe. This is to ensure accurate reading by reducing water turbulence. Ideally a straight pipe section of at least 2 x DN is required down stream. 3 x DN MW-F It is recommended as good practice to fit a removable filter element (strainer) before a water meter to protect the mechanism. Only clean water should be used that does not exceed the temperature specification of the meter. This is 30 C for cold meters and 90 C for hot meters. Page 3 of 5

Typical Error Curve Error in % 5 4 3 2 1 0-1 -2-3 -4-5 - 1 10 100 Flow rate % of Qn Head Loss Table Pressure loss (bar) 1.0 0.1 1 2 3 4 5 7 0.01 0.001 1 10 100 1000 10000 1 2 3 4 5 7 DN50 DN5 DN80 DN100 DN125 DN150 DN200 Flow rate (m³/h) Page 4 of 5

Performance Data MW-xF-50 MW-xF-5 MW-xF-80 MW-xF-100 MW-xF-125MW-CF-150 MW-CF-200 Upper Limit (m³/h) 90 120 150 250 300 350 50 Permanent (m³/h) 15 25 40 0 100 150 250 Lower limit (m³/h) 0.35 0.45 0.8 1.5 3 3.5.5 Terms Of Reference Upper limit (maximum) flow-rate - Q s The highest flow-rate at which the water meter is required to operate in a satisfactory manner for a short period of time without deterioration. Permanent (Nominal) flow-rate Qp Flow-rate at which the water meter is required to operate under normal conditions of use, e.g. under steady and/or intermittent flow conditions. Lower limit (minimum) flow-rate Qi The lowest flow-rate at which the water meter is required for the meter to function Dimensions DN H L MW-xF-50 MW-xF-5 MW-xF-80 MW-xF-100 MW-xF-125 MW-xF-150 MW-xF-200 DN 50 5 80 100 125 150 200 L 200 200 225 250 250 300 350 H 200 208 255 275 290 305 375 Flange dia. 15 185 200 220 250 285 340 Bolt circle dia. 125 145 10 180 210 240 295 Number of bolts 4 4 8 8 8 8 12 Weight (kg) 11.2 13.2 1.7 19.3 23.2 32 47 All measurements mm unless otherwise stated. Page 5 of 5 For the latest information and product updates, register at www.sontay.com Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense resulting from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.