January 14, 2006 Structural Thesis Proposal: Structural and Breadth Redesign Options

Similar documents
Table of Contents.2. Introduction...3 Gravity Loading and Deflections..4. Existing Structural System..8

FDA CDRH Laboratory Silver Spring, Maryland. Executive Summary: Timothy Mueller Structural Option Walter Schneider

ECMC Skilled Nursing Facility Architectural Engineering Senior Thesis AE 481W Thesis Proposal Dr. Ali Memari January 13 th, 2012

Brent Ellmann Structural Option 200 Minuteman Park, Andover, MA Structural Consultant: Dr. Hanagan

Proposal. PricewaterhouseCoopers Oslo, Norway

Hilton Baltimore Convention Center Hotel Western Podium

Johns Hopkins Graduate Student Housing. Thesis Proposal. 929 North Wolfe Street Baltimore, Maryland Brad Oliver Structural Advisor: Professor Memari

Structural Comparison between Pan Joist Concrete and Steel Frame Systems for UMCP Student Housing Building B

151 First Side. Technical Assignment 2 November 16 th, William J. Buchko. AE 481w Senior Thesis The Pennsylvania State University

MITRE 3 Building McLean VA

Structural Redesign Gravity System

Global Village Rochester Institute of Technology Rochester, New York

Structural Technical Report 1 Structural Concepts / Structural Existing Conditions Report

Structural Technical Report #2 Pro/Con Study of Alternate Floor Systems

Structural System. Design Criteria Fire Resistance Concrete designed for 2 HR rating (worst case) Geotechnical Report Allowable Bearing Capacity

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

PricewaterhouseCoopers Building Oslo, Norway

Technical Report 3. Alyssa Stangl Structural Option Advisor Dr. Linda Hanagan L A J O L L A C O M M O N S P H A S E I I O F F I C E T O W E R

Structural Technical Report #2 By Robert Whitaker

MEMORIAL SLOAN-KETTERING CANCER CENTER

Thesis Proposal. Nasser Marafi. Center & Facility Service Building. St. Joseph Hospital of Orange Patient Care. Proposal

Thin Slab Floor Systems for High Rise Towers. By Steven M. Baldridge, P.E., S.E., and Jeffrey Yoders

Totaling approximately 617,000

one structural behavior, systems and design Course Description Course Description Syllabus & Student Understandings statics mechanics of materials

Technical Assignment 1 10/8/03

North Mountain IMS Medical Office Building

AISC Steel & Timber Research for High-Rise Residential Buildings

THE PLAZA AT PPL CENTER ALLENTOWN, PA

HOTEL NORTHEAST U.S. JORDAN RUTHERFORD STRUCTURAL OPTION FACULTY ADVISOR DR. THOMAS BOOTHBY AE SENIOR THESIS APRIL 8, 2013

The designer shall also submit additional information required by the University as described and underlined below.

One and Two Family Additions

Corporate Headquarters

Spring Hill Suites Marriott

EXTREME. Makeover. Nu Skin Enterprises Utah campus gets a fresh new look.

TECHNICAL REPORT 2 BUILDING CODES, SPECIFICATIONS, AND LOADS

Marina Bay Sands Hotel Arch 631 Kayla Brittany Maria Michelle

Angela Mincemoyer Structural Option Advisor: Dr. Boothby Peggy Ryan Wil iams Center Ithaca, New York 3 March 2014 Peggy Ryan Williams Center Proposal

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

111 MORGAN ST. CHICAGO, IL

Building Systems and Design Elements included in SliDeRulE

John Hopkins Graduate Student Housing. Technical Report North Wolfe Street Baltimore, Maryland Brad Oliver Structural Advisor: Professor Memari

R CODE CHANGE PROPOSAL FORM (See instructions on page 2)

LIFE SCIENCES BUILDING STRUCTURAL CONCEPTS AND EXISTING CONDITIONS

North Mountain IMS Medical Office Building

Structural Option April 7 th, 2010

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

William W. Wilkins Professional Building

CE 3150 Reinforced Concrete Design Design Project

Project Address: Name of Person Completing Form:

Massachusetts General Hospital - Building for the Third Century Lateral System Analysis and Confirmation Design

Administrative Changes

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

CVEN 483. Structural System Overview

Nasser Marafi. Alternate Floor Systems. Pro Con Structural Study of. Technical Report 2. Center & Facility Service Building

Comparative Study of R.C.C and Steel Concrete Composite Structures

Chapter 2 EARTHQUAKE-RESISTANCE REQUIREMENTS

SECTION PLATE CONNECTED WOOD TRUSSES

Structural Inspection

Concrete Framing systems. Design choices. Basic flavors

A-One Polar Ltd. Bhulta,Rupgonj,Narayangonj. ( , ) 27th April 2014

Executive Summary Thesis Proposal

Thesis Cira Centre Philadelphia. Structural Redesign of Lateral Force Resisting System. Andrew Kauffman Structural Option

Structural Technical Report #1 By Robert Whitaker

Tech Tips SidePlate Connections FAQ 09/30/2017

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Copyright. magazine. CFS Load Bearing Construction

Carpenter Level 2 Rev. September 2017

SJI Updates Expanded Load Tables for Noncomposite Joists / Joist Girders and Development of New Composite Joist Series

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

Kiski Area High School Allegheny Township, PA FLOOR SYSTEM ANALYSIS

ctbuh.org/papers The Bow: Unique Diagrid Structural System for a Sustainable Tall Building Title:

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING

Michael Bologna. 665 Meadow Ln Rochester PA, State College, PA October 16, 2015

CH. 9 WOOD CONSTRUCTION

R Code and Commentary for 2012 NC Residential Code final 03/06/13

ArcelorMittal Europe - Long Products Sections and Merchant Bars. Office Building ArcelorMittal in Esch Alzette

CHAPTER 2: CONCRETE POST-TENSIONED REDESIGN

RESIDENTIAL BUILDING PLAN REQUIREMENTS

SEISMIC ANALYSIS OF SIX STOREYED RC FRAMED BUILDING WITH BRACING SYSTEMS

2003 International Residential Building Code

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

NATIONAL HARBOR BUILDING M OXON HILL, MARYLAND. Ryan Sarazen Structural Option Technical Report 3 Faculty Consultant: Dr.

Council on Tall Buildings

Structural Requirements

Shear Wall Analysis. Introduction. The Medical Office Building Malvern, PA 7

Effect of Edge Beam and Shear Wall on the Structural Behavior of Flat Plate Multistoried Building: A Computing Modeling for lateral load Analysis

CE 549 Building Design Project Spring Semester 2010

Site Analysis. Site Conditions: Seismic Challenges Strong Winds Average Temperature 69. San Francisco

LVL Product Guide 2.0E LVL 1.5E LVL

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

INFORMATIONAL PACKAGE ACCESSORY RESIDENTIAL BUILDINGS (INCLUDING DETACHED GARAGES, STORAGE BUILDINGS & WORKSHOPS)

MANHATTAN COLLEGE STUDENT COMMONS

Eric Alwine Structural Option George Read Hall The University of Delaware Dr. Boothby Technical Assignment #2 October 31, 2005 EXECUTIVE SUMMARY:

Distribution of Forces in Lateral Load Resisting Systems

CE 549 Building Design Project Spring Semester 2013

Architecture as ART BY SHINJINEE PATHAK, PE, AND VICTORIA G. PONCE DE LEON, PE

xiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of

Introduction Proposed Renderings. Concept Report. March 1,

Transcription:

River Tower at Christina Landing Wilmington, DE Joseph Bednarz Structural Option Faculty Advisor: Dr. Boothby Executive Summary January 14, 2006 Structural Thesis Proposal: Structural and Breadth Redesign Options The River Tower is part of the latest phase of redevelopment along the banks of the Christina River in Wilmington, DE. The redevelopment site consists of luxury townhouses, a 22-story apartment building, and will now add the River Tower, a 25-story condominium tower. The River Tower s structural system includes a slab-on-grade structural slab and 8 posttensioned floor slabs with reinforced concrete columns for gravity load support. The primary lateral system for the tower consists of reinforced concrete shear walls, but the concrete columns also provide lateral resistance. Previous technical assignments have presented preliminary analysis on the existing posttensioned slab system and the existing lateral system of reinforced concrete shear walls. Alternate floor systems were also considered, with composite steel framing and hollow core slab planks yielding the most promising results. When compared to the existing system, these alternates would add to the floor-to-floor height by several inches per floor. This would ordinarily be a deciding factor, had the River Tower design team not already received code variance for its building height from the city of Wilmington, DE. The composite steel framing system will be further studied despite its increase in assembly cost and floor thickness from the existing conditions. The composite steel framing system would significantly provide a lighter overall building weight and simplify the lateral resistance system. This could potentially open up the current column and architectural layout. Both braced and moment frames will be considered initially, with research and preliminary RAM output becoming deciding factors. With such a significant change in building material, a complete analysis of the construction management aspects of budget, scheduling, and erection will be considered as a secondary breadth assignment. Finally, with this redesign of steel and the potential change of layout of the interior spaces, the current mechanical system will be analyzed and redesigned accordingly. The fire resistance system will be another key factor in this new analysis, as the new steel framing will also require fire-proofing of some kind. This report finally lists the procedures involved to accomplish these design goals, and provides a tentative timetable for their completion.

Introduction to the River Tower at Christina Landing The River Tower is part of the latest phase of redevelopment along the banks of the Christina River in Wilmington, DE. The redevelopment site consists of luxury townhouses, a 22-story apartment building, and will now add the River Tower, a 25-story condominium tower. This tower has since been redesigned for value engineering, and has added two stories to create a 27-story condominium tower. The original 25-story design has been the focus of the preliminary analysis of the first semester assignments. The first floor of the River Tower contains retail space and various management and mechanical rooms on the south side of the building, with the entrance to the parking garage on the northern side of the floor. The second through seventh floors of the River Tower are comprised of a parking garage on the north side and six units on the southern side. The additional spaces required by the parking garage result in a wider base to the building, as the lowest eight floors have a wider footprint than the remaining seventeen floors. The eighth floor consists of a Great Room, Fitness Center, six luxury units, along with an outdoor terrace containing a rooftop pool, spa, garden, and observation deck. The other floors contain eight units a piece, each with master bedrooms and baths. These luxury units range in size from oneand two-bedroom dwellings, each unit having access to its own terrace. The largest units contain dens and multiple terraces. Brick-faced pre-cast panels line most of the exterior walls. The entrances on the eastern and southern side of the high-rise incorporate an aluminum glass curtain wall system. The main entrance on the southern side has a canopy with aluminum composite panel system cladding. On the ground floor, a concrete block recessed wall painted black dominates the western elevation, partially obscured by a green-screen fence. An 8 composite aluminum panel reveal lines the building at its uppermost floors. An aluminum storefront glass system is used on the stair towers. Sliding doors open from the units to individual terraces (some penthouses have even two terraces), which are lined with an aluminum perforated railing systems, consistent with the open spaces of the parking garage. Horizontal and vertical metal panel systems hide the rooftop mechanical systems. The rooftop terrace which houses the pool and observation deck is lined with 6 square wood columns with vertical wood infill panels. An expansion joint exists where the edge of the parking garage roof/terrace meets the narrower part of the high rise beginning at the eighth level. The roofing system will be an adhered membrane/roofing flashing system coated with a water proofing sealer. 1

Floor/ Level Residential Spaces Parking Garage/ Other Use Total Floor SF SF % of SF SF % of SF (*: Estimated) 1 11105 37.71 18344 62.29 29449 2 9812 33.08 19851 66.92 29663 3 to 6 9812 32.19 20674 67.81 30486 7 9812 24.80 29748 75.20 39560 8 19851 62.80 11759 37.20 31610 9 to 22 12186 100.00 0 0.00 12186 23 5724 61.50 3583 38.50 9307 24 to 25 0 0.00 1070 100.00 1070* Roof 0 0.00 12186 100.00 12186* West and South Elevations of the River Tower at Christina Landing Provided by O Donnell & Naccarato, Inc., Structural Engineers 2

Structural System Summary Condominium Building Structural System The condominium building will be supported by a deep foundation system that will support the columns, walls, and slabs. The piles will be HP12 84 steel piles driven to 225 tons with a net bearing capacity of 200 tons. These piles will be grouped at columns and transfer load from columns using pile caps. A typical interior pile cap will be 7-9 11-0 and 38 inches thick, with reinforcement in both directions. An exterior pile cap will be 7-9 7-9 with 4 piles and a depth of 32 inches. Concrete grade beams will span from column pile cap to pile cap and support the exterior walls of the building. The first floor structural slab will be a 12 inch thick concrete slab with #7 reinforcement at 12 inches on-center each way, top and bottom. The condominium building floors will have 8 inch thick post-tensioned concrete slabs. The slabs will span between columns spaced at 28-6 in one direction and 23-0 in the other direction. A typical interior column will be 16 52, and its reinforcement and concrete strength will decrease at upper floors. The typical exterior columns are 16 36. Concrete shear walls (varying 12-16 in., depending on location) provide lateral resistance and are located generally around elevators and stair towers and are scattered throughout the plan. The mechanical penthouse roof will be framed by steel beams spaced at six feet on-center with 1 ½ deep, 22 gage roof deck spanning in between these beams. The mechanical area will be enclosed by metal panels with steel stud support. The cooling tower will similarly be enclosed with metal paneling, with a structural channel girt support system. Parking Garage Structural System For the parking garage, additional steel piles (80 ton HP12 53) will be added at approximately 20 feet on-center to support the lowest level slab. The exterior columns will have 9-0 9-0 3-0 deep pile caps with (5) HP 12 84 piles. The interior walls will have a 6-0 wide grade beam with HP12 84 piles on each side of the wall, spaced 8-0 on-center. The slab spanning these piles and columns will be the same as the apartment building slab. The floor framing of the parking garage will be 34 inch deep pre-topped tees which span between 45 to 60 feet. An L shaped beam will comprise the exterior of the building and support the pre-cast tees. These L beams will span approximately 48 feet from column to column. The interior support, including the support of the sloping tees, will be supported by 12 inch thick pre-cast light wall. The exterior pre-cast columns will be approximately 24 36. 12- inch thick shear walls located throughout the plan but concentrated at the stair and elevator cores will resist the lateral loads on the parking garage. 3

Simplified Building Schematic for Typical Floor (Levels 9 through 22): Key: - Tower Columns - Tower Shear Walls - Parking Garage Columns - Parking Garage Shear Walls Solid Lines: Tower Perimeter (whole building) Dashed Line: Parking Garage Levels (Foundation Level to Eighth Floor) Typical Floor of River Tower Condominium Tower Provided by O Donnell & Naccarato, Inc., Structural Engineers 4

Problem Statement The River Tower s current structural system of post-tensioned concrete slabs provides minimal floor-to-floor heights, minimizing the overall height of the building. This is crucial to reduce the overturning moment on the structure. Resistance to overturning is also aided by the overall building weight provided by the concrete slabs, columns, and shear walls. In Technical Report 2, an analysis of alternate floor systems for the River Tower confirmed the adequacy of the current post-tensioned concrete floor slab system. This system provides an efficient balance of minimal floor-to-floor height, system dead weight, and assembly installation cost. A significant reduction of system weight can be achieved using a composite steel framing system. However, this system would add to the floor-to-floor height and assembly system cost. For the educational purposes of this assignment, composite steel framing will be considered as a possible redesign for the River Tower. A composite structural system could present some interesting opportunities for more architectural flexibility. In Technical Report 2, the existing column layout was kept for comparative purposes. During the redesign process, the spans between these columns can be adjusted and perhaps lengthened to open the typical floor plan. Both moment frames and braced frames will be considered in this redesign for the unique benefits for which they provide. Moment frames would allow for unobstructed paneling, an architectural benefit. However, this system resists lateral loading through bending, a very inefficient method that would result in relatively larger column sizes. Moment framing would also require many difficult and complicated connections to ensure this lateral resistance. Braced frames, in contrast, would provide stiffer resistance against lateral loads through axial loading through its braced members. A staggered truss lateral system could be used where architects already have shared party walls between condominium units, and in the process, minimize the use of columns per floor. This could open up the architectural floor plans considerably and allow for more flexible and unique condominium unit features. Overturning capacity of this lighter proposed structure will still be counteracted by the concrete systems of the parking garage located at the lower eight levels of the River Tower. The parking garage areas will not be considered in the scope of this redesign project. Problem Solution This steel redesign will be based on the LRFD method of design. In order to properly and quickly verify the efficiency and suitability of the two aforementioned systems, RAM computer software will be used to size initial members and spans. Gravity and lateral loads will be computed based upon the original building code used in the actual design, BOCA 1996. As a starting point, the original typical bay sizes will be analyzed using RAM, and will altered to the proposed specifications for comparative purposes. Hand calculations for the gravity and lateral loading (both wind and seismic) from previous assignments will be used to verify the RAM outputs. Hand checks for member sizes will also ensure the correctness of the computer software 5

tools. The significant height and unique footprint of the River Tower necessitate use of computer software for analysis. The relative ease of performing multiple iterations with RAM or similar structural analysis software will help present the most efficient solution. RAM software will also allow for a three-dimensional analysis of the lateral loading, which can account for the irregularity of the River Tower footprint. Breadth Studies With a new material and construction method to consider with the proposed structural redesign, constructability must be accounted in a comprehensive building analysis. R.S. Means data was used in Technical Report 2 to assess the potential assembly cost for choosing a composite steel framing system. This research will be expanded upon, with a consideration for the new scheduling and equipment requirements based on a now mostly steel structure. The feasibility for construction of this new system will play a major role in determining its efficiency and suitability for the River Tower. Likewise, the change from two-way concrete slabs to a composite floor system would require adjustments to the mechanical system. The finished ceiling that will hide the new steel floor framing system could be employed to house ductwork and other mechanical equipment. As the floor-to-floor heights and condominium unit layouts are adjusted to the new framing system, the service requirements for the mechanical system may necessitate a resizing or redesign. The switch to a mostly steel building will require a fresh analysis of the fire resistance in the structure as well, as the inherent fire proofing of a primarily concrete structure would be lost. Tasks and Tools The initial stage of redesign will involve the verification of the lateral loading calculations used in previous technical reports, based on the regulations of the BOCA 1996 building code. Research into various forms of lateral resistance in steel framing, especially the possibility of a staggered truss system, will begin as well. The next step will involve the construction of a two-dimensional model for the River Tower using RAM software or a similar structural analysis program. Initially, the original column layout and gravity load estimates from the post-tensioned flat plate system will be used. Once a proper model has been completed, this layout will be adjusted and compared to the variety of alternate systems found by research. When potential systems are identified through these repetitions of structural analysis, cost data and constructability factors will verify a feasible structural system. With this system finalized, typical connections will be detailed and factored into an ultimate design decision. Finally, after confirmation of the details of this new structural framing system, the current mechanical and fire resistance systems will be analyzed and redesigned accordingly. A tentative schedule of these tasks follows and will be adjusted accordingly as the semester progresses. 6

Tentative Timetable for the Spring Semester Week of 8 15 22 29 JANUARY Tasks Verify lateral loading calculations from BOCA 1996 Begin creation of 2-D model of existing conditions using RAM software Research new lateral system and connection alternatives Complete 2-D modeling of structure FEBRUARY Begin alterations and comparison between different column layouts and span dimensions, braced frame versus moment connections, etc. 5 12 19 Breadth Analysis: Cost analysis and constructability 26 Finalize structural system based on cost analysis and structural performance criteria MARCH 5 -- SPRING BREAK -- 12 Breadth Analysis: Examine the suitability of existing mechanical and 19 fire protection system and redesign accordingly 26 Review and organize material for report and presentation APRIL 2 Final Report due on April 5, 2006 Finish PowerPoint presentation and begin rehearsal 9 First Round of Presentations Presentation date on 4/12/06 16 Adjust and revise presentation 28 Jury Presentation 7