ActionCush II Floating Resilient Floor System

Similar documents
CHAMPAIGN CENTRAL HIGH SCHOOL COMBES GYM FLOOR REPAIR. A. Submittals: Product Data, Specification Sheets, Samples and Manufacturer Warranty.

SECTION WOOD GYMNASIUM FLOORING

CONNOR PERMAFLEX & PERMAFLEX II Page 1 of 5

HARO SPORTS FLOOR C.S.I. GUIDE SPECIFICATION Helsinki-Gymnasium Floor System 10/2010 SECTION WOOD ATHLETIC FLOORING

Action ReFlex Spin Resilient Floor System

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING

SECTION WOOD AND ATHLETIC FLOORING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

INSTRUCTIONS FOR EDITING AND COORDINATION SECTION WOOD FLOORING - ATHLETIC

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

CONNOR Control XT Page 1

1. CONCRETE SUBFLOORS.SECTION a. Slab Depression: Equal to thickness of selected flooring (6, 8,10,12,13 or 14mm).

Page 1 of 5 PART 1 GENERAL

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

GUIDE SPECIFICATION

SECTION RESILIENT SHEET FLOORING

GUIDE SPECIFICATION

1. Division 09 Section "Rough Carpentry."

RESILIENT FLOORING: Hot and Heavy - Secoya

RESILIENT FLOORING: Select Step Wood

LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR LOCKING FLOORING

ENGINEERED WATERPROOF FLOORING GENERAL INSTALLATION INSTRUCTIONS FOR VÄLINGE 2G LOCKING FLOORING

ENGINEERED LUXURY VINYL GENERAL INSTALLATION INSTRUCTIONS FOR ANGLE-TO-ANGLE FLOORING

COMPOSITE (WPC) ENGINEERED VINYL FLOORING INSTALLATION

Section II Subfloor Guidelines & Specifications Page Chapter 4 Wood Subfloor Guidelines 23 Chapter 5 Concrete Subfloor Guidelines 26 Chapter 6

WATER TUFF VINYL FLOORING ATTENTION! READ BEFORE INSTALLING! Angle-Tap Installation Instructions

SECTION PREFINISHED FSC MAPLE FLOORING. This is a template: edit this specification carefully to suit specific project requirements.

Signature Sports Flooring Installation Instructions. For SignaDeck Premium Rubber Tiles

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

INSTALLATION INSTRUCTIONS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Bldg. 751 GOETTGE MEMORIAL FIELD HOUSE REFINISH GYM USMC CAMP LEJEUNE MAXIMO: FLOORING A-1 LOCATION & GENERAL DISCRITION

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION ATHLETIC AND RECREATIONAL SURFACING. A. ASTM C 67 - Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile.

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

ATTENTION! READ BEFORE INSTALLING!

WOOD FLOORING WOOD FLOORING

Engine Bay Floors Floor Resurfacing 4000

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

FLUID APPLIED WATERPROOFING

FlexLok Adhesive Tabs for Carpet Tile

Floor Insulation Underlayment Section Sound Control Matting

ATTENTION! READ BEFORE INSTALLING!

ENKASONIC FLOOR UNDERLAYMENT 9110

TILE TILE

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

SECTION PREFINISHED ENGINEERED WIDE-PLANK FSC OAK FLOORING

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

SECTION EXPANSION CONTROL

INSTALLATION GUIDELINES Signature Naturals PureForm Solid Strip Bamboo Flooring

HYDROGRID SUBSURFACE IRRIGATED HARTRU TENNIS COURTS

UNDERLAYMENT INSTALLATION INSTRUCTIONS

9.5, 10, 10.5 & 12mm. Product Use & Installation Options. Engineered hardwood flooring INSTALLATION INSTRUCTIONS

NatureWood Construction Product Specification Guide

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

USA USA USA PURE CLICK

Installation Guide LVP Glue Down

Scuba Seal Installation / Floor Care Instructions With Video Link

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

J.J. Haines & Co., Inc.

Bid: Seventy-First High School Gym Floor Refinishing

Kolorines Glass Mosaic Tiles Project Specification

SELECT SURFACES LAMINATE FLOORING INSTALLATION GUIDE DRIFTWOOD

Regupol Aktiv RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER

Ecore Athletic Elevate BOUNCE 2 GUIDE SPECIFICATIONS Ecore

PROJECT LOCATION. SECTION RECYCLED WOOD FLOORING Rev. 11/13/2012


ACOUSTICAL WALL TREATMENT SECTION 09840

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

HAND-SCRAPED FLOORING INSTALLATION INSTRUCTIONS

Installation Guidelines for EcoDomo Echelon Collection RECYCLED LEATHER TILES AND SHEETS GLUE-DOWN METHOD WITH WATER BASED CONTACT CEMENT

HARD COURT/RUNNING TRACK CONSTRUCTION. A. Section Includes: Tennis courts, basketball/volleyball courts, and running tracks.

INSTALLATION GUIDELINES PREFINISHED SOLID & ENGINEERED WOOD

When I started tiling, we didn t do our own shower pans that BATHS

Narrow Modular Pavers (NMP) for Sand-Set Installations

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SUBFLOOR AND INSTALLATION PREPARATION INSTRUCTIONS

SOUND-TEC ENGINEERED LVT

SECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS

SECTION EPOXY TERRAZZO

ECOfusion Flooring Installation Guide 1/2 & 9/16 Prefinished Solid Strandwoven Bamboo Flooring

Section Fluid Applied Waterproofing

ANTIQUED SOLID / SOLID HARDWOOD

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

General Commercial Installation Guide LAMINATE

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

INSTALLATION INSTRUCTIONS

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

BLUE FOREST Flooring Installation Instructions

ITEM 458 WATERPROOFING FOR STRUCTURES

Click Refresh with In*Step Locking System

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

MILLTOWN. Product Use & Installation Options. 12mm engineered hardwood flooring INSTALLATION INSTRUCTIONS

SPECIFICATIONS: Architectural Aluminum Railings

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

Transcription:

Floating Resilient Floor System SPORTS FLOOR SPECIFICATIONS Action Floor Systems, LLC 4781 N. US Hwy 51 Mercer, WI 54547 toll free: 800-746-3512 voice: 715-476-3512 fax: 715-476-3585 email: info@actionfloors.com web: actionfloors.com

Section 09 64 00 Floating Resilient Floor System Wood Athletic Flooring Contact ACTION FLOOR SYSTEMS, LLC. at www.actionfloors.com or (800)746-3512 for specific project conditions or modifications of this specification. PART 1 GENERAL 1.01 DESCRIPTION A. Related Sections: Cast-in-Place Concrete 1. The general contractor shall provide a level slab, steel troweled to a tolerance of 1/8" (3mm) in a 10'0" (3m) radius and subject to the approval of the wood floor contractor. High spots shall be ground down and low spots shall be filled with an approved leveling compound by the general contractor to the tolerance specified above. 2. MFMA does not acknowledge the use of FF/FL numbers to measure levelness/flatness tolerances in gymnasium concrete slabs. 3. Concrete shall not use river gravel or pea gravel and have an average of 3500 psi. compressive strength after 28 days. Concrete must be cured for 60 days before installation can begin. 4. The concrete slab shall be depressed: 2-5/8 (68mm) for 25/32 (20mm) flooring. B. Related Sections: Membrane Waterproofing 1. Concrete slabs on or below grade shall be adequately waterproofed beneath the slab and at the perimeter walls and on earth side of below grade walls by general contractor using suitable type membrane. C. Related Sections: Thresholds D. Related Sections: Game Standard Inserts 1.02 REFERENCES A. MFMA Maple Flooring Manufactures Association B. MFMA PUR MFMA Performance Uniformity Rating C. DIN 18032-2 - Performance Standard D. ASTM F2772 - Athletic Performance of Indoor Sport Systems E. EN 14904 European Committee of Standardization for Indoor Sports Surfaces F. FIBA International Basketball Federation G. FSC Forest Stewardship Council H. FloorScore Certified product by CDPH 01350 1.03 QUALITY ASSURANCE A. Manufacturer Qualifications 1. Basis of design shall be ActionCush II as provided by Action Floor Systems, LLC. All system component parts must be supplied by Action Floor Systems, LLC. 2. Manufacturer shall be a MFMA Mill Member in good standing, an established firm experienced in the field, and have been in business a minimum of ten (10) years; Action Floor Systems, LLC or an approved equal. 3. Floor system manufacturer shall be solvent with no bankruptcy proceedings the previous seven (7) years. 4. Carbon Evaluation must be inclusive and based on all corporate facilities; offices and mills. 5. Floor system manufacturer and flooring shall be independently verified by the guidelines of the ISO 14064-1:2006 World Resource Institutes Greenhouse Gas Protocol, Scope 1, 2 and 3. 6. Floor system manufacturer and flooring shall be independently verified by the guidelines of the ISO 14040:2006 and ISO 14044:2006 Life Cycle Assessment (LCA), confirming a negative carbon footprint. 7. Floor system manufacturer and flooring shall be registered in the Collaborative for High Performance Schools (CHPS) Product Database. 8. Flooring system shall be independently verified to meet or exceed the SCORES criteria for environmental design and athletic performance: Sustainable Construction of Renewable Engineered Surfaces.

Page 2 of 4 9. Floor system manufacturer must provide a Life Cycle Assessment and an Environmental Product Declaration (EPD) in accordance with the Product Category Rule Version 2.2014. 10. Floor system manufacturer must be FloorScore Certified in accordance with CDPH 01350. B. Floor Contractor/Installer requirements 1. The flooring contractor must be approved by Action Floor Systems, LLC. 1.04 SUBMITTALS A. Manufacturers product data: Submit ActionCush II specification sheets. B. Samples: Submit one (1) sample of ActionCush II, if requested by architect. C. Maintenance literature: Submit one (1) copy of manufactures maintenance instructions. 1.05 WORKING CONDITIONS A. The wood flooring shall not be installed until all masonry, plastering, tile, marble and terrazzo work is completed, and overhead mechanical trades and painters have finished in wood floor area. The building must be reasonably dry; all openings must be closed in; permanent heating and air conditioning installed and operating. B. The concrete subfloor shall be determined dry by industry standard testing procedures, free of foreign materials and turned over to the Flooring Contractor broom clean. Moderate room temperature of 65 degrees (18 C) or more shall be maintained a week preceding and throughout the duration of the work. Humidity conditions within the building shall approximate the humidity conditions that will prevail when the building is occupied. C. Permanent heat, light and ventilation shall be installed and operating during and after installation, maintaining a range of temperature and humidity compatible with the expected low and high moisture content of the flooring. The wood moisture content range is determined by the flooring contactor based on the facility s mechanical controls and geographical location. D. Flooring must be stored in a dry, well-ventilated area, not in contact with masonry, to acclimate to building conditions and shall be installed at moisture content compatible with the normally expected environmental range of temperature and relative humidity achieved while the facility is occupied. E. Industry standards recommend maintaining indoor relative humidity between 35 percent and 50 percent, and air temperatures between 55 degrees and 75 degrees year-round. By limiting wide swings in atmospheric conditions inside the facility, the expansion and contraction of the flooring system will be limited as the flooring is manufactured at a moisture content most compatible with this range. A 15 percent fluctuation in indoor relative humidity will not adversely affect the maple. Excessive shrinkage and/or expansion may occur with indoor relative humidity variations that exceed 15 percent. T h e g eographical region and HVAC determine the typical range of temperature and humidity for each facility. In buildings where air conditioning is not available, the use of circulating or venting fans will help facilitate excessive shrinkage or expansion. F. General Contractor shall lock floor area after floor is finished to allow proper cure time. If general contractor or owner requires use of gym after proper cure time, they shall protect the floor by covering with non-marring craft paper or red rosin paper with taped joints until acceptance by owner of complete gymnasium floor. 1.06 WARRANTY A. Action Floor Systems, LLC. warrants the material it ships to be free from defects in materials and workmanship for a period of one year and the flooring installer warrants the installation of the flooring to be free of defects in materials and workmanship for a period of one year. The exclusive remedy under this warranty shall be replacement of defective material supplied by Action Floor Systems, LLC. or correction of defective installation by the flooring installer.

Page 3 of 4 All implied warranties of merchantability or fitness for intended use are limited to the period of this warranty. This warranty excludes consequential damages. B. This warranty does not cover damage caused by fire, winds, floods, chemicals, or other abuse, or by failure of other contractors to adhere to specifications, or neglect of reasonable precaution to provide adequate ventilation during hot and humid weather. This warranty also excludes damage due to excessive dryness or excessive moisture from humidity, spillage, migration through the slab or wall or any other source. This warranty also excludes damage to floors due to ordinary wear and tear, faulty construction of the building, (other than the flooring installation), separation of the concrete slab underlying the floor, settlement of the walls, or use of water on the floor. C. During the warranty period, the floor cannot be coated without the permission of the floor contractor. PART 2 PRODUCTS 2.01 MATERIALS A. Flooring 1. Flooring shall be Northern Hard Maple standard strip flooring, 25/32" x 2-1/4" (20mm x 57mm) or 1-1/2" (38mm), TGEM, MFMA grade marked & stamped as manufactured by Action Floor Systems, LLC. 2. Grades available are MFMA 1st, 2nd&Btr. 3rd&Btr. and 3rd grade. 3. Long Length Strip Flooring by Action Floor Systems, LLC (optional). 4. FSC Certified lumber (optional). 5. Expansion Ridge Technology (ERT) 1/64 milled expansion spacer (optional). 6. Factory Sand and Seal Long Length Strip Flooring (optional). B. Subfloor 1. Vapor barrier shall be 6-mil polyethylene. 2. ActionCush sleepers shall be laminated 1-1/2 x 2-1/2 x 8-0 (38mm x 64mm x 2.4m), each with eight pads attached as supplied by Action Floor Systems, LLC. Option: Spruce, Pine or Fir sleepers, nominal size 2" x 3" x 4'(38mm x 64mm x 1.2m), surfaced to uniform thickness, kiln dried to 12% moisture content or less, each with five pads attached. 3. Action Cush E resilient pads shall be approximately 3/8" x 2 x 2 (10 x 50 x 50mm). Option: 5/8" (16mm) Action Cush E pads or 7/16 (10mm) AirTech II Pads. C. Fasteners 1. Flooring fasteners shall be 2" (50mm) cleats, or 15-gauge coated staples. D. Wall Base 1. Wall base shall be 3" x 4" (76mm x 102mm) vented cove base with pre-molded outside corners (specify black or brown), as supplied by Action Floor Systems, LLC. E. Protective Floor Cover (optional) 1. Action AirRide cover system with patented air blower system. System includes Phthalatefree, seamless 10-0 wide, 20.5 ounce vinyl covers and A-frame rack. PART 3 - EXECUTION 3.01 INSPECTION A. Inspect concrete slab for proper tolerance and dryness reporting any discrepancies in writing to the general contractor. B. All work to put the concrete slab in acceptable condition shall be the responsibility of the general contractor. C. Slab shall be broom cleaned by the general contractor. 3.02 INSTALLATION A. Cover concrete slab with polyethylene lapping edges 6 (150mm) and seal with adhesive or 2 (50mm) duct tape.

Page 4 of 4 B. Place the ActionCush sleepers end-to-end in a brick pattern at right angles to the intended direction of the finished flooring with end joints staggered a minimum of 24"(600mm) and fasten overlapping ends. The sleepers shall be spaced 12"(300mm) on center for 33/32 (27mm) flooring, and 9 (229mm) on center for 25/32 (20mm) flooring. When 3 rd &Btr. or 3 rd grade flooring is specified, sleepers shall be spaced 8 (203mm) on center for both 25/32 (20mm) and 33/32 (27mm) flooring. Allow 2 (50mm) voids at perimeter and vertical obstructions. C. Machine nail strip flooring into the sleepers, parallel to the long dimension of the area, nail approximately 8 (203mm) - 12 (300mm) on-center. Provide adequate expansion at regular intervals across the floor during installation as dictated by the average humidity conditions of the area according to the recommendations of the local Action Floor Systems, LLC. flooring contractor. Allow 2" (50mm) expansion voids at perimeter and all vertical obstructions. Provide 2" (50mm) expansion voids at perimeters and all vertical obstructions. D. Install solid blocking at doorways, bleacher stack areas or under portable goals as needed. 3.03 FLOOR SANDING A. Use coarse, medium and fine grade sandpaper. B. After sanding, buff entire floor using 100-grit screen or equal grit sandpaper, with a heavy-duty buffing machine. C. Vacuum or tack floor before first coat of finish. D. Floor shall present a smooth surface without drum stop marks, gouges, streaks or shiners. 3.04 FINISHING A. Inspect entire area of floor to ensure that the surface is acceptable for finishing, completely free from sanding dust and perfectly clean. B. Apply seal and finish per manufacturer's instructions. C. Buff and vacuum or tack between each coat after it dries. D. Apply game lines accurately after the seal coat, after buffing and vacuuming. Lay out in accordance with drawings. For game lines, use current rules of association having jurisdiction. Lines shall be straight with sharp edges in colors selected by the architect. Game line paint shall be compatible with finish. 3.05 BASE INSTALLATION A. Affix rubber base to wall with recommended adhesive or screws. Miter all corners carefully. Use pre-molded outside corners. Install aluminum thresholds as required, anchoring firmly in concrete floor beyond limits of wood flooring. 3.06 CLEAN UP A. Clean up all unused materials and debris and remove from premises, properly dispose of all waste materials. 3.07 MAINTENANCE A. Upon completion of floor installation, the owners, attendants or individuals in charge and responsible for the upkeep of the building are to see that the care and maintenance instructions of the MFMA are followed. Failure to do so may void warranty. NOTICE: IT IS THE POLICY OF ACTION FLOOR SYSTEMS, LLC. TO CONTINUOUSLY UPDATE AND IMPROVE OUR PRODUCT LINES. THEREFORE, WE RESERVE THE RIGHT TO CHANGE, MODIFY OR DISCONTINUE SYSTEMS, SPECIFICATIONS AND ACCESSORIES OF ALL PRODUCTS AT ANY TIME WITHOUT ANY NOTICE OR OBLIGATION TO ANY PURCHASERS. Rev 10/2016