PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

Similar documents
3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

DR1000 Flying Laboratory, Drone Environmental Monitoring

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Online Gas Analyzer / Monitor

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Sensor unit MC2 for toxic gases and oxygen with analog output

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Instructions for. Pro AND. Pro. Indoor Air Quality Monitors. Cropped picture here

MiniWarn. Fits Your Application. Intelligent. Rugged. Flexible. Ergonomic. Easy to use. Multi-Gas Instrument

A World of Gases. A Single Transmitter. UniSens. Universal 2-Wire Gas Transmitter...

The Leader in Performance Indoor Air Quality Measurements

???? Spot Check Measurement Simple, accurate, reliable

MRU Instruments, Inc. Houston, Texas Tel.: (844) (Toll Free)

Technical Note TN-114 rev 16 wy/wh.11-04

GAS 3050P NDIR FLUE GAS

testo 340 Speed, power & precision in industrial combustion analysis.

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Stack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility

Monitoring for Toxic VOCs in Oil Industry Applications

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

BioTector System-C. Online TOC Analyzer for Clean Water Applications

Fpollutant-free zero air for analytical

Sensor Specifications and CroSS- Sensitivities

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Sensor Technologies used in Portable Gas Monitors. HA University

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

TWIN LASER PARTICLE COUNTER

3SP_CO_1000 Package

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

The Ton-Tel Weighbridge

Compact flue gas analyser: testo 300 M-I

Paper 4: Environmental Chemistry Paper 23: Air pollution controls, their chemistry and continuous monitoring instruments

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Data Logging Solutions from Lascar Electronics

Dekati. ELPI Electrical Low Pressure Impactor. Real-time particle size distribution Wide particle size range Wide range of applications

Crowcon Technical Note

Smarter Choices, Better Air.

ph & TDS instrumentation 2017 specialists in temperature measuring equipment for over 30 years

testo 350 M testo 350 XL

Crowcon Technical Note

A Multi-Element Smart Gas Sensor

AWS F1.5M:2003 An American National Standard. Methods for Sampling and Analyzing Gases from Welding and Allied Processes

FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

Carbon / Sulfur Analyzers

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

HY-ALERTA 500 Handheld Hydrogen Leak Detector

Stack Air Emission Test Report

Prima PRO process mass spectrometer

Explore the future of osmometry. Multi-Sample Micro-Osmometer

1080 Total Organic Carbon Analyzer

For Safe and Delicious Water

Ambient Air Monitoring Systems

Gas concentrations in the air

TVOC Heated FID VE 7

testo 330 Flue gas analysis with increased convenience and safety

SCOTT PRO 2 CARTRIDGE FILTERS TECHNICAL DATA SHEET

Ambient Air Quality Monitoring Baseline Report, Kirby Misperton A Wellsite, KM8 Production Well

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

ProFoss for in-line process analysis of dairy powder

Solutions. Integrated Analyzer Systems & Services. Your Global Partner For Customized Analytical Solutions

Palletizing robots for the consumer goods industry

4Ch Real time / Duplex LCD Combo DVR

Process Total Organic Carbon Analyzer

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

VOCs, CO 2, LEL, H 2 S, CO, O 2, SO 2, PH 3, NH 3, NO 2, HCN, Cl 2, ClO 2, O 3. Protect yourself. General Specifications

TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Using the PPM2 Portable Trace Moisture Transmitter

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

ICAC MARAMA Portable Emission Analyzers

Instruction Manual Dräger MSI EM200-s

Weighing Terminals. IND560x Terminal Comply Weigh Connect Control. Uncompromising Weighing Performance for Hazardous Areas

DR 1900 PORTABLE SPECTROPHOTOMETER

Transfield Services Limited

EUROλYZER STx. Flue Gas Analyzer. BlueLine

Del-Monox Breathing Air Purifiers DM Series

TECHNICAL DATA SHEET

Major Air Pollutants

AlgaeTorch. The handy measurement instrument for rapid deployment. Fast and simple algae monitoring

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

UV400 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Online data sheet SMC209 C CEMS SOLUTIONS

Moisture Meters For. Flooring

Fine particle measuring system

Portable Air Quality Monitors

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification.

gravity (9.8 m/s2) the person is experiencing 1g. If for example, the mass of this person is 85

Multifunction HVAC and IAQ Meter

tempmate. -GS Stay Online and Well-Informed to Avoid Unpleasant Surprises: Cold Chain Monitoring 4.0

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

Process Analyzer. UV Oil in Water Analyzer Model W-800. Credible Solutions for the Oil and Gas Industry

New! Sievers M9 TOC Analyzers

MATERIALS OF CONSTRUCTION

Transcription:

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT Real-Time Direct Reading Time History Data Logging Portable or Stationary

When it comes to monitoring a variety of air quality hazards, Quest Technologies has made it easy with the new EVM-7. The EVM-7 lets you simultaneously measure particulates, volatile organic compounds, toxic gas, carbon dioxide, relative humidity, temperature and air velocity. By offering two instruments in one, you'll enjoy a lower cost of ownership and the freedom of not lugging around multiple instruments from site to site. And that's just the beginning. Key Features of the EVM-7 Include: Simultaneous Measurement of Particulate and Gas Concentrations Reduces the need for multiple instruments and lowers the cost of ownership. Dial-in Rotary Impactor Twist and click selection of particulate settings: PM2.5, PM4, PM10 or TSP.* Eliminates disassembly and reduces the need for external cyclones. 90 Light Scattering Photometer Mass concentration engine offers real-time measurement of particulates. Built-in Sampling Pump for Gravimetric Analysis Allows user to insert a 25 or 37 mm cassette to capture particulates for laboratory testing. *Within the instrument s measurement range.

Easy to use and packed with features to make your life easier. As with many Quest instruments, the EVM-7 provides a wide range of features, from basic monitoring to advanced functions. At Quest, we pride ourselves in producing monitors that are just as packed with features as they are easy to use. And the EVM-7 is no exception. Its large display and buttons, simple screens, straightforward commands and robust software solutions put all of the EVM-7's capabilities right at your fingertips. Here are just a few highlights: Factory calibrated relative to ISO 12103-1, A2 (Arizona Road Dust) Site correction factors for various particulates (user supplied) Auto run and security code protection for unattended sessions Carbon dioxide (CO 2 ) trending algorithms for calculation of room air exchange rates (with QuestSuite Professional II software) Dew point readings for analysis of airborne moisture percentage Smart sensors which are auto-detectable at power on Real-time measurement with once per second update rate Time history data logging Trend graphing for all parameters Standard Quest menu driven user interface with 10 pushbuttons / 4 softkeys User selectable digital output for external functions Displayed measurements of Level, Minimum, Maximum, Average, Short-Term Exposure Level (STEL) and Time Weighted Average (TWA) No matter where you go, you'll have Quest's proven track record of reliability right by your side. The true beauty of the EVM-7 is its versatility. With its rugged, yet lightweight design, the EVM-7 is well suited for a variety of applications and situations, including: Work site monitoring Industrial hygiene surveys Military site evaluation Internal vehicle sampling (aircraft, trains) Construction / mining site monitoring Engineering studies Industrial fence line monitoring Remediation sampling IAQ walk through & stationary studies Air quality assessment VOC screening and monitoring Regulatory compliance

Removal of the back cover allows for convenient access and customization of gravimetric filter cassette for sample collection. ADDITIONAL MODELS include the EVM-3 and EVM-4 For those customers who do not require the full functionality of the EVM-7. EVM-3 Specializes in real-time direct reading of particulate concentrations. This tri-sensor unit utilizes the builtin sampling pump and dial-in impactors for real-time mass concentration readings. - Particulates (mass concentration) - Temperature - Relative Humidity EVM-4 Multi-sensor unit designed for typical indoor air quality investigations. Simultaneously track, log and monitor multiple indoor air quality parameters including room air exchange rates and dew point. - Toxic Gas (choose from nine sensors) - Relative Humidity - Carbon Dioxide - Temperature

MEASUREMENT SCREEN EXAMPLES PARTICULATE CONCENTRATIONS SCREEN - Displays user-adjustable impactor setting and six simultaneous measurements. TREND SCREEN - Provides synopsis of logged measurement values in a graphical format. Available for each parameter. COMPOSITE SCREEN - Displays available parameters for a snap-shot overview of measurement values. SENSOR SPECIFICATIONS METHOD BASE UNITS DISPLAY RESOLUTION DISPLAY RANGE ACCURACY REPEATABILITY PARTICULATES: 90 Light Scattering / Integrating Photometer mg / m 3 0.001 0.000-199.9 +/-15% (rel ARD*) Particulates Size Range µm N/A 0.1-10 ** VOC: (PID) 10.6eV Photo-Ionization Detector CO2: NDIR (Non-Dispersive Infrared) TOXIC ELECTROCHEMICAL SENSOR: CO - Carbon Monoxide Sensor Cl 2 - Chlorine Sensor EtO - Ethylene Oxide Sensor HCN - Hydrogen Cyanide Sensor H 2 S - Hydrogen Sulfide Sensor NO - Nitric Oxide Sensor NO 2 - Nitrogen Dioxide Sensor O 2 - Oxygen Sensor SO 2 - Sulfur Dioxide Sensor TEMPERATURE: ppm 0.01 0.00-2,000 ppm 1 0-20,000 ppm 1 0-1,000 ppm 0.1 0.0-20 ppm 0.1 0.0-20 ppm 0.1 0.0-50 ppm 1 0-500 ppm 0.1 0.0-100 ppm 0.1 0.0-50 % 0.1 0.0-30 ppm 0.1 0.0-50 (rel Isobutylene) at calibration level +/-2% +/-50 ppm between 0-2,500 CONVENIENT SENSOR ACCESS Junction Diode deg C 0.1-10.0-60.0 +/- 1.1 deg C deg F 0.1 14.0-140.0 +/- 2 deg F Removeable sensor bar provides easy access to toxic electrochemical sensors. RELATIVE HUMIDITY: Capacitive AIR VELOCITY: % humidity 0.1 0.0-100 +/-5% RH* between 10%-90% Omni-directional Heated Thermistor Windprobe meter/sec feet/min 0.1 1 0.0-20 0-3940 +/-0.12 m/s + 4.5% +/-23.6 ft/min + 4.5% *ARD - Arizona Road Dust, RH - Relative Humidity **The photometer can detect particulates up to 100 µm; however accuracy is reduced for sizes greater than 10 µm.

SPECIFICATIONS FOR THE EVM SERIES GENERAL DISPLAY LANGUAGES: USER INTERFACE: DISPLAY TYPE: SOFTWARE COMPATIBILITY: STANDARDS: PARTICULATE IMPACTORS SIZE FRACTIONS: FLOW RATE: DISPLAYED DATA MEASUREMENTS: REAL-TIME MEASUREMENT: TIME HISTORY DATA LOGGING INTERVALS: English, French, German, Italian, Portuguese and Spanish 10 pushbuttons and 4 softkeys, menu driven Transreflective 128 X 64 LCD with backlighting QuestSuite Professional II CE Mark and RoHS compliant PM2.5, PM4, PM10 or TSP (within the instrument's measurement range) 1.7 L/min Level, Minimum, Maximum, Average, Short-Term Exposure Level (STEL), Time Weighted Average (TWA) Once per second display update rate Seconds: 1, 5, 15, 30 / Minutes: 1, 5, 10, 15, 30, 60 The System Solution Software TREND GRAPHING INTERVALS FOR ALL PARAMETERS: STATUS INDICATORS: AVERAGING TIME: PHYSICAL CHARACTERISTICS SIZE: WEIGHT: HOUSING: TRIPOD MOUNT: OPERATING CONDITIONS TEMPERATURE RANGE: PRESSURE RANGE: RELATIVE HUMIDITY RANGE: STORAGE CONDITIONS TEMPERATURE: HUMIDITY: ELECTRICAL CHARACTERISTICS INTELLIGENT SENSORS: BATTERY PACK: BATTERY LIFE: Minutes: 1.5, 3, 15 / Hours: 1.5, 3, 8, 12, 24 Battery, Run, Stop, Overload and UnderRange 1 to 30 seconds 19cmX19cmX7cm(7.5 X7.5 X2.75 ) 1.3 kg (2.9 lb) Static dissipative ABS Polycarbonate housing Standard photographic mount on bottom, 1/4-20 screw heads 0 C to 50 C (32 F - 122 F) 65 kpa to 108 kpa 10% to 90% non-condensing -20 C to 60 C (-4 F to 140 F) 0% to 95% RH, non-condensing Auto-detectable when inserted at power-off mode Rechargeable lithium-ion Minimum of 8 hours under continuous operation QuestSuite Professional II Software provides the ultimate System Solution for recording, reporting, charting and analyzing exposures to a variety of occupational and environmental hazards. With QuestSuite, there are no more headaches of learning different programs or switching between multiple software applications. Just one simple, yet robust system solution for all of our rugged Quest instruments. EXTERNAL DC POWER INPUT: 10 to 16 Volt power inlet (nominal 12V DC) 1.5A POWER ADAPTER: Universal AC adapter 100 to 240 Volt AC, 50-60 Hz *All Specifications Subject to Change UK SALES & SERVICE CENTRE Pioneer Road, Faringdon, Oxon, SN7 7BU Tel: 01367 241675 Fax: 01367 242491 www.shawcity.com