WILKINSON ELEMENTARY SCHOOL

Similar documents
PLUMMER ELEMENTARY SCHOOL

LECKIE ELEMENTARY SCHOOL

LASALLE - BACKUS EDUCATION CAMPUS

LEWIS ELEMENTARY SCHOOL

School Without Walls

COOLIDGE SENIOR HIGH SCHOOL

LOGAN SCHOOL SCHOOL WITHOUT WALLS AT LOGAN

Facility Assessment Report, Montgomery Independent School District

Facility Improvements

BRUCE MONROE AT PARK VIEW ELEMENTARY SCHOOL MODERNIZATION PROPOSED MAIN ENTRY - EXTERIOR RENDERING

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Material Report - [Trade Contractors] for plan: [E:\SoftPlan14\Projects\Sample Drawings.spf\2-Storey sqft.spf] Page 1 of 5

HISTORIC PLAN, FLOOR PLANS, AERIAL PHOTOS

Cheldelin Middle School

Madison School District. Strategic Five-Year Facility Maintenance Plan

The parking lot is in varying condition depending upon location. The vehicular and pedestrian traffic flow is generally good.

DeKalb County School District/Stadiums Avondale Stadium Final School Assessment Report May 20, 2016

2 Main School Building BLDG-124A Building Purpose Building Area Administrative, Classrooms, Cafeteria and Gymnasium 61,905 SF Inspection Date June 28-

CITY OF NOVI. Police Department

BOWIE LEARNING CENTER

INSPIRE each student to develop a strong

Mount Vernon Elementary School Grades PK 5

Facilities Condition Assessment Qualcomm Stadium

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Completed. Project. Melbourne High School. Comprehensive Additions and Renovations

LEVEL TWO NUMBERS AND TITLES. Introductory Information. Bidding Requirements. Contracting Requirements. Facilities and Spaces. Systems and Assemblies

CENTENNIAL SCHOOL DISTRICT

Velma F Thomas Early Childhood Center

John T Pirie Fine Arts & Academic Center ES 650 E 85th St Chicago, IL 60619

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Manufacturing Facilities Proposal

Property Condition Assessment

3D Home Improvement and Inspection Services, Inc

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI.

Classroom Facilities Assessment Program. Building Phone: Enrollment Date is the date in which the current enrollment was taken.

Division 09 FINISHES TABLE OF CONTENTS

LANSDOWNE HIGH SCHOOL RENOVATION PRELIMINARY DESIGN PRESENTATION. The Board of Education of Baltimore County Verletta White, Interim Superintendent

CODE COMPLIANCE PLAN REVIEW PROCEDURES

STRUCTURAL CONDITION ASSESSMENT

A Design-Build Project: Repairing the Courthouse Square Complex

CHARTRES COURT Washington Avenue Houston, Texas ChartresCourtHouston.com CHARTRES COURT LLC

Subject: Lucretia Mott School No. 3 Rehabilitation. Figure 1 Figure 2 Figure 3

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

Design Advisory Committee Meeting #1. December 6, 2016

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Appendix A. Facilities Condition Assessment

SECTION ALTERNATES

OWNER S REPONSIBILITIES AND PREPARATION INSTRUCTIONS. Schedule "C"

Morehouse School of Medicine

Cost Estimate Details

A/E Design Deliverable Checklist

Structural Inspection

Classroom Facilities Assessment Program. Building Phone: Enrollment Date is the date in which the current enrollment was taken.

FLOORPLAN /ELEVATION SQ.FT. BDRM BATHS GARAGE BASE PRICE

CARL E. SCHLUTER ELEMENTARY SCHOOL

Paul Laurence Dunbar Career Academy High School 3000 S King Dr Chicago, IL 60616

*Additional Projects were not part of the voter-approved 2006 Bond. They were able to be completed due to savings from other projects.

Pembridge The Country Club Collection TOWNHOMES AT CRYSTAL SPRINGS

Building Inspection Report

MISSOURI DEPARTMENT OF TRANSPORTATION ATTACHMENT G FACILITIES EXPECTATION FORM

Total Building Area: 1964 Construction 30,140 square feet 1976 Construction 36,787 square feet 66,927 square feet

Homes at Pine Ridge - NEW CONSTRUCTION SPECS

Highland Park. Exceptional Interiors (cont.) Green Technology. Designer Kitchen Features. Distinctive Exterior Features

THE RESTORE LOUISIANA REIMBURSEMENT ESTIMATE

Mt. Jumbo Gymnasium. Facility Condition Survey Report. Prepared August 2014

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours

MISSOURI DEPARTMENT OF TRANSPORTATION ATTACHMENT G REST AREA/WELCOME CENTER AND TRUCK PARKING FACILITY PERFORMANCE MEASURES

Davis Frame Co., Inc. Construction Budget Considerations

U.S. Department of Housing and Urban Development Community Planning and Development

Rebuilding your Home after the storm? Adding on, renovating, or remodeling your home? Here's information YOU need to know about the 50% Rule.

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Before You Start Renovating Your Bathroom

OFFICE OF EDUCATIONAL FACILITIES FLORIDA BUILDING CODE SECTION 423 APPLICATION MATRIX

TERMINAL BUILDING EVALUATION

Inspection Report. 1 of 8

James B Farnsworth Elementary School 5414 N Linder Ave Chicago, IL 60630

RESIDENTIAL CONSTRUCTION PERMIT FEES

(August 2015) UNIFIED FACILITIES GUIDE SPECIFICATIONS **************************************************************************

Construction Summary

DRAFT. Baker Center Special Campus Site Summary 64,153 SF. Introduction

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)

Healthy Homes Provisions of Lansing, Michigan Ordinances Extracted from by National Center for Healthy Housing

SUBSTANTIAL IMPROVEMENT

Checklist #1 Questions to Ask Real Estate Agents

CHECKLIST Inspecting a Garage

Presented by The National Association of Certified Home Inspectors Chicago Chapter

Jane Addams Elementary School S Avenue H Chicago, IL 60617

RE-USE AND REPURPOSING OF UNDERUTILIZED BUILDINGS: STRATEGIC PLANS FOR COMPETITIVE RESEARCH ENVIRONMENTS

SACRAMENTO CITY UNIFIED SCHOOL DISTRICT Sustainable Facilities Master Plan

Revised Central Scheme 1 Existing Building Exterior Upgrades Interior Renovation Areas: Scope of Interior Renovation: 100% Three Story Academic Additi

LOOSE FILL ASBESTOS INSULATION

Basement Renovation Guide For Residential Dwellings

Penns Valley Area School District

BUILDING ASSESSMENT REPORT for NMSU GREENHOUSES at NEW MEXICO STATE UNIVERSITY LAS CRUCES, NEW MEXICO

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION


LOVEJOY Independent School District

A/E Design Deliverable Checklist

Building Construction Occupations

Transcription:

INITIAL YEAR BUILT 1976 BUILDING AREA 144,900 SF CURRENT PROGRAM CAPACITY 508 ENROLLMENT 2008 451 WARD 8 PROPOSED PROGRAM CAPACITY 600 Site Plan WILKINSON - 1

PROPOSED PROGRAM PROFILE GRADE CONFIGURATION PK-5 (Swing) SQ. FT. (EXISTING) 144,900 SQ. FT. (ADDITION) TYPE PROPOSED TYPE PROPOSED Pre-School 2 Pre-Kindergarten 4 Kindergarten 4 1 4 2 4 3 4 4 3 5 3 Gym 1 Bleachers Locker Rooms 2 Gym-Cafeteria Cafetorium Gym-Cafetorium Gym-Auditorium Auditorium Multi-Purpose 1 Cafeteria Kitchen Services 1 Special Education 3 Media Center 1 Administrative/Health Suite 1 Computer Lab 1 OT/PT 1 Science Lab Art 1 Music 1 Teacher Workroom 1 Parent Resource 1 Proposed Planning Profiles The inventory of spaces listed here is intended to outline the program of educational and support spaces necessary to support the proposed program capacity. Individual educational specifications and facility programs will be developed with the School Improvement and School Planning / Design teams at the time of project initiation. WILIKINSON - 2

CONDITION ASSESSMENT Building System ADA Compliance Conveying Systems Electrical Exterior Finish HVAC 2008 Rating Interior Finish Plumbing Roof Structure Technology Good Poor Good Condition Assessment The body of information summarized below is based on a detailed facility condition assessment completed in 2006 and updated by visual observations conducted in 2007. Improvement initiatives completed by OPEFM in 2007 and 2008 are noted in red text in each section. An overall summary of work completed under various OPEFM programs is provided at the end of the condition assessment. Condition Scorecard These ratings reflect the overall condition and level of replacement need for an entire system, in adherence with the Facility Condition Index (FCI) System, categorizing systems as Good (FCI <.25), (FCI 0.25 0.50), Poor (FCI 0.51 0.85), or Unsatisfactory (FCI >.86). Comments: 1 Conveying System There is a functioning elevator in this building. 2008 Receiving School (R/S): Elevator repair. 2 Electrical 3 Exterior Finish 4 Structure 5 HVAC 6 Interior Finish Main service, branch circuit panels, and branch circuit wiring are original mid 1970's and in good condition. About 90% of the light fixtures are original 2'x4' fluorescent grid fixtures in fair condition and can be maintained. 2007: General power repairs, replace/repair light fixture. 2008 R/S: Upgraded electrical outlets throughout building as required to support new configuration. New lighting fixtures throughout. There is damage in the exterior soffit of the building, under the overhead where the second floor cantilevers out into the space. 2007: Replaced exterior lighting. 2008 R/S: Broken window panes replaced, damaged windows replaced. General exterior elevation cleanup. A number of structural conditions have been observed which in our opinion required further investigation to properly understand the conditions and to determine the appropriate remedial action to be taken. Three potential structural problems have been observed: 1 - In Stair 210 there is a crack in the wall. 2 - In space #4 there is a concrete beam with exposed rusted steel. 3 - Signs of structural damage were noticed in the northeast corner of space #213. At this location, potential settlement in the foundation and cracks in the wall and ceiling above have been sighted. The space #213 is located in the basement level adjacent to the Boiler Room. Please note that space #213 was discovered when assessing this building. The Basement Plan we originally received did not show this space. It showed "unexcavated". Please review our updated basement plan and notes. We recommending further structural investigation take place. Complaints of too hot (winter) or too cold (summer). All air handling equipment is in fair condition but needs to be replaced soon. There is no means of zone controlling causing unacceptable space temperature. 2007: Repairs to Boilers and classroom units. Repairs to AC Central Unit. 2008 R/S: Upgraded system components as required to ensure acceptable operations. Interior finishes are 40% Poor (flooring, doors, and some walls) and 60% (ceilings and walls). 2008 R/S: New interior partitions, wall coverings, flooring, ceiling system and ceiling tiles, new doors, hardware, etc., as required to support new configuration. WILIKINSON - 3

7 Plumbing 8 Roof 9 ADA Compliance 10 Technology 11 Grounds Plumbing is in fair condition. All of the student's toilets are ADA compliant while the adult's toilets are NOT. Some fixtures needed to be upgraded or replaced. 2008 R/S: Upgraded system components as required to ensure acceptable operations. New restrooms as required to support new configuration. The roof generally is in fair condition, but there are isolated repairs that are required to prevent further deterioration of interior finishes. 2008 R/S: Repaired / replaced leaking roof portions, including flashing, gutters, downspouts and roofing membrane. The building is accessible to handicapped persons and there are handicapped bathrooms within the building, however there is a need for adult ADA compliant bathrooms and a minor upgrading of fixtures and faucets in some of the bathrooms. 2008 R/S: New door hardware, all restrooms are ADA-compliant. Data and video drops are available throughout the facility. Not all rooms were equipped with PC's and TV's. Intercom system is original and should be replaced/ modernized. 2008 R/S: Repairs to P.A. system throughout the building, new computer connectivity to all new classrooms, library, and media center, etc. Elastomer joint filler at retaining wall expansion joints has deteriorated. As a result, soil, water, and vegetation behind the wall protrude through these joints located approximately 60' on center. The playground area needs to be milled and resurfaced to remove remnants of previous playground equipment that posses health and safety issues. Site trees in the playground appear dead and have mold growing on the trunks. Hand rails through the grounds are rusted and need galvanized paint. In general the grounds and athletic fields are in very poor condition. 2008 R/S: New parking area and driveway A/C paving and striping, repair damaged concrete hardscape. WILIKINSON - 4

RECENT HISTORY OF MODERNIZATION 2007 TARGETED REPAIRS Interior Finishes - Door Replacements/Door Hardware Repair Interior Finishes - Drywall & Ceiling Repairs Interior Finishes - Select Carpet Replacements/Flooring Repairs Interior Finishes - Painting/Plastering Plumbing Repairs - Restrooms/Fixtures & Flush Valves; Water Fountains Electrical Repairs - Lighting & Power Mechanical Repairs - AHU & Boiler Repairs, HVAC Filter Replacement Exterior Work & Building Envelope - Lighting, Site Work, Playground, etc. Other Work Orders 2008 STABILIZATIONS Emergency Security Repair Work (Exterior Lighting Replacements) SCHOOL CONSOLIDATIONS & RECEIVING SCHOOLS (I,II) Classrooms Configurations Site Work - (concrete, masonry, painting, fencing) Wood and Plastics - (Carpentry) Thermal and Moisture Protection (Roofing) Doors and Windows Finishes - (Interior Painting) Mechanical Electrical Work Orders Planning Design Pre-Construction In Progress Completed WILIKINSON - 5

Basement Concept Plans These floor plans represent planning concepts for proposed facility use, aligning the proposed program capacity, the proposed planning profiles, and the conceptual reconfiguration of the building. Each project is subject to a formal design process, incorporating input from the School Improvement team at the time of project initiation. WILIKINSON - 6

First Floor Concept Plans These floor plans represent planning concepts for proposed facility use, aligning the proposed program capacity, the proposed planning profiles, and the conceptual reconfiguration of the building. Each project is subject to a formal design process, incorporating input from the School Improvement team at the time of project initiation. WILIKINSON - 7

Second Floor Concept Plans These floor plans represent planning concepts for proposed facility use, aligning the proposed program capacity, the proposed planning profiles, and the conceptual reconfiguration of the building. Each project is subject to a formal design process, incorporating input from the School Improvement team at the time of project initiation. WILIKINSON - 8

Penthouse Concept Plans These floor plans represent planning concepts for proposed facility use, aligning the proposed program capacity, the proposed planning profiles, and the conceptual reconfiguration of the building. Each project is subject to a formal design process, incorporating input from the School Improvement team at the time of project initiation. WILIKINSON - 9