SUMMER VENTILATION OF POULTRY HOUSE FOR CHICKEN FATTENING IN CFD MODELLING.

Similar documents
HEAT RECUPERATION IN VENTILATION SYSTEM OF BASEMENT LABORATORY

P. Rohdin 1, M. Johansson 2, J. Löfberg 3, M. Ottosson 4. Abstract

Live Transportation Research and Improvement Initiatives

External Environment and Indoor Microclimate

A Solar Wall System Utilized in Rural Houses of Northeast China

Numerical Modelling of Air Distribution in the Natatorium Supported by the Experiment

DISPLACEMENT VENTILATION

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

Thermal Management of Densely-packed EV Battery Set

Performance Analysis for Natural Draught Cooling Tower & Chimney through Numerical Simulation

THE STUDY OF THE BAKING OVENS BY COMPUTER SIMULATION

40-Ton Articulated Truck Cooling System Modelling Using STAR-CCM+

PERFORMANCE ANALYSIS OF NATURAL DRAFT WET COOLING TOWER AT OPTIMIZED INJECTION HEIGHT

Using Experimental Measurements of the Concentrations of Carbon Dioxide for Determining the Intensity of Ventilation in the Rooms

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Effect of Rotation Speed of a Rotary Thermal Wheel on Ventilation Supply Rates of Wind Tower System

These systems are offered an alternative to overhead, mixing ventilation (MV), systems. Due to their potential advantages which are [1]:

The Suitability of Fire-Field Modelling for Enclosure Fires involving Complex Solid Fuel Loads. STIFF Meeting Sept 2006 Stuart Winter

Ammonia emission from organic pig houses determined with local parameters

A calculation model for Trombe walls and its use as a passive cooling technique

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Optimising design of secondary combustion chambers using CFD

Propane Saving in Poultry Farm through Waste Heat Recovery System

Validation of Numerical Modeling of Air Infiltration through Building Entrance Doors

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

SCR Retrofit Improves Performance

ARCHIVES OF CIVIL ENGINEERING, LX, 1, 2014 NUMERICAL INVESTIGATIONS OF EFFECT OF INDOOR AIR QUALITY ON THERMAL COMFORT IN RESIDENTIAL BUILDINGS

OPTIMIZED DESIGN FOR HEAVY MOUND VENTURI

CFD modeling of airflows and contaminant transport in an aircraft cabin

Numerical Investigation of the Integration of Heat Transfer Devices into Wind Towers

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

PS Modeling airflow in outdoor grain pile aeration systems. Introduction

ASSESSMENT OF AIR CHANGE RATE AND CONTRIBUTION RATIO IN IDEALIZED URBAN CANOPY LAYERS BY TRACER GAS SIMULATIONS

Thermally operated mobile air-conditioning system

A STUDY OF CROSS CONTAMINATION OF IN-SUITE VENTILATION SYSTEMS USED IN MULTI-UNIT RESIDENTIAL BUILDINGS

ENERGY SAVING IN BUILDING USING PCM IN WINDOWS

Analysis of the corrosion test process for heat exchangers in corrosion test chambers by CFD simulation

Numerical Investigation of the Flow Dynamics of a Supersonic Fluid Ejector

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

Thermal performance of a closed wet cooling tower for chilled ceilings: measurement and CFD simulation

Substantial factors influencing drivers comfort in transportation

The optimization of the mechanical night cooling system in the office building

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

125BEPM - Building energy performance modeling. Lecture handouts

Heat Transfer Augmentation of Air Cooled Internal Combustion Engine Using Fins through Numerical Techniques

Parameters of the Atmospheric Air in the Dimensioning of Industrial Cooling Tower

125 BEPM. Lecture handouts

COOLING TOWER DESIGN FOR CENTRAL GENERATORS OF CUET, BANGLADESH. Mohammad Sharif Khan, Golam Mainuddin, Abu Sadat Mohammad Sayem, Nadeem Nafis

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Study of water falling film over horizontal drop shaped and inverted drop shaped tubes

IDENTIFICATION OF VENTILATION PROBLEMS IN AN UNDERGROUND BUS TERMINAL IN KOREA

UC Berkeley Indoor Environmental Quality (IEQ)

Design and distribution of air nozzles in the biomass boiler assembly

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

Performance of a counterflow heat exchanger with heat loss through the wall at the cold end

A NEW METHOD FOR REDUCTION OF NH 3 EMISSIONS FROM PIG HOUSING SYSTEMS BY ADDING SULPHURIC ACID TO SLURRY

Reflow Oven. USA HEADQUARTERS:

AIR QUALITY IN COW HOUSES WITH CURTAIN WALL VENTILATION IN FINNISH CLIMATE

Biofiltration is. The average odor. Treating Odor Emissions from Buildings Biofilters

LOCAL VENTILATION SYSTEMS: SOME INVESTIGATIONS ABOUT COMFORT LEVELS AND ENERGY DEMANDS

OFSETTING THE NATURE

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

Flow and Heat Transfer Characteristics in High Porosity Metal Foams

MODELLING THE URBAN MICROCLIMATE AND ITS INFLUENCE ON BUILDING ENERGY DEMANDS OF AN URBAN NEIGHBOURHOOD

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

Livestock climate control systems as a potential ammonia abatement technique

CFD Validation of Carbon monoxide diffusion within a ship vehicle garage

Ventilative Cooling potential tool

ESP-r: INTEGRATED SIMULATION TOOL FOR DESIGN OF BUILDINGS AND SYSTEMS

RETRO-COMMISSIONING OF A HEAT SOURCE SYSTEM IN A DISTRICT HEATING AND COOLING SYSTEM Eikichi Ono 1*, Harunori Yoshida 2, Fulin Wang 3 KEYWORDS

Controls and Software CHORE-TRONICS 2 Controls

PLUME ANALYSIS AND CFD MODELING FOR EFFECTIVE EAF MELTSHOP ENVIRONMENT CONTROL

Numerical Simulation of a Building Envelope with High Performance Materials

Impellers of low specific speed centrifugal pump based on the draughting technology

Energy and Thermal Comfort Management in a Kindergarten School Building in the South of Portugal in Winter Conditions

Controls and Software CHORE-TRONICS 2 Controls

THERMO-HYDRAULIC BEHAVIOUR OF COOLANT IN NUCLEAR REACTOR VVER-440 UNDER REFUELLING CONDITIONS

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

THERMAL ANALYSIS OF CPU WITH VARIABLE BASEPLATE HEAT- SINK USING CFD

Urban greenery: increasing resilience to climate change through green roofs and urban forestry

A Comparative Study of the Thermal Comfort of Different Building Materials in Sana a

Methane emission from naturally ventilated livestock buildings can be determined from gas concentration measurements

Great Ocean Rd Ice Creamery

Design and development of a residential gas-fired heat pump

Heat Transfer Simulation of Impinging Jet with Finned Heat Sink

Energy efficient ventilation systems

ScienceDirect. Influence of the balcony glazing construction on thermal comfort of apartments in retrofitted large panel buildings

Numerical study of the influence of injection/production well perforation location on CO 2 -EGS system

PROJECT COMPLETION REPORT FOR SHORT TERM GRANT A STUDY ON IMPROVING AIR CIRCULATION IN A CONFINED SPACE

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

THERMAL AND STRESS ANALYSIS OF HYPER TARGET SYSTEM *

Solar Energy Technologies

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Transcription:

SUMMER VENTILATION OF POULTRY HOUSE FOR CHICKEN FATTENING IN CFD MODELLING Van Doan Cao 1, Milan Zajicek 2, Pavel Kic 1 1 Czech University of Life Sciences Prague; 2 Academy of Science of the Czech Republic caodoan2006@gmail.com, zajicek@utia.cas.cz, kic@tf.czu.cz Abstract. The aim of this paper is a numerical analysis of ventilation of the buildings for broilers during summer. Ventilation is the most important operation for internal environment to achieve the best performance of chickens. At each stage of growth of the chicken an optimum performance zone exists, in which the chickens use the most of the energy from food for growth. The target temperature for the best performance of broilers during growth changes daily and therefore ventilation is necessary to be modified by a suitable method. During the fattening period the biological production and thermoregulatory ability of chickens change significantly. In summer at the end of the fattening period, the problem of making the internal environment is more significant. The fundamental problem will be solved by using mathematical simulation, and the speed of flow will be determined in the ventilated space. For the research in the airflow, for prediction of the expected speed and air temperatures CFD (computer fluid dynamics) software Fluent was used. The effects of the change of the geometry and outside temperature, the concentration of carbon oxides, ammonia and dust within the hall were also monitored. The examined results of the program Fluent in all variations of temperatures and geometry for the location of the ventilation systems will be compared and then the effects and aftermath within the climatic conditions will be evaluated. Keywords: broiler, Fluent, temperature, ventilation. Introduction Poultry housing technology, external climatic conditions and the weather influence the indoor microclimate during different periods of the year. It requires different methods of ventilation control [1; 2]. Creation of internal environment in the halls for poultry housing is complicated mainly because of the high biological load of indoor environment, resulting from the large number of chickens per 1 m 2 of the floor area. Problems occur particularly towards the end of fattening. Chickens have a large mass; they produce large quantities of pollutants [2; 3]. Usually this problem is solved by intensive ventilation [4; 5], but it has a rather negative influence also on the technical equipment [6]. The target temperature best for broilers during their growth varies and depends on the size of the chicken and other factors. This is usually around 30 ºC, the lowest temperature on the first days is nearly 20 ºC or less at the time of slaughter [7]. Therefore, ventilation must be adjusted by the corresponding method to maintain the optimal temperature. The perceived temperature by the chicken depends on humidity. If the relative humidity is out of the ideal range of 60 to 70 %, the temperature within the hall needs to be adjusted. For example, if RH is near 50 %, the temperature has to be increased to 33 ºC on the first day[8]. In all stages of growth of the chicken we have to observe and ensure that chickens perceive appropriate temperature [9]. Ventilation is the only practical way to reduce very high humidity, which is the most common problem in winter and it can affect the health of the chicken. Even when ventilation is not necessary used to remove heat, it can be maintained at minimum level to prevent wetting, hardening, bedding and problems with ammonia [10]. While breathing, chickens receive oxygen from the air and exhale carbon dioxide. Therefore, it is necessary to supply fresh air to exchange oxygen and remove the excess of carbon dioxide. Ventilation is necessary to provide fresh air during the year in warm and cold weather. The most common problem of the air quality is ammonia, which is caused by the very wet bedding. This causes health problems. Correct ventilation prevents the accumulation of ammonia by controlling the relative humidity [11]. The Fluent CFD software is used as a universal tool for numerical analysis of fluid flow and thermal analysis. The influence of the geometrical shape and the velocity field on the thermal field was also monitored.effective distribution of fresh air inside the building and the corresponding locations of inlets and exhaust outlets contribute to the effectiveness of the ventilation components. The thermal analysis also dealt with extreme temperature conditions inside the interior during a partial and complete failure of the ventilation system and leads to evaluation of the effect and consequences of indoor microclimatic conditions [12]. DOI: 10.22616/ERDev2017.16.N091 461

Materials and methods This research work and measurements were carried out in a building for fattening of broilers. The poultry house has internal dimensions: length 100 m, width 11.5 m, height 2.7 m, and the inside hall is housing 23,000 chickens on the floor. The measurements were carried out during the 26 th to 33 rd days of fattening when the chicken have average weight about 1.5 kg. Fig. 1. 3D modeling of the experimental hall 4 1 2 3 Fig. 2. Computational mesh and boundary condition zones: 1 exhaust fan; 2 window; 3 slice volume; 4 computational domain Fig. 1 shows the actual shape of the hall that is simulated by graphic software CATIA with the structure and size equivalent to the fact. Because the ceiling of the hall has a flat shape, the space of the hall can be considered a cube. Input data for the program Fluent have to be made of the surface and closed space, therefore, the inside space was split with the corresponding position of the windows and fans. Beside graphical data, we should add more data to the program, e.g., the temperature outside, humidity of the air, the thermal conductivity of the wall, the heat production of chickens (can be considered as the exothermic of the floor). Fluent CFD software was used as a computational tool to obtain the numerical solution of the flow, temperature and concentration profiles corresponding with the measurement. Two sets of boundary conditions were prepared to illustrate the difference between the transversal and longitudinal ventilation, mainly with respect to maximal values of velocities, temperatures and pollutant concentrations. Fig.2 shows the simplified shape of the computational domain. It can be seen, that it is a pure geometrical block with rectangular windows on the right side and circular fans on the opposite left side. The most important simplification relative to the actual state is the usage of the 0.2 m tall Slice volume, which is the zone, where animals move and produce heat and pollutants. The main reason for using this auxiliary volume is a possibility to include heat and mass sources to the volume in values per cubic meter. This attempt is closer to the reality than using only the surface source (values per square meter). For example: usage of the heat surface source from the floor representing the 462

amount of the heat flow produced by animals leads to unreal overheating of the floor and therefore it cannot be recommended for this kind of problems. Results and discussions Calculation of the required air flow: where m vmax doses of ventilation air for 1 animal, kg s -1 pcs -1 ; m z weight of one animal, kg pcs -1 ; b, d constants determined for each piece from the table. where M vmax total air flow, kg s -1 ; Z quantity of animals, pcs. where V a volumetric air flow, m 3 h -1 ; ρ density of air, kg m -3. m vmax = b m zd 10-3, (1) M vmax = Z m vmax, (2) M vmax V a =, (3) ρ With the capacity of the large fan 0.75 kw or 24,929 m 3 h -1 and of the small fan 0.33 kw or 7,024 m 3 h -1, we can choose the quantity of the fans to activate. Table 1 Parameters and number of required fans used according to calculation results States of chickens Volumetric air Quantity -1 flow, m 3 h of large fans, pcs Quantity of small fans, pcs 26 th day of fattening m z = 1.5 kg pcs -1 172,040 5 2 35 th day of fattening m z = 2.1 kg pcs -1 214,140 7 6 Total fans in the hall 230,000 7 8 The input data for the CFD program: Construction data; Outside temperature: t = 21.6 ºC; Outside concentration CO 2 : 0.04 % = 400 ppm; Production of CO 2 on the floor: 0.065g s -1 m -3 ; Production heat of chickens: Q c = 74.6 W m -2 ; Heat transfer coefficient through the composite wall and ceiling: k = 0.773 W K -1 m -2. The presented results arise directly from the measured values and the total flow rate is the same for both basic configurations. Basic result visualization can be seen in Fig. 3 as mass concentration of ammonia in case of transversal ventilation and in Fig.4 it compares the velocity profile of the longitudinal and transversal ventilation. The overall flow rate is the same for both variants and it leads to clear consequence, that for the smaller cross section area during the longitudinal ventilation the velocities are higher than during the transversal one. It is clearly seen, that the flow during the transversal ventilation is very fluctuating, with the repeating velocity pattern shapes corresponding to the position of the windows and fans. It has to be said that the pattern shown here is the only one of a lot of possibilities obtained as a steady state solution. Nature of the flow is in this case given by the considerable number of inputs and outputs and it is understood that in actual case the pattern can make time dependent changes in the shape of particular air streams. The longitudinal ventilation leads to smooth flow with steady velocity profile. 463

Fig. 3. Mass fraction of NH 3 in case of transversal ventilation Max 1 3 2 Min Fig. 4. Comparison of flow pattern for transversal and longitudinal ventilation: 1 transversal ventilation: min = 0 m s -1, max = 1.6 m s -1 ; 2 longitudinal ventilation: min = 2 m s -1, max = 2.7 m s -1 ; 3 level of velocity The more accurate view into the results of CFD can be done by visualization of the results in form of graphs. Fig. 5 shows the comparison of transversal and longitudinal ventilation at the same profile, which is defined as a central axis of the stable at the height 0.5 m above the floor. It can be seen that in the case of transversal ventilation the existence of poorly ventilated areas at the front and the end of the broiler house exists, because the concentration of pollutants rapidly grows. The longitudinal ventilation makes the ventilation more uniform, but the animals at the end of the hall are permanently at higher concentration of pollutants in comparison with those, who live in the front of the stable. The dust concentration was measured, but the models which were tried to use and solve in Fluent for the presented flow conditions lead to results with completely nonsense values of concentration and dust distributions. The Fluent mixture model was used [13], but it was not practically possible to archive the convocation to measured values in the stationary state in such large geometry. Therefore, the dust simulation is not presented here and will be tested at smaller models to obtain a functional methodology at first and will be the subject of the forthcoming research. 464

Fig. 5. Comparison of temperature and CO 2 mass fraction in central axis of the stable at the height 0.5 m above the floor Conclusions 1. It is possible to calculate the necessary flow of air for chickens in several age and weight categories and check the suitable fans for effective ventilation rate. 2. The longitudinal ventilation makes more uniform temperature and concentration of CO 2, and more efficient convective cooling effect during hot summer ventilation, but at the end of the hall, concentration of pollutants is always higher than at the front of the hall. 3. Computer fluid dynamic as a simulation tool can bring obvious and clear benefit because of the possibility to compare the variants of the solution including ventilation defects and failures. From this point of view, it can be very helpful for increasing the quality of ventilation control and regulation. 4. It is possible to continue to use CFD to simulate in the winter conditions when outdoor temperatures are low and inside the hall heating systems for habitat are used or it can be used for more complex and more difficult cases. 465

Acknowledgement Access to computing and storage facilities owned by parties and projects contributing to the National Grid Infrastructure MetaCentrum provided under the program Projects of Large Research, Development, and Innovations Infrastructures (CESNET LM2015042), is greatly appreciated. References 1. Kic P., Hubený, M., Ledvinka Z., Tůmová E., Campos C.G., Martínez C.T. Control of indoor environment in housing of laying hens. Proceedings of International conference Trends in Agricultural Engineering, 2007, CULS, Prague, pp. 212-214. 2. Kic P., Růžek L., Ledvinka Z., Zita L., Gardiánová I. Pollution of indoor environment in poultry housing. Proceedings of International conference 11th International Scientific Conference Engineering for Rural Development, Latvia University of Agriculture, 2012, Jelgava, pp. 480-483. 3. Aarnink A.J.A., Van Harn J., Winkel A., De Buisonje F.E., Van Hattum T.G., Ogink N.W.M. Spraying rapeseed oil reduces dust in poultry houses. Proceedings of International conference Precision Livestock Farming 2009, 4th European Conference on Precision Livestock Farming, ECPLF, 2009, Elsevier, Wageningen, pp. 73-79. 4. Šottník J. Principles and experience of heat stress reduction in buildings for housing of animals. Proceedings of International conference Trends in Agricultural Engineering, 2007, CULS, Prague, pp. 441-446. 5. Zajíček M., Kic P. Longitudinal ventilation of broiler house simulation of variants. Proceedings of International conference 12th International Scientific Conference Engineering for Rural Development, 2013, Latvia University of Agriculture, Jelgava, pp. 198-202. 6. Kic P., Kalvoda M., Zavadil V. Energy savings byheat recovery in ventilation. Proceedings of International conference Trends in Agricultural Engineering, 2007, CULS, Prague, pp. 215-218. 7. Henriksen S., Bilde T., Riber A.B. Effects of post-hatch brooding temperature on broiler behavior, welfware, and growth. Poultry Science, Volume 95, Issue 10, 1 October 2016, pp. 2235-2243. 8. De Basilio V., Requena F., Leon A., Velazco Z., Picard M. Does early thermal conditioning sometimes fail to improve the resistance of broilers to heat stress? Animal Research, Volume 51, Issue 5, 2002, pp. 407-420. 9. Said, J., Bod'o, S., Saady, T., Galik, R., Sardary, S., Abbas, K. Effect of broler chickens loving conditions on results of fattening. Agronomy Research,Volume 14, Issue 1, 2016, pp. 228-235. 10. Purswell J.L., Dozier III W.A., Olanrewaju H.A., Davis J.D., Xin H., Gates R.S. Effect of temperature-humidity index on live performance in broiler chickens grown from 49 to 63 days of age. Proceedings of International conference 9th International Livestock Environment Symposium, 2012, Valencia, Spain, 8 July 2012 through 12 July 2012,code 97164,pp. 41-49. 11. Liu W., Cheng P., Wang Z., Ma W. Effect of rice peptides on the performance, health condition of broler and ammonia concentration in henhouse. Journal of the Chinese Cereals and Oils Association,Volume 28, Issue 12, December 2013, pp. 82-85. 12. Zajíček M., Kic P. Simulation of the broiler house ventilation. Scientia agriculturae bohemica, vol. 44(1), 2013, pp. 32-37. 13. The limitations apply to the mixture model in Fluent. [online][20.03.2017] Available at: https://www.sharcnet.ca/software/fluent6/html/ug/node891.htm 466