KEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime

Similar documents
SpectraSensors SS500 Mid-Sensitivity Moisture Analyzer

Using the PPM2 Portable Trace Moisture Transmitter

VERIS Accelabar. Superior Flow Measurement Accuracy

Sho-Rate TM Models 1250 & 1255

Aurora TDLAS analyzers for Hydrogen Recycle Applications

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Condumax II Hydrocarbon Dew-Point Analyzer

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

The Proper Mechanism for Field Validating Moisture Analyzers. GE Measurement & Sensing GE Oil & Gas

DETECTION AND DETERMINATION OF H 2 S AND TOTAL SULFUR IN NATURAL GAS Marshall T. Schreve Del Mar Scientific, LTD.

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Multiphase Flow Measurement. Multiphase Flow Meter Wet Gas Meter Multiphase Wet Gas Flow Meter Well Testing Service

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Compact flue gas analyser: testo 300 M-I

Process Total Organic Carbon Analyzer

Del-Monox Breathing Air Purifiers DM Series

MOLECULAR GATE TECHNOLOGY FOR (SMALLER SCALE) LNG PRETREATMENT

GAS 3050P NDIR FLUE GAS

PRODUCT CONFORMITY CERTIFICATE

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Elcometer 135C. Bresle Test Patch NEW. Determines the level of soluble salts on uncoated surfaces using the patch method in accordance with ISO

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

ProFoss for in-line process analysis of dairy powder

PORTABLE HARDNESS TESTING

TARGAS-1. Portable Photosynthesis System. Photosynthesis Soil Respiration Canopy Assimilation Environmental Monitoring

Chloride/Sulfate Analyzer

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

PARTICULATE CONCENTRATION AND AIR QUALITY MONITORING IN ONE ADVANCED INSTRUMENT

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide

WLC60 Heavy Duty LED Light

TSI Model 3063 Thermal Mass Flowmeter

The Culligan Hi-Flo 50 Series Industrial Water Filter System

TWIN LASER PARTICLE COUNTER

Controls and Software CHORE-TRONICS 2 Controls

Model BF 260 Incubators Avantgarde.Line with forced convection

Humidity/temperature measuring instrument

Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E

MATERIALS OF CONSTRUCTION

Controls and Software CHORE-TRONICS 2 Controls

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

4690 Series Turbidity systems. Accurate, reliable turbidity measurement

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control

Model BF 720 Incubators Avantgarde.Line with forced convection

pressure regulators Back Pressure Regulators

PROCESS MOISTURE ANALYZERS Measuring moisture in gas or HC liquids in hazardous areas

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Red Eye Multiphase Water-Cut Meter

REFERENCE MEASURING INSTRUMENT

???? Spot Check Measurement Simple, accurate, reliable

Cleaning Validation PRODUCT OVERVIEW

Hydrogen Generators Flow Capacities up to 500 cc/min

Bruker Elemental S1 SORTER

Models 1350G & 1355G. Low Flow Glass Tube Flowmeters. Ships in 5 days. Overview. Product Features. Variable Area

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

PORTABLE FLUE GAS ANALYZER

For highest levels of purity

Portable Emissions Measurement System (PEMS) for nanoparticle counting and classification.

PRISM PA nitrogen membrane separators... tell me more

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

FLUXUS F/G601 and F/G608

Fpollutant-free zero air for analytical

12 Temperature measurement SCT analogue

Optica. GE Sensing. The Next Generation Humidity Reference Standard. Optica Measures

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

PRODUCT CONFORMITY CERTIFICATE

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Industrial Weights. Solid and Innovative Design To Meet Tough Requirements

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership

High Precision Gauge Pressure Indicators

CROSBY H-SERIES DIRECT SPRING SAFETY VALVES

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

ARC STUD WELDING SYSTEMS

Data Loggers (Deep) Water Conditions

AM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide

The most energy efficient compressed air filters in the world.

Flygt 3057, 50Hz. Technical Specification

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

Industrial Drum Transfer Pumps

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

STEAM QUALITY TEST KIT SQ1

NeuStream -EOR. Supplying Field Deployable Systems for CO 2 and Power Generation for the Enhanced Oil Recovery Market

Compressed Air Filters Sample Filters

AM1730 Secondary Reference Platinum Resistance Thermometer User s Guide

Specifying A Moisture Analyser

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

RPM Rotary Gas Meters

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

Product Inspection. Compliance Expertise Performance Uptime. Product Inspection Services Maximizing Productivity

ProODO Optical Dissolved Oxygen Meter for the Lab or Field SPECIFICATIONS

PROCESS. Process Analysers For Gas and Liquid Phase

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

Transcription:

KEy FEATuRES Virtually maintenance free No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime measurements No wet-up or dry-down delays Short term payback; no consumables NIST-traceable calibration Ask about other available products: SS1000 Portable Gas Analyzer SpectraSensors SS1000 Portable is a light weight, easy to handle, battery-powered H2O or CO2 analyzer, used to verify measurements and for spot-checking when other methods provide questionable results. In natural gas pipeline applications, poor quality measurement results are extremely costly. Additional processing or dehydration costs, upset conditions, shut-ins and inconsistent process results may be caused by sensors that do not perform properly. The SS1000 reveals poorly performing sensors, pinpoints high moisture and can be used as a standard for measurement validation. RAPID RESPONSE TIME The SS1000 allows for fast, simple operation. The analyzer s laser and detector take measurements 4 times per second and average the results. These real-time measurements are not hampered by wet-up (absorption) or dry-down (desorption) as with surfaced-based sensors. reliability and speed are ultimately critical in process measurements, especially with a portable unit. The SS Series Sensors are the fastest, most dependable method to get an accurate moisture measurement. RELIABLE Using state-of-the-art laser technology developed by NASA, the SS1000 analyzer is more reliable, with greater repeatability than surface based sensors and is not subject to the interpretation errors of a chilled mirror. NO INTERFERENCE As with all SpectraSensors analyzers, the SS1000 combines a patented laser with control electronics and smart software. The analyzer s sensor heads are not subjected to corrosives or contaminants in the gas because the sensor is isolated from the sample gas stream. The result is an analyzer which does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans. PAYBACK The SS1000 very quickly pays for itself eliminating the cost of consumables, extra sensor heads, factory calibrations and labor and overhead associated with excessive maintenance. Expensive problems caused by unreliable gas measurements such as added processing steps and poor gas quality can be eliminated SS2000 Gas Analyzer with Sample Conditioning Panel SpectraSensors, Inc. 4333 W Sam Houston Pkwy N Ste 100 Houston, TX 77043 Tel: 800 619 2861 Fax: 713 466 3172 spectrasensors.com Supplied by: IMA Ltd, Parkwell House, Otley Road, Guiseley, West Yorkshire, LS20 8BH, England Tel: +44(0)1943 878877 Email: info@ima.co.uk Website: www.ima.co.uk

CLASS IIIb LASER PRODUCT SS1000 Portable Gas Analyzer SPECIFICATIONS Performance Standard Optional Moisture Concentration (H2O)* nist-traceable 0-20 lbs/mmscf natural Gas 0-422 ppmv 0-20 lbs/mmscf natural Gas 0-422 ppmv lower Detection limit (H2O) 2 lbs/mmscf (42 ppmv) 0.5 lbs/mmscf (11 ppmv) repeatability (H2O) ±1% of reading or ±10 ppmv, ±1% of reading or ±4 ppmv whichever is greater (ranges up to 10,000 ppmv available) Carbon Dioxide Concentration (CO2)* 0-10% repeatability (CO2) ±1% of reading, or ±0.04% (400 ppmv), whichever is greater response time** Display updates 0.25-2 seconds (software adjustable) Application Data environmental Temperature range* -20º to 50º C (-4º to 122º F) Sample Inlet Pressure 10 to 25 PSIA, 10 PSIG maximum (70-170 kpa Abs, 70 kpag maximum) Sample Flow rate 0.1-10 l/min (0.2 to 20 scfh) Contaminant Sensitivity none for gas phase glycol, methanol, amines, hydrogen sulfides or mercaptans. Electrical & Communications Input Voltage electrical Storage Current Outputs lcd Display 100-240 VAC, 50-60 Hz standard 12-Volt, Sealed lead-acid battery Approx. 8 hours usage time per charge 0.5 A @ 120 VAC during recharging rs232 all parameters Concentration, Cell Pressure and Cell Temperature Physical Dimensions (Includes Handle and Feet) nominal 200 mm H 175 mm W 450 mm D (8 H x 7 W x 18 D) Weight approx. 6.8 Kg (15 lbs) Sample Cell Construction 316l Series polished stainless steel standard Accessories Membrane Separator, Carrying Case, Charger, Quick Connect Fittings included. Sample Conditioning available. Area Classification Certification non-hazardous (certified) locations General Purpose * ** Consult factory for alternative or extended ranges. Flow rate Dependant - Sample cell volume is 0.14 l (0.005 ft3). Time to displace cell volume at a flow of 1 l/min 2 scfh) is ~10 sec. www.spectrasensors.com DS SS1000 ng 10006 en 02 4333 W Sam Houston Pkwy n Ste 100 Houston, TX 77043-1223 Tel: +1 713 466-3172 Fax: +1 713 856-6623 11027 Arrow route rancho Cucamonga, CA 91730-4866 Tel: +1 909 948-4100 Fax: +1 909 948-4142 LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM 10 mw MAX CW 800-3000 nm

H 2 O / CO 2 in Natural Gas Analyzer Price List Portable SS1000 Analyzer Solution Product Codes 10401, 10501, 10603 Effective: January 1st, 2009 Portable Natural Gas Analyzer with carrying case and 100/250 VAC, 50/60 Hz charger (Suitable for use in non-hazardous areas) SS1000- Measured Component 0 1 2 4 8 X 5 1 1 1 1 H2O range 2-20 lbs/mmscf (42-420 ppmv), Accuracy ± 0.5 lbs/mmscf H2O range 0.5-20 lbs/mmscf (10-420 ppmv), Accuracy ± 0.2 lbs/mmscf CO2 range 0-10% H2O range 0-100 ppmv H2O range 0-6000 ppmv Other Probe-Regulator Assembly - removes liquid and reduces pressure; 0-10 psig output pressure Probe Length 4 7 9 Housing 0 1 2 SC401-1 1 1 4" Probe (typically suitable for 4" to 8" line diameter) 7" Probe (typically suitable for 8" to 16" line diameter) 9" Probe (typically suitable for 12" to 24" line diameter) No housing 3/4" NPT, up to 2000 psig 1" NPT, up to 3500 psig Portable Heated Regulator Assembly - 0-10 psig output pressure; 85 F, 50 ft cable length Power Supply 5 110 VAC 6 220 VAC SC403-1 1 1 1 SpectraSensors, Inc 4333 W Sam Houston Pkwy N, Suite 100 Houston, TX 77043-1223 www.spectrasensors.com PL 10075 EN 01

H 2 O / CO 2 in Natural Gas Analyzer Portable SS1000 Analyzer Solution Product Codes 10401, 10501, 10603 Typical Accessories P/N 02199-00001 Spares Kit- includes fuses, o-rings and hardware $79 P/N 00000-02015 Extended calibration range (up to 100lb/MMSCF H2O) $500 Other ranges available (consult factory) P/N 39901-12012 Replacement battery charger $150 P/N 01902-93001 Instruction Manuals (up to 2 copies at no charge) $30 each P/N 00403-90001 Quick-connect flow meter $300 Replacement mating quick-connect fittings (1 ea. input and output) $125 P/N 01910-30017 Stainless Steel Tag, up to 2 lines of text $45 P/N 00000-02014 Certified As-Built Drawings $50 2 sets Supplied by: IMA Ltd, Parkwell House, Otley Road, Guiseley, West Yorkshire, LS20 8BH, England Tel: +44(0)1943 878877 Email: info@ima.co.uk Website: www.ima.co.uk