Gerald Desmond Bridge Replacement

Similar documents
1. Unified Facilities Criteria - Design: General Building Requirements (UFC ).

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)

TENANT CRITERIA MANUAL INSERT PHOTO HERE

DESIGN AND CONSTRUCTION STANDARDS. Section 2: Standards for Specific Categories of Work. Laboratory Standards

Bureau of Indian Affairs

Budget Estimate Basic Tenant Improvement

Universal Design Standards

Spatial Needs Assessment

THE RESTORE LOUISIANA REIMBURSEMENT ESTIMATE

Property Offering. Cold Storage Warehouse 4501 Hitch Peters Road Evansville, IN 47711

MODULAR BUILDING SPECIFICATIONS

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

FACILITIES MAINTENANCE WORKER

COLUMN SPACING TRUCK ACCESS/DOORS EAVE HEIGHT UTILITIES PARKING & DRIVES

Qualifying Process for Handyman Online Qualifying Questions. Name: Street Address: City: State: Zip Code. Home Phone: Cell Phone: Address:

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

A/E Design Deliverable Checklist

Total Building Area: 1964 Construction 30,140 square feet 1976 Construction 36,787 square feet 66,927 square feet

Typical Finished Basement Details

COOLIDGE SENIOR HIGH SCHOOL

CONSTRUCTION TRADES LABORATORY September 30, 2010

The Ultimate Home Value with Quality,

New Homes Starting at $124,900

Seal Harbor Development 1 Nagog Park Acton, MA 01720

Facility Assessment Report, Montgomery Independent School District

New Homes Forestbrook Road. Yes, it s INCLUDED!

Science Education Facilities

Features & Amenities. EXTERIOR FINISHES COMMUNITY FEATURES

Seasons Business Center New Construction!

CHARTRES COURT Washington Avenue Houston, Texas ChartresCourtHouston.com CHARTRES COURT LLC

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS


EVENT 29: November 15, 2017 THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

TEXAS FACILITIES COMMISSION Edit Date: 4/13/2012

TERMINAL BUILDING EVALUATION

General Conditions 39,522 5, ,292 26,050 75,921 1, Labor hours

3D Home Improvement and Inspection Services, Inc

Manufacturing Facilities Proposal

ELEMENTARY SCHOOL EDUCATION SPECIFICATIONS

Division 09 FINISHES TABLE OF CONTENTS

Fairfax County, Virginia

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI.

LASALLE - BACKUS EDUCATION CAMPUS

standard features Power Exhaust Fans w/light - Both Baths GFCI Receptacles Upgrade Light Fixture - Bath 1 Vanity - Per Lav GFCI Receptacles

Attachment 3 Statement of Work Statement PROJECT NUMBER MA DIRECTORATE OF PUBLIC WORKS FORT BRAGG, NORTH CAROLINA

Category Minimum Standards Recommended Standards

The facility is approximately 439,350 square feet, located on a acre parcel on Wood Dale Road in Wood Dale, Illinois. 439,350 Square Feet

INTERIOR ENVIRONMENT

Highland Park. Exceptional Interiors (cont.) Green Technology. Designer Kitchen Features. Distinctive Exterior Features

LEVEL TWO NUMBERS AND TITLES. Introductory Information. Bidding Requirements. Contracting Requirements. Facilities and Spaces. Systems and Assemblies

Sample Home Inspection

Tomahawk Dome Silent Auction Items

Element Z General Design Requirements Room Standards

A/E Design Deliverable Checklist

Property Condition Assessment

Davis Frame Co., Inc. Construction Budget Considerations

Communications Page 1 of 9

Inspection Report. 1 of 8

The parking lot is in varying condition depending upon location. The vehicular and pedestrian traffic flow is generally good.

Kitchen Remodel Estimator. Contact Info: Project Summary: Design. Demo

HISTORIC PLAN, FLOOR PLANS, AERIAL PHOTOS

Velma F Thomas Early Childhood Center

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS

John T Pirie Fine Arts & Academic Center ES 650 E 85th St Chicago, IL 60619

Pembridge The Country Club Collection TOWNHOMES AT CRYSTAL SPRINGS

PATTAYA POSH. A chance to own the best location in North Pattaya. North Pattaya Road, Pattaya, Thailand

COLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444

ARCHITECTURAL EXPANSION JOINT PRE-INSTALLATION INSPECTION

Delta Zeta Sorority House Renovation Scope of Work

HOMES FOR SALE. Under Construction. Quality Stick Built Starting at $278,000. Watford City North Dakota WATFORDCITYREALESTATE.

Estimate Form for Bathroom Design and Installation

Section BUILDINGS, SHELTERS, ENCLOSURES

CENTRAL GREAT PLAINS SERIES

FLOORPLAN /ELEVATION SQ.FT. BDRM BATHS GARAGE BASE PRICE

INTERIOR ENVIRONMENT

11/1/2016. Smoke detectors will be furnished by MHA and installed by contractor.

Paul Laurence Dunbar Career Academy High School 3000 S King Dr Chicago, IL 60616

HURON PUBLIC WORKS BUILDING HURON, SOUTH DAKOTA BID NO R

Kelly Village Apartments 3118 Green Houston, Texas 77020

Wellington Manor Series

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

e a s t 2303 Dulles Station Blvd., Herndon, VA BASE BUILDING SPECS

Section 03 SPACE AND SITE DESIGN TABLE OF CONTENTS

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

ADDENDUM NO. TWO TO THE REQUEST FOR PROPOSAL (RFP) DOCUMENTS April 25, 2016

Telecommunication Spaces

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

DRAFT. Baker Center Special Campus Site Summary 64,153 SF. Introduction

OFFICE OF EDUCATIONAL FACILITIES FLORIDA BUILDING CODE SECTION 423 APPLICATION MATRIX

Homes at Pine Ridge - NEW CONSTRUCTION SPECS

EDISON. One Story, 3 Bedrooms, 2 Baths, Den & 2 Car Garage ELEVATION C ELEVATION D DRHORTON.COM. artist s concept.

School Without Walls

Facilities Condition Assessment Qualcomm Stadium

Timber Trail Plan LOT BEDROOMS 4.5 BATHROOMS 2,974 FT 2 Land/Home Package OFFERED BY: SUNRIVER REALTY LINDA DORR, BROKER

PROFESSIONAL DESIGN MANUAL INDEX

Construction Summary

PeachStone Capital, Inc. Atlanta s Hard Money Lender When timing is everything, we close! Hard Money Loan Property Worksheet Checklist

a D.R. Horton Company

Transcription:

Item # Room # icip. # of Occupants 101 12 Conference / Crew Room 1 400 400 Supervisor Offices Conference and secondary training room for up to 12 people Flooring: VCT Electrical Type: rmal (utility power) Wall Base: 4" rubber Electrical Outlets: (1) duplex on 4 walls Ceiling: Suspended Acoustical Tile (SAT) Other Walls: Gypsum Board, paint High sound attenuation 8 (lan) 1 1 1 lan for connection to ceiling projector 2'x4' fluorescent fixtures recesssed in SAT. Deep cell parabolic with T-8 lamps, electronic ballast. 50 fc Fluorescent downlights on dimmers 7/16/10 1 of 15

105 0 Shipping & Receiving 1 80 80 At entrance. Garage/Shop Receipt of Parcel Service & Truck Deliveries Flooring: Sealed concrete. Electrical Type: rmal (utility power) Wall Base: 4" rubber Electrical Outlets: (2) convenience duplex Ceiling: Suspended Acoustical Tile (SAT) Walls: Gypsum board, paint Countertop 1 1 0 1 2'x4' fluorescent fixtures recesssed in SAT. Deep cell parabolic with T-8 lamps, electronic ballast. 50 fc 7/16/10 2 of 15

102, 103 2 Office 2 120 240 Central area - near conference room. Supervisor 1 Supervisor 2 ne Flooring: VCT Electrical Type: rmal (utility power) Wall Base: 4" rubber Electrical Outlets: 1 duplex on each walls Ceiling: Suspended Acoustical Tile (SAT) Walls: Paint 2 (lan) 1 1 computer 1 2'x4' fluorescent fixtures recesssed in SAT. Deep cell parabolic with T-8 lamps, electronic ballast. 50 fc w/ task lighting High sound attenuation Interior relite to Maintainer's Room Lockset on door. 7/16/10 3 of 15

107 Kitchen 1 130 130 Central to all areas. Coffee maker. Single compartment sink and faucet assembly. Flooring: Vinyl Composite Tile (VCT) Electrical Type: rmal (utility power) Wall Base: 4" rubber Electrical Outlets: (1) duplex on each wall (1) outlet for each piece of equipment Ceiling: Suspended Acoustical Tile (SAT) (1) gfi @ sink area Walls: Gypsum board, paint Other (1) microwave, (1) coffee maker, (1) refrigerator Upper and lower cabinets with ADA accessible sink. Plastic laminate finish. B&B supervisor to enter timecards. Bulletin board(s) - safety, union, foremen notices. Tables and chairs. Appliances? Microwave and refrigerator? Coffee maker High sound attenuation 2'x4' fluorescent fixtures recesssed in SAT. Deep cell parabolic with T-8 lamps, electronic ballast. 75 fc @ counter 40 fc general illumination 7/16/10 4 of 15

108 10 Men's Restroom/Locker 1 430 430 Near break room. Exhaust fan Shall be ADA compliant. Lavatory (1) Watercloset (1). Urinals (1). Shower (2) Counts will be determined by occupant load factor. Flooring: Ceramic tile or sealed concrete Electrical Type: rmal (utility power) Wall Base: Ceramic tile or rubber, 6" high Electrical Outlets: (1) convenience duplex and (1) GFI at sink area. Ceiling: Gypsum board Walls: Fiberglass Reinforced Plastic Board (FRP) to 4' high, epoxy paint above. Water and impact resistant gypsum board. Changeable room signage for "in use" management. Wall mount fixtures. 10 Full size lockers (18"Wx18"Dx72"H) including ADA compliant 20 fc Benches Toilet partitions and accessories High sound attenuation 7/16/10 5 of 15

109 5 Womens Restroom/Locker 1 250 250 Near breakroom. Exhaust fan Shall be ADA compliant. Lavatory (1). Watercloset (1). Shower (1). Flooring: Ceramic tile or sealed concrete Electrical Type: rmal (utility power) Wall Base: Ceramic tile or rubber, 6" high Electrical Outlets: (1) convenience duplex and (1) GFI at sink area. Ceiling: Gypsum board Walls: Fiberglass Reinforced Plastic Board (FRP) to 4' high, epoxy paint above. Water and impact resistant gypsum board. Changeable room signage for "in use" management. Wall mount fixtures. 5 Full size lockers (18"Wx18"Dx72"H) including ADA compliant 20 fc Bench Toilet partitions and accessories High sound attenuation Privacy lock. 7/16/10 6 of 15

110 Janitor's Closet 1 40 40 Near locker/restrooms. Exhaust fan Hooks for hanging tools and equipment. Shelves for storage of equipment and supplies. Mop sink (1) Floor drain (2) piped to clarifier Flooring: Ceramic tile or sealed concrete Electrical Type: rmal (utility power) Wall Base: Ceramic tile or rubber, 6" high Electrical Outlets: (1) convenience duplex and (1) GFI at sink area. Ceiling: Gypsum board Walls: Fiberglass Reinforced Plastic Board (FRP) to 4' high, exopy paint above. Water and impact resistant gypsum board. 2x4 flourescent fixture surface mounted to gypsum board ceiling. 20 fc Sound insulation in walls 7/16/10 7 of 15

Existing width Existing length 111 1 Room Quantity Net SF Req'd Shop 1 400 Could be on same mechanical zone as Telecom Room Maintenance and fabrication of parts and equipment. Consider separate zoning Need to maintain 70 degree @ 24/7 Provide 2 floor drains connected to clarifier. Ventilation/ dust control Flooring: Sealed concrete Electrical Type: rmal (utility power), Emergency Wall Base: 4" rubber Ceiling Height: min. 10'-0" Electrical Outlets: Separate subpanel 100A 240V w (2) 40A breakers Electrical Outlets: Separate subpanel 100A 240V Ceiling: Suspended Acoustical Tile (SAT) Shop equipment? Walls: Paint N/A Other Cable tray Locked 2'x4' fluorescent fixtures recesssed in SAT. Deep cell parabolic with T-8 lamps, electronic ballast. 50 fc Lockset on door. 7/16/10 8 of 15

112 1 Shop Toilet 1 50 50 Shop Garage/ Warehouse Exhaust fan Restroom Lavatory (1). Watercloset (1). Flooring: Sealed concrete Electrical Type: rmal (utility power) Wall Base: Rubber, 6" high Electrical Outlets: (1) convenience duplex and (1) GFI at sink area. Ceiling: Gypsum board Walls: Fiberglass Reinforced Plastic Board (FRP) to 4' high, exopy paint above. Water and impact resistant gypsum board. ADA compliant toilet and sink. Wall mount fixtures. 20 fc High sound attenuation Privacy lock. 7/16/10 9 of 15

115 0 Electrical/ Telecom Room 1 80 80 Could be on same mechanical zone as Shop Entrance for systems from exterior radio tower. Consider separate zoning Need to maintain 70 degree @ 24/7 ne Flooring: Sealed concrete. Electrical Type: (1) 30 Amp, 120 V Wall Base: 4" rubber Electrical Outlets: (2) quads, 1 @ 7ft on wall w/ boards Separate Ground Block on wall w/ boards Ceiling: Exposed structure - no finished ceiling Emergency Power Generator, BNSF UPS Walls: Gypsum board, paint Phone back boards (3) 4 x 8 fire treated plywood 0 0 0 0 Blockout in Ext Wall 22in (w) x 12in (h) Wave Guide (Microwave coax) 1'x4' fluorescent fixtures hung from structure. T-8 lamps, electronic ballast. 50 fc Lockset on door. 7/16/10 10 of 15

114 0 Storage 1 80 80 Garage/ Warehouse Exhaust fan Storage for tools, parts and supplies. ne Flooring: Sealed concrete. Electrical Type: rmal (utility power) Wall Base: 4" rubber Electrical Outlets: 1 duplex on 1 wall @ dr. Ceiling Height: min. 10'-0" Ceiling: Exposed structure - no finished ceiling Walls: Gypsum Board, paint 24" w shelf units, 24" vertical spacing, max capacity 1'x4' fluorescent fixtures hung from structure. T-8 lamps, electronic ballast. 30 fc Lockset on door. 7/16/10 11 of 15

113 4 Garage/ Warehouse 1 4,200 4,200 Space to be on lower level with vehicle access through main garage doors. Movement of equipment to the storage using 4 ton crane mounted to the ceiling structure. Garage for housing UBIT and other trucks. Maintenance for vehicles and equipment. Flooring: Sealed concrete Wall Base: 4" rubber Ceiling Height: min. 22'-0" (to accommodate overhead crane) Ceiling: Open to structure Walls: Hard Surface to 4' AFF. Paint Workbench area required - 20' long. Provide on one side of garage with "safety" zone around bench area. Equipment (1) four ton capacity bridge crane Need 16' high overhead doors. Drive thru not required. Provide vision panels in sectional overhead doors. Provide man doors per preliminary plan Roof top exhaust fans Locksets on doors. Radiant heaters Exhaust fans, evaporative cooler (one per bay) Provide 3 floor drains connected to clarifier. Provide (1) work sink - standup laundry sink and (1) emergency eyewash station and shower. (3) compressed air outlets from compressor (4) lube lines from drums / compressor to lube reels, water line and waste oil pick-up Electrical Type: 120v/30amp; 220 for air compressor Electrical Outlets: Plug molding along bench areas. Provide cable reels in 3 locations. Overhead doors to be powered. Door operator disconnects (1) Four ton industrial crane to facilitate the movement of equipmen from the storage area to the open area for loading and unloading. 1 lan 1 at bench area 1 computer 1 General lighting in high bay attached to structure. T-8 lamps, electronic ballast. 50 fc. Provide small task lights at bench areas. 7/16/10 12 of 15

M02 1 Inventory Room 1 1,800 1,800 Shipping & Receiving Garage/ Warehouse On mezzanine ne Flooring: Sealed concrete. Electrical Type: rmal (utility power) Wall Base: 4" rubber Electrical Outlets: 1 duplex on 2 walls Ceiling Height: min. 10'-0" Ceiling: Open to structure Walls: Gypsum board, paint N/A 0 0 0 0 24" w shelf units, 24" vertical spacing, max capacity 2'x4' fluorescent fixtures recesssed in SAT. Deep cell parabolic with T-8 lamps, electronic ballast. 30 fc 7/16/10 13 of 15

M01 0 Mechanical Room 1 100 100 Electrical room On mezzanine. HVAC equipment in room or on rooftop and gas water heater. Floor drain Flooring: Sealed concrete. Electrical Type: As required Wall Base: 4" rubber Electrical Outlets: as required Ceiling Height: min. 10'-0" Ground plate Ceiling: Exposed structure - no finished ceiling Transformer Walls: Gypsum board, paint Radio equipment Fire alarm 1'x4' fluorescent fixtures hung from structure. T-8 lamps, electronic ballast. 30 fc Lockset on door. Gas water heater. 7/16/10 14 of 15

E01, E02, E03 0 Exterior Storage 3 200 600 Outside Exhaust fan Storage for tools, parts and supplies. ne Flooring: Sealed concrete. Electrical Type: rmal (utility power) Wall Base: 4" rubber Electrical Outlets: 1 duplex on 1 wall near door. Ceiling Height: min. 10'-0" Ceiling: Exposed structure - no finished ceiling Walls: Premanufactured wall, paint Built-in in Casework 24" w shelf units, 24" vertical spacing, max capacity 1'x4' fluorescent fixtures hung from structure. T-8 lamps, electronic ballast. 30 fc Premanufactured sheds (similar to shipping containers) Lockset on door. 7/16/10 15 of 15