CULTEC STORMWATER CHAMBER SYSTEMS

Similar documents
Product Catalogue. Not intended for design layouts; refer to the appropriate StormTech Design Manual for specific chamber design information.

StormTech Product Catalogue

MC-3500 and MC-4500 Design Manual

4.8. Subsurface Infiltration

BMP 6.4.4: Infiltration Trench

4.8. Subsurface Infiltration

STORMWATER MANAGEMENT

BIG O HDPE TUBING HDPE CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE INCREASE CROP YIELDS LOWER PRODUCTION COSTS

ENGINEERED SOLUTIONS. Terre Arch Concrete Detention/Infiltration. Solutions Guide

StormTech Construction Guide

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Ohio

Rainsmart Ellipse Tank O & M Guide Manual for Inspection Row

Fabrication and Installation Table of Contents

ESS EcoCell Ecological Tank Systems

PERMEABLE INTERLOCKING PAVERS

Highway Drainage 1- Storm Frequency and Runoff 1.1- Runoff Determination

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)


STORMWATER RUNOFF AND WATER QUALITY IMPACT REVIEW

MODEL Stormwater Local Design Manual. City of Centerville

MECHANICALLY STABILIZED EARTH (MSE) WALL SYSTEMS

Operation and Maintenance Manual

Features: The Most Advanced Name in water management solutions TM

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Design Manual StormTech. Chamber Systems for Stormwater Management

Aqua-Swirl Stormwater Treatment System

STANDARD SPECIFICATION STORMWATER QUALITY MEMBRANE FILTRATION TREATMENT DEVICE

Stormwater Local Design Manual For Houston County, Georgia

SECTION STORM DRAINAGE DESIGN, GRADING, AND WATER QUALITY TECHNICAL CRITERIA TABLE OF CONTENTS PAGE 402 STORM DRAINAGE DESIGN CRITERIA 400-1

PART 3 - STANDARDS FOR SEWERAGE FACILITIES DESIGN OF STORM SEWERS

Aqua-Swirl Stormwater Treatment System

SECTION 3 DRAINAGE. 3-1 General. 3-2 Drainage Ordinances and Legal Requirements

Corrugated Metal Pipe Design Guide

King County Airport Project Seattle, WA

10.0 Storm Sewer Systems

Section [ ] Storm Water Treatment Device

Features: The Most Advanced Name in water management solutions TM

Bio-Filter TM Stormwater Biofiltration System

CITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT

Stormwater Attenuation Systems Sustainable Drainage Solutions for Domestic & Commercial Applications

Filter Tube Barriers (Instream)

At least 2 feet above the seasonal high water table Overflow path or structure provided

Storm Drain Inlet Protection

7/16/2012. Post Construction Best Management Practices (PCBMPs) Article VIII: Post Construction Best Management Practices

CATCH BASIN ST-1 ENGINEERING DEPARTMENT PLATE NUMBER 3.33' 3.0' 2.0' 4.33' 3.0' 4.0' 1.00' TO BACK OF CURB LINE

Summary of the 2011 Changes

A. This Section includes subdrainage systems for foundations and underslab areas. A. Product Data: For each type of drainage panel indicated.

PERMEABLE PAVERS PHYSICAL AND GEOMETRICAL CHARACTERISTICS - PAVERS DRIVEWAYS, PERMEABLE DRIVEWAYS & PATIOS CHARACTERISTICS CSA A231.

Master Specification SECTION 02621

CHECKLIST FOR STREETS, INLETS, AND STORM SEWER DESIGN

SECTION FOUNDATION DRAINAGE

secondary containment & oil filtration solutions

DRAINAGE & DESIGN OF DRAINAGE SYSTEM

Infiltration Guidelines

BMP #: Water Quality Inserts

Module 10b: Gutter and Inlet Designs and Multiple Design Objectives

Chapter 8. Inlets. 8.0 Introduction. 8.1 General

HydraPressed Slabs. Yorkstone Tan. Wherefunctionmeetsstyle

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION PERMEABLE INTERLOCKING CONCRETE UNIT PAVEMENT

Paraprofessional Training Session 1

Table of Contents AQUA-SWIRL 2

TECHNICAL BULLETIN. Synthetic Turf Athletic Field Drainage Design Assistance

BRADLEY UNIVERSITY. The Performance and Sustainability of Permeable Pavement Progress Report on the Work Performed Under IAPA Scholarship

SECTION SPECIFICATION FOR STONEBRIDGE RETAINING WALL SYSTEM

Design Manual. StormTech. Chamber Systems for Stormwater Management

R-TANK SPECIFICATIONS

SUBSURFACE INFILTRATION SYSTEM DESCRIPTION. Alternative Names: Sump, Drywell, Infiltration Trench, Infiltration Galleries, Leach Fields

6 STOREY CONDOMINIUM 7480 DERRY ROAD WEST, MILTON

Modern Sewer Design. Canadian Edition

Standards for Soil Erosion and Sediment Control in New Jersey May 2012 STANDARD FOR GRASSED WATERWAYS. Definition. Purpose

DESIGN OF SEWER SYSTEMS

CITY UTILITIES DESIGN STANDARDS MANUAL

The exam is enclosed with this correspondence. This test emphasizes standard requirements for installing gravity-fed septic systems.

SECTION FACILITY SANITARY SEWERS

the 2001 season. Allison brought high winds and street flooding to Houston, after

COON CREEK WATERSHED DISTRICT PERMIT REVIEW. Spring Lake Park Schools Westwood Middle School st Avenue NE, Spring Lake Park, MN 55432

N.J.A.C. 7:8 Stormwater Management Rules - Design and Performance Standards. Nonstructural Strategies Assist with Strategy #2; See Page 3

Uwall UNIVERSAL CONSTRUCTION MANUAL

Project Name: Add a unique name that appropriately identifies the submission

Chapter 7. Street Drainage. 7.0 Introduction. 7.1 Function of Streets in the Drainage System. 7.2 Street Classification

Richland County Department of Public Works Engineering (Land Development) Division

Pre-Treatment Bioretention Cells Bioswales IOWA STORMWATER MANAGEMENT MANUAL DECEMBER 16, 2015

TYPE "A" CATCH BASIN

E. STORMWATER MANAGEMENT

DRAINAGE SOLUTIONS SINCE 1908 DRAINAGE SOLUTIONS QUALITY AND INNOVATION BUILT INTO EVERY PRODUCT ARMTEC.COM

NEW CASTLE CONSERVATION DISTRICT. through. (Name of Municipality) PLAN REVIEW APPLICATION DRAINAGE, STORMWATER MANAGEMENT, EROSION & SEDIMENT CONTROL

Rainwater Harvesting for Domestic Water Supply and Stormwater Mitigation

2011 Guidance Manual for Development Stormwater Quality Control Measures

Advanced Enviro-Septic TM Basic Design and Installation Manual

Erosion & Sedimentation Control Policy

SITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

Nutrient Management in. A presentation to the West Metro Water Alliance

ADS SPECIFICATIONS TABLE OF CONTENTS

Hydrodynamic Separation Product Calculator

Redi Rock Specification and Installation Manual

Review Zone Application for D&R Canal Commission Decision

SECTION UTILITY MANHOLES AND STRUCTURES

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS

CHARACTERISTICS CSA A TECHO-BLOC Compressive strength psi [45 MPa] min.

Transcription:

DRAINAGE SOLUTIONS SINCE 1908 CULTEC STORMWATER CHAMBER SYSTEMS RETENTION / DETENTION / INFILTRATION ENVIRONMENTAL PROTECTION COST-EFFECTIVE LAND USE EASY TO INSTALL ARMTEC.COM

CULTEC STORMWATER MANAGEMENT SYSTEMS Managing high levels of stormwater is a challenge facing municipalities across the country. In built-up areas buildings and paved surfaces inhibit the natural infiltration of stormwater into the ground. With expanding urbanization, existing infrastructure is unable to accommodate the increased peak flows and runoff volumes which lead to ponding and flooding problems. Conventional stormwater management systems such as ponds, swales, pipe and concrete structures capture water but are labour intensive, expensive to maintain and occupy valuable land. CULTEC Stormwater Chambers provide a cost-effective solution for underground detention and infiltration. Armtec is excited to be the Exclusive Canadian Distributor of CULTEC underground stormwater storage and infiltration chambers. In urban areas, rising land costs require developers to look for innovative stormwater management products that optimize land usage and meet local environmental regulations. CULTEC - The Founder of Plastic Chamber Technology Back in 1986 CULTEC introduced its Contactor and septic and stormwater chambers to the industry and helped to begin a revolution towards the usage of plastic construction products. Since then, several product developments and strategic alliances have made CULTEC a cutting edge R&D-based manufacturer. CULTEC s chambers are dome shaped, open-bottomed corrugated plastic structures with perforated side walls. They function like conventional stormwater ponds and work in conjunction with existing storm sewer infrastructure to provide underground retention/detention and infiltration of rainwater into the ground. Infiltration methods have been proven to be the most effective way to remove phosphorous, nitrogen, lead, zinc, suspended solids and organic carbon from water compared to wetlands, water quality ponds, filtering systems and water quality swales. 2 VISIT ARMTEC.COM FOR MORE INFORMATION

CULTEC CONTACTOR & RECHARGER CHAMBERS CULTEC Contactor and chambers can be used as detention systems, infiltration systems or a combination of both. With a wide range of sizes and models available, their advanced design and ease of installation makes them an ideal alternative to ponds, swales, concrete structures or pipe installations. CULTEC chamber systems can be installed with a Separator Row, consisting of a row of chambers surrounded by filter fabric on all sides. It is designed to capture the first flush of a rain event and is a cost effective means of removing Total Suspended Solids (TSS) that may pass through the upstream water quality structures. In addition to removing solids and debris, the Separator Row provides easier access for inspection and maintenance of the total system. TYPICAL APPLICATIONS Commercial Developments Residential Developments Industrial Areas Athletic Fields QUALITY EASE OF INSTALLATION EASE OF TRANSPORTATION AND STORAGE COST EFFECTIVE Made of durable and chemically resistant HDPE or impact-modified polypropylene Perforated sidewalls and full open bottom maximize infiltration capability and performance Lightweight components can be hand-carried into position Overlapping ribs provide a fast and secure connection Internal manifold system allows flexibility in design and on-site reconfiguration Units nest on pallets for convenient shipping and reduced freight costs Less space required in staging areas Valuable land becomes available for further development Less area and less crushed stone required for installation compared to conventional systems CULTEC CHAMBERS STACK ON SKIDS FOR EASY LOADING, UNLOADING AND STOCKPILING CULTEC CHAMBERS CAN BE HAND CARRIED FOR EASE OF INSTALLATION 3

CULTEC STORMWATER MANAGEMENT SYSTEMS CULTEC STORMWATER CHAMBERS CONTACTOR SERIES The Contactor series consists of lower profile chambers and are typically used for installations with depth restrictions or when a larger infiltrative area is required. Sizes range from 216-318 mm (8.5-12.5 in) in height. Available models are the Contactor Field Drain C-4HD and Contactor 100HD. THE CULTEC LOW PROFILE CONTACTOR SERIES CAN ACCOMMODATE SYSTEMS WITH HIGH WATER TABLES OR OTHER DEPTH CONSTRAINTS RECHARGER SERIES CULTEC s series includes higher profile, larger capacity chambers. Sizes range from 470-1219 mm (18.5-4) in height. Chamber capacities vary from 0.246-1.64 m 3 /m (2.65-17.66 ft 3 /ft). Available models within this series are the 150XLHD, 180HD, 280HD, 330XLHD and 902HD. CULTEC S RECHARGER SERIES ARE HIGHER PROFILE, LARGER CAPACITY CHAMBERS FOR MAXIMIZING STORAGE IN A SMALL FOOTPRINT Detention Systems Stormwater runoff exceeding a site s allowable discharge rate is temporarily stored in chambers connected to a control structure (manhole). Downstream flows are restricted to a set rate using an orifice. Detention/ Infiltration Systems Detention volume is set by the elevation of the outlet pipe to the control structure. Water remaining below the outlet pipe invert will infiltrate providing groundwater recharge. Infiltration Systems Water enters the chambers via the storm sewer network where it is held until the water infiltrates into the surrounding soils. Systems provide pollutant removal, total downstream volume reduction and temperature control of the downstream flow. 4 VISIT ARMTEC.COM FOR MORE INFORMATION

CULTEC CONTACTOR & RECHARGER CHAMBERS Specification Information MODEL Length (m / ft) Width (mm / in) Height (mm / in) Installed Length (m / ft) Chamber Storage Compatible End Cap Contactor Field Drain C-4HD 2.59 / 8.5 1219 / 48 216 / 8.5 2.44 / 8 0.16 m 3 /m 0.38 m 3 /unit 383.28 L 1.69 ft 3 /ft 13.54 ft 3 /unit 101 gal Contactor 100HD 2.44 / 8 914 / 36 318 / 12.5 2.29 / 7.5 0.17 m 3 /m 0.40 m 3 /unit 396.88 L 1.87 ft 3 /ft 14.00 ft 3 /unit 105 gal 150XLHD 3.35 / 11 838 / 33 470 / 18.5 3.35 / 11 3.12 / 10.25 0.25 m 3 /m 0.77 m 3 /unit 769.12 L 2.650 ft 3 /ft 27.16 ft 3 /unit 203 gal 180HD 2.23 / 7.33 914 / 36 521 / 20.5 1.93 / 6.33 0.32 m 3 /m 0.62 m 3 /unit 617.47 L 3.45 ft 3 /ft 21.81 ft 3 /unit 163 gal 280HD 2.44 / 8 1194 / 47 673 / 26.5 2.13 / 7 0.56 m 3 /m 1.21 m 3 /unit 1204.91 L 6.079 ft 3 /ft 42.55 ft 3 /unit 318 gal 330XLHD 2.59 / 8.5 1321 / 52 775 / 30.5 2.13 / 7 0.69 m 3 /m 1.48 m 3 /unit 1478.44 L 7.459 ft 3 /ft 52.21 ft 3 /unit 391 gal 902HD 1.25 / 4.1 1981 / 78 1219 / 48 1.12 / 3.67 1.64 m 3 /m 1.84 m 3 /unit 1833.53 L 17.66 ft 3 /ft 64.75 ft 3 /unit 484 gal Recharger 902HD End Cap NOTES: Based on installed length. Stone void is calculated at 40%. Most models include () stone base, () stone layer above chamber crown and stone around units based on typical minimum centre-to-centre spacing. Recharger 902HD assumes 229 mm (9 in) stone base, 305 mm (12 in) stone layer above and typical centre-to-centre spacing. MAINTENANCE To ensure a well-functioning system, regularly scheduled cleaning of catch basins and pre-treatment devices is required. We suggest the inclusion of a CULTEC StormFilter 330 or CULTEC Separator TM Row in the design for water quality and particulate removal. SAFETY FIRST! Eliminate flooding with CULTEC stormwater chambers Reduce road accidents, washouts and driver delays Minimize building and property damage, sewer backup and foundation settlement Lower clean-up costs, health hazards and environmental damage 5

CULTEC STORMWATER MANAGEMENT SYSTEMS Chamber Design The arched shape and corrugated design of the chamber effectively transfers live and dead loads to the subgrade. Stone columns between chamber rows also share in the load transfer. CULTEC chambers undergo rigorous testing. Select profiles meet the performance requirements of the American Society for Testing and Materials (ASTM) F2418, and meet the loads defined by the American Association of State Highway and Transportation Officials (AASHTO) (Section 12) Load Resistance Factor Design (LRFD) and the CAN/CSA-S6-14 CL-625 Design Truck. The Recharger 902HD has achieved third-party certification to the Canadian Standards Association (CSA) B184 standard for polymeric subsurface stormwater management structures. Chambers are constructed of impact-modified and long-term creep resistant polymers, ensuring that the chambers achieve a minimum 50-year service life. Let us help you with your next project! Contact an Armtec Representative to arrange complimentary design assistance. You ll receive stage-storage calculations, CAD layouts, details and product submittal packages. CULTEC s intuitive design tools are also available to complete your own design. Download the CULTEC Stormwater Design Calculator, Incremental Storage Calculator and CAD design templates to complete an accurate, site-specific layout complete with stage-storage calculations. CULTEC s Automated StormGenie Program quickly generates CAD layouts, material lists and calculations for preliminary designs. Visit www.cultec.com/stormwater-design.html for design assistance. SCAN THIS CODE 6 VISIT ARMTEC.COM FOR MORE INFORMATION

Installation Minimum Fill Requirements for Paved Traffic Applications Refer to CULTEC s most current installation instructions for further details including but not limited to acceptable fill materials and vehicle loads. If these models and design parameters do not meet your site parameters, please contact an Armtec Sales Representative for further information. Ref. Contactor Field Drain C-4HD Contactor 100HD 150XLHD 180HD 280HD 330XLHD 902HD Min. depth of stone base A 229 mm 9 in Chamber height B 216 mm 8.5 in 318 mm 12.5 in 470 mm 18.5 in 521 mm 20.5 in 673 mm 26.5 in 775 mm 30.5 in 1219 mm 4 Min. depth of stone required above units for traffic applications C 305 mm 12 in Min. depth of 95% compacted fill required for paved traffic applications D 254 mm 10 in 305 mm 12 in Max. depth of cover allowed above crown of chamber E 2.53 m 8.3 ft Chamber width F 1219 mm 4 914 mm 3 838 mm 33 in 914 mm 3 1194 mm 47 in 1321 mm 52 in 1981 mm 7 Typical centre-tocentre spacing G 1.22 m 4 ft 1.02 m 3.33 ft 0.99 m 3.23 ft 0.99 m 3.23 ft 1.32 m 4.33 ft 1.47 m 4.83 ft 2.21 m 7.25 ft NOTES: Structurally designed to withstand HS-20/HS-25 live loads in accordance with AASHTO 25-50 mm (1-2 INCH) DIA. WASHED, CRUSHED CLEAR STONE CULTEC HEAVY DUTY CHAMBER CULTEC HVLV FEED CONNECTOR FINISHED GRADE MIN. 95% COMPACTED FILL 136 g/m2 (4.0 oz/yd2) NON-WOVEN GEOTEXTILE* AROUND STONE, TOP AND SIDES ARE MANDATORY 305 mm (12") TYP. 203 g/m2 (6.0 oz/yd2) WOVEN GEOTEXTILE* TO BE PLACED UNDER ROWS UTILIZING INTERNAL MANIFOLD FEATURE *Contact Armtec for specific models of Geotextiles. 7

CULTEC, CULTEC logo, CONTACTOR and RECHARGER are trademarks of CULTEC, Inc. registered in the U.S. and Canada. 100HD, 150XLHD, 280HD, 330XLHD, V8HD, 902HD and The Chamber With The Stripe are trademarks of CULTEC, Inc. Copyright in all drawings, illustrations, photos, charts CULTEC, Inc. All rights reserved. Protected by one or more of the following patents owned by Cultec, Inc.: U.S. Patents 6,129,482; 6,322,288; 6,854,925; 7,226,241; 7,806,627; 8,366,346; 8,425,148; U.S. Designs D613,819; D638,095; D668,318; Canadian Patent 2,450,565; 2,591,255; Canadian Designs 129144; 135983; 159073; 160977; and/or other U.S. or Foreign Patent(s) or Patent(s) Pending. Find out how CULTEC s Stormwater Chamber Systems can be used on your next project. Contact us today. Solutions for a Better World Armtec is a leading provider of infrastructure solutions that deliver social, environmental and economic benefits for an ever-changing world. 1-877-5-ARMTEC ARMTEC.COM Drawings and product details are for information and/or illustrative purposes only, and may vary. Please contact your local Armtec representative for the most current product information. CULTEC STORMWATER CHAMBER SYSTEMS / PRODUCT GUIDE 2017-11 PROD-C02-G09-P08_PG-2017-11-E