NACE CORROSION 2008 TEG 096X Symposia - Paper 1421

Similar documents
IWC ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

EFFECTIVE USE OF RECYCLED WATER IN COOLING TOWERS WITH NEW GREEN TECHNOLOGY. Abstract

13 th Annual GC&EC Green Corrosion Inhibition and Water Treatment Session

Green Corrosion Inhibition and. (NGC) for Cooling Water Treatment. Report by Dan Duke Water Conservation Technology International

IWC REPORT ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

ZERO LIQUID DISCHARGE OPERATION OF COOLING TOWERS AT A MAJOR STEEL MILL

COOLING TOWER WATER TREATMENT

Distribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives

"Significant Cost Savings Obtained Using Advanced Membrane Systems for Cooling Tower Water Treatment and in ZLD plants

EXHIBIT A UNIVERSITY OF NEVADA - LAS VEGAS WATER TREATMENT BEST PRACTICES

COMPREHENSIVE REPORT PRE CLEANING & PASSIVATION PROGRAMME OF ENTIRE RECIRCULATING COOLING WATER SYSTEM OF ECO PLANT BILAG INDUSTRIES LTD.

Wastewater Characterization. Tenaska Westmoreland Generating Station

CORROSION BEHAVIOR OF TITANIUM METAL IN PRESENCE OF INHIBITED SULFURIC ACID AT 50 o C 1

high cycles cooling tower operation using a revolutionary alkaline treatment program Continuum* AEC (Alkyl Epoxy Carboxylate)

Water Talk. Volume 8, Issue 8 August 2008 Zero Blowdown, Reality or Fantasy? A Critical Look at the Claims and Possibilities

Cooling Tower Water Conservation: Simple Strategies & Advanced Treatment Eric Elam Water Savers LLC, RTS Water August 15 th, 2017

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

COOLING TECHNOLOGY INSTITUTE

Laboratory Fee Schedule

Nadeem Shakir Qatar Petroleum. The 2nd Joint Qatar Japan Environmental Symposium, QP JCCP The 21st Joint GCC Japan Environmental Symposium

Concentration mg/l TDS mg/l 10, ,000 Recovery 75% Waste TDS mg/l 44,000 COD mg/l 3,500 0 BOD NTU 1,250 0 Power Used kwh/m3 2.

RECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY

Membrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership

Laboratory Experiments in Corrosion Engineering II

ADDENDUM 2 TO REQUEST FOR PROPOSAL 673-FG UNLV FULL SERVICE WATER TREATMENT

Legionella Outbreak Prevention for Cooling Towers

Zero Discharge Treatment Method for Cooling Towers and Heat Exchangers with SP3, I-SOFT-OB, OXYDES & KATALOX LIGHT

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER

Studies on performance of indices in cooling water system

Purification of Brackish Water using Hybrid CDI-EDI Technology

Pretreatment of Industrial Wastewater for ZLD/Resources Recovery

Slow Release Corrosion Inhibiting Block Boris Miksic, Margarita Kharshan, Ming Shen, Alla Furman, Ali Bayane

By C.F. Chubb Michaud, CWS-VI

Cooling tower efficiency U2 Eco-efficiency resources for the food processing industry

Galvanic Corrosion Prevention Guide for Water Cooling Systems

Hard water. Hard and Soft Water. Hard water. Hard water 4/2/2012

Complete Water Analysis for POWER GENERATION

Green Technologies to Minimize Cooling Tower Water Use

Condensate System Troubleshooting andoptimization

Solus* AP - advanced boiler all-polymer internal treatment technology

ELECTRONIC GRADE SULFAMATE NICKEL Document ID: EFM1409

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

EVALUATION OF A CHEMICAL CLEANING FORMULATION FOR THE STEAM GENERATOR OF NUCLEAR POWER PLANTS

Purification of Brackish Water using Hybrid CDI-EDI Technology. by Robert Atlas, Aqua EWP, LLC. San Antonio, TX

Cooling Water Treatment

Cooling Tower Water Savings Stakeholder Meeting #1 - DRAFT California Statewide Utility Codes and Standards Program

Higher COC and ph Independent Operation of Cooling Water Systems

COOLING TECHNOLOGY INSTITUTE

TDS AND SLUDGE GENERATION IMPACTS FROM USE OF CHEMICALS IN WASTEWATER TREATMENT

Liquid Filtration for Chlor- Alkali Plants

One of the main ores of zinc is zinc blende, ZnS. There are two stages in the extraction of zinc from this ore.

EMA4303/5305 Electrochemical Engineering Lecture 05 Applications (1)

FILMTEC Membranes System Design: Introduction

CHANGING THE GAME FOR DESAL

Operation of Hydranautics New ESNA Membrane at St. Lucie West, FL Softening Plant

Cooling Tower Water Management

The Use of Phosphates in Water Treatment for Corrosion Control & Sequestration CARUS CORPORATION

ONLINE MONITORING OF CORROSION UNDER CATHODIC PROTECTION CONDITIONS UTILIZING COUPLED MULTIELECTRODE SENSORS

0 50 Very soft Soft Medium Hard

INDEPENDENT ASSESSMENT OF THE PREMATURE FAILURE OF THE X- 670A COOLING TOWER COILS

Environmental Sustainability through the use of Nalco 3D TRASAR Technology for Sea Water Cooling tower

Zero Liquid Discharge Effluent Guidelines Compliance Strategies for Coal-Fired Power Plants FGD Wastewater

Steamate* technology. superior protection against condensate system corrosion. Water Technologies & Solutions technical bulletin

Use of Spiral Wound UF in RO Pretreatment

Water Treatment Program. Training Manual

COOLING TOWER (CT1 AND CT2) SPECIFICATIONS. Description CT-1 CT-II Circulation rate 4000 M3/hr 6000 M3/hr Induced Draft Counter Flow

Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India Reducing the water footprint in coal fired power plants

Dynalene Ethylene Glycol Series

Studies on Alloys and Composites that Undergo Anomalous Codeposition

Nathan Kofira Technical Development Manager

ONLINE MONITORING OF UNDERCOATING CORROSIONS UTILIZING COUPLED MULTIELECTRODE SENSORS. Xiaodong Sun Corr Instruments, LLC San Antonio TX, USA ABSTRACT

Localized Corrosion of a 7075 Aluminum Alloy Exposed to KCl

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

85 Q.51 Which of the following carbonates would give the metal when heated with carbon? (1) MgCO 3 (2) PbCO 3 (3) K 2 CO 3 (4) CuCO 3

Recovery and reuse of water from effluents of cooling tower

PURPOSE PROCESS PAYOFF

Slow Release Corrosion Inhibiting Block

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

The Basics of Dezincification

Lead & Copper Control with Phosphates Darin Skutt Technical Service Manager Carus Corporation

SCHMITZ REINIGUNGSKUGELN GmbH Hildesheimer Strasse 7, D HOLLE

A. Submit manufacturer s data, qualifying documents, and shop drawings on the proposed water treatment system before starting any work.

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

REMOVAL OF HARDNESS BY PRECIPITATION

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

White Paper. by Jeffrey Kochelek V.1.0.2

Interpretive Guide & Summary Statistics

Protection Effectiveness of Vapor Corrosion Inhibitor VpCI 619 for Corrosion Under Insulation at Elevated Temperatures

Corrosion Issues & Test Methods. Jerry Byers

Drinking Water Corrosion Control and POU/POE Treatment

Worldwide Pollution Control Association

METAL FINISHING. (As per revised VTU syllabus: )

Test sticks and test papers for semi-quantitative determinations

Water for Instrument Processing

NIPPON PAPER RO SYSTEM + 2 Others

Cooling Tower Blowdown Treatment and Reuse in a Coal Fired Power Plant in India - Reducing the water footprint in coal fired power plants -

Electrochemical Considerations

Estimation of total, permanent and temporary hardness of water (EDTA method)

Oxidation and Reduction

Module-13. Corrosion and Degradation of materials

Transcription:

NACE CORROSION 2008 TEG 096X Symposia - Paper 1421 Electrochemical Studies with Coupled Multielectrode Array Sensors on Corrosion Inhibition of Copper and Affected Metals in the Presence of Ammonia and Other Corrosive Ions In Zero Liquid Discharge Cooling Water Dan Duke Water Conservation Technology International, Inc. Temecula, CA Lietai Yang Corr Instruments, LLC San Antonio, TX

Presentation Outline Wastewater Reuse in Zero Liquid Discharge (ZLD) Towers Corrosion of Copper by Ammonia Coupled Multielectrode Array Sensor (CMAS) Corrosion Studies Municipal Reuse Case History Galvanized Metal Study 2

This technology is patent protected; US 6,929,749 / Silica Scale Control US 6,949,193 / Silica Scale Control US 6,998,092 / Corrosion Inhibition/Silica US 7,122,148 / Corrosion Inhibition/Silica Additional patents are pending

Wastewater Reuse in Zero Liquid Discharge (ZLD) Towers Silica Inhibition Chemistry

Reuse of Wastewater for Cooling Tower Makeup Waste water requires treatment to remove suspended solids (TSS) & insoluble organics Filtered to remove TSS that would foul softener Need high efficiency softening (HES) Dissolved solids (TDS) must be low enough to permit ion exchange softening Natural high silica and alkalinity desirable Ammonia and soluble organics do not have to be removed with ZLD / silica chemistry 5

Cost Benefits of ZLD Tower Operation High efficiency softening lowers salt use (4# per CF resin) and brine waste flow (< 2% MU) Typical softening cost of $0.12 per 1000 gallons tower makeup Both equipment and operating cost is 10-15% of conventional ZLD / discharge reduction systems Optimum water use and discharge reduction Reduced wastewater discharge obtained with use of waste heat (low carbon footprint) 6

ZLD / Silica Chemistry Expanded Options Permits use of alternative water sources such as municipal / industrial reuse, RO reject, and high TDS water sources for tower makeup Silica inhibits metals from corrosion by high TDS (azoles needed for copper / ammonia) Expands metal selection / cost economy Soft water eliminates scale limitations and permits higher temperatures Biostatic chemistry mitigates micro-bio activity 7

Corrosion of Copper by Ammonia

Corrosion Rates of Several Copper Alloys in 0.8% Ammonia at 104 o F (40 o C) Alloy Corrosion Rates mpy mm/y Copper 14 0.30 Brass (Cu-Zn, 70:30) 7 0.20 Alloy 905 (Cu-Sn-Zn) 5 0.10 Cu-Mn (95:5) 2 0.05 Source: Radley, Stanley and Moss, Corrosion Technology 6:229:1959 9

Copper Corrosion Inhibition Study (Azoles in High Ammonia / ZLD Water) Study with 150,000 mg/l TDS / ph 10 / soft tower water inhibited by silica and azoles exposed to ammonia (200-400 mg/l) Rapid uninhibited corrosion by ammonia Azoles highly effective for inhibiting ammonia attack at high ph / TDS High ph treatment method increases azoles effectiveness / cost efficiency 10

Copper Corrosion Inhibition by TTA (Ammonia / ph 10 and 150,000 TDS) Copper / TTA / Ammonia Study and Weight Loss Results ZLD Tower Water NH4 +, mg/l TTA, mg/l Cu, mg/l CR, mpy Wt. loss Sample # 1 0 0 0.7 Beginning 300 0 0.7 2.5 After 48 hours 300 0 40 Sample # 2 0 0 0.7 Beginning 300 200 0.7 0.0 After 48 hours 300 200 0.7 11

CMAS Corrosion Studies Localized Corrosive Effects of Ammonia, High TDS, High ph on Copper Zinc and Aluminum

15% NaCl solution with ph adjusted, no Inhibitors, Ammonia / TDS / ph corrosive effect on Cu and Zn 1000.00 Copper 110 Zinc 100.00 Maximum Rate (mpy) 10.00 1.00 0.10 ph=8.15 NaOH added, ph =10 using 125 ppm ammonia added ph=10.75 0.01 7/21/07 7/22/07 7/23/07 7/24/07 7/25/07 7/26/07 Date 13

Silica Inhibited ZLD Water, Zn & Al Inhibited, Cu corroded by Ammonia / TDS / ph Maximum Rate (mpy) 10.00 1.00 0.10 Aluminum 1100 Copper 110 Zinc 125 ppm ammonia added 250 ppm ammonia added 0.01 7/7/07 7/9/07 7/11/07 7/13/07 7/15/07 7/17/07 7/19/07 7/21/07 Date 14

ZLD (150,000 TDS) / Silica treated Tower Water: Ammonia and TDS Corrosion of Copper inhibited by TTA Maximum Rate (mpy) 10.000 1.000 0.100 0.010 125 ppm ammonia added 375 ppm ammonia added Aluminum 1100 Copper 110 Zinc Probes newly polished 0.001 7/22/07 7/27/07 8/1/07 8/6/07 8/11/07 8/16/07 8/21/07 8/26/07 Date 15

CMAS Study Summary Uninhibited localized corrosion rates with ammonia and high TDS were 2.5 mpy for copper and 80 mpy for zinc (room temperature) Silica inhibited localized corrosion rates for zinc and aluminum were negligible from ammonia / high TDS; copper was not well inhibited Copper was inhibited by TTA to negligible corrosion rate from high ammonia / high TDS 16

Municipal Reuse Case History Municipal Reuse water used for makeup to ZLD Tower Operation

Cooling Tower Using High Ammonia (Reuse) Waste Water for Makeup High ammonia (34 mg/l) reuse makeup water High hardness and phosphates limit traditional COC (concentrations of chemistry) of makeup in tower High TDS limited traditional corrosion protection Copper chiller and absorber tubes at risk from ammonia Required multimedia filtered and HES softened makeup ZLD / high ph / high TDS with silica & TTA inhibitors Ammonia stripped to < 0.5 mg/l at 60 COC by chemistry Corrosion of copper inhibited to 0.007 mpy. Micro-bio growth (organics) mitigated (10 o Col / ml). 18

Tower Ammonia Stripping In a waste stream, ammonium ions exist in equilibrium with ammonia. 1. Below ph 7, virtually all the ammonia is soluble ammonia ions. 2. Above ph 12, virtually all the ammonia is present as a dissolved gas. 3. Between ph 7 and 12, both ammonium ions and dissolved gas exist together. 4. Percentage of dissolved gas increases with ph / temperature. 5. Elevated ph and temperature favor removal of ammonia from solution as the gas when water is scrubbed over a tower. 19

ZLD Cooling Tower using (California Title 22) Municipal Reuse Waste Water for Makeup Tower / Soft Makeup COC (Concentration of Chemistry) Ratios Sample / Tests (01/04/08) Tower Soft MU COC TDS, mg/l (Myron L 6P, 442) 66000 1100 60 ph 9.85 7.3 NA Silica, mg/l SiO 2 530 20 27 Calcium, mg/l CaCO 3 18 0.2 NA Magnesium, mg/l CaCO 3 13 0.1 NA Sulfate, mg/l SO 4 7700 128 60 Chloride, mg/l NaCl 12500 212 59 Tot. Alkalinity, mg/l CaCO 3 15000 257 58 Ammonia, mg/l NH 4 < 0.5 38 NA Total Phosphate, mg/l PO 4 52 0.9 58 TTA, mg/l as tolytriazole 5 NA NA 20

Corrosion Rates for ZLD Cooling Tower with Reuse Makeup Water Linear Polarization and Weight Loss Corrosion Rates (Water treated with silica and TTA inhibitors) Mild Steel (1008) Copper (110) Linear Polarization (mpy) Coupon Weight Loss with 60 day exposure (mpy) 0.2 < 0.1 0.22 0.007 21

Biostatic Monitoring Dip stick cultures 10 o Col / ml @ 48 hours No bio slime deposits on tower fill No slime in chillers or absorbers No odor No biocide use or handling 22

Natural Biostatic Chemistry Natural source water alkalinity and TDS Elevated ph and TDS are naturally biostatic to bacteria, spores and viruses Hydrolysis of peptide chains as water ph is increased (used in waste treatment) Denaturing of proteins or enzymes by elevated TDS Report by Anderson Engineering 23

Non-scaling Water Savings HES softening provides non-scaling water Permits high COC or ZLD operation Water use was reduced 30% (reduced tower blowdown) Reuse water cost / HCF was 30% less Total water use cost reduced 50% Equipment ROI less than 12 months Minor chemical use (TTA) 24

Galvanized Coating Passivation Study ZLD Cooling Water

ZLD Tower Water Chemistry Tower / Soft Makeup COC (Concentration of Chemistry) Ratios Filtered Sample / Tests Tower Soft MU COC Sample TDS, mg/l (Myron L 6P) 146,000 251 582 ph 10.07 7.58 Copper, mg/l Cu 0.7 0.25 0.0015 467 Iron, mg/l Fe 22.2 ND ND Zinc, mg/l Zn 3.8 ND ND Silica, mg/l SiO 2 1,050 30 35 Calcium, mg/l CaCO 3 62 12.4 <0.1 Magnesium, mg/l CaCO 3 16 8.2 <0.1 Phosphate, mg/l PO 4 89 0.15 593 Nitrate, mg/l NO 3 2590 4.5 575 Sulfate, mg/l SO 4 10,260 18 570 Chloride, mg/l NaCl 22,400 38 589 Tot. Alkalinity, mg/l CaCO 3 69,400 120 578 26

Galvanized coupon #283 exposed in ZLD tower for 60 days vs #282 control before & after coating striped 27

ZLD Chemistry / Passivation of Galvanized Coatings Galvanized coatings protected by silica Not affected by high alkalinity / ph / TDS Residual copper from source water may deposit on non-passivate coating Micro pitting of non-passivate coating TTA / azoles (25 mg/l active dose) at start up very effective to passivate coating Periodic azoles dose for residual copper 28

Galvanized Coupon exposed 60 days in ZLD tower with TTA Supplement to Silica Inhibitor 29

ZLD / Silica / TTA Chemistry Summary No scale threat with ZLD operation Negligible corrosion at very high TDS Unaffected by reuse (ammonia) waste water Ammonia and organics stripped by chemistry Copper protected from ammonia Mitigates biological and pathogen growth Simple control chemistry Reduced water use and discharge cost 30

Questions? 31