Water-Cooled Screw Chillers and Water/Water Heat Pumps

Similar documents
Air-cooled Chillers with High Speed Centrifugal Compressors

Transform your HVAC performance. Good for your comfort, for the environment and for your bottom line

Trane eflex. For Ton Light Commercial Applications

WATER CHILLER / HEAT PUMP. The high performance packaged solutions for all your needs

Industrial heat pumps and cooling machines Oilon ChillHeat. Optimized heating and cooling performance

Trane Precedent 3- to 10-ton light commercial rooftop units

Voyager kw rooftop units Plug and Play comfort in commercial applications

Xe-90/145M Series Controllers. Rotary Compressors

Powering solar-ready rooftops with PV panels

CenTraVac Chillers The most efficient and reliable centrifugal chillers on the planet

CLCF Climate Changer for comfort applications. Next generation air handling performance from Trane

Light commercial rooftop units Retail applications

FRESH OR FROZEN. FASTER IS BETTER.

LEED. Leadership in Energy and Environmental Design

Centrifugal Air Compressors. Centac C m 3 /min

Sullair Water Chillers. Precision Chilled Water

MAXE YST Steam-Turbine Drive Chillers

Heat Pumps from Viessmann: Efficient heating with ambient heat

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

The best chiller choice for large CHP plants. MaxE YST STEAM-TURBINE-DRIVE

ANK. ANK heat pump All the heat you want more efficiency more savings more well-being

york yvwa variable-speed, water-cooled, screw chillers Infinite chiller configurations to help you achieve your goals

A chiller as unique as your needs. YORK YVAA AIR-COOLED SCREW CHILLERS

Trane University 2018 Course Schedule. Educational and Instructional Training for the HVAC Industry. Training Schedule

Flooded Type Water-Cooled Chillers. R134a

GLAC BD2. Lufttechnik. GEA Heat Exchangers / HVAC Systems

Renewable Energy. to heat your home. thermia.com

The most reliable and longest lasting in the industry.*

Air Cooled Packaged Air Conditioning

Optimizing the Features of a Customizable Air-Cooled Chiller

Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics

INDOOR UNITS FVXS25F FVXS35F FVXS50 F

Arkema technical note. Forane 407A. The low-gwp and energy efficient alternative to R-404A and R-507A

Deployment of a New Series of Eco Turbo ETI Chillers

Cooling capacity from 165 to 700 kw. Air cooled chiller APPLIED SYSTEM. Engineered for flexibility and performance

Industrial Refrigeration. Highly flexible and reliable solutions that save energy and increase your coefficient of performance


MPE 4-76 kw. Outdoor packaged unit. Air/water chillers and heat pumps MPE. Efficiency under all operating conditions. 152 galletti.

Climate Control Solutions. Geothermal. A New Level of. Comfort. & Reliability.

Build better buildings. Choose superior chillers. YORK YMC 2 MAGNETIC CENTRIFUGAL CHILLERS

Honeywell Refrigerants Improving the Uptake of Heat Recovery Technologies 1

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.

EES Energy Efficient Systems Rotary Screw Air Compressors kw Horsepower

Optimizing the Features of a Customizable Air-Cooled Chiller

EU F-Gas Regulation Guidance Information Sheet 16: Manufacturers and Importers of Refrigeration, Air-Conditioning and Heat Pump Equipment

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump

Packaged AHR (Advanced Heat Recovery) Systems for Engines, Gas Turbines, & Industrial Waste Heat. Tom Pierson

Nilan VPL Active heat recovery and cooling (air/air)

Absorption Chillers in Commerce

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

Rebel commercial packaged rooftop systems

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Standardizing Smart/Connected Products in a Highly Innovative and Dynamic Market

Robert Kebby February BUILDING BLOCKS OF THE FUTURE Commercial Refrigeration Applications

B. System Design and Performance Requirements

SGM Engineering, Inc.

The Charles Machine Works Perry, OK

MD-200/MD-300/MD-200 MT

Meet the new T-80 Series

QUICKTEMP TECHNOLOGY IMPROVED EFFICIENCY ACROSS THE ENTIRE T-80 RANGE OF UNITS

PureCycle 200 Heat-to-Electricity Power System

DELIVER THE FULL POTENTIAL OF YOUR PROJECTS WITH WATER, THE BEST HEAT TRANSFER FLUID

22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

DISTRICT HEAT DRIVEN ABSORPTION COOLING OF DISTRICT COOLING PLANTS IN TRONDHEIM, NORWAY

Positively Innovative. R407H introduction Daikin Refrigerants Europe Daikin Chemical Europe

ECODESIGN PREPARATORY STUDY FOR AIR-CONDITIONING AND VENTILATION SYSTEMS ENTR LOT 6

Chemical Specialties Innovative chemistry

Organic Rankine Cycle Technology

19XR Two-stage Centrifugal Chiller

Control Products & Systems OEM siemens.com/buildingtechnologies-oem

Thermally operated mobile air-conditioning system

Energy Efficiency. best in class

Daikin LXE10E Reefer Machine

The OriGen. Clean, Renewable Power From Waste Heat. AERCO.com

AERONA 3 HEAT PUMP RANGE. Inverter driven air source heat pumps with outputs from 6kW to 16kW

T U R B O B L O W E R S

2. Ground Source Heat Pumps Invitations to complete questionnaire Responses received... 7

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Natural Refrigerant Alternatives for Industrial Refrigeration

Combined heat and power units up to 401 kw el. and 549 kw th

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.40

Innovative Solutions from Mitsubishi Electric

The answer is... yes!

HEAT PUMPS A RELIABLE, OPTIMAL INDOOR CLIMATE HEATING SOLUTION FROM THERMIA

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

TABLE OF CONTENTS SELECTING AN ENCLOSURE COOLING SYSTEM MANUFACTURER. 3 7 QUALITIES TO LOOK FOR IN A MANUFACTURER Manufacturer Location..

St. Clair County Road Commission. For Turn Key Replacement of the Existing Chilled Water System Page 1 of 6

a f f i n i t y s e r i e s C O M M E R C I A L P A C K A G E D S Y S T E M S

SECTION ROTARY SCREW WATER CHILLERS

Forward-looking and energy efficient Biomass heating

Geothermal Comfort Systems

trusted innovative expertise

Central Chiller Plants

November 4, 2010, Rev 1

Gaining Competitive Advantage through Improved Energy Efficiency and Reduced Environmental Impact

TRANQUILITY WATER-TO-WATER SERIES

District Energy in Toronto. Climate & Clean Air Coalition Sustainable Technologies for Air-Conditioning Workshop November 18 th, 2017

HEat PumP technology FoR underfloor HEatINg comfortheat.com.au

Performance is now driven by the TRIDO Industries suite of solar powered products: Innovative and environmentally sustainable solutions designed to

Cogeneration. Thermal Chillers. and. .. ASHRAE National Capital Chapter. Arlington, VA 10/10/2012

Transcription:

Water-Cooled Screw Chillers and Water/Water Heat Pumps Model RTWF (R134a) 940-1860 kw Model RTWF G (R1234ze) 735-1420 kw Model RTHF (R134a) 1120-3180 kw 1

Trane XStream Water-Cooled Chillers and Water/Water Heat Pumps There is world-wide demand for increasingly efficient products to reduce energy and resource consumption. As part of our sustainable product policy, Trane has always been committed to respecting the environment by reducing energy consumption through the delivery of high performing and efficient products and systems. Trane XStream series provides reliable temperature control in the most demanding applications. Exceptional efficiency keeps your operating costs and environmental impact low. Smart and easy to use controls ensure you get the best out of your system day after day, year after year. The model RTWF is available with a choice of refrigerants: R134a or R1234ze which has a GWP value of less than one to exceed current F-Gas legislation requirements and help customers reduce carbon dioxide (CO 2 ) emissions and achieve extreme part load and full load efficiencies. XStream chillers and heat pumps are ideal for Cooling and heating applications High and medium temperature industrial process applications Office buildings Healthcare Data Centers Automotive industry Pharmaceutical industry Food and beverage industry Hospitality industry District Cooling District Heating 2 Water-Cooled Chillers and Water/Water Heat Pumps

Range Description A model for every need Whether your priority is to reach ultra high efficiencies, benefit from low first costs, or have a quicker return on investment, there is a model in the Trane XStream range that will meet your needs. 700 900 1100 1300 1500 1700 1900 2300 2700 3100 kw RTWF SE RTWF HE RTWF HSE RTWF G SE RTWF G HE RTWF G HSE RTHF XE RTHF HSE Up to 5.4 EER (Gross) 7.8 ESEER (Gross) A Up to 5.3 EER (Gross) 6.9 ESEER (Gross) A Up to 6.3 EER (Gross) 9.3 ESEER (Gross) A Outstanding energy efficiency The design of our new XStream chillers and heat pumps has been guided by the need to achieve the lowest energy consumption. Units deliver market leading part load and full load efficiency performance. You can choose from four efficiency levels: Standard Efficiency (SE) High Efficiency (HE) Extra High Efficiency (XE) High Seasonal Efficiency (HSE) with integrated variable speed: Trane Adaptive Frequency Drive. Trane exceptional reliability With equipment as critical as an HVAC system or industrial process, quality is non-negotiable. At Trane we manufacture and design the core components and put our systems through extremely rigorous performance and reliability tests. All Trane units are given a complete test before leaving our factory. As a result, Trane customers benefit from proven, industryleading reliability and durability. Extreme versatility Whether you have seasonal comfort requirements or a sensitive industrial application there is a model from the XStream range that will satisfy your needs. By selecting the appropriate efficiency version, you can minimize your Total Cost of Ownership. For even greater system efficiency, Trane XStream units are fully compatible with Variable Primary Flow (VPF) applications and Series chiller arrangements. 3

The Future of F-Gases The fluorinated refrigerants phase-down, as defined in the new EU F-Gas Regulation, is a step-by-step approach where the quantities of HFCs expressed in CO 2 equivalent that are placed on the market are gradually reduced. As a result of the phase-down, HFC consumption will be reduced by 79% by 2030. This is an unprecedented reduction and means that industry and users need to make, over time, the transition to refrigerants with a lower global warming potential. Trane, recognized as a leading innovator in the HVAC industry, introduces this new, next generation, lower GWP refrigerant in Sintesis and other products to be front running in the marketplace and to support your strong sustainability objectives. Ingersoll Rand and Trane - providers of sustainable solutions. HFC consumption 100% 90% 93% 80% 70% 60% 63% 50% 40% 30% 20% 10% 45% 31% 24% 21% 0% 2015 2016 2018 2021 2024 2027 2030 Baseline value (100%) is the annual average of total quantity of CO 2 equivalents placed on the EU market from 2009 to 2012. 4 Water-Cooled Chillers and Water/Water Heat Pumps

An environmentally sustainable solution Sintesis chillers with low GWP refrigerants are part of the Ingersoll Rand EcoWise portfolio of products that are designed to lower their environmental impact with next-generation, low global warming potential (GWP) refrigerants and high-efficiency operation. New R1234ze Ozone depletion potential = 0 Low global warming potential (GWP<1) Refrigerant Global Warming Potential (GWP) R410A 1924 R407C 1774 R134a 1300 R513A 572 R1233zd 1 R1234ze <1 What is GWP? GWP is the global warming impact relative to the impact of the same quantity of carbon dioxide over a 100 year period. What is ODP? Ozone depletion potential of a chemical is the amount of degradation to the ozone layer it can cause. 5

XStream chillers: the smart choice for cooling applications Because chillers rarely operate at design conditions, Trane developed the XStream range to achieve industry-leading part load efficiencies without compromising the environment. Unique and innovative features Multiple compressor design allows outstanding part load efficiencies by switching compressors off while utilizing the entire heat exchanging surface for the remaining compressor(s) XStream chillers and heat pumps take advantage of crossflow serial heat exchanger design to reduce compressor workload under all operating conditions. Variable Primary Flow (VPF) capabilities VPF VPF systems provide building owners with multiple cost savings derived directly from pump operation. The XStream series is designed to make VPF easy to use. The evaporator on the XStream series can run safely with up to 50% water flow reduction The microprocessor and capacity control algorithms are designed to handle a maximum of 10% change in water flow rate per minute in order to maintain ±0.3 C temperature control leaving the evaporator. For applications in which system energy savings are the priority and tight temperature control is classified as +/- 1.1 C, up to 30% change in flow per minute is possible. With the help of a TRANE software analysis tool, you can determine whether the anticipated energy savings justify the use of VPF in a particular application. 6 Water-Cooled Chillers and Water/Water Heat Pumps

Multiple chiller plants Overall efficiency can be further improved by using an alternative chiller lay-out to the conventional parallel-piped configuration. For example, chillers can be piped in series, on the evaporator side, on the condenser side or both. 30 C 2.1 MW 35 C 27 C 37 C 31 C 2.3 MW 10 C 2.0 MW 15 C 2.1 MW 12 C 5 C 7 C This layout provides the opportunity for Lower chilled water design temperature with larger ΔT Reduced design flow Installation and operational cost savings by fewer installed pumps and valves, reduced pipe diameters and chiller downsizing Maximized system efficiency Continuous temperatures allow better stability of controls By combining series configuration with Variable Primary Flow (VPF) it is possible to further increase system efficiency. 7

XStream heat pumps: ideal for heating applications The market for heat pumps in Europe has grown substantially year over year as the advantages of heat pumps are proven. Trane introduces new technologies creating sustainable solutions using renewable energy. Unique and innovative features Trane XStream heat pumps are a smart alternative to traditional boilers with features which effectively address the needs of geothermal and district heating applications: Compressors specially designed for high temperature applications Large capacities up to 2030 kw (at Eurovent Air Conditioning heating conditions) High condensing water temperatures of up to 85 C (RTWF G) allowing operation as a high temperature heat pump or a high condensing temperature cooling system. High performance up to 5.0 COP (at Eurovent Air Conditioning heating conditions) Operates down to 10% part load requirements. High condensing water temperatures of up to 85 C. 85 C 8 Water-Cooled Chillers and Water/Water Heat Pumps

Peace of mind while saving energy costs Thanks to the high leaving-condenser temperatures that RTWF/RTWF G models are able to achieve, costly auxiliary heating sources to treat Legionella bacteria can now be scaled back or totally eliminated. Geothermal applications The technologies built into Trane s XStream series heat pumps make them ideally suited to geothermal applications. Trane air handling units Central XStream units to produce hot/cold water for heating and cooling Geothermal loop 9

Features Innovative solutions to your needs 1 Trane industry-leading compressor* Direct drive, twin screw helical rotary design Infinite capacity modulation Semi hermetic design eliminating shaft seals Trane unequaled reliability 1 2 3 4 Model RTHF 3 Trane combined smart control and interface* Leading TD7 touch screen with 7 color display Clear presentation of critical information Monitor settings, data trending, reports and alarms Simple, intuitive navigation Effective operation, monitoring and management Durable construction for both indoor and outdoor use 4 Heat exchangers* Single pass Counter flow configuration Connectivity Full interoperability via SmartCom interface Lontalk, BACnet and Modbus Full remote control capability via Trane BMS or Chiller Plant Controls * Trane Proprietary Technology 10 Water-Cooled Chillers and Water/Water Heat Pumps

2 Adaptive Frequency Drive on HSE version* Improved efficiency under part load conditions Improved capacity modulation Dual independent refrigerant circuits Provide redundancy Reduce the impact of any failure 1 2 Two different refrigerant alternatives on RTWF R134a R1234ze with GWP<1 3 4 Model RTWF Tracer UC800 controller* New generation Trane control platform for chillers Advanced algorithms for the most challenging conditions Maintains efficient and reliable operation Trane patented Compact - High performance - Integrated design - Low charge (CHIL) flooded evaporator* Reduced refrigerant volume Increased efficiency Reduced carbon footprint 11

General specifications General Data for cooling performances RTWF RTWF G RTHF Condenser leaving water temperature (min/max) ( C) +10 / +68 +10 / +85 +10 / +46* Evaporator leaving water temperature (min/max) ( C) -12 / +20-12 / +28-12 / +20 Power supply (V/Ph/Hz) 400/3/50 Refrigerant R134a R1234ze R134a * up to 50 C with capacity limitation depending on model and size RTWF Standard Efficiency (SE) Unit size 275 SE 290 SE 310 SE 330 SE 370 SE 410 SE 450 SE 490 SE Gross Cooling capacity (1) (kw) 938 981 1040 1110 1247 1394 1534 1673 Gross EER (1) 4.95 4.95 4.95 4.97 4.94 4.97 4.97 4.99 Gross ESEER (1) 6.94 6.88 6.83 7.06 6.95 7.48 7.37 7.20 IPLV (2) 7.266 7.243 7.145 7.311 7.243 7.819 7.702 7.525 Net Cooling capacity (3) (kw) 934 977 1036 1106 1242 1388 1528 1667 Net EER (3) 4.73 4.71 4.72 4.74 4.70 4.74 4.74 4.76 Eurovent Energy efficiency class - Cooling B B B B B B B B Net ESEER (3) 5.99 5.87 5.84 6.02 5.90 6.36 6.28 6.19 Number of refrigerant circuits 2 Number of compressors 3 3 3 3 3 4 4 4 Sound Power level (db(a)) 100 100 101 101 101 102 102 102 Weights and dimensions Length (mm) 4754 4754 4784 4784 4784 4774 4774 4774 Width (mm) 1727 1727 1727 1727 1727 1823 1823 1823 Height (mm) 2032 2032 2032 2032 2032 2135 2135 2135 Operating weight (kg) 5276 5273 5456 5511 5574 6945 7025 7109 RTWF High Efficiency (HE) Unit size 275 HE 290 HE 310 HE 330 HE 370 HE 410 HE 450 HE 490 HE Gross Cooling capacity (1) (kw) 963 1008 1072 1140 1272 1429 1569 1714 Gross EER (1) 5.36 5.37 5.34 5.36 5.37 5.38 5.34 5.35 Gross ESEER (1) 7.31 7.27 7.20 7.43 7.33 7.79 7.61 7.42 IPLV (2) 7.666 7.666 7.550 7.719 7.676 8.152 7.954 7.750 Net Cooling capacity (3) (kw) 959 1004 1068 1136 1267 1424 1563 1708 Net EER (3) 5.19 5.18 5.16 5.18 5.18 5.20 5.16 5.18 Eurovent Energy efficiency class - Cooling A A A A A A A A Net ESEER (3) 6.60 6.51 6.45 6.64 6.53 6.97 6.81 6.70 Number of refrigerant circuits 2 Number of compressors 3 3 3 3 3 4 4 4 Sound Power level (db(a)) 100 100 101 101 101 102 102 102 Weights and dimensions Length (mm) 4754 4754 4784 4784 4784 4774 4774 4774 Width (mm) 1727 1727 1727 1727 1727 1823 1823 1823 Height (mm) 2032 2032 2032 2032 2032 2135 2135 2135 Operating weight (kg) 5687 5683 5886 5950 6123 7446 7571 7694 (1) at 12/7 C Entering/Leaving evaporator and 30/35 C Entering/Leaving condenser (2) according to AHRI Standard 550/590, based on TOPSS (Trane Official Selection Software) (3) according to EN14511:2013 12 Water-Cooled Chillers and Water/Water Heat Pumps

General specifications RTWF High Seasonal Efficiency (HSE) Unit size 275 HSE 290 HSE 310 HSE 330 HSE 370 HSE 410 HSE 450 HSE 490 HSE 515 HSE Gross Cooling capacity (1) (kw) 964 1010 1071 1140 1263 1428 1569 1705 1864 Gross EER (1) 5.26 5.27 5.21 5.23 5.24 5.28 5.25 5.25 5.06 Gross ESEER (1) 7.54 7.52 7.52 7.45 7.62 7.76 7.49 7.49 7.68 IPLV (2) 7.829 7.827 7.895 7.831 8.055 8.289 7.987 8.030 7.999 Net Cooling capacity (3) (kw) 961 1007 1068 1136 1258 1424 1563 1699 1857 Net EER (3) 5.10 5.09 5.04 5.06 5.06 5.11 5.07 5.08 4.89 Eurovent Energy efficiency class - Cooling A A B A A A A A B Net ESEER (3) 6.79 6.73 6.74 6.68 6.79 6.94 6.71 6.76 6.75 Number of refrigerant circuits 2 Number of compressors 3 3 3 3 3 4 4 4 4 Sound Power level (db(a)) 100 100 101 101 101 102 102 102 107 Weights and dimensions Length (mm) 4754 4754 4784 4784 4784 4774 4774 4774 4774 Width (mm) 1727 1727 1727 1727 1727 1823 1823 1823 1823 Height (mm) 2032 2032 2032 2032 2032 2135 2135 2135 2135 Operating weight (kg) 5862 5858 6100 6164 6337 7660 7785 7908 7907 RTWF G Standard Efficiency (SE G) Unit size 220 SE G 240 SE G 280 SE G 300 SE G 320 SE G 360 SE G Gross Cooling capacity (1) (kw) 736 789 877 996 1084 1187 Gross EER (1) 4.83 4.80 4.76 4.90 4.83 4.83 Gross ESEER (1) 6.44 6.38 6.51 6.54 6.60 6.53 IPLV (2) 6.505 6.441 6.540 6.654 6.721 6.679 Net Cooling capacity (3) (kw) 733 786 874 993 1080 1183 Net EER (3) 4.67 4.64 4.59 4.75 4.66 4.67 Eurovent Energy efficiency class - Cooling B C C B B B Net ESEER (3) 5.77 5.75 5.77 5.93 5.9 5.89 Number of refrigerant circuits 2 Number of compressors 3 3 3 4 4 4 Sound Power level (db(a)) 96 96 96 97 97 97 Weights and dimensions Length (mm) 4784 4784 4784 4784 4784 4784 Width (mm) 1727 1727 1727 1823 1823 1823 Height (mm) 2032 2032 2032 2135 2135 2135 Operating weight (kg) 5135 5228 5373 6554 6676 6885 (1) at 12/7 C Entering/Leaving evaporator and 30/35 C Entering/Leaving condenser (2) according to AHRI Standard 550/590, based on TOPSS (Trane Official Selection Software) (3) according to EN14511:2013 13

General specifications RTWF G High Efficiency (HE G) Unit size 220 HE G 240 HE G 280 HE G 300 HE G 320 HE G 360 HE G Gross Cooling capacity (1) (kw) 747 802 893 1009 1100 1206 Gross EER (1) 5.01 5.02 4.99 5.16 5.10 5.12 Gross ESEER (1) 6.52 6.50 6.64 6.65 6.77 6.71 IPLV (2) 6.624 6.610 6.757 6.842 6.922 6.873 Net Cooling capacity (3) (kw) 744 799 890 1006 1096 1202 Net EER (3) 4.87 4.89 4.85 5.02 4.96 4.98 Eurovent Energy efficiency class - Cooling B B B B B B Net ESEER (3) 5.99 6.01 6.08 6.17 6.20 6.20 Number of refrigerant circuits 2 Number of compressors 3 3 3 4 4 4 Sound Power level (db(a)) 96 96 96 97 97 97 Weights and dimensions Length (mm) 4784 4784 4784 4784 4784 4784 Width (mm) 1727 1727 1727 1823 1823 1823 Height (mm) 2032 2032 2032 2135 2135 2135 Operating weight (kg) 5517 5610 5804 7007 7129 7353 RTWF G High Seasonal Efficiency (HSE G) Unit size 220 HSE G 240 HSE G 280 HSE G 300 HSE G 320 HSE G 360 HSE G 380 HSE G 420 HSE G Gross Cooling capacity (1) (kw) 747 803 897 1009 1100 1211 1307 1416 Gross EER (1) 4.98 5.02 4.97 5.13 5.09 5.10 4.94 4.84 Gross ESEER (1) 6.70 6.56 6.73 6.66 6.78 6.68 6.84 6.77 IPLV (2) 6.892 6.364 6.885 6.811 6.807 6.868 7.024 6.916 Net Cooling capacity (3) (kw) 745 800 894 1006 1096 1207 1303 1411 Net EER (3) 4.84 4.89 4.83 5.00 4.94 4.97 4.79 4.70 Eurovent Energy efficiency class - Cooling B B B B B B B B Net ESEER (3) 6.14 6.08 6.14 6.18 6.21 6.16 6.23 6.18 Number of refrigerant circuits 2 Number of compressors 3 3 3 4 4 4 4 4 Sound Power level (db(a)) 96 96 96 97 97 97 99 101 Weights and dimensions Length (mm) 4784 4784 4784 4784 4784 4784 4784 4784 Width (mm) 1727 1727 1727 1823 1823 1823 1823 1823 Height (mm) 2032 2032 2032 2135 2135 2135 2135 2135 Operating weight (kg) 5731 5824 6018 7221 7343 7567 7567 7653 (1) at 12/7 C Entering/Leaving evaporator and 30/35 C Entering/Leaving condenser (2) according to AHRI Standard 550/590, based on TOPSS (Trane Official Selection Software) (3) according to EN14511:2013 14 Water-Cooled Chillers and Water/Water Heat Pumps

General specifications RTHF Extra Efficiency (XE) Unit size 330 XE 360 XE 410 XE 460 XE 500 XE 540 XE Gross Cooling capacity (1) (kw) 1179.4 1281.4 1455.3 1586.7 1752.2 1887.5 Gross EER (1) 5.97 5.84 5.86 5.80 5.78 5.78 Gross ESEER (1) 7.39 7.28 7.13 7.28 7.27 7.30 IPLV (2) 7.813 7.727 7.449 7.594 7.561 7.660 Net Cooling capacity (3) (kw) 1177.3 1278.7 1452.3 1582.9 1747.4 1881.6 Net EER (3) 5.85 5.71 5.73 5.66 5.61 5.59 Eurovent Energy efficiency class - Cooling A A A A A A Net ESEER (3) 6.99 6.84 6.69 6.76 6.66 6.63 Number of refrigerant circuits 2 Number of compressors 2 Sound Power level (db(a)) 97 97 98 98 99 99 Weights and dimensions Length (mm) 4585 4585 4585 4585 4585 4585 Width (mm) 1840 1840 1840 1840 1840 1840 Height (mm) 2395 2395 2395 2395 2395 2395 Operating weight (kg) 7350 7450 8590 8590 9630 9680 RTHF Extra Efficiency (XE) Unit size 600 XE 650 XE 700 XE 750 XE 800 XE 840 XE Gross Cooling capacity (1) (kw) 2124.6 2264.2 2450.5 2618.9 2770.2 2924.2 Gross EER (1) 6.28 6.11 6.10 6.05 5.89 5.78 Gross ESEER (1) 7.72 7.64 7.66 7.47 7.32 7.18 IPLV (2) 8.046 8.009 7.991 7.848 7.831 7.610 Net Cooling capacity (3) (kw) 2121.1 2260.0 2445.4 2612.8 2763.2 2916.2 Net EER (3) 6.15 5.98 5.95 5.88 5.72 5.59 Eurovent Energy efficiency class - Cooling A A A A A A Net ESEER (3) 7.26 7.15 7.10 6.90 6.71 6.55 Number of refrigerant circuits 2 Number of compressors 2 Sound Power level (db(a)) 102 103 103 103 103 103 Weights and dimensions Length (mm) 5250 5250 5250 5250 5250 5250 Width (mm) 2090 2090 2090 2090 2090 2090 Height (mm) 2455 2455 2455 2455 2455 2455 Operating weight (kg) 13080 13380 13380 13380 13490 13610 (1) at 12/7 C Entering/Leaving evaporator and 30/35 C Entering/Leaving condenser (2) according to AHRI Standard 550/590, based on TOPSS (Trane Official Selection Software) (3) according to EN14511:2013 15

General specifications RTHF High Seasonal Efficiency (HSE) Unit size 330 HSE 360 HSE 410 HSE 460 HSE 500 HSE 540 HSE 590 HSE 640 HSE Gross Cooling capacity (1) (kw) 1173.8 1275.2 1448.7 1580.4 1743.4 1878.0 2059.3 2233.5 Gross EER (1) 5.78 5.66 5.67 5.63 5.6 5.6 5.4 5.21 Gross ESEER (1) 8.65 8.65 8.54 8.78 8.71 8.91 8.71 8.71 IPLV (2) 8.947 9.204 9.085 9.228 9.204 9.253 9.326 9.109 Net Cooling capacity (3) (kw) 1171.7 1272.6 1445.7 1576.7 1738.7 1872.2 2052.0 2224.4 Net EER (3) 5.67 5.54 5.55 5.49 5.45 5.42 5.21 5.01 Eurovent Energy efficiency class - Cooling A A A A A A A B Net ESEER (3) 8.08 7.99 7.89 8.01 7.84 7.9 7.59 7.44 Number of refrigerant circuits 2 Number of compressors 2 Sound Power level (db(a)) 97 97 98 98 99 99 102 104 Weights and dimensions Length (mm) 4585 4585 4585 4585 4585 4585 4585 4585 Width (mm) 1940 1940 1940 1940 1940 1940 1940 1940 Height (mm) 2395 2395 2395 2395 2395 2395 2395 2395 Operating weight (kg) 7520 7620 8820 8820 9920 9970 9960 9960 RTHF High Seasonal Efficiency (HSE) Unit size 600 HSE 650 HSE 700 HSE 750 HSE 800 HSE 840 HSE 900 HSE Gross Cooling capacity (1) (kw) 2119.0 2254.9 2440.5 2608.7 2759.8 2911.4 3178.0 Gross EER (1) 6.16 5.98 5.97 5.92 5.77 5.65 5.4 Gross ESEER (1) 9.26 9.16 9.12 9.23 8.98 8.65 8.3 IPLV (2) 9.477 9.633 9.686 9.740 9.503 9.180 9 Net Cooling capacity (3) (kw) 2115.6 2250.8 2435.4 2602.7 2752.9 2903.5 3165 Net EER (3) 6.04 5.85 5.83 5.76 5.61 5.47 5.2 Eurovent Energy efficiency class - Cooling A A A A A A A Net ESEER (3) 8.6 8.45 8.32 8.33 8.04 7.71 7.4 Number of refrigerant circuits 2 Number of compressors 2 Sound Power level (db(a)) 102 103 103 103 103 103 103 Weights and dimensions Length (mm) 5250 5250 5250 5250 5250 5250 5250 Width (mm) 2090 2090 2090 2090 2090 2090 2090 Height (mm) 2455 2455 2455 2455 2455 2455 2455 Operating weight (kg) 13440 13740 13740 13740 13850 13970 13970 (1) at 12/7 C Entering/Leaving evaporator and 30/35 C Entering/Leaving condenser (2) according to AHRI Standard 550/590, based on TOPSS (Trane Official Selection Software) (3) according to EN14511:2013 16 Water-Cooled Chillers and Water/Water Heat Pumps

General specifications General Data for heating performances RTWF Standard Efficiency (SE) Unit size 275 SE 290 SE 310 SE 330 SE 370 SE 410 SE 450 SE 490 SE Air conditioning application (1) Gross Heating capacity (kw) 1033 1083 1146 1212 1343 1534 1665 1797 Gross COP 4.57 4.55 4.56 4.59 4.60 4.57 4.60 4.63 Net Heating capacity (2) (kw) 1041 1092 1155 1222 1354 1546 1679 1811 Net COP (2) 4.37 4.34 4.35 4.38 4.39 4.39 4.39 4.43 Eurovent Energy efficiency class - Heating B B B B B B B B Medium temperature application (3) Gross Heating capacity (kw) 969 1016 1076 1139 1263 1439 1565 1689 Gross COP 3.69 3.68 3.69 3.72 3.73 3.70 3.73 3.76 Net Heating capacity (2) (kw) 974.8 1022.6 1082.7 1146.1 1271.2 1448 1574.8 1700 Net COP (2) 3.61 3.6 3.61 3.64 3.65 3.62 3.65 3.68 RTWF High Efficiency (HE) Unit size 275 HE 290 HE 310 HE 330 HE 370 HE 410 HE 450 HE 490 HE Air conditioning application (1) Gross Heating capacity (kw) 1048 1099 1166 1230 1354 1553 1686 1820 Gross COP 4.79 4.77 4.76 4.80 4.86 4.78 4.81 4.85 Net Heating capacity (2) (kw) 1054 1106 1174 1237 1361.3 1562 1695 1831 Net COP (2) 4.62 4.59 4.6 4.62 4.65 4.60 4.72 4.68 Eurovent Energy efficiency class - Heating A A A A A A A A Medium temperature application (3) Gross Heating capacity (kw) - 1035 1098 1159-1462 1588 1716 Gross COP - 3.88 3.87 3.90-3.89 3.91 3.95 Net Heating capacity (2) (kw) - 1041 1105 1166-1470 1597 1725 Net COP (2) - 3.81 3.81 3.83-3.82 3.84 3.88 RTWF High Seasonal Efficiency (HSE) Unit size 275 HSE 290 HSE 310 HSE 330 HSE 370 HSE 410 HSE 450 HSE 490 HSE 515 HSE Air conditioning application (1) Gross Heating capacity (kw) 1053 1107 1175 1238 1381 1561 1694 1848 2024 Gross COP 4.73 4.72 4.69 4.73 4.75 4.73 4.76 4.77 4.68 Net Heating capacity (2) (kw) 1060 1113 1183 1246 1389 1571 1704 1858 2037 Net COP (2) 4.57 4.54 4.53 4.56 4.55 4.55 4.58 4.60 4.50 Eurovent Energy efficiency class - Heating A A A A A A A A A Medium temperature application (3) Gross Heating capacity (kw) - 1044 1109 1170-1472 1599 1744 1914 Gross COP - 3.83 3.81 3.84-3.84 3.87 3.88 3.83 Net Heating capacity (2) (kw) - 1050 1115 1176-1481 1608 1754 1925 Net COP (2) - 3.76 3.75 3.77-3.70 3.8 3.81 3.76 (1) at 10/7 C Entering/Leaving evaporator and 40/45 C Entering/Leaving condenser (2) according to EN14511:2013 (3) at 10/7 C Entering/Leaving evaporator and 47/55 C Entering/Leaving condenser 17

General specifications RTWF G Standard Efficiency (SE G) Unit size 220 SE G 240 SE G 280 SE G 300 SE G 320 SE G 360 SE G Air conditioning application (1) Gross Heating capacity (kw) 822 884 983 1112 1211 1328 Gross COP 4.73 4.70 4.67 4.78 4.72 4.73 Net Heating capacity (2) (kw) 824 886 986 1115 1214 1331 Net COP (2) 4.51 4.51 4.46 4.58 4.50 4.53 Eurovent Energy efficiency class - Heating A A A A A A Medium temperature application (3) Gross Heating capacity (kw) 779 836 932 1051 1146 1256 Gross COP 3.86 3.84 3.82 3.90 3.85 3.87 Net Heating capacity (2) (kw) 780 837 933 1052 1147 1257 Net COP (2) 3.76 3.75 3.72 3.81 3.75 3.78 High temperature application (4) Gross Heating capacity (kw) - - - - 1077 1178 Gross COP - - - - 3.09 3.10 Net Heating capacity (2) (kw) - - - - 1078 1179 Net COP (2) - - - - 3.04 3.06 RTWF G High Efficiency (HE G) Unit size 220 HE G 240 HE G 280 HE G 300 HE G 320 HE G 360 HE G Air conditioning application (1) Gross Heating capacity (kw) 830 892 993 1114 1220 1335 Gross COP 4.88 4.90 4.88 5.00 4.97 4.98 Net Heating capacity (2) (kw) 831 893 994 1116 1221 1337 Net COP (2) 4.67 4.71 4.66 4.80 4.74 4.77 Eurovent Energy efficiency class - Heating A A A A A A Medium temperature application (3)(5) Gross Heating capacity (kw) 791 848 947 1063 1162 1271 Gross COP 4.03 4.04 4.03 4.11 4.09 4.10 Net Heating capacity (2) (kw) 793 850 949 1065 1164 1274 Net COP (2) 3.90 3.92 3.90 3.99 3.95 3.97 High temperature application (4)(5) Gross Heating capacity (kw) 749 802 898 1004 1100 1205 Gross COP 3.23 3.23 3.23 3.28 3.27 3.28 Net Heating capacity (2) (kw) 750 803 899 1004 1101 1207 Net COP (2) 3.17 3.18 3.17 3.22 3.20 3.23 (1) at 10/7 C Entering/Leaving evaporator and 40/45 C Entering/Leaving condenser (2) according to EN14511:2013 (3) at 10/7 C Entering/Leaving evaporator and 47/55 C Entering/Leaving condenser 18 Water-Cooled Chillers and Water/Water Heat Pumps

General specifications RTWF G High Seasonal Efficiency (HSE G) Unit size 220 HSE G 240 HSE G 280 HSE G 300 HSE G 320 HSE G 360 HSE G 380 HSE G 420 HSE G Air conditioning application (1) Gross Heating capacity (kw) 831 893 998 1115 1220 1341 1460 1588 Gross COP 4.89 4.92 4.85 5.01 4.97 4.96 4.85 4.78 Net Heating capacity (2) (kw) 832 894 999 1116 1222 1343 1462 1590 Net COP (2) 4.67 4.73 4.64 4.80 4.75 4.76 4.63 4.58 Eurovent Energy efficiency class - Heating A A A A A A A A Medium temperature application (3)(5) Gross Heating capacity (kw) 794 849 953 1063 1165 1278 1397 1516 Gross COP 4.04 4.05 4.00 4.12 4.10 4.08 4.01 3.96 Net Heating capacity (2) (kw) 795 850 954 1065 1167 1280 1400 1520 Net COP (2) 3.91 3.94 3.87 3.99 3.96 3.96 3.88 3.83 High temperature application (4)(5) Gross Heating capacity (kw) 749 802 896 1006 1099 1203 1323 1436 Gross COP 3.22 3.24 3.18 3.28 3.27 3.25 3.21 3.17 Net Heating capacity (2) (kw) 749 803 897 1007 1101 1204 1324 1438 Net COP (2) 3.16 3.18 3.13 3.23 3.20 3.19 3.15 3.11 (1) at 10/7 C Entering/Leaving evaporator and 40/45 C Entering/Leaving condenser (2) according to EN14511:2013 (3) at 10/7 C Entering/Leaving evaporator and 47/55 C Entering/Leaving condenser 19

The Trane advantage Trane is recognized as a world leader with over 100 years of experience in creating and sustaining safe, comfortable and energy efficient environments while improving the performance of buildings and processes around the world. Trane innovative solutions optimize indoor environments with the broadest portfolio of energy efficient heating, ventilating and air conditioning systems, building services, parts support and advanced controls in the industry. To ensure your equipment continues to work at its optimum, throughout the life of the building, Trane provides a full range of service solutions, combined with in-house expertise and the most extensive service and support network in the industry. And with Trane s extensive rental fleet all your temporary cooling and heating needs are served: we provide continuous cooling or heating during equipment changeouts or supplemental supply for those times when your cooling loads exceed your current system s capacity. For more information: www.trane-chiller-rental.eu Ingersoll Rand recognition For the fifth consecutive year, Ingersoll Rand has been recognized as one of the World s Most Admired Companies according to FORTUNE Magazine. What s more, we ranked second in our Industrial Machinery category up two places from the previous year. Ingersoll Rand was recognized at the 2016 Climate Leadership Conference for its refrigerant phase-out efforts by the US EPA, its greenhouse gas emissions reduction goal of 35% by 2020 and its commitment to reduce the climate impact of the refrigerants used in its products by 50% by 2020. Trane is a brand of Ingersoll Rand. Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Ingersoll Rand, Trane, Thermo King and Club Car work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. trane.eu ingersollrand.com We are committed to using environmentally conscious print practices that reduce waste. 2017 Trane All rights reserved RLC-SLB040-GB September 2017