POSSIBLE TREATMENT STRATEGIES 1/3 From Archibald Johnston Mansion Stabilization Study - Recommendations

Similar documents
Historic Wood Windows

Chapter 2 Understanding The Problem

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

Lift & Slide door installation instructions

Design Guidelines for Construction and Renovation in the Longmeadow Historic District

INSPECTION TYPE EIFS system, Visual, Tramex & Delmhorst probe moisture readings

BIDDING SHEET CHECKLIST--SUBCONTRACTORS AND SUPPLIERS SUBCONTRACTOR/ PHONE DATES SUPPLIER NAME: CALLED BID. Sample

APPLICATION. Application filing fee $10.00

The NWX Prairie Style

City of Port Huron Michigan. Historic District Guidelines and Application

r e s i d e n t i a l o u t s i d e v i l l a g e c e n t e r

REHABILITATION OF HISTORIC RESOURCES

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

NEW YORK STATE MAIN STREET PROGRAM BEFORE & AFTER

Historic Preservation Commission

City of Richmond Zoning Ordinance Page 12-1

STANDARD FOR REHABILITATION THE SECRETARY OF THE INTERIOR'S STANDARDS FOR REHABILITATION AND GUIDELINES FOR REHABILITATING HISTORIC BUILDINGS

DESIGN GUIDELINES COMMERCIAL BUILDING FACADES. Provided by Community Development Program Of Beaver County

Pella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...

Senturion TM III Wall System

NEW CONSTRUCTION ADDENDUM TO COA APPLICATION

MEMORANDUM. DEVELOPMENT REVIEW BOARD Design Review Application #DR Dorset Street

Weatherproofing & Sealing Systems

LOGAN SCHOOL SCHOOL WITHOUT WALLS AT LOGAN

11.0 Commercial Infill

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Building Inspection Report

CLG Commissioner Training

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

CERTIFICATE OF APPROPRIATENESS APPLICATION

School Without Walls

Rockland Library Assessment Executive Summary

Weep Valves Stucco Wire Mesh Reinforcement Weather Resistive Barrier Sheathing Insulation Framing

Compliance Department RESEARCH COMPLIANCE MEMORANDUM

WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

The Secretary of the Interior's Standards for Rehabilitation and Guidelines for Rehabilitating Historic Buildings

FMA / AAMA / WDMA Installation Committee Update. Jim Katsaros / DuPont Building Innovations FMA Installation Committee April 24, 2012

Row House Henz-Noirfalise in Eupen, Belgium

STUCCO FAILURES and REMEDIATION Roger G. Morse AIA

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

GUIDELINES FOR PLANNING HISTORIC PRESERVATION TAX CREDIT PROJECTS

GREEN PASTURES - RESIDENTIAL ARCHITECTURAL REVIEW GUIDELINES

BUILDING YOUR HOME the right way

The conditions, recommendations, suggestions contained herein are the result of a visual inspection as of this date.

Neighborhood Traditional Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Residential Design Standards Draft 9 August 2013

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera

MID-RISE DESIGN & CONSTRUCTION

Facade Grant Program

Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI.

NEW CENTURY COMMUNITY PROGRAM HISTORIC BUILDINGS RESTORATION GRANTS

SURESILL WATER MANAGEMENT GUIDE

Vienna Historic Preservation Commission Vienna Central Historic District Design Guidelines

EC The Effective Detective : Finding Energy Savings at Home

2018 British Columbia Building Code Public Review of Proposed Changes

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

GETTING STARTED... 2 YOUR LIST OF PRODUCTS... 2 WHAT THAT LIST BECOMES... 2 PRODUCTS CREATED AS ENVISIONEER ELEMENTS... 3

Ohio s Historic Courthouses

Proposal Request (attachment to AIA Form G709)

CITY OF NOVI. Police Department

Building Envelope Systems Exam Learning Objectives

CARL E. SCHLUTER ELEMENTARY SCHOOL

Forest Hill Home Owners, Inc. Application for Exterior Alterations and Additions

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

STRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Residential Uses in the Historic Village Core

Exterior Stucco and Siding Installation

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

WATERPROOFING TAMKOWATERPROOFING.COM

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Marbella Isles Homeowners Association, Inc.

Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

Slab edge insulation is one of

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

J. Paul Guyer, P.E., R.A.

Proper Installation of Insulated Metal Wall Panels

3275 & 3275U, 3285 & 3285U Vertical Sliding, Double-Hung Windows

Mobile Light No HABS No. ALA-780 (Middle Bay Light) Middle of Mobile Bay ' Mobile County ' Alabama HABS ALA, U9-M0BI, 116-

Chapter UNIFORM CODES FOR CONSTRUCTION BUILDING CODE

Seal Harbor Development 1 Nagog Park Acton, MA 01720

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

Design Guidelines To Enhance the Downtown Historical District. Developed by the Van Wert Community Main Street Design Committee June 26, 2007

Vertigo Cladding Board


THE ULTIMATE HIGH PERFORMANCE NEW CONSTRUCTION WINDOWS AND PATIO DOORS

Architectural Guidelines

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

SGN+A Planning Architecture Landscape Architecture

NARI National 2018 CotY Program Categories Please read category descriptions carefully as some criteria have changed.

MULTI-FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

Transcription:

POSSIBLE TREATMENT STRATEGIES 1/3 Minimal short-term stabilization The plan for minimal short-term stabilization represents all of the recommended items to be completed if the Township only wishes to buy the building time. Many of these items are not included in the subsequent plans for full stabilization, because roof,, and facade replacement would eliminate the need for such repairs. Recommendations Minimal short term stabilization scope of 1 231 LF $10,890 IA Ridge flashing Provide continuous copper metal ridge Replace flat roof areas with EPDM; repair roof edge IB Repair metal roof accessories flashing, gutter lining, soffit and modillions 1330 LF $26,620 IC Line gutter in EPDM Line the existing copper gutter in EPDM 300 LF $14,520 Kill vegetation and temporarily cap s with ID Temporary repair EPDM. 4 CHIMNEYS $7,260 Individually or by area, replace damaged and failing IF Shingle replacement slate shingles in kind 50 SHINGLES $3,025 Providing sealant at seams along brick and wood in IIA Sealant at trim contact with stucco 3000 LF $38,115 Providing flashing at stucco seams along brick grade IIB Flashing along brick course 430 LF $7,805 IID Repaint exterior Stucco; wood trim; sun ; and soffit. 8 $99,958 IIG Secure IIIA Glass replacement Replace broken glass 3 $1,500 27 $14,250 Total estimated cost (not phased)= $262,978 $262,978

POSSIBLE TREATMENT STRATEGIES 2/3 Full stabilization (Economical) It may be determined that the funds are available to complete a full stabilization of the building, but the emphasis is on securing the envelope economically rather than historic continuity. This plan would be desirable if the Township determined that the higher level of historic and aesthetic quality would not be worth the extra costs. Recommendations Full stabilization (Economical) 1 Entire roof replacement with composite shingle system; where, patch sheathing, reinforce IH New composite roof structure, and replace flashing IE Chimney repair scope of 6100 SF $217,800 $14,520 / $261,360 * 2 IIE IIG Re stucco entire facade Secure ; provide flashing $162,485 $177,109 3 IIIA Glass replacement Replace broken glass 3 $1,500 27 $14,250 IID Repaint exterior wood Wood trim; sun ; and soffit. 2000 SF $60,000 IIIF Shutter restoration 85 SHUTTERS $33,275 Total estimated cost (not phased)= $563,120 * $767,590 $139,275 $164,345 *$343,745 *$405,620 IIID IIIE Window and door replacement Provide new custom windows and doors * Adjusted cost for new window and door replacement $220,220 * shown represents 3-years from the previous phase: 2 reflects a 9% increase, 3 reflects an 18% increase.

POSSIBLE TREATMENT STRATEGIES 3/3 Full stabilization (Historically preferable) Due to the high historic value and architectural qualities of the Archibald Johnston mansion, it is recommended to respect the original characteristics and to restore or replace-in-kind when possible. This would be the desired course if the Township has any plans to showcase the building in some historic capacity. Regardless of its future use, the mansion will be a prominent feature of the park. Recommendations Full stabilization (Historically preferable) 1 Entire roof replacement with new slate roof; where, patch sheathing, reinforce structure, and II New slate roof replace flashing IE Chimney repair scope of 6100 SF $272,250 $14,520.00 / $315,810 * 2 IIE IIG Re stucco entire facade Secure ; provide flashing $162,485 $177,109 3 IID Repaint exterior wood Wood trim; sun ; and soffit. 2000 SF $60,000 27 $14,250 Re glaze and fix all windows and counterweights as ; strip and paint all sashes, muntins, jambs, $68,820 IIIB Restore all windows and doors headers, sills, and trim. 85 SHUTTERS $33,275 IIIF Shutter restoration Total estimated cost (not phased)= $684,890 $206,595 $243,782 * shown represents 3-years from the previous phase: 2 reflects a 9% increase, 3 reflects an 18% increase.

TREATMENT SUMMARY From Archibald Johnston Mansion Stabilization Study IA Ridge flashing Provide continuous copper metal ridge 231 LF $10,890 Repair metal roof Replace flat roof areas with EPDM; repair roof edge 1330 LF $26,620 IB accessories flashing, gutter lining, soffit and modillions IC Line gutter in EPDM Line the existing copper gutter in EPDM 300 LF $14,520 Kill vegetation and temporarily cap s with 4 $7,260 ID Temporary repair EPDM. CHIMNEYS IE IF IG IH Chimney repair Shingle replacement New asphalt roof New composite roof Roof Treatments Individually or by area, replace damaged and failing slate shingles in kind Entire roof replacement with asphalt shingle system; where, patch sheathing, reinforce structure, and replace flashing Entire roof replacement with composite shingle system; where, patch sheathing, reinforce structure, and replace flashing 50 SHINGLES $14,520.00 / $3,025 6100 SF $108,900 6100 SF $217,800 II New slate roof Entire roof replacement with new slate roof; where, patch sheathing, reinforce structure, and replace flashing 6100 SF $272,250 Facade Treatments Providing sealant at seams along brick and wood in IIA Sealant at trim contact with stucco 3000 LF $38,115 Providing flashing at stucco seams along brick grade IIB Flashing along brick course 430 LF $7,805 Provide compatible stucco mixture and replace lath and 1520 SF REPLACEMENT Patch and resurface stucco where ; provide new finish coat on all (to be REQUIRED IIC stucco existing stucco patched) IID Repaint exterior Stucco; wood trim; sun ; and soffit. 8 $99,958 Repaint exterior wood Wood features only; ie. trim, sun, soffit, etc. $60,000 IIE Re stucco entire facade ; provide flashing Replace stucco with alternative material: Replace entire stucco facade with a synthetic stucco IIF Synthentic stucco system, providing flashing where IIG Secure entry IIIA Glass replacement Replace broken glass IIIB IIIC IIID IIIE IIIF Restore all windows and doors Add missing storm windows and doors New custom storm windows and doors Window and door replacement Shutter restoration Openings' Treatments Re glaze and fix all windows and counterweights as ; strip and paint all sashes, muntins, jambs, headers, sills, and trim. Install storm windows on unprotected windows and Provide compatible storm windows and doors of custom size Provide new custom windows and doors 3 27 86 85 SHUTTERS $1,500 $68,820 $14,250 $44,500 $220,220 $33,275

ADDITIONAL INFORMATION Ventilation needs Reference Preservation Brief 31: Mothballing Historic Buildings After securing the exterior of the building, ensuring proper ventilation of the interior will be vital when using modern technologies. It is likely, however, that passive methods will be sufficient if carried out properly. Generally, the building will require: in winter, 1 air exchange per hour; 5% of openings to be louvered in summer, 2 to 3 air exchanges per hour; 10% of openings to be louvered Locate louvered openings on every floor, in a manner to facilitate cross-ventilation, with interior doors ajar Electric fans can be utilized to facilitate ventilation during humid periods Monitoring devices can be utilized to record interior humidity levels, to ensure adequate levels National Register Status benefits Reference National Register of Historic Places Fact Sheet Criteria for eligibility on the National Register: A. be associated with events that have made a significant contribution to the broad patterns of our history; or B. be associated with the lives of persons significant in our past; or C. embody the distinctive characteristics of a type, period, or method of construction, or represent the of a master, or possess high artistic values, or represent a significant a distinguishable entity whose components may lack individual distinction; or D. have yielded or may be likely to yield information important in history or prehistory. Listing on the National Register has the following benefits: 1. recognition that a property is of significance to the nation, the state, or local community; 2. eligibility for federal tax incentives for income-producing buildings; 3. state and federal preservation grants for planning and rehabilitation of buildings owned by not-forprofit organizations and local governments; 4. consideration in the planning for state and federal projects or projects that are assisted by state or federal agencies. Total window replacement vs. storm windows Reference Saving Windows, Saving Money: Evaluating the Energy Performance of Window Retrofit and Replacement Window upgrade alternatives to new high performance replacement windows include: weather stripping applying an interior surface film installing insulating cellular shades installing exterior storm windows installing interior window panels Using a combination of methods, the energy savings of the alternatives are competitive with new replacement windows, and have the potential for a higher return on investment.