Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Similar documents
FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

FLUXUS F/G601 and F/G608

OPTIMASS 7400 Technical Datasheet

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

Pressure transducers DMU 02 Vario (flush)

VERIS Accelabar. Superior Flow Measurement Accuracy

FLUXUS F601. Portable, quick and reliable. Clamp-on ultrasonic flow meter. Measure from outside what's flowing inside

Target Inline Flowmeter

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

Digital E3 Modulevel Liquid Level Displacer Transmitter

Red Eye Multiphase Water-Cut Meter

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

Rosemount 405 Compact Orifice Primary Element

Industrial Flowmeters

8 stream capability with dual mode (H 2 S & total Sulphur)

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

PORTABLE COATING THICKNESS GAUGE

Liquid level switch BW 17

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

MAGFLO. Flow metering based on electromagnetic technology. For value-adding performance you can count on. FLOW DIVISION Simply Better

Electromagnetic flowmeter ProcessMaster FEP300/500 The first choice for the process industry

Volume Flow and Gas Flow Measuring Devices

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

Multiphase Flow Measurement. Multiphase Flow Meter Wet Gas Meter Multiphase Wet Gas Flow Meter Well Testing Service

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

heliflu tm The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

Moisture analyzers (moisture meters) FIZEPR-SW100

Digital innovation in ultrasonic flow SITRANS FS230. siemens.com/fs230

HELIFLU TM TZN. The Dedicated Turbine Flowmeter for Custody Transfer Measurement. Proven Performance. Main Applications

DIVA flowmeter. for saturated steam flow measurement

Long-term Evaluation of Ultrasonic Flowmeters

February 5, 2013 Roy Ratcliffe, President RM Controls, Inc.

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:

Proven Flow Measurement Solutions for the Oil and Gas Industry

Alpha VSRD Multiphase Flowmeter

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice

Gilflo flowmeters. for steam, liquids and gases

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

Handheld Transit-Time Ultrasonic Flowmeter

ON-LINE OIL TRACE MONITOR

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

heliflu tm The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

IV CUT MONITOR DUMPSTAR

Integrated Sampling Solutions

Engineered Hot Water Systems. For your specific requirements

Manage flow and stay in control of your budget

Vortex EX DELTA lowmeter Technical Specifications

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

Sensor unit MC2 for toxic gases and oxygen with analog output

NUFLO Liquid Turbine Flow Meters

Flow solutions for LNG metering. Helene Casellas Business Development Manager Oil & Gas Flow Europe

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Process Analyzer. UV Oil in Water Analyzer Model W-800. Credible Solutions for the Oil and Gas Industry

ASME PTC Flow Measurement

VortexMaster and SwirlMaster Natural gas measurement in power plants, boilers and incinerators

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

Oil on Water Monitor Model. FLUCOmat (FLU 103) Non Contact Detection of: Mineral oils Synthetic oils Oil- Emulsions Free Hydrocarbons

FLUXUS. Non-Invasive Liquid Flow Measurement. Measure from outside what s flowing inside

European MID Directive for Custody Transfer Measuring Instruments Proven, certified technology for Fiscal & Custody transfer applications

ProFoss for in-line process analysis of dairy powder

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

General Discussion of Corrosion Monitoring Considerations in Pipeline Design

Cleaning Validation PRODUCT OVERVIEW

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

Analytical Instruments

AUSTRALIA S LARGEST WEIGHBRIDGE MANUFACTURER!

Superior Performance. Vortex Shedding Products

World s first LNG research and calibration facility

Flow Measurement SITRANS F M

AP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series

F Series Flow Meter F300. User Manual

Self Contained Weighing Module

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

TVA Target Variable Area Flowmeter

Reduce costs, improve well testing, and maximize production

AS950 ALL-WEATHER REFRIGERATED SAMPLER

Transcription:

GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available for cryogenic liquids. Fully welded construction with no moving parts. Ultrasonic transducers protected from cryogenic temperatures using Bundle Waveguide Technology. Applications Liquefied Natural Gas (LNG) Cryogenic fluid allocation Custody transfer Marine Cargo Verification Full bore design, zero pressure drop. High accuracy to overcome limitations of tank level gauging. Robust Path Configuration through extensive use of CFD (Computational Fluid Dynamics).

Cryogenic Flow Measurement from GE GE introduces Sentinel LNG, a new addition to our series of advanced ultrasonic flowmeters. Sentinel LNG demonstrates new levels of performance, reacts to changes in flow rate with incredible speed and accuracy, and is based on proven technologies. Sentinel LNG extends the use of ultrasonic technology into cryogenic applications for measuring liquefied natural gas (LNG) with unbeatable performance, reliability and safety. Sentinel LNG Design CFD allowed us to test different ultrasonic path configurations under highly turbulent flow regimes that are typically seen in LNG measurements. Only after CFD simulation provided the optimal path configuration, Sentinel LNG was tested in a calibration loop to prove the CFD results. X The design philosophy behind Sentinel LNG was simple; building a reliable flow meter to overcome the accuracy limitation of LNG tank level measurement. Sentinel LNG is an ultrasonic flowmeter with a fully welded construction that has no moving parts. The acoustic transducers are placed outside the cryogenic liquid to avoid any longterm degradation due to temperature. The design is full bore; as a result, the pressure drop over the meter is simply equal to a section of pipe with the same length. Z = -0.2265(m) -0.0802-0.0665 0 0.0665 0.0802 0.2265 CFD Simulation of Acoustic Port Effects Under Highly Turbulent Flow Limitations of Tank Level Gauging Z Advanced Electronics Sentinel LNG measures flow using advanced digitalsignal processing and improved algorithms that enable the meter to measure flow with an exceptional response speed. Sentinel LNG packs significant power in a simple package available with several standard output options. Customer wiring is kept in a separate location for safety. It can be mounted on the flowcell section or can be mounted up to 50 ft (15 m) away. Full access to cable connections is still possible even when mounted directly to a wall. Full diagnostic capability can be checked locally on the display, remotely by PC or outputted via a variety of digital interfaces for continuous verification and preventative maintenance. Robust Path Configuration Before Sentinel LNG was ever tested on a calibration loop, the meter was already extensively tested in the virtual world. Computational Fluid Dynamics (CFD) was used to simulate different path configurations under different flow scenarios. To give an idea of the level of detail we went into, the CFD was done with the same set-up that GE Aviation uses to model the flow in aircraft engines. The result of the CFD is filed as a GE patent and is reflected in the choice of Robust Path Configuration. Measuring the volume of LNG in a tank is more than just measuring the level of the (boiling) LNG inside the tank. The temperature in the tank might not be constant, causing density variation. Corrections need to be made for tank expansion caused by the weight of the LNG inside. In case of level measurement on a ship, a pitch or even movement because of wave motion may need to be compensated for. By making a direct volume measurement, Sentinel LNG overcomes all these additional sources of uncertainty. Bundle Waveguide Technology The Bundle Waveguide Technology acts as a buffer rod between the transducer and the flowing cryogenic liquid. These buffer assemblies use waveguide bundles to efficiently concentrate a greater amount of transducer ultrasonic signal into the process. At the same time, the bundles act as a buffer to protect the transducer from the cryogenic temperatures. The buffer is an all-metal construction with no moving parts. As a result, transducers can be safely removed from service without opening the pipeline. An insertion mechanism or expensive valves are not required.

Water Calibration The Sentinel LNG meter is equipped with time tested correction curves that can translate a water calibration into high accuracy performance at cryogenic temperatures. Active Temperature Compensation Ultrasonic flowmeters use transit time to determine the liquid or gas flow in a pipeline. Measured transit time consists not only of the time the ultrasonic signal spends in a fluid; it also consists of a portion of dead time, being the time that the electrical signal is converted into an acoustical signal and the time the acoustic signal travels inside the transducer. To allow for the utmost accuracy, Sentinel LNG uses pulse echo to actively measure the dead time. By sending a pulse and measuring its reflection at the end of the transducer, the dead time is measured in real time rather then using a preset value. As a result of this GE invention, Sentinel LNG guarantees a flow measurement of the highest accuracy. Advanced Electronics Sentinel LNG has advanced digital signal processors that pack significant power in a simple package. Several output options are standard. The electronics can be mounted on the flowcell section or up to 300 feet away. Cable connections can easily be accessed, even when the meter has been mounted to a wall. HART is standard on all meters. Local diagnostics can be done via magnetic contacts through the glass, or by using the USB connection and our PanaView software. Tw ( dead time in buffer) Tf (time in fluid) PanaView for Diagnostics PanaView software facilitates communication between a PC and the Sentinel LNG flowmeter. This software monitors the Sentinel flowmeter to provide a secure and comprehensive check on the meter configuration with a full audit trail. It also allows live flow readings and tracking of flow diagnostics. Buffers BWT transducers Active Flow Compensation Fluctuations in temperature, especially in cryogenic applications, can affect flow accuracy. These fluctuations change the characteristics of the fluid traveling through the pipe, flowcell dimensions and the acoustic characteristics of the flowmeter. Based on a live temperature input, Sentinel LNG monitors the application temperature and calculates the changes in the flowcell dimensions. The transducer s transit time signal changes relative to temperature. Sentinel LNG s SEN898 electronics actively measure the transducer transit time signal to ensure accurate overall transit time measurement. The meter automatically and continuously makes adjustments as the application and ambient conditions change to ensure accurate measurement without user intervention. Example of PanaView Display

Dimensions and Weights C A Weights are based on stainless steel. Dimensions and weights in English units Diameter Flange A (in) C (in) Weight (lb) 4 150# 20 23.49 150 300# 20 23.99 178 600# 20 24.36 202 6 150# 22 25.76 211 300# 24 26.51 268 600# 26 27.26 341 8 150# 26 27.59 271 300# 28 28.34 346 600# 30 29.09 457 10 150# 28 29.84 371 300# 30 30.59 492 600# 32 31.84 746 12 150# 30 32.59 483 300# 32 33.34 688 600# 36 34.09 967 14 150# 36 34.09 798 300# 38 35.09 1090 600# 40 35.46 1352 16 150# 38 36.84 989 300# 40 37.84 1361 600# 42 38.59 1788 18 150# 38 37.84 1067 300# 40 39.34 1542 600# 44 39.96 2097 20 150# 46 41.25 1438 300# 48 42.75 2141 600# 50 43.50 2847 24 150# 48 44.59 2010 300# 50 46.59 2976 600# 52 47.09 3985 Dimensions and weights in metric units Diameter Flange A (mm) C (mm) Weight (kg) 4 150# 508 597 68 300# 508 609 81 600# 508 619 92 6 150# 559 654 96 300# 610 673 121 600# 660 692 155 8 150# 660 701 123 300# 711 720 157 600# 762 739 207 10 150# 711 758 168 300# 762 777 223 600# 813 809 339 12 150# 762 828 219 300# 813 847 312 600# 914 866 438 14 150# 914 866 362 300# 965 891 494 600# 1016 901 613 16 150# 965 936 463 300# 1016 961 618 600# 1067 980 811 18 150# 965 961 484 300# 1016 999 700 600# 1118 1015 951 20 150# 1168 1048 646 300# 1219 1086 962 600# 1270 1105 1280 24 150# 1219 1133 912 300# 1270 1183 1350 600# 1321 1196 1808

Specifications Performance Fluid Types Liquid hydrocarbons Flow Measurement Correlation transit time mode Accuracy < ± 0.25% of measured volume for flow rates between 2 and 30 ft/s (0.5 and 10 m/s) Repeatability <±0.02% Zero Stability < 0.007 ft/s (0.002 m/s) Process Temperature -200 to +120 C (-328 to 248 F) Ambient Temperature -40 to +60 C (-40 to 140 F) Storage Temperature -40 to +80 C (-40 to +176 F) Meter Body Path Configuration Four-path Robust Path Configuration Meter Body Materials Stainless steel A182, Gr 304/304L Stainless steel A182, Gr 316/316L Others on request. Pipe Sizes 4 in (100 mm) to 36 in (900 mm) Others on request. Flange Ratings 150 # 300 # Others on request. Pipe Schedules 10S 40S STD Others on request. PED Compliance PED Cat III, module H Installation Requirement Meter must be installed with 20D straight piping upstream and 5D straight piping downstream. Inlet and outlet piping ID must meet meter ID. Pressure, temperature and density connections must be located in the downstream piping. The 20D upstream piping must be free of any nozzles that could disturb the flow profile. Electronics Electronics Enclosure Material Epoxy coated aluminium Dimensions Weight 25 lb (11.5 kg) Size (lxhxd): 13 x11x 9 in (33x27x23 cm) Environmental Protection IP66 Power Supply 100 to 240 VAC 12 to 32 VDC Power Consumption < 20 watt Display High contrast 128 x 64 pixel graphical display with LED illumination Outputs Two frequency/pulse outputs optically isolated from DC Two alarm relays One 4/20 ma output with HART Inputs Two 4/20 ma and one 100 ohm RTD input for density, pressure and temperature input (option). Three 4/20 ma inputs for density, pressure and temperature input (option). Digital Interfaces HART over 4/20 ma output PanaLink over RS232/485/USB Modbus over RS232/485 (option)

Hazardous Area Certifications USA/Canada: Class 1, Div 1, groups B, C, & D Europe: ATEX II 2 G, Ex de IIC (Ex d IIC as option) IEC Ex: Ex de IIC (Ex d IIC as option) CE Compliance 2004/108/EC EMC Directive 2006/95/EC LVD Flow Computer Functionality Integrated flow computer with full P and T volume corrections according to API 11.1 Flow Ranges 0.5 m/s 10 m/s 0.5 m/s 10 m/s 0.5 m/s 10 m/s Nominal Diameter 1.69 ft/s 33 ft/s 1.69 ft/s 33 ft/s 1.69 ft/s 33 ft/s in mm (m 3 /h) (m 3 /h) (GPM) (GPM) (BBL/h) (BBL/h) 4 100 15 280 66 1230 94 1760 6 150 33 630 145 2770 207 3960 8 200 58 1130 255 4980 364 7120 10 250 91 1800 400 7900 573 11300 12 300 131 2500 580 11000 825 15700 14 350 179 3500 790 15400 1130 22000 16 400 233 4500 1030 19800 1470 28300 18 450 296 5700 1300 25100 1860 35900 20 500 365 7000 1600 30800 2300 44000 24 600 525 10000 2310 44000 3300 63000 Typical flow rates for 0.5 m (19.6 in) per second and 10 m (393 in) per second are listed above. The Sentinel LNG is a full bore meter and the flow range is a function of the pipe and not the meter itself.

Sentinel Electronics SEN898 Ordering Information SEN898 SEN 898 electronics for custody transfer measurement Feature 1: Power 1 100 to 240 VAC operating voltage 2 12 to 32 VDC operating voltage Feature 2: Inputs (not possible for LNG due to active temperature compensation) 1 One 100 ohm RTD input, Two 4-20mA inputs 2 Three 4-20mA inputs Feature 3: Communications 1 Modbus RTU over RS232/RS485 Feature 4: Flow Computer (not possible for LNG due to active temperature compensation) API LNG API correction of volume per API Chapter 11.1 (for LCT only, 3 inputs required) Active compensation for tube contraction (for LNG only, 3 inputs required) Feature 5: Explosion proof 1 USA/CAN explosion proof, Class 1, Div 1, groups B, C, D 2 European flameproof, II 2G Ex d IIC 3 European flameproof increased safety, II 2G Ex de IIC Feature 6: Electronics Mounting L Local Mounting, if ordering with SEN-LCT or SEN-LNG R Remote Mounting, if ordering with SEN-LCT or SEN-LNG S Stand Alone with Remote Mounting, cable length selectable (Max. 300 ft or 91 m) S Special SEN898

Sentinel LNG Liquid Custody Transfer Flowmeter SEN898 Sentinel Liquid Custody Transfer Flowmeter Feature 1: Diameter 4 4 flowspool with RF flanges acc to ASME B16.5 (See Flow Rates table for metric conversion) 6 6 flowspool with RF flanges acc to ASME B16.5 8 8 flowspool with RF flanges acc to ASME B16.5 10 10 flowspool with RF flanges acc to ASME B16.5 12 12 flowspool with RF flanges acc to ASME B16.5 14 14 flowspool with RF flanges acc to ASME B16.5 16 16 flowspool with RF flanges acc to ASME B16.5 18 18 flowspool with RF flanges acc to ASME B16.5 20 20 flowspool with RF flanges acc to ASME B16.5 24 24 flowspool with RF flanges acc to ASME B16.5 28 28 flowspool with RF flanges acc to ASME B16.47 30 30 flowspool with RF flanges acc to ASME B16.47 32 32 flowspool with RF flanges acc to ASME B16.47 36 36 flowspool with RF flanges acc to ASME B16.47 Feature 2: Pressure class 150 150 lbs pressure rating 300 300 lbs pressure rating Feature 3: Material 304 Stainless steel, A182 Grade 304/304L 316 Stainless steel, A182 Grade 316/316L Feature 4: Schedule 10S Schedule size 10S 40S Schedule size 40S STD Schedule size STD S Special Feature 5: Design Criteria A ASME B31.3 P ASME B31.3 with PED approval Feature 6: Electronics Mounting S Remote mounting, cable length selectable (max 300 ft or 91 m) Feature 7: Material certs 1 Material certs 2 Material certs with EN 10204 3.1 inspection certificate Feature 8: NACE Requirements 1 NACE MR0175 2 NACE MR0103 Feature 9: Special Requirements S Special SEN898 www.gesensinginspection.com 920-425E 2009 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.