Tribology In Orthopaedics. Dr. Anirudh Sharma M.S. Orthopaedics

Similar documents
Tribology Module4: Lubricants & Lubrication

Intergranular Corrosion (IGC)

Chapter 6 Wear. Abrasive Wear (plus Erosive Wear). Encountered in % of cases. Surface Fatigue Wear. Encountered in % of cases.

2.79J/3.96J/BE.441/HST522J MATERIALS: BONDING AND PROPERTIES. M. Spector, Ph.D.

Status of surface modification techniques for artificial hip implants

Short Aramid Fibre Reinforced Ultra-High Molecular Weight Polyethylene Composite. A new hip-prosthesis Hofsté, Joanna Maria

DuraCer. Ceramic Components. The Strong Choice In Ceramics

MECHANICAL AND PHYSICAL PROPRIETIES

Ceramics in Orthopaedic and Neurosurgery. B. Sonny Bal, MD MBA JD PhD University of Missouri-Columbia Amedica Corporation

Module-13. Corrosion and Degradation of materials

Introduction to Joining Processes

Joining of Dissimilar Automotive Materials

POLYETHYLENE [UHMW PE]

One Surgeon. One Patient. FLH /11

Journal of Biomechanical Science and Engineering

Prevention Strategies Design and Coatings

Tool wear Mechanism. 1.Abrasive wear. 1.Abrasive wear cont. 1/4/2013

Effect of Normal Load and Sliding Velocity on Friction Coefficient of Aluminum Sliding Against Different Pin Materials

Polymer Interface and Adhesion

Tribology of Journal Bearings Subjected to Boundary and Mixed Lubrication

Contact plating material options for electronic connectors A comparison of hard gold and hard gold flashed palladium-nickel (80/20)

The perfect equation for hips

SPECIFICATION FOR REINFORCED SOIL WALL

ISO 6281 INTERNATIONAL STANDARD. Plain bearings Testing under conditions of hydrodynamic and mixed lubrication in test rigs

Slidmekanismer og slidforebyggelse

TRIBOLOGY RELIABILITY

where n is known as strain hardening exponent.

ME 383S Bryant February 10, 2005

Overview of Coatings and Surface Treatments

APPLICATION OF CERAMICS TO HIGH PRESSURE FUEL SYSTEMS. Thomas M. Yonushonis Cummins, Inc.

Impact Fatigue Failure Investigation of HVOF Coatings

Tablet Coating Failure Using Micro Scratch Testing

Mechanics of surface damage: A new look at the old problem of wear

This is an author produced version of Incorporating corrosion measurement in hip wear simulators: An added complication or a necessity?.

Cutting Tool Materials and Cutting Fluids. Dr. Mohammad Abuhaiba

Advanced Surface Technology

Friction and wear of bearing material under water contaminated compressor oil

Molybdenum Disulfide - The Ideal Solid Lubricant and Anti-Galling Material. White Paper

Wear Mechanisms. 7.1 Introduction. Koji Kato. Koshi Adachi

A Molecular Dynamics Study of Polishing and Grinding. S.J. Eder, U. Cihak-Bayr, D. Bianchi, A. Vernes, G. Betz

GRINDING AND OTHER ABRASIVE PROCESSES

SCREW DESIGN BASICS The Processor Point Of View. Andrew W. Christie Optex Process Solutions, LLC

Experiences of PLD Technology for LIB Separators. PICODEON Oy. Neal White

Mechanism of Building-Up Deposited Layer during Electro-Spark Deposition

Module 3 Machinability. Version 2 ME IIT, Kharagpur

Self Healing Ceramic (Surfaces)

Magneto Rheological Fluid (MRF)

Chapter Outline: Failure

Evaluation of the Surface of Nitinol after MR Polishing Process

Laboratory Experiments in Corrosion Engineering II

SESSION ETD 422 FAILURE ANALYSIS STUDIES IN COLLABORATION WITH INDUSTRIES FOR STUDENT DESIGN PROJECTS

Effects of Fretting Corrosion on Au-Sn Plated Contacts in Electronic Cable Interconnect

Metal-on-Metal Articulation and Wear

COMMERCIALLY AVAILABLE ENHANCEMENT OF POLYMER PROPERTIES FOR TRIBOLOGICAL APPLICATIONS

LUBRICATION & MACHINING OF COMPACTED GRAPHITE IRON

THE USE OF SURFACE TEXTURING AND MICROSPHERES IN AQUEOUS BASED LUBRICATION

PRIREV. ZI Vagos, lote

Genesis of Friction between Macroscale contacts. Reference: Chapter 3 of the text books

INTRODUCTION. Think HSS

CORROSION PHENOMENA AN INTRODUCTION G P Rothwell

Falk WRAPflex Couplings Failure Analysis

Tutorial Corrosion II. Electrochemical characterization with EC-Lab techniques

Chapter 15 Extrusion and Drawing of Metals

Tribological Property of FG/UHMWPE Composites

Lubricating grease shear flow and boundary layers in a concentric. cylinder configuration

Tribology and Mechanics of Magnetic Storage Devices

Chapter 18: Powder Metallurgy

PPS Outshines Stainless Steel in Chemically-Hostile Valve Applications

Friction Coefficient Of Oil/Refrigerant Mixtures At A Pressure of 2.5 GPa

Frictional heating calculations for polymers

Defects and Diffusion

SKF composite plain bearings. Compact and maintenance-free

ME -215 ENGINEERING MATERIALS AND PROCESES

Dry Slide Wear Behavior of Graphite and SiC, TiO 2

7 Most Important Test Methods

MANUFACTURING PROCESSES. Tool Material & Cutting Fluid

Condensed Study Guide

Module 3 Selection of Manufacturing Processes. IIT Bombay

Extrusion. Key Issues to Address. Lecture 2. Process. Process Variants. Process Analysis. Problem Solving

EROSION, CAVITATION, AND FRETTING CORROSION JONATHAN FAN, JON MAZUR, NATHAN MELICHAREK, AND MIKE SCHMITTDIEL

ÓASM International DOI: /s /$19.00

Basic concepts for Localization of deformation. Stress vs. displacement/velocity boundary conditions - unstable/stable processes

Properties of the New Materials Used in Human Prosthetics and Orthotics

Polymer Composites Filled with RB Ceramics Particles as Low Friction and High Wear Resistant Filler

ALGRIP Slip-Resistant Metal Floor Plates Exceptionally durable slip-resistant flooring solutions for high traffic areas

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

Galvanic corrosion evaluation of 6061 aluminum coupled to CVD coated stainless steel Elizabeth Sikora and Barbara Shaw 6/9/2016

NANO SCRATCH TESTING OF THIN FILM ON GLASS SUBSTRATE

Corrosion Control and Cathodic Protection Data Sheet

Calcium Carbonate in Blown HDPE Film

AMILON Custom PTFE Products

Tribological behaviour of carbon filled hybrid UHMWPE composites in water

A New Structural Bonding Process for Ferromagnetic Sheet Stacking used in Electric Motors (Rotors, Stators )

Price and Availability

related to the welding of aluminium are due to its high thermal conductivity, high

Laser assisted Cold Spray

Strength Characterization of Ceramic Femoral Heads of Total Hip Arthroplasties using a

Solutions. for Severe Corrosion

Transcription:

Tribology In Orthopaedics Dr. Anirudh Sharma M.S. Orthopaedics

History David Tabor (23 October 1913-26 November 2005) A British Physicist Coined the term Tribology First recipient of the Tribology Gold Medal

Introduction Science of interacting surfaces in relative motion Tribos (Greek) meaning rubbing Encompasses Friction, Lubrication, Wear

Friction Resistance to sliding motion between two bodies in contact Friction Force (F) Applied Load (W) F = μw (μ is the coefficient of friction) F is independent of the apparent contact area

Contact Area True contact area is between asperities (1% of the apparent contact area) Asperities deformation load / surface hardness Bonds form at contact points and must be broken to initiate movement Thus μs (static coefficient) > μd (dynamic coefficient)

Lubrication Synovial fluid: produced by Type B fibroblast-like cells (Type A cells help phagocytosis) clear viscous liquid made up of proteinase, collagenase, hyaluronic acid, lubricin and prostaglandins

Synovial fluid (cont.): is a dialysate of blood plasma without clotting factors or erythrocytes Exhibits non-newtonian flow properties Pseudoplasticity = fall in viscosity as shear rate increases Thixotropy = time-dependent decrease in viscosity under constant shearing

Synovial fluid (cont.): Functions Lubrication Cartilage nutrition

Sommerfeld Number (S) S viscosity velocity / stress Lambda value λ = fluid thickness / surface roughness Critical lambda value for reduced friction is 3

Rougher surface with higher asperities requires a thicker fluid film Artificial joints have a lambda value of < 3 Metal-on-metal and ceramic-on-ceramic approach this value As lambda value exceeds 3 the friction starts to increase again

Types of Lubrication 1. Boundary 2. Fluid film 2.1 Hydrodynamic 2.2 Elastohydrodynamic

Boundary Lubrication Contact-bearing surfaces separated only by lubricant of molecular thickness Occurs when fluid film has been depleted Involves single monolayer of lubricant adsorption on each surface Glycoprotein lubricin, found in synovial fluid, is the adsorbed molecule Friction is independent of the sommerfeld number

Fluid film Lubrication Separation of surfaces by a fluid film minimum thickness exceeds the surface roughness of the bearing surface prevents asperity contact

Hydrodynamic Non parallel rigid bearing surfaces Separated by a fluid film slide tangentially Converging wedge fluid forms Viscosity within this wedge produces a lifting pressure No contact between surfaces and hence no wear May occur during the swing phase of gait

This model assumes that: Surfaces are rigid and non-porous The lubricant velocity is constant (newtonian) The relative sliding speed is high Loads are light

Elastohydrodynamic Lubrication Occurs in non rigid bearing surfaces Macroscopic deformation serves to trap pressurized fluid This increase surface area which decreases the shear rate This increases the viscosity of synovial fluid

Microelastohydrodynamic Lubrication Assumes asperities of articular cartilage are deformed under high loads This smoothens out the bearing surface Which creates a film thickness of 0.5 1 μm, sufficient for fluid film lubrication

Squeeze film Occurs when there is no relative sliding motion Pressure builds up as viscous fluid offers resistance to being squeezed Lubricant layer becomes thinner and the joint surfaces come into contact This mechanism is capable of carrying high loads for short lengths of time

Boosted Lubrication Under squeeze film conditions Water and synovial fluid are pressurized into cartilage Leaving behind a concentrated pool of hyaluronic acid protein This lubricates the surfaces

Weeping Lubrication Articular cartilage is fluid filled, porous and permeable It is capable of exuding and imbibing lubrication fluid Cartilage generates tears of lubricant fluid by compression of the bearing surface The process is thought to contribute to nutrition of the chondrocytes

Wettability Relative affinity of lubricant for another material Measured by the angle of contact

Hydrostatic An unnatural system Fluid is pumped in and pressure is maintained to reduce surface contact

Lubrication Mechanisms - Synovial Joints No one knows exactly when each type of lubrication comes into play Intact synovial joints have a very low coefficient of friction (~0.02) Articular cartilage surface is not flat and has numerous asperities Kind of lubrication occurring at one time in a synovial joint varies according to the loading conditions

Wear Progressive loss of material from the surface due to relative motion Generates further third body wear particles Softest material is worn first

Wear Mechanisms Wear is either chemical (usually corrosive) or mechanical Types of mechanical wear include: Adhesive Abrasive Fatigue

Adhesive Wear Occurs when junction is formed between two opposing surfaces Junction is held by inter-molecular bonds This force is responsible for friction This junction is responsible for spot welding / transfer Steady low wear rate

Abrasive wear (ploughing) Occurs when softer material comes into contact with significantly harder material Microscopic counterface aspirates on the harder surface cut and plough through the softer material This produces grooves and detaches material to form wear debris This is the main mechanism in metal / polymer prostheses

Abrasive wear (cont.): Third body abrasive wear occurs when extraneous material enters the interfacial region Trapped wear debris produces a very high local stress This quickly leads to localized fatigue failure and a rapid, varying wear rate. Thought to be responsible in part for backside wear at rigid metal / polymer couplings and other modular interfaces

Fatigue Wear Caused by accumulation of microscopic damage within the bearing material Depends on the frequency and magnitude of the applied loads and on the intrinsic properties of the bulk material Also dependent on contact stress

Fatigue wear (cont.): Decreased by: Conformity of surfaces Thicker bearing surface Increased by: Higher stiffness of material Misaligned or unbalanced implants

Fatigue wear (cont.): In TKA the joint is less conforming and the polyethylene more highly stressed Delamination: repeated loading causes subsurface fatigue failure

Corrosive wear Mechanical wear may remove the passivation layer This allows chemical corrosion to occur

Fretting wear Localized wear from relative motion Over a very small range Can produce a large amount of debris

Wear sources in Joint Arthroplasty Primary articulation surface Secondary articulation surface backside of modular poly insert with metal screw fretting with the metal shell of acetabular liners Cement / prosthesis micromotion Cement / bone or prosthesis / bone micromotion Third body wear

Linear wear Loss of height of the bearing surface Expressed in mm / year

Volumetric wear Total volume of material that has been worn away Expressed in mm3 / year

Wear rate Debris volume; highest in the first year wearing in Steady state then achieved (debris volume related to load and sliding distance) Accelerated wear occurs at the end of a prosthesis life Knee Joint, rectilinear sliding generates alignment of the linear polymeric molecules, reduces wear Cross-links increase the strength but also increase the brittleness of the polymer

Head size Larger the femoral head the greater the sliding distance and volumetric wear Volume of wear debris = πpr2 (P is penetration and r is radius of femoral head) Smaller head size decreases the sliding distance and reduces volumetric wear Smaller the femoral head the greater the penetration

Laws of wear The volume of material (V) removed by wear increases with load (L) and sliding distance (X) but decreases as the hardness of the softer material (H) increases: V LX / H V = klx k = a wear factor for a given combination of materials

Factors that determine wear Patient factors Weight (applied load) Age and activity level (rate of applied rate load)

Factors that determine wear (cont.): Implant factors Coefficient of friction (lubrication) Roughness (surface finish) Toughness (abrasive wear) Hardness (scratch resistance, adhesive wear) Surface damage Presence of third bodies (abrasive wear)

Wear in prosthetic hips There is a combination of wear and creep Creep usually dominates the initial penetration rate Majority of the linear penetration after the first year is due to wear Direction of creep is superomedial Direction of wear is superolateral

Wear in prosthetic hips: Cup penetration can be measured in the following ways: By comparison between initial and follow-up radiographs, corrected for magnification Shadowgraph technique Computer software scan imaging

Biological effects of wear particles Large (micron sized) particles have localized effects at the bone / implant / cement interfaces Small (nanometre sized) particles are thought to have the potential for systemic effects

Local Particles 0.1 10 μm diameter Phagocytosed by macrophages Stimulate the release of soluble pro-inflammatory mediators (tumour necrosis factor (TNF), interleukin (IL)-1, IL-6, PGE2, matrix metaloproteinases) Mediators released stimulate bone resorption by osteoclasts and impair the function of osteoblasts

Local (cont.): Major factors that affect extent of osteolysis are: Volume of wear debris >150 mm3 per annum is thought to be the critical level Total number of wear particles Morphology of particles Size of particles Immune response to the particles

Systemic Metal ion release is increased five-fold by metal-on-metal bearing surfaces Metal ions are not phagocytosed Controversy surrounds the long-term effects Immune sensitization and neoplastic transformation are concerns Pseudotumours and metal hypersensitivity leads to early hip revision

Corrosion Corrosion is reaction of a metal with its environment resulting in continuous degradation to oxides, hydroxides or other compounds Passivation Oxide layer forms on the alloy surface Strongly adherent Acts as a barrier to prevent corrosion Can be jeopardized by mechanical wear

Types of corrosion Uniform attack Galvanic Crevice Pitting Fretting (combination of wear and crevice corrosion) Intergranular Inclusion corrosion Leaching corrosion Stress corrosion

Uniform attack Most common type of corrosion Occurs with all metals in electrolyte solution Uniformly affects the entire surface of the implant

Galvanic Two dissimilar metals are electrically coupled together An anode and cathode form in essence a small battery develops as ions are exchanged

Crevice Occurs in a crevice or crack Characterized by oxygen depletion Tip of the crack cannot passivate due to lack of oxygen Accelerated by high concentrations of H+ and Cl

Pitting Similar to crevice Corrosive attacks are more isolated and insidious A localized form of corrosion in which small pits or holes form Dissolution occurs within the pit

Fretting corrosion Synergistic combination of wear and crevice corrosion Relative micro movement forms where the passive layer is removed Can cause permanent damage to the oxide layer, Particles of metal and oxide can be released from fretting

Intergranular Metals have a granular structure Intergranular corrosion occurs at grain boundaries due to impurities

Inclusion corrosion Occurs due to impurities left on the surface of materials e.g. metal fragments from a screwdriver Similar to galvanic

Leaching corrosion Similar to intergranular corrosion Results from electrochemical differences within the grains themselves

Stress corrosion (fatigue) Metals repeatedly deformed and stressed In a corrosive environment Show accelerated corrosion and fatigue damage

Ideal implant Biocompatibility: inert, non-immunogenic, nontoxic, non-carcinogenic Strength: sufficient tensile, compressive and torsional strength, stiffness and fatigue resistance Workability: easy to manufacture and implant Inexpensive No effect on radiological imaging Corrosion free

Thank You Source: Postgraduate Orthopaedics, Paul A. Banaszkiewicz, FRCS Queen Elizabeth Hospital and North East Surgery Centre, Gateshead, UK