GE Enduris* 3500 High Solids Silicone Roof Coating

Similar documents
GE SCM3500 High Solids Silicone Roof Coating

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

ROOF SUBSTRATE PREP MANUAL

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

TOPCOAT System Specifications Corrugated Transite Panels

TOPCOAT Restoration Specifications Structural Concrete

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

GEOGARD LO Base Coat / GEOGARD Finish Coat

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION

Application Specification:

Chemical Name: Manufacturer: Container size: Location: Disposal:

To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins.

System Specifications

Acry-Tek 4200 / SPF Recoat System

RTV615. Technical Data Sheet

RTV133. Technical Data Sheet

ITEM 458 WATERPROOFING FOR STRUCTURES

RTV31, RTV60 and RTV88 silicone rubber compounds differ primarily in viscosity in the uncured state.

RTV31, RTV60 and RTV88 silicone rubber compounds differ primarily in viscosity in the uncured state.

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

RTV160. Electronic Grade Silicone Flowable Adhesive Sealant

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Pacific Polymers Elasto-Deck BT Guide Specification

SECTION ALPHAGUARD RESTORATION 20 YEAR WARRANTY SYSTEM. f. Conditions and Division 01 Specification Sections, apply to this Section.

SilGrip* PSA595 Pressure Sensitive Adhesive

SilGrip* PSA518 Pressure Sensitive Adhesive

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

Rust-Oleum Industrial Brands Specification

Section COATING RESTORATION

RTV106. One-Component Acetoxy High Temperature Adhesive Sealant

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

MasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: METACRYLICS

MAKE ROOFS LAST LONGER

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

RTV630B. Technical Data Sheet

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

2016 Capital Improvement Project REHABILITATION OF METAL ROOFING SECTION REHABILITATION OF METAL ROOFING PART 1 - GENERAL

SECTION ARCHITECTURAL SPECIFICATIONS FOR INDOOR WOOD ATHLETIC FLOORING

Firestone Polyiso Boards

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

RTV615. RTV615 High Strength Transparent Silicone Rubber Compound

SECTION RESILIENT SHEET FLOORING

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet

Henry #1 CHOICE OF PROFESSIONALS

PRODUCT DATA SHEET SARNACOL 2121

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

RTV627 silicone rubber compound is dark gray in color and has an easily pourable viscosity of about 1300 cps.

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

PEDA-GARD ALIPHATIC. Pedestrian Traffic Coatings. System Summary

AVM System 500. Aussie Membrane 500

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

TEKTON Flashings and TEKTON Construction Tape

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

SECTION Pedestrian Traffic Coatings{PRIVATE } 1.1 SUMMARY (Specification writer shall add, delete or amend, as deemed necessary)

SECTION METAL ROOF PANELS

SECTION MANUFACTURED ROOF EXPANSION JOINTS

LAKEWOOD HIGH SCHOOL RECOAT/REROOF PROJECT 100% OWNER REVIEW

Silopren* LSR Technical Data Sheet. Silopren LSR 2750

Liquid applied polyurea hybrid membrane

Section Fluid Applied Waterproofing

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

PRODUCT GUIDE SPECIFICATION

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane

RTV 11. RTV 11, Silicone Rubber Compound

Florock Seamless Flooring Systems

KOSTER AMERICAN CORPORATION

GenFlex EZ TPO Peel & Stick SA (HW) APPLICATION GUIDE

Instruction Guide APPLICATION OF CIM TO CONCRETE

SCOPE OF WORK PROJECT IDENTIFICATION

SECTION GUTTERS AND DOWNSPOUTS

REV:6-30/09/30. Liquid Rubber Timber Specification

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

SECTION EPOXY FLOORING SYSTEMS

TOPCOAT Product Catalog

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

RTV627 Flame Retardant Silicone Rubber Compound

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

Guide Specification SDP 200

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: BASF CORPORATION

Engine Bay Floors Floor Resurfacing 4000

ROOF BALLAST MATERIALS ARCHITECTURAL CONCRETE PAVING SLABS SRS LEVELING BLOCK SYSTEM INSTALLATION PART GENERAL 1.

SECTION A. American Society for Testing and Materials (ASTM):

***********************************************************************************

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

PRODUCT SPECIFICATIONS

SECTION CONCRETE AND MASONRY COATINGS

SL150 Guide Specification

Transcription:

GE Enduris* 3500 High Solids INSTALLATION GUIDE SPECIFICATION FOR RESTORATION OF EXISTING SINGLE-PLY ROOFS (20 YEAR WARRANTY) PART 1 GENERAL 1.01 SUMMARY A. GE Enduris* 3500 silicone roof coating, manufactured by Momentive Performance Materials, Inc. (MPM), is a high solids, solvent-free, alkoxy-based silicone roof coating, which moisture cures to a durable, breathable, waterproof barrier that is highly resistant to degradation from UV and natural weathering. Enduris 3500 silicone roof coating may be used to topcoat existing singleply membranes, including TPO, PVC, EPDM and CSPE (Hypalon ), for restoration and longevity. B. Scope: Installation of Enduris 3500 silicone roof coating, labor and accessory materials. C. Exclusions: This guide specification does not include: repair or replacement of roof accessory items such as vents, expansion joints, drains, penetrations and mechanical equipment; evaluation and correction of roof load capacity or wind uplift resistance. 1.02 SUBMITTALS A. Product Data: Technical Data Sheets (TDSs) and Safety Data Sheets (SDSs) for all products used on project. B. Shop Drawings: Drawings indicating scope of work and roofing details. C. Sample Warranty (optional; see Section 1.06). 1.03 QUALITY ASSURANCE A. Manufacturer Qualifications: Enduris 3500 high solids, silicone roof coating supplied and manufactured by MPM are approved for and shall be used on this project. Upon request, MPM will provide certification that all MPM materials meet the physical properties required by the specification. B. Adhesion Test: Prior to estimating coating restoration project, conduct an adhesion test in accordance with MPM adhesion testing procedures to determine if a primer or other specific surface preparation is required. C. The silicone coating manufacturer shall have a minimum of 20 years experience in the manufacture of silicone roof coatings and be ISO 9001 certified. The coating shall have an Underwriters Laboratories (UL) Listing, Factory Mutual (FM) Class 1, 4470 Approval and a Miami-Dade NOA (Notice of Acceptance). GE is a registered trademark of General Electric Company and is used under license by Momentive Performance Materials Inc. *Enduris is a trademark of Momentive Performance Materials Inc. 1

Warranty Program for D. Contractor Qualifications: The contractor shall be approved by MPM and eligible to offer a GE Enduris Silicone Labor & Material Warranty. E. Deviations: Any deviation from this specification must be approved in writing by MPM. F. Field Quality Control: Upon completion of the roof coating project, an inspection by MPM s designated third-party inspection agency may be required. Consult with MPM for specific requirements. 1.04 DELIVERY, STORAGE AND PROTECTION OF MATERIALS A. Delivery: All products shall be delivered in the original, factorysealed drums, pails or other containers. All product containers shall be labeled with the manufacturer s name and address, product name and description, product date/expiration date and batch/lot number. B. Materials damaged during shipment, delivery or storage shall not be used on this project without approval of MPM. C. Handling and Storage: Store Enduris 3500 silicone roof coating containers at temperatures between 15 F and 109 F (-9 C to 43 C). Other materials shall be stored in accordance with the appropriate material s TDS. Keep all products out of direct sunlight and protected from extreme temperatures. D. SDSs and TDSs for all materials used on this project will be kept on site and reviewed by appropriate personnel before use. 1.05 GENERAL SITE CONDITIONS A. All mechanical units, skylights, vents and other protrusions, and other rooftop accessories should be in place prior to surface preparation and coating application. B. All mechanical units should be adjusted or shut down to prevent fumes and odors from entering the facility. C. Mask or otherwise protect all surfaces not to be prepared and/or coated to prevent overspray damage. Use wind screens as appropriate. D. Review existing and imminent weather conditions (including potential for extreme temperatures, relative humidity, frost, dew, and precipitation) to assure that coating and accessory material will have sufficient curing time. E. Temperature at the time of application of the Enduris 3500 silicone roof coating application should be above 0 F (-18 C) to allow coating to cure properly. Contact manufacturer if applying to substrates over 120 F (49 C). F. Apply Enduris 3500 silicone roof coatings only to clean, dry and secure surfaces. G. Protect Enduris 3500 silicone roof coating from foot traffic or other potential abuse during the curing process. The coating is considered cured when it is tack free and sufficiently durable to withstand roof traffic. *Enduris is a trademark of Momentive Performance Materials Inc. 2

Warranty Program for Enduris 3500 High Solids H. All work performed under this specification must be in accordance with all appropriate local, state and federal regulations. I. While cured Enduris 3500 silicone roof coating is unaffected by ponding water conditions, various professional roofing associations (including NRCA) consider ponding water undesirable and recommend that roofs be designed for positive drainage. Corrective action should be considered, prior to application of Enduris 3500 silicone roof coating, to correct existing ponding conditions and/or drainage deficiencies. 1.06 WARRANTY INFORMATION A. A manufacturer s limited labor & material warranty is available on eligible projects. Contact MPM Technical Support for details. B. Limited warranties are not available for continuous immersion service; cryogenic, freezer or cold storage facilities; or over existing wet roofing materials. Other limitations may apply. C. Inspections: Warranted projects are subject to: 1. Pre-job inspection and adhesion test. 2. Final quality control inspection. 3. Inspections may be performed by MPM or its designated third-party inspectors at MPM s discretion. D. Warranty submittals 1. MPM Warranty Pre-Approval Application 2. Adhesion test results PART 2 PRODUCTS 2.01 SILICONE COATING A. Enduris 3500 high solids, solvent-free, alkoxy-based, moisturecured, silicone roof coating supplied and manufactured by Momentive Performance Materials, Inc., Waterford, NY. B. Physical Properties shall be tested in accordance with ASTM D6694 as indicated in the table below. Property ASTM Value Tensile Strength D2370 200 psi min Elongation at Break (73 F) D2370 500% min Volume Solids D2697 90% min Weight Solids D1644 90% min *Enduris is a trademark of Momentive Performance Materials Inc. 3

2.02 EPDM WASH SOLUTION Warranty Program for A. GE Enduris EPDM WASH, Momentive Performance Materials, Waterford, NY. Refer to the Enduris EPDM WASH Technical Data Sheet for physical property information. 2.03 SEAM TREATMENT MATERIALS A. GE Enduris Seam Sealant, Momentive Performance Materials, Waterford, NY. Refer to the Enduris Seam Sealant Technical Data Sheet for physical property information. B. GE UltraSpan* UST / USM pre-cured silicone transition sheets and molded corners, Momentive Performance Materials, Waterford, NY. Refer to the UltraSpan Technical Data Sheet for physical property information. C. Reinforcement Fabric: GE RF100 series is a 100% polyester spunlaced textile reinforcing fabric that is available in 4, 6 or 12 widths. Refer to the RF100 Technical Data Sheet for physical property information. 2.04 ACCESSORY MATERIALS A. Traffic Mats: Yellow Spaghetti (manufactured by Western Plastics, Inc.) pressure bonded, non-woven pads (or in rolls) made of spaghetti like strands of flexible polyvinyl chloride, nominal thickness 5/16. B. Yellow Walkway Coating: GE SilShield* 2400 Protection Yellow Silicone Coating PART 3 EXECUTION 3.01 SINGLE-PLY SURFACE PREPARATION A. Adhesion Test: On a representative, prepared and dried surface in the field of the single-ply membrane, or any substrate to receive remedial coating, perform an adhesion test of the Enduris 3500 silicone roof coating in accordance with MPM adhesion testing procedures. Report results to MPM Technical Support. Results will determine what, if any, additional surface preparation will be required. B. Remove all loose dirt, gravel, ballast, dust and surface contaminants that would adversely affect the adhesion of the Enduris 3500 silicone roof coating restoration coating by power washing, vacuuming, power sweeper, air blowing and/or other suitable means. *Enduris and UltraSpan are trademarks of Momentive Performance Materials Inc. 4

C. Inspect drainage system to assure that drains are open and functional and meet building code requirements. Install additional drainage consistent with good roofing industry practice to eliminate potential for ponding water. Warranty Program for D. Thoroughly inspect and/or test the existing roof system for the presence of moisture within the roof assembly. Remove areas of wet substrate and replace with compatible materials. E. Thoroughly inspect the entire single-ply roof surface, details and accessories and correct defects such as cracks, seam splits, shrinkage, chalking, brittleness and alligatoring. 1. GE Enduris Seam Sealant shall be applied to all membrane cracks and seams. Application can be done by brush (50 wet mils) or trowel and may require 24 hours to cure prior to base and/or topcoat application. 2. Field seams at end laps are to be cleaned and re-sealed. The areas cleaned should extend 4 on each side of the seam. The seam is to be sealed with GE Enduris Seam Sealant. For all corners and transition areas (including areas prone to movement ) use GE RF100 4, 6, or 12 polyester fabric embedded in additional application of Enduris 3500 silicone roof coating. Avoid buckling or wrinkling of fabric in any area. 3. All field seams and flashings must be thoroughly checked for loose areas, fishmouths or poor adhesion and are to be cut out and removed. Any flashing or field membrane that has stress cracks is to cleaned and sealed with GE Enduris Seam Sealant or reinforced with a layer of Enduris 3500 silicone coating and RF100 Reinforcing Fabric before silicone top coating is applied. 4. GE UltraSpan transition membranes may be required on certain specific conditions. Consult with MPM Technical Support for recommendations. F. Inspect mechanically attached single-ply membranes and replace any fasteners which are loose or have backed out. Remove all loose fasteners and replace them with a larger diameter fastener to ensure there is a tight grip to the deck. If a tight grip is not achieved, remove the fastener and plate and relocate them at least 4 from the original location. Repair with compatible membrane. Primer application or other surface preparation may be required based on the results of MPM adhesion testing procedures. Consult with MPM Technical Support for materials and procedures. G. Required treatment of EPDM surfaces: Clean all EPDM surfaces with GE Enduris EPDM Wash. Apply at a minimum rate of 1.0 gallons/300-500 ft 2 using low-pressure spray, mop or roller; and allow to dwell on membrane for 15-120 minutes depending on ambient temperature and humidity. Rinse washed EPDM membrane thoroughly to remove residue. *Enduris and UltraSpan are trademarks of Momentive Performance Materials Inc. 5

Warranty Program for 3.02 COATING APPLICATION A. The Enduris 3500 silicone roof coating shall be applied uniformly in one or more coats at a theoretical application rate of 2.5 gallons/100 ft 2 to achieve a WFT (wet film thickness) of 40 mils and a minimum total DFT (dry film thickness) of 36 mils. NOTE: Theoretical coating application rate is based strictly on minimum WFT requirements and must be increased for site-specific conditions such as surface texture, overspray loss, container and other residues, application technique and environmental conditions. B. Required final DFT is 36 mils minimum on any given area of the roof surface. Apply additional coating as needed to meet this requirement. C. Additional coats: When additional applications of coating are needed, allow sufficient cure time between applications to provide a stable working surface. Subsequent coating should be applied in a spray, roller or brush pattern perpendicular to the previous application. D. Equipment: Enduris 3500 silicone roof coating may be applied by spray equipment, roller, brush or gauge rake. E. Cure: Enduris 3500 silicone roof coating cures by reacting with ambient moisture. Cure time will be reduced at elevated ambient humidity and temperatures. 3.03 FINISHED COATING CHARACTERISTICS A. The cured Enduris 3500 silicone roof coating should be monolithic and seamless, encapsulating the entire existing surface. The coating should be free of holidays, voids, pinholes and cracks. Apply additional coating as necessary to correct defects. B. Minimum cured coating thickness is 36 mils DFT. 3.04 SAFETY REQUIREMENTS A. Refer to appropriate SDSs (Safety Data Sheets) for additional safety information. B. Before starting to apply coating, primers or other materials, any potential sources of air entry into the building must be sealed off. 3.05 CLEANUP A. Keep all work areas clean, clear and free of debris at all times. B. Do not allow trash, waste or debris to accumulate on the roof. Remove these items from the roof on a daily basis. C. Collect and properly store all tools and unused materials at the end of each workday. *Enduris is a trademark of Momentive Performance Materials Inc. 6

D. Dispose of or recycle all trash and excess material in a manner conforming to current EPA regulations and local laws. Warranty Program for E. Properly clean the finished roof surface after completion and make sure the drains and gutters are not clogged. F. Clean and restore all damaged surfaces to their original condition. 3.06 QUALITY CONTROL A. Enduris 3500 silicone roof coating restoration projects are subject to pre- job progress and final inspections by MPM, its designated third-party inspectors, or others subject to warranty requirements and contract documents. DISCLAIMER: THE MATERIALS, PRODUCTS AND SERVICES OF MOMENTIVE PERFORMANCE MATERIALS INC. AND ITS SUBSIDIARIES AND AFFILIATES (COLLECTIVELY SUPPLIER ), ARE SOLD SUBJECT TO SUPPLIER S STANDARD CONDITIONS OF SALE, WHICH ARE INCLUDED IN THE APPLICABLE DISTRIBUTOR OR OTHER SALES AGREEMENT, PRINTED ON THE BACK OF ORDER ACKNOWLEDGMENTS AND INVOICES, AND AVAILABLE UPON REQUEST. ALTHOUGH ANY INFORMATION, RECOMMENDATIONS, OR ADVICE CONTAINED HEREIN IS GIVEN IN GOOD FAITH, SUPPLIER MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, (i) THAT THE RESULTS DESCRIBED HEREIN WILL BE OBTAINED UNDER END-USE CONDITIONS, OR (ii) AS TO THE EFFECTIVENESS OR SAFETY OF ANY DESIGN INCORPORATING ITS PRODUCTS, MATERIALS, SERVICES, RECOMMENDATIONS OR ADVICE. EXCEPT AS PROVIDED IN SUPPLIER S STANDARD CONDITIONS OF SALE, SUPPLIER AND ITS REPRESENTATIVES SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS RESULTING FROM ANY USE OF ITS MATERIALS, PRODUCTS OR SERVICES DESCRIBED HEREIN. Each user bears full responsibility for making its own determination as to the suitability of Supplier s materials, services, recommendations, or advice for its own particular use. Each user must identify and perform all tests and analyses necessary to assure that its finished parts incorporating Supplier s products, materials, or services will be safe and suitable for use under end-use conditions. Nothing in this or any other document, nor any oral recommendation or advice, shall be deemed to alter, vary, supersede, or waive any provision of Supplier s standard Conditions of Sale or this Disclaimer, unless any such modification is specifically agreed to in a writing signed by Supplier. No statement contained herein concerning a possible or suggested use of any material, product service or design is intended, or should be construed, to grant any license under any patent or other intellectual property right of Supplier covering such use or design, or as a recommendation for the use of such material, product, service or design in the infringement of any patent or other intellectual property right. is a trademark of General Electric Company and is used under license by Momentive Performance Materials Inc. *Enduris and UltraSpan are trademarks of Momentive Performance Materials Inc. Momentive and the Momentive logo are trademarks of Momentive Performance Materials Inc. Copyright 2016 Momentive Performance Materials Inc. All rights reserved. WNT3500SP20316 7