Semstone Construction Details

Similar documents
DETAILS GUIDE STRATASHIELD STANDARD FLOORING TABLE OF CONTENTS

Instruction Guide APPLICATION OF CIM TO CONCRETE

ITEM 458 WATERPROOFING FOR STRUCTURES

Atlas Chempruf TM. Coating and Lining Systems

Installation Instructions

Application Guide for. MasterSeal Traffic 1500MD

PPC Cement TUTORIAL. how to screed a floor

Florock Seamless Flooring Systems

FLUID APPLIED WATERPROOFING

LIQUID RUBBER INDUSTRIES ENGINEERING SPECIFICATIONS FOR ENGINEERS AND ARCHITECTS. Diagram 1: Standard Membrane Continuation 150 mm Overlap

1.3 Work shall include all reinforcement and accessories necessary to complete installation.

Vulkem EWS with PUMA Technology (Heavy Duty) APPLICATION INSTRUCTIONS

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

Blue Barrier Liquid Wrap 2300

PAYING ATTENTION TO DETAIL by Bob Cusumano

SECTION EPOXY FLOORING SYSTEMS

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

Resin Bound Installation Guide

SECTION SITE CONCRETE

SECTION 26 - COLD PLANE ASPHALT CONCRETE PAVEMENT TABLE OF CONTENTS

ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound

APPLICATION INSTRUCTIONS

Application Instructions for Keystone Kool Deck on Existing Concrete

Caparol System PRO Data sheet

SECTION RESILIENT SHEET FLOORING

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

SLAB ON GRADE Insul-Joint or Expansion Joint Material as Required by A/E Specifications AquaCheck Liquid Coating 400 (Waterproofing Membrane) with Aqu

***********************************************************************************

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

SECTION RESINOUS FLOORING or SECTION QUARTZ FLOORING

PLATON FOUNDATION WRAP

Application Guide for MasterSeal Roof 3000

A Design Review of Waterproofing Codes

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

BEP Blue Barrier Installation and Application Guide

WATERPROOFING CONSTRUCTION JOINTS

1. Rapid Set Cement. 2. Methods of preparation. 3. How to stage a job site. 4. Installation Mix, place, finish. 5. Coloring the TRU.

KIM Best Practices Guide for Shotcrete Nov 2013

TECHNICAL SPECIFICATIONS

Construction. Sikaflex 15 LM. Application Instructions. Sika Corporation

Sample Specification

FIVE STAR PRODUCTS, INC. (800)

SAMPLE SPECIFICATION

Maintenance & Rehabilitation. Treatments. Crack Sealing. Sealant Types. Asphalt Pavement Preservation: Identification of Alternative Treatments

AquaFlash System Installation Guide DS196

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

Waterproofing construction Joints

CAULKING INSTRUCTIONS GRABBERGARD EFC & IFC

SECTION EPOXY TERRAZZO

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

A. Testing Laboratory Services: Section B. Excavation, Site Fill and Rough Grading: Section Sub-Base Course Material (If requested).

Applications (As provided by Avanti International)

FEATURES. 150 F- Continuous NOT recommended for area with Thermal Shock. DUD IC K, INC Miller Parkway. Streetsboro, OH

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE

GENERAL SHALE NATURAL THIN ROCK VENEER Installation Guide. GeneralShale.com

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

Application Guidelines

AQUATITE. Also designed as: Crack/gap filler for masonry and unglazed ceramics Sealants against leaks Repairer for roof cracks and gutters

SECTION CERAMIC TILING

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

Engine Bay Floors Floor Resurfacing 4000

SYNTHETIC GRASS INDOOR SURFACE SPECIFICATIONS: K9GRASS LITE

PROTECTO-CRETE 900/900SF

STONHARDENGINEEREDSOLUTIONS

Installation Information 2016

TECHNICAL DATA SHEET

Make your floor a unique artwork!

1-part polyurethane pourable self levelling floor joint sealant

BioPrism Solid Surface

TECHNICAL DATA SHEET

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

TILING SPECIFICATIONS

BEP Blue Barrier Installation and Application Guide

CONCRETE REPAIR IN ACTION: USING THE MANUAL AS A GUIDE. Christen Longoria, P.E. San Antonio District Project Engineer

Editing notes to assist users are separated from specification text by rows of asterisks. Delete these notes prior to final printing.

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

Stanford University Facilities Design Guidelines SECTION SEAL COATS. C. Section : Traffic Striping and Pavement Markings

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

Gas Protection System Components

Broadcast Parking Garage System

A. Access doors and frames are part of an access door and frame allowance.

Lifting Gear Hire Corporation

METHOD STATEMENT 001 CONCRETE BALCONY WATERPROOFING FOR DIRECT FIXED TILES

Construction. 2-part epoxy impregnation resin. 1 Sikadur /6

Union County Vocational - Technical Schools Scotch Plains, New Jersey

AVM System 500. Aussie Membrane 500

CONCRETE POLISHING SPECIFICATION NEW OR EXISTING CONCRETE

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

GEOGARD LO Base Coat / GEOGARD Finish Coat

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. RobinsonBrick.com

Foirgniochta. Marking Scheme Leaving Certificate Examination, Ordinary Level. Construction Studies

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

CSI SECTION MAINTENANCE OF CONCRETE Repair & Resurfacing with Rapid Hardening, High Strength, Low-Shrink, Non-Metallic Cementitious Materials

SECTION CEMENT BOARD SUPPORTED ADHERED MASONRY VENEER. 2. Installation materials including adhesives, mortars, and pointing mortars.

WATERPROOFING CONCRETE TIE HOLES USING XYPEX

TOPCOAT Restoration Specifications Structural Concrete

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Transcription:

Semstone Construction Details

SP01-94 Treatment for Expansion Joints, Control Joints, and Structural Cracks, Vertical and Horizontal, for Non-Vehicular Traffic 1. Maintain joint/crack through coating. Structural cracks can be maintained through the coating by taping over the crack before application of coating, then removing the tape before the coating sets. 2. Prepare bonding surfaces in accordance with instructions recommended in SEMSTONE Flexible Coating product data sheet and application guidelines. 3. Place 2 wide duct tape (bond-breaker) over joint/crack. 4. Apply SEMSTONE Primer to area inside boundary tape. Allow to dry tack free. 5. Apply a 50 mil base coat of SEMSTONE Flexible Coating. 6. Embed a layer of SEMSTONE Flexible Coating with engineering fabric into the base coat. Width of fabric and overall system depends on job specifications. 7. Apply a 10 mil topcoat of SEMSTONE Flexible Coating to ensure saturation of fabric. 8. Optional: For a non-skid surface, broadcast angular grit onto the SEMSTONE Flexible Coating topcoat while wet. SP01-94

Treatment for Horizontal to Vertical Transition SP02-94 1. Prepare bonding surfaces in accordance with instructions found in recommended SEMSTONE Flexible Coating product data sheet and application guidelines. 2. Install 2 wide duct tape (bond-breaker), centered on the joint. 3. Mix and apply recommended SEMSTONE Primer to an area 4 wide centered on the joint. Allow to dry tack free. 4. Apply a 50 mil base coat of SEMSTONE Flexible Coating to the prepared and primed surface. 5. Embed a 4 wide layer of SEMSTONE Flexible Coating with engineering fabric into the base coat. 6. Apply a 10 mil topcoat of SEMSTONE Flexible Coating to ensure saturation of fabric. SP02-94

Treatment for Expansion Joints, Control Joints, and Structural Cracks in Traffic Areas SP03-94 Preparation: Expansion and Control Joints Starting 1 back from the center of the joint, saw-cut a straight line 1/4-1/2 deep parallel with joint. Make this saw-cut on both sides of the joint. Using a chipping gun, chip a taper starting at the saw cut going toward the joint. Remove any existing joint material to finish flush with the bottom of the taper. Remove all dust and debris. Preparation: Structural Cracks Using a pneumatic crack chasing tool or chipping gun with a bushing tool attached, follow the crack making a 2 wide x 1/2 deep channel centered on the crack. Remove all dust and debris. Installation: 1. Prepare bonding surface in accordance with instructions found in product data sheet and application guidelines. 2. Install specified SEMSTONE coating to the floor surface and extend coating into the taper to joint/crack. Allow to cure to tack free. 3. Prepare surface of coating inside tapered area. Follow instruction for intercoat surface preparation in the technical bulletin and application guidelines for the coating system specified. 4. Apply recommended SEMSTONE Primer to prepared area. Allow to dry tack free. 5. Fill tapered recess with SEMSTONE Flexible Coating. Embed a 2 wide strip of SEMSTONE Flexible Coating with engineering fabric into the surface of the wet SEMSTONE Flexible Coating. Saturate the fabric with additional SEMSTONE Flexible Coating. The finished surface of the SEMSTONE Flexible Coating and fabric should be slightly below the adjacent floor surface. SP03-94

SP04-94 Loop Treatment for Expansion Joints, Control Joints, and Structural Cracks Intended for Immersion Service 1. Prepare bonding surfaces in accordance with instructions found in SEMSTONE Flexible Coating product data sheet and application guidelines. 2. Mix SEMSTONE Flexible Coating into a putty using Part C. 3. Apply SEMSTONE Flexible Coating putty in a 2-3 wide strip centered over the joint. The SEMSTONE Flexible Coating strip should be approximately 1/2 high in the center and have tapered edges. Allow to cure until firm. 4. Cover SEMSTONE Flexible Coating with duct tape. 5. Follow instructions for intercoat surface preparation found in the SEMSTONE Flexible Coating product data sheet. Install SEMSTONE reinforced coating system as specified. SP04-94

Treatment for Equipment Footings SP05-94 1. Prepare bonding surfaces in accordance with instructions found in SEMSTONE Flexible Coating product data sheet and application guidelines. 2. Apply recommended SEMSTONE Primer to the prepared surfaces. Allow to dry tack free. 3. Mix and apply SEMSTONE Flexible Coating with Part C by brush at a minimum thickness of 30 mils. SP05-94

Seal for Tank Bottom and Foundation Treatment SP06-94 1. Prepare bonding surfaces in accordance with instructions found in SEMSTONE Flexible Coating product data sheet and application guidelines. 2. Install 2 wide plastic bond-breaker tape centered at tank baseplate/concrete interface. 3. Apply recommended SEMSTONE Primer. Allow to dry tack free. 4. Apply a 50 mil base coat of SEMSTONE Flexible Coating with Part C to prepared and primed surface. 5. Embed a layer of SEMSTONE Flexible Coating with engineering fabric into base coat. 6. Apply a 10 mil top coat of SEMSTONE Flexible Coating to ensure saturation of fabric. SP06-94

Seal for Pipe Penetrations SP07-94 1. Abrasive blast or sand bonding surfaces around pipe 2 on wall and 2 on pipe. 2. Apply recommended SEMSTONE Primer to prepared surface. Allow to dry tack free. 3. Mix SEMSTONE Flexible Coating with Part C and 20/40 mesh aggregate. Apply material at a 2 radius around pipes. SP07-94

Treatment for Sumps and Trenches SP08-94 1. Prepare bonding surfaces in accordance with instructions found in SEMSTONE Flexible Coating product data sheet and application guideline. 2. Mix and apply recommended SEMSTONE Primer as required by product selection. Allow to dry tack free. 3. Install 1 radius of putty to inside corners. 4. Apply a 64 mil base coat of aggregate filled SEMSTONE coating to trench/sump floor and walls. Immediately embed a layer of Scrim Cloth into the base coat. Use rollers to embed the Scrim Cloth, and flat trowels to smooth the aggregate filled coating over the Scrim Cloth. 5. Apply a 64 mil top coat of SEMSTONE aggregate filled coating by trowel. Remove trowel marks and close surface using a stiff bristled brush dipped in appropriate SEMSTONE smoothing liquid. SP08-94

Treatment for Floor Drains and Grating Ledge Mid-Floor Termination Point SP09-94 1. Starting 4 back from termination point, chip a tapered keyway toward the termination point. The keyway depth should be four times the floor coating thickness at the termination point. 2. Prepare bonding surfaces in accordance with instructions found in product data sheet and application guidelines. 3. Apply recommended SEMSTONE Primer to the prepared area. Allow to dry tack free. 4. Blend SEMSTONE coating with 20/40 mesh aggregate and grout in keyway at the time the floor coating is installed. SP09-94

Joint Pouring Treatment SP10-94 Preparation: Round off sharp edge of joint using a grinder. 1. Prepare bonding surfaces in accordance with instructions found in the specified Carboline joint filler material product data sheet and application guidelines. 2. Insert a closed cell polyethylene backer rod into the joint. The size of the backer rod should be 1.25-to-1.5 times the width of the joint. The backer rod should be placed at a consistent depth of 1/2 the width of the joint. 3. Apply specified Carboline primer to area inside boundary tape. Allow to dry tack free. 4. Pour specified Carboline joint filler material into joint. The finished surface of the joint filler material should be even with the adjacent floor surface. Consult Carboline for selection of joint filler material for chemical environment and exposure. SP10-94

Treatment for Structural Crack Repair SP11-94 IMPORTANT: Refer to Carboline s product data sheets, application guidelines and Material Safety Data Sheets for specific information about surface preparation, mixing, application and material safety for individual Carboline Preparation of Cracks: Using a crack chasing tool or chipping gun, follow the crack making a 1/2 wide x 1/2 deep V centered on the crack. Remove all dust and debris. Installation: 1. Prepare bonding surface in accordance with instructions found in product data sheets and application guidelines. 2. Install specified Carboline coating to the floor surface and extend coating into the taper to joint/crack. Allow to cure to tack free. 3. Prepare surface of coating inside tapered area. Follow instruction for intercoat surface preparation in the product data sheet and application guidelines for the coating system specified. 4. Fill tapered recess with specified Carboline joint filler material. The finished surface of the joint filler material should be even with the adjacent floor surface. Consult Carboline for selection of floor coating and joint filler material for chemical environment and exposure. SP11-94