TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

Similar documents
Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

OPTIMASS 7400 Technical Datasheet

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Flow Measurement SITRANS F M

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

VERIS Accelabar. Superior Flow Measurement Accuracy

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Pressure transducers DMU 02 Vario (flush)

Weighing Electronics. SIWAREX - PLC-based weighing modules SIWAREX FTC. Overview

FedEx Express Rates Effective January 1, 2018

Red Eye Multiphase Water-Cut Meter

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1

Gilflo flowmeters. for steam, liquids and gases

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

FedEx Express Rates. Effective January 6, 2014

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Target Inline Flowmeter

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

Products Solutions Services. Vortex. Prowirl

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Digital E3 Modulevel Liquid Level Displacer Transmitter

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

Magnetic float switch For vertical installation Model FLS for nuclear power plants

SITRANS T measuring instruments for temperature

Sum Oil, Gas, Coal, & Cement A B C D E F G H I J K L M N O P Q R S T

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Liquid level switch BW 17

Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E

Flow Meter Hire QUICK REFERENCE GUIDE

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

DIVA flowmeter. for saturated steam flow measurement

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

Swirl flowmeter FS4000 Compact, reliable and robust

MAGFLO. Flow metering based on electromagnetic technology. For value-adding performance you can count on. FLOW DIVISION Simply Better

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

Sensor unit MC2 for toxic gases and oxygen with analog output

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

Compact flue gas analyser: testo 300 M-I

DML-Series. Pelton wheel flow meter

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

Rosemount 405 Compact Orifice Primary Element

robust reliable fatigue-proof STRAIN MEASUREMENT for Wind Turbines

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Welding Force Calibration Transmitter

TSI Model 3063 Thermal Mass Flowmeter

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Thermocouple for Flue Gas Temperature Measurements,

Flow Rate Transmitters/ Flow Switches

Omnigrad T TST310. Technical Information. RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring

Supplemental Instruction Manual

Electromagnetic flowmeter ProcessMaster FEP300/500 The first choice for the process industry

Over pressure Switching pressure difference (typical) Lower range Upper range

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

PETREX -CNT. Pipe systems for petrol stations Technical details

FLUXUS F/G601 and F/G608

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Vortex EX DELTA lowmeter Technical Specifications

SECTION 2: PROBES. Page 2-1

Using the PPM2 Portable Trace Moisture Transmitter

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:

LBHF LBHS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K. Ex d IIC U DIP A21

General Specification

For Safe and Delicious Water

Analytical Instruments

Tuffy T3 Liquid Level Controls with Electric Switches

SST-50 LEDs. SST-50 Binning and Labeling. Introduction: Table of Contents

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Tools for Pipe Welding

High temperature pressure sensor

Model B. Thermostatic Control Valves. Typical applications

GAS 3050P NDIR FLUE GAS

Technical Information Orbisint CPS11D and CPS11

Fine particle measuring system

Weighing Terminals. IND560x Terminal Comply Weigh Connect Control. Uncompromising Weighing Performance for Hazardous Areas

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

Expert SUBMERSIBLE LEVEL TRANSMITTERS BROCHURE EN 2.75 EXPERT BROCHURE 1401

Multiphase Flow Measurement. Multiphase Flow Meter Wet Gas Meter Multiphase Wet Gas Flow Meter Well Testing Service

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

Transcription:

TRICOR Series Coriolis Mass Flow Meters Technical Datasheet

TRICOR - Coriolis Mass Flow Meters Description The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors in a variety of processes, performing multiple measurements simultaneously with customizable process parameters and multiple communication languages. The TRICOR production team mechanically balances every meter, assuring the dual tubes are dynamically aligned and in perfect balance before flow begins. The unique design and cutting edge manufacturing procedures ensure a meter with the highest resistance to external influences. Features All-in-one instrument: direct measurement of mass flow, density and temperature, calculated measurement of volumetric flow No moving parts: low maintenance, no need for recalibration Easy to install: no straight run of pipe required and multiple mounting options available Mechanically balanced tubes and superior mechanical design for best-in-class density measurement Exceptional mechanical design resists external interference API gravity reading in software Exceptional ease of use and fast setup time: we will pre-program your process parameters Frequency output up to 10,000 Hz resolution Superior meter calibration: DAkkS-Accreditation as per DIN EN ISO/IEC 1705:005 Easily accessible, integrated meter diagnostics to verify meter health & performance Hazardous area certifications: ATEX, IECEx, ccsaus, EAC (TR-CU) Customized process connections available Principle of operation Coriolis Mass Flow Meters () operate with two tubes with coils that cause them to oscillate at their resonance frequency. Should a measurement flow enter the measuring tube, Coriolis forces are the result. Coriolis forces appear in oscillating systems when a mass moves towards or away from a rotational axis. These forces act on the inlet and outlet side in the opposite direction and minimally deform the measuring tubes. The deflection of the measurement tubes is captured by sensors on the inflow and outflow side. These two sensors measure a phase shift that is proportional to the mass flow. The resonance frequency of the tubes varies depending on the density of the medium to be measured. This effect is used to measure the density of the medium. Since the elastic properties of the flow tubes depend on the temperature, a temperature measurement is carried out for compensation. The primary characteristics such as mass flow rate, density and temperature are measured with a single flow meter. The volume flow can be determined based on the mass flow rate and density. Additional Options Net Oil software High pressure designs available up to 345 bar/5000 PSI Special calibrations for an oil viscosity up to 100 mm /s Integrated pressure compensation Customizable installation length Extended warranty

Coriolis Mass Flow Meters - TRICOR Product Overview Compact version Exd housing: Wall mounted (remote version) Version with TCE 6000 (including options) Housing: Panel mounted (remote version) 3

TRICOR - Coriolis Mass Flow Meters Transducer - Technical Data for Liquids 035 0650 1550 Max. Flow Rate (kg/h) 35 650 1550 3100 5500 7900 8000 65000 30000 Max. Flow Rate (lb/min) 1 4 57 114 0 90 109 388 8450 3100 5500 Basic Accuracy (% o.r.) ±0.1 Zero Stability (% f.s.) ±0.01 Repeatability (% o.r.) ±0.05 7900 08K 065K 30K Density Measuring Range 0-500 kg/m³,.5 g/cm 3 (higher ranges on request) Density Accuracy ±1.0 kg/m 3, ±0.001 g/cm 3 (special calibration on request) Density Repeatability ±0.5 kg/m 3, ±0.0005 g/cm 3 Temperature Accuracy Temperature Repeatability ±1 C ±0.5 % of reading (±1.8 F ±0.5 % of reading) ±0. C (±0.36 F) Process and Ambient Process Connections Max. Pressure Standard (Option) Pressure Drop at Max. Flow female thread 1/ adaptors for flanges, dairy and tri-clamp 00 bar/900 PSI (345 bar/5000 PSI) flanges EN109, ANSI B16.5, DIN51, threaded tri-clamp 100 b ar/1450 PSI for detail information please contact us -40 C... +100 C (-40 F... +1 F) (standard) Process Temperature (non Ex) -40 C... +150 C (-40 F... +30 F) (optional) -60 C... +00 C (-76 F... +39 F) (optional) meter mount -40 C... +70 C (-40 F... +158 F) (T4) n/a Process Temperature (Ex) remote version -40 C... +70 C (-40 F... +158 F) (T4) -40 C... +135 C (-40 F... +75 F) (T3) -60 C... +00 C (-76 F... +39 F) (T) Ambient Temperature -40 C... +70 C (-40 F... +158 F) Storage Temperature -40 C... +100 C (-40 F... +1 F) Electr. Connections Remote screw type terminals Electr. Connections Meter Mount none (internally connected to the electronics) Ingress Protection IP65 (IP66/IP67 on request) General Tube Arrangement serial serial Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 8 mm 43 mm Tube Material 1.4404/AISI 316L Housing Material Dimensions 1.4404/AISI 316L see drawings 1.4301/AISI 304 optional: 1.4404/AISI 316L Calibration for Liquids and Gases: The TRICOR flowmeters are always factory calibrated with water. Calibration Conditions: Water : 0 C... 5 C (68 F... 77 F), ambient temperature : 0 C... 5 C (68 F... 77 F) All specifications are based on above mentioned calibration reference conditions, a flow calibration protocol is attached to each instrument. Stated accuracy combines the effects of repeatability, linearity and hysteresis. Typical flow dynamics based on max. flow rate is 100:1. 1.4404/ AISI 316L 4

Coriolis Mass Flow Meters - TRICOR Accuracy for Liquids Flow Rate of full Scale Accuracy Zero Point Basic Accuracy * 100 ± Basic Accuracy < Zero Point Basic Accuracy * 100 ± Zero Point Measured Value * 100 Example for a 035: 35 kg/h * ZeroPoint (0.01 %) = 0.035 kg/h 1 lb/min * 0.01 % = 0.001 lb/min 35 kg/h * Basic Accuracy (0.1 %) = 0.35 kg/h 1 lb/min * 0.1 % = 0.01 lb/min Result: (0.035 / 0.35) * 100 = 10 % (3.5 kg/h) (0.001 / 0.01) * 100 = 10 % (1. lb/min) All flow rates 10 % or 3.5 kg/h (1. lb/min): Measured error = Basic Accuracy All flow rates < 10 % or 3.5 kg/h (1. lb/min): Measured error = (Zero Point / Measured Value) * 100 5

TRICOR - Coriolis Mass Flow Meters Transducer - Technical Data for Gases 035 0650 1550 Nom. Flow Rate (kg/h) 1) 3) 78 177 333 740 910 1430 5100 15650 48900 Nom. Flow Rate (lb/min) 1) 3) 3 7 1 7 34 53 188 575 1797 Nom. Flow Rate (Nm 3 /h) 1) ) 109 47 464 1031 168 1993 7109 1813 68157 Nom. Flow Rate (SCFM) 1) ) 64 146 73 607 747 1173 4184 1838 40115 3100 5500 Basic Accuracy (% o.r.) ±0.5 Zero Stability in kg/h (lb/min) 0.035 (0.001) 0.065 (0.004) 0.155 (0.0057) 0.31 (0.0114) 0.55 (0.00) Repeatability (% o.r.) ±0.5 7900 0.79 (0.09) 08K.8 (0.103) 065K 6.5 (0.39) 30K 3 (0.845) Density Measuring Range see comment 3) Density Accuracy ±.0 kg/m 3, ±0.00 g/cm 3 (special calibration on request) Density Repeatability ±1 kg/m 3, ±0.001 g/cm 3 Temperature Accuracy Temperature Repeatability ±1 C ±0.5 % of reading (±1.8 F ±0.5 % of reading) ±0. C (±0.36 F) Process and Ambient Process Connections Max. Pressure Standard (Option) Pressure Drop at Max. Flow female thread 1/ adaptors for flanges, dairy and tri-clamp 00 bar/900 PSI (345 bar/5000 PSI) flanges EN109, ANSI B16.5, DIN51, threaded tri-clamp 100 b ar/1450 PSI for detail information please contact us -40 C... +100 C (-40 F... +1 F) (standard) Process Temperature (non Ex) -40 C... +150 C (-40 F... +30 F) (optional) -60 C... +00 C (-76 F... +39 F) (optional) meter mount -40 C... +70 C (-40 F... +158 F) (T4) n/a Process Temperature (Ex) remote version -40 C... +70 C (-40 F... +158 F) (T4) -40 C... +135 C (-40 F... +75 F) (T3) -60 C... +00 C (-76 F... +39 F) (T) Ambient Temperature -40 C... +70 C (-40 F... +158 F) Storage Temperature -40 C... +100 C (-40 F... +1 F) Electr. Connections Remote screw type terminals Electr. Connections Meter Mount none (internally connected to the electronics) Ingress Protection IP65 (IP66/IP67 on request) General Tube Arrangement serial serial Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 8 mm 43 mm Tube Material 1.4404/AISI 316L Housing Material 1.4404/AISI 316L 1.4301/AISI 304 optional: 1.4404/AISI 316L 1.4404/ AISI 316L Dimensions see drawings Max. allowed flow velocity (Ma 0.5) For gas applications, flow rate and pressure drop for individual sensor sizes are dependent on operating temperature, pressure and fluid composition. Therefore, when selecting a sensor for any particular gas application, please use the the TSP (TRICOR Sizing Program) or contact us. 1) Nominal flow rates that produce approximately 3 bar (43 psi) pressure drop for natural gas at 50 bar (75 psi) operational pressure. ) Normal reference conditions (Nm 3 /h) are 1.013 bar und 0 C. Standard (SCFM) reference conditions are 14.7 psi und 60 F. 3) Flow rate and density range depend on the gas density and the pressure range. 6

Coriolis Mass Flow Meters - TRICOR Accuracy for Gases Flow Rate of full Scale Accuracy Zero Point Basic Accuracy * 100 ± Basic Accuracy < Zero Point Basic Accuracy * 100 ± Zero Point Measured Value * 100 Analogous to calculation for liquids. Only the basic accuracy value (% o. r.) is deviant from the calculation for liquids. Example for a 035: 35 kg/h * ZeroPoint (0.01 %)= 0.035 kg/h 1 lb/min * 0.01 % = 0.001 lb/min 35 kg/h * Basic Accuracy (0.5 %) = 1.635 kg/h 1 lb/min * 0.5 % = 0.06 lb/min Result: (0.035 / 1.635) * 100 = % (6.5 kg/h) (0.001 / 0.06) * 100 = % (0.4 lb/min) All flow rates % or 6.5 kg/h (0.4 lb/min): Measured error = Basic Accuracy All flow rates < % or 6.5 kg/h (0.4 lb/min): Measured error = (Zero Point / Measured Value) * 100 Ex Certifications ATEX (Ex) ATEX (Exn) IECEx (Ex) ccsaus (Ex1) 4) ATEX + IECEx + ccsaus Zone 4) 5) triple approval (Ex3) EAC (TR-CU) Zone 1: Group IIC or IIB, T...T4 Zone : II 3G Ex na IIC T...T4 Gc Zone 1: Group IIC or IIB, T...T4 Class 1, Division 1: Group A, B, C, D or C, D, T T4 1: Group IIC or IIB, T...T4 and Class 1, Division 1: Group A, B, C, D or C, D, T T4 Group IIC or IIB, T T4 4) For ccsaus and triple Ex-approval the Ex-approvals for remote electronics in 1.4404/316L is pending. 5) Only with remote electronics 7

TRICOR - Coriolis Mass Flow Meters TCE 8000/8100 Transmitter - Technical Data General Display Supply Voltage Programming Interface graphic, 13 x 3 dot 4 V DC, ±0 % or 90 64 V (version dependent) via front keyboard or Windows-based TRICOR configurator program (MODBUS) RS485 (MODBUS-RTU), Option HART, other options on request EMC according to EN 61000-6-4 and 61000-6- Power Consumption ExD Housing: Wall-mounted Dimensions Electrical Connections Cable Glands max. 6 W see drawing cage clamp terminals for 7-13 mm cables Housing Material aluminium diecast (option: 1.4404/AISI 316L) Protection Class Weight Temperature Housing: Panel-mounted (only TCE 8000) Dimensions Electrical Connections Housing Material Protection Class Weight Temperature Analog Output Current Outputs (x) Resolution Linearity Temperature Drift Load Output Value Pulse Output Frequency Range Output Signal Status In- and Output Status Output Control Input Analog Input (option) Input Type Resolution Linearity Temperature Drift Supply Voltage IP65 (IP66/IP67 on request) with Aluminium diecast housing: 3.8 kg/8.3 lb with 3 m cable with 1.4404/AISI 316L housing: 6.15 kg/13.56 lb ambient: -40 C... +70 C (-40 F... +158 F) storage and transport: -40 C... +80 C (-40 F... +176 F) see drawing cage clamp terminals Noryl front: IP50, rear: IP30 0.4 kg/0.88 lb ambient: 0 C... +60 C (3 F... + F) storage and transport: -0 C... +70 C (-4 F... +158 F) 4... 0 ma passive, two-wire, isolated 14 bit ±0.05 % of full scale 0.05 % per 10 K < 60 Ω (at 4 V supply) programmable: flow, total, density, temperature 0.5-10000 Hz active push pull output for flow rate push pull programmable (in TOTAL mode: 0.5-100 Hz; in FREQUENCY mode: 0.5-10000 Hz) programmable 4-0 ma active for two-wire passive pressure sensor 1 bit ±0.05 % of full scale 0.05 % per 10 K > 0 V (at 0 ma sensor current) 8

Coriolis Mass Flow Meters - TRICOR TCE 6000 Transmitter - Technical Data General Supply Voltage 4 V DC, ±0 % Programming via interface Interface RS485, USB (option) EMC according to EN 61000-6-4 and EN 61000-6- Power Consumption max. 4 W Connections connectors M1 Housing Material aluminium diecast Temperature ambient: -40 C... +70 C (-40 F... +158 F) storage: -40 C... +80 C (-40 F... +176 F) Protection Class IP65 Analog Output Current Output 4... 0 ma active Resolution 14 bit Linearity ±0.05 % Temperature Drift 0.05 % per 10 K Load < 800 Ω Output Value programmable: flow, total, density, temperature Pulse Output Frequency Range Output Signal Status In- and Output Status Output Control Input for ESTA (OPTV output) 0.5-1000 Hz active push pull output for flow rate, optional: insulated optical frequency output push pull programmable (option) (in TOTAL mode: 0.5-100 Hz; in FREQUENCY mode: 0.5-10000 Hz) programmable (standard: 1 input/option: inputs), optional: insulated optical control input Note: For parameterization of the flow meter, the interface may be used. Prerequisite: Parameter setting is not allowed during active ESTA operation. TRD 8001 Remote Display - Technical Data Display Supply Voltage Programming Interface to TCE graphic, 13 x 3 dot via interface via front keyboard RS485 EMC according to EN 61000-6-4 and 61000-6- Dimensions 90 x 10 x 50 mm (h x w x d) Connections Housing Material Protection Class Weight Temperature Wall Mount connectors M1, B coded ABS- FR (plastic, flame retardant) IP64 0.4 kg/0.88 lb operation: 0 C... +60 C (3 F... + F) storage and transport: -0 C... +80 C (-4 F... +176 F) hidden screws 9

TRICOR - Coriolis Mass Flow Meters 035 to 0650 035 0650 Sensor Type A D E G 6) H L 7) Y 8.43 in (14 mm) 8.43 in (14 mm) M6 10 M6 10 0.59 in (15 mm) 0.59 in (15 mm) G ½ G ½ 7.17 in (18 mm) 7.17 in (18 mm) 4.33 in ( mm) 4.33 in ( mm) 8.50 in (16 mm) 8.50 in (16 mm) 1550 to 3100 1550 3100 Sensor Type A D E G 6) H L 7) Y 13.78 in (350 mm) 13.78 in (350 mm) M6 10 M6 10 0.71 in (18 mm) 0.71 in (18 mm) G ½ G ½ 11.0 in (80 mm) 11.0 in (80 mm) 5.51 in ( mm) 5.51 in ( mm) 15.1 in (384 mm) 15.1 in (384 mm) 6) other connections on request 7) further lengths on request 10

Coriolis Mass Flow Meters - TRICOR 5500 to 065K 5500, 7900 08K 065K Sensor Type B C H L 6) I.D. Connection 7).40 in (61 mm) 3.15 in (80 mm) 5.94 in (151 mm) 8.03 in (04 mm) 9.96 in (53 mm) 15.4 in (387 mm) 10.4 in (60 mm) 1.40 in (315 mm) 18.90 in (480 mm) 18.11 in ( mm) 4.61 in ( mm) 3.68 in ( mm) Ø 0.51 in (Ø 13 mm) Ø 0.91 in (Ø 3 mm) Ø 1.57 in (Ø 40 mm) on request on request on request 30K 11

TRICOR - Coriolis Mass Flow Meters Meter-Mount Electronics TCE 8000/8100 Wall-Mount Electronics TCE 8000/8100 1

Coriolis Mass Flow Meters - TRICOR Standard Connection Head (A) High Temperature Connection Head (H) 13

TRICOR - Coriolis Mass Flow Meters Panel-Mounted Housing Meter-Mount Electronics TCE 6000 (F) Remote Display TRD 8001 14

Coriolis Mass Flow Meters - TRICOR Ordering Information Meter (Series TRICOR) XXXX - X X - X X X X - X X X X - Ex - X X Process connections 8) see page 17 ff XX Mechanical options Medium Temperature range -40 C +100 C (-40 F +1 F) S -40 C +150 C (-40 F +30 F) Ex max : 135 C (75 F) H -40 C +70 C (-40 F +158 F) Ex, compact E -60 C...+00 C (-76 F...+39 F) T Pressure range With rupture disc max. 5 BAR (7.5 PSI) G Mechanical Design Standard S Face to face length Standard (other length on request) S Electronics options Electronics type Junction box Alu (only for replacements) A Z Z S Junction box 1.4404/316L H Z Z S Meter mount electronics TCE 8000 (NPT) 9) C Meter mount electronics TCE 8000 (M0 x 1.5) 9) K Meter mount electronics TCE 8100 (NPT) 9) M Meter mount electronics TCE 8100 (M0 x 1.5) 9) O Meter mount electronics TCE 6000 10) F Interface 11) RS485 (Modbus RTU) S RS485 (Modbus RTU) and HART A RS485 (Modbus RTU) + FF (not with Ex) B FF (Foundation Fieldbus ) D RS485 (Modbus RTU) + USB (only TCE 6000) F Not used Z Supply voltage 4 V DC D 90 64 V AC M Not used Z Options Pressure compensation, 4 0 ma input A 8 pin I/O connector (TCE 6000 only) B Optical I/O (TCE 6000 only) C No option S EX-protection ATEX + IECEx Zone1: Group IIC or IIB, T T4 ATEX Zone : II 3G Ex na IIC, T T4 Gc ccsaus: Class 1, Division 1: Group A, B, C, D or C, D, T T4 ATEX+IECEx: Zone 1: Group IIC or IIB, T T4 and ccsaus: Class 1, Division 1: Group A, B, C, D or C, D, T T4 1) EAC (TR-CU): Group IIC or IIB, T T4 ExR Special Options NOC (Net Oil Computer) 01 8) For connections not indicated with installation length, please contact manufacturer 9) For compact version with Ex-protection temperature class T4 only 10) Ex-protection only available in the option Exn 11) Other interfaces on request 1) Only with remote electronics Ex Exn Ex1 Ex3 15

TRICOR - Coriolis Mass Flow Meters Ordering Information TCE Transmitter (Series 8XXX) TCE 8 X X X - X - X X X X - X X - XX 035 to 7900 (Alu) 8 0 0 1 08K to 065K (Alu) 8 0 1 1 30K (Alu) 8 0 1 035 to 7900 (1.4404/316L) 8 1 0 1 08K to 065K (1.4404/316L) 8 1 1 1 30K (1.4404/316L) 8 1 1 Housing Wall mount (NPT) Wall mount (M0 x 1.5) Panel mount 13) Panel mount, wide for "Ex", "associated equipment" 13) Options Interface 14) RS485 (MODBUS RTU) RS485 (MODBUS RTU) + HART Supply Voltage 4 V DC + 90 64 V AC (only housing S+L) B 4 V DC D 90 64 V AC (only housing W, I) M Electronic Options Standard Pressure compensation, 4 0 ma input Cable length 3 Meters/ 10 ft., Standard (high temperature) S (H) 6 Meters/ 0 ft., (high temperature) B (I) 10 Meters/ 33 ft., (high temperature) C (J) 15 Meters/ 49 ft., (high temperature) D(O) 0 Meters/ 65 ft., (high temperature) E (P) D-SUB Connector, (housing L+S) seperate cable required EX-Protection ATEX + IECEx Zone1: Group IIC, T T4 ATEX Zone : II3G Ex na IIC, T T4 Gc ccsaus: Class 1, Division 1: Group A, B, C, D or C, D, T T4 ATEX+IECEx, Zone 1: Group IIC or IIB, T T4 and ccsaus: Class 1, Div. 1: Group A, B, C, D or C, D, T T4 EAC (TR-CU): Group IIC or IIB, T T4 Special Options NOC (Net Oil Computer) 01 13) Only for TCE 80XX 14) Other interfaces on request W I S L S A S A N Ex Exn Ex1 Ex3 ExR 16

Coriolis Mass Flow Meters - TRICOR Slip on, process connection dim. + facing acc. ANSI B16.5 Installation length in mm (inch) Process connection 15) Code ½ ANSI flange class 150 AA ½ ANSI flange class 300 AB ½ ANSI flange class 600 AC ½ ANSI flange class 900 AD ½ ANSI flange class 1500 BV ½ ANSI flange class 500 BE 035 0650 1550 3100 5500 7900 08K 065K 30K ¾ ANSI flange class 150 BA ¾ ANSI flange class 300 BB ¾ ANSI flange class 600 BC ¾ ANSI flange class 900 BD ¾ ANSI flange class 1500 AI 1 ANSI flange class 150 AE 1 ANSI flange class 300 AF 1 ANSI flange class 600 AG 1 ANSI flange class 900 AH 1 ANSI flange class 1500 AQ 1 ANSI flange class 500 BN 1½ ANSI flange class 150 AJ 1½ ANSI flange class 300 AK 1½ ANSI flange class 600 AL 1½ ANSI flange class 900 AM 1½ ANSI flange class 1500 BI 15) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 17

TRICOR - Coriolis Mass Flow Meters Slip on, process connection dim. + facing acc. ANSI B16.5 Installation length in mm (inch) Process connection 15) Code ANSI flange class 150 AN ANSI flange class 300 AO ANSI flange class 600 AP ANSI flange class 900 AR ANSI flange class 1500 BU 035 0650 1550 3100 5500 7900 08K 065K 30K ½ ANSI flange class 150 BT ½ ANSI flange class 300 BY ½ ANSI flange class 600 BQ ½ ANSI flange class 900 BW 3 ANSI flange class 150 AS 3 ANSI flange class 300 AT 3 ANSI flange class 600 AU 3 ANSI flange class 900 AV 4 ANSI flange class 150 AW 4 ANSI flange class 300 AX 4 ANSI flange class 600 AY 4 ANSI flange class 900 AZ 5 ANSI flange class 150 BF 5 ANSI flange class 300 BG 5 ANSI flange class 600 BH 5 ANSI flange class 900 BJ 6 ANSI flange class 150 BM 6 ANSI flange class 600 BX 15) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 18

Coriolis Mass Flow Meters - TRICOR Slip on, process connection dim. + facing acc. EN 109-1 Form B Installation length in mm (inch) Process connection 15) DN 10, EN flange PN 16 DN 10, EN flange PN 40 DN 10, EN flange PN 63 DN 10, EN flange PN 100 DN 10, EN flange PN 160 DN 10, EN flange PN 50 DN 10, EN flange PN 400 Code DY DS DZ EA EB EC ED 035 0650 1550 3100 5500 7900 08K 065K 30K DN 15, EN flange PN 16 DN 15, EN flange PN 40 DN 15, EN flange PN 63 DN 15, EN flange PN 100 DN 15, EN flange PN 160 DN 15, EN flange PN 50 DN 15, EN flange PN 400 EE DA EF DB EG EH EI DN 0, EN flange PN 40 DT DN 5, EN flange PN 16 DN 5, EN flange PN 40 DN 5, EN flange PN 63 DN 5, EN flange PN 100 DN 5, EN flange PN 160 DN 5, EN flange PN 160 Mat.:. DN 5, EN flange PN 50 DN 5, EN flange PN 400 EZ DC EJ DD DW DW DP DV 15) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 19

TRICOR - Coriolis Mass Flow Meters Slip on, process connection dim. + facing acc. EN 109-1 Form B Installation length in mm (inch) Process connection 15) DN 3, EN flange PN 40 Code DR 035 0650 1550 3100 5500 7900 08K 065K 30K DN 40, EN flange PN 16 DN 40, EN flange PN 40 DN 40, EN flange PN 63 DN 40, EN flange PN 100 DN 40, EN flange PN 160 DN 40, EN flange PN 50 DN 40, EN flange PN 400 DU DE EK DF EL EM EN DN 50, EN flange PN 16 DN 50, EN flange PN 40 DN 50, EN flange PN 63 DN 50, EN flange PN 100 EO DG EP DH DN 65, EN flange PN 16 DN 65, EN flange PN 40 DN 65, EN flange PN 63 DN 65, EN flange PN 100 EQ DQ ER ES DN 80, EN flange PN 16 DN 80, EN flange PN 40 DN 80, EN flange PN 63 DN 80, EN flange PN 100 ET DJ EU DK 15) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 0

Coriolis Mass Flow Meters - TRICOR Slip on, process connection dim. + facing acc. EN 109-1 Form B Installation length in mm (inch) Process connection 15) DN 100, EN flange PN 16 DN 100, EN flange PN 40 DN 100, EN flange PN 63 DN 100, EN flange PN 100 Code EV DL EW DM 035 0650 1550 3100 5500 7900 08K 065K 30K DN15, EN flange PN 16 DN15, EN flange PN 40 DN15, EN flange PN 63 DN15, EN flange PN 100 EX DN EY DO DN150, EN flange PN 16 DN150, EN flange PN 40 DI DX EN flange weld neck Installation length in mm (inch) Process connection 15) DN 3, PN40 DIN 635 1.4404/316L Type C Face DN 3, PN64 DIN 636 1.4404/316L Type E Face DN 3, PN100 DIN 637 1.4404/316L Type E Face Code VO VP VQ 035 0650 1550 3100 5500 7900 08K 065K 30K Triclamp Installation length in mm (inch) Process connection 15) Code ½ Triclamp TA 035 0 (8.66) 0650 0 (8.66) 1550 50 (9.84) 3100 50 (9.84) 5500 7900 08K 065K 30K DN 5 Triclamp PN 16 DIN 3676 TL 10 (8.7) 10 (8.7) 40 (9.45) 40 (9.45) 15) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 1

TRICOR - Coriolis Mass Flow Meters Female thread Installation length in mm (inch) Process connection 15) Code ¼ NPT female thread FJ ¾ NPT female thread FL ½ NPT female thread FK NPT female thread FQ 035 0650 1550 3100 5500 7900 08K 065K 880 (34.65) 30K ¼ G, female thread FB ⅜ G, female thread FR ¾ G, female thread FC ½ G, female thread FA 15) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer.

Coriolis Mass Flow Meters - TRICOR Connection Cable for TCE 8000-S or TCE 8000-L to TCC X X - X X Lenght 3 Meter (Standard) ( 10 ft.) 0 3 6 Meter ( 0 ft.) 0 6 10 Meter ( 33 ft.) 1 0 15 Meter ( 49 ft.) 1 5 0 Meter ( 66 ft.) 0 Additional Accessories Model Code /GSD DAkkS-Calibration (ILAC) according to DIN EN ISO/IEC 1705:005 3.KAL-0100 CON.USB.RS: USB interface cable to RS 485 1.8 m (TRICOR configurator) 00490 IPS 9-14: IP65 Protection for TCE-80**-L 171 IPS 9-9: IP65 Protection for TCE-80**-S 1711 HSA 96: adapter TCE-80**-S and TCE-80**-L for rail mounting 17594 TRD 8001: remote display for TCE 6000 184 TRD-TCE-6-: Connection cable TRD-TCE 6000, m 1701 TRD-TCE-6-5: Connection cable TRD-TCE 6000, 5 m 17011 KAB-USB-TCE: USB Cable, USB to mini USB M1, m, for TCE 6000 17174 KAB-RS485-TCE: RS485 to USB connector cable 1.8 m for TCE 6000; FSDS;FFDB, FSDC 19563 Inspection certificate 3.1 according to DIN 50 049 / EN 1004 3.WKZ-0100 Oxygen cleaning 1969 TAG Plate (1.4404/316L) 19705 Pneumatic Power Gen. for TCE 6000 Version FSDC; 7.5W, 4 VDC, Plug M8, 3 pin,.5 m cable 0657 LW-LA-10 for FOP50/60 10m (5.5mm) fiber optic cable for TCE 6000 Version FSDC LW-LA-10 OPTV-0/X0 light pulse receiver and converter, DIN - rail for TCE 6000 Version FSDC OPTV-0/X0 3