WELCOME TO Webinar on Pumps & Circulators

Similar documents
Energy Effiency of Circulators

COMMISSION REGULATION (EC)

Presented at the EUROPUMP roundtable Brussels, October 6, 2011 by Prof. Dr. Bernd Stoffel

NCE Energy saving circulating pumps

EXTENDED PRODUCT APPROACH FOR PUMPS. Draft version

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

IE3? Premium Efficiency

50 Hz. TLCN, TLCHN Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS

In-line Twin Pump. Type Series Booklet. Omega DSL

Preparatory study for Steam Boilers Ecodesign

Pump ED 101. Pump Selection for VFD Operation Part 3 Q / H Pump Down vs Level Control. Introduction. Pump Down vs Level Control

IE3? Premium Efficiency

GRUNDFOS INDUSTRIAL SOLUTIONS. Stainless steel STAINLESS STEEL PUMPS. Upgrade your industrial applications

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

Series description Wilo-Drain STS 40

b) General instructions and documents to be submitted by an interested company:

PVXM API 610 / ISO (OH3)

The right partner for your project: Heating, ventilation and air-conditioning

MINOR. Electrical submersible drainage pump. Tel Fax Hz. No: PD603-EN. Revision

Flygt 3057, 50Hz. Technical Specification

HI Technical Affairs Update June 27, 2014 Mick Cropper VP Technical Affairs

Close Coupled Sump Pumps Type ETLB

NM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor

MEN Series. Single-Stage, End Suction Water Pumps. Experience In Motion MEN MENBLOC ME

Product Range Non-Metallic Pumps

Accelerated Capital Allowances Eligibility Criteria. Category: Process and Heating, Ventilation and Air conditioning (HVAC) Control Systems

N-pump, Standard Motor

Geothermal Tunnel Linings. Principles of Geothermal Tunnel Linings

Performance Efficiency Standard for Evaporative Cooling Equipment

Xylem VSD Payback Tool

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

NATIONAL CODES ON PUMPSETS. By D K Das Bureau of Indian Standards, New Delhi

Flygt 3057, 50Hz. Technical Specification

Pumps n Valves n Service. The right partner for your project. Heating, ventilation and air-conditioning

Doc. CEN/TC 228 N541 CEN/TC 228

Your system rendered fully transparent with SES System Efficiency Service

Flygt 3171, 50Hz. Technical Specification

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Experience In Motion. SIHI ISOchem Chemical Process Pumps with Magnetic Drive

Micro Hydro Turbine Test Facility at the NERDC

Model EVMS Vertical Multistage Pumps for the Global Market

Experience In Motion. SIHI Side Channel Pumps High Head at Low Flow

TOTEM. Cogeneration (CHP) Range. TECHNICAL SUBMITTAL TR r2. Highest total efficiency with modulating output and lowest NO X emissions available

European Technical ETA-04/0023 Assessment of 17 October 2017 General Part

FINAL DRAFT 21 DECEMBER 2015 FREQUENTLY ASKED QUESTIONS. COMMISSION REGULATION (EU) No 1253/2014. of 7 July 2014

Basic Principles for the Design of Centrifugal Pump Installations

Pump Division. Terra-Titan. TKL Vertical Cantilever Shaft Sump Pump. Bulletin PS-10-7 (E)

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

Cutting-Edge Pumping Solutions for the Concentrated Solar Power Generation

Autogas Series. Regenerative Turbine Coro-Flo Pumps. For LPG High Differential Pressure Applications

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

ISO 642 INTERNATIONAL STANDARD. Steel Hardenability test by end quenching (Jominy test) Acier Essai de trempabilité par trempe en bout (essai Jominy)

TKL Titan Slurry. Heavy-Duty, Dual Case Lined Pump. Bulletin PS-10-8c (E)

Energy labelling and ecodesign requirements for heat pumps

Operation of pumps in a district heating system supplying a distant major industrial user

Experience In Motion MPT. Self-Priming, Solids-Handling Pump

Experience In Motion. TKL Primo-Titan Self-Priming, Solids-Handling Pump

FREQUENTLY ASKED QUESTIONS DURING ELECTRO-MEDICAL DEVICE MARKET ACCESS

GOULDS PUMPS. Commercial Water. e-sv General Market Specifications. Applications. Specifications

Eco-Flow - C VARIABLE FREQUENCY DRIVE PRODUCT BROCHURE. for Commercial Swimming Pools & Water Feature Pumps. H flow 2. Pool & Spa Products Division

EuP and WEEE Directives

The complete, efficient, solar water pumping solution Delivering you more water!

ecocirc PREMIUM Series ErP 2009/125/EC 50/60 Hz motralec WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS Cod.

Doc. CEN/TC 228 N544 CEN/TC 228

THE SWEDISH ENVIRONMENTAL MANAGEMENT COUNCIL GPP CRITERIA FOR MEDICAL EQUIPMENT MALMÖ 19 SEPTEMBER 2012 EVA DALENSTAM,

Hydraulics Laboratory Experiment Report

COMMISSION STAFF WORKING DOCUMENT. Impact Assessment. Accompanying the document. Commission Regulations

Accelerated Capital Allowances Eligibility Criteria

VOGEL - Submersible Pumps in Stainless Steel Design TVS

ISO INTERNATIONAL STANDARD. Hydraulic fluid power On-line automatic particle-counting systems for liquids Methods of calibration and validation

ABSTRACT. The Guidelines Section C is related to the classification and grading approach of NSQ100 (Chapters & 4.1.3).

12 Temperature measurement SCT analogue

European Energy Efficiency Policies. Paolo Bertoldi European Commission DG JRC

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

6. Tool box. Theory. Heating. Life Cycle Cost. Speed Control FLOW THINKING. Basic pump theory Mixing loops. Basic theory. Calculation Example

ALTERNATOR. LSA 36 - single-phase to 11.5 kva

ISO INTERNATIONAL STANDARD

LAB TQ - MARCOGAZ Workshop. mchps Importance of experimental evaluation and intercomparison tests. Brussels May 3 rd 2012

Pump selection: a real example

Session VI Innovative Gas Appliances & Domestic Systems

Flow Rate Transmitters/ Flow Switches

Technical Toolbox for Technical Measures for use in SPINconstellations. - Belgium

Pump Vibration. Related Considerations and How Much is Too Much? MWEA Collection Systems Seminar. Steve Fehniger, P.E.

The e-gs 4" Range. Lenntech. Tel Fax

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users

EMAS KEY BENEFITS FOR ORGANISATIONS AND AUTHORITIES

EXPERIMENTAL COMPARISON OF THE PERFORMANCE OF TWO RΕVERSE OSMOSIS DESALINATION UNITS EQUIPPED WITH ENERGY RECOVERY DEVICES

(Text with EEA relevance)

Horizontal and Vertical End Suction Pumps

Mobile Nitrogen Vaporizer Skid

UFL Micro Biogas CHPs

Introduction. Ultra Reliable

FLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.

6. PUMPS AND PUMPING SYSTEM

Calibration/Validation Guidance For Miller Welding Equipment

Notification of the indicative national energy efficiency target 2020 for Belgium

FLOWSERVE CORPORATION Guardian Pumps. Centrifugal ANSI Pumps Product Training Program

Wemhoner Short Cycle Melamine Press

Ensuring product reliability in the wind power industry Vestas Technology R&D, 6. October Reliability

Transcription:

WELCOME TO Webinar on Pumps & Circulators Ecodesign & optimization of pump systems December 17, 2015

Webinar on Pumps & Circulators Agenda Ecodesign regulation on Water pumps Savings potential, scope and type definitions Ecodesign requirements & dates Test method & test standards involved Verification procedures and compliancy steps Ecodesign regulation on Circulators Savings potential, scope and definitions Ecodesign requirements & dates Test method & test standards involved Verification procedures and compliancy steps Live session Calculation example by screen sharing, The MST-Tool Q&A, End of webinar

Webinar on Pumps & Circulators December 17, 2015 Online, Internet Sandie B. Nielsen (sbn@dti.dk) Danish Technological Institute Electrical Engineer (1996) - Drives specialist, programmer Employments: 1996-2001 ABB (Drives specialist) 2001-2002 DEFU (Multiple Energy Projects) 2002- present: Danish Technological Institute Multiple Energy Projects Technical consultant for Danish Energy Agency (ECO-design motors, pumps) External Trainer at Grundfos A/S (pumps and pump applications) DAQ software development Head of accredited testing laboratories for motors, pumps & circulators Task leader in EMSA since 2009 IEC TC22G WG18 member Drives efficiency (Internationalization of EN 50598 series)

Water pumps Introduction Ecodesign regulation on water pumps was first decided and published in the Official Journal of the European Union in the summer of 2012 (No.: 547/2012) Based on European preparatory study Lot 11, finished February 2008 First tier came into force on January 1 st, 2013, The second: January 1 st, 2015 Estimated annual energy savings of 3.3 TWh by 2020 (Compared to no measures) This is a regulation focusing on the component! Isolated efficiency requirements in 3 duty points (without considering duty cycle / load profile)

Water pumps Scope Rotodynamic water pumps for pumping clean water, including where integrated in other products. Not in scope: Specifically designed for water below -10 C and above 120 C Specifically designed for fire-fighting Displacement water pumps Self-priming water pumps

Water pumps Scope End suction pumps Design pressure < 16 bar 6 rpm < n s < 80 rpm Rated flow > 6 m 3 /h Max shaft power 150 kw Max head 90m (1450 rpm) Max head 140m (2900 rpm) Vertical mounted end suction Vertical Multistage Pumps Design pressure < 25 bar No. of stages > 1 Compliancy test with i=3 Nominal speed = 2900 rpm Rated flow < 100 m 3 /h Not only in-line! Submersible Multistage Pumps No. of stages > 1 Compliancy test with i=9 Nominal Ø out = 4 Nominal speed = 2900 rpm 0 C < Operating < 90 C

Water pumps Ecodesign requirements & dates From January 1 st, 2013: At best efficiency point have at least (η ΒΕΡ ) min requ, when calculated with the C-value for MEI = 0.1 At part load point have at least (η ΡL ) min requ, when calculated with the C-value for MEI = 0.1 At overload point have at least (η OL ) min requ, when calculated with the C-value for MEI = 0.1 Meet various product information demands (1-15) including: Minimum efficiency index: MEI [x,xx], year of manufacture etc. From January 1 st, 2015: Same first three points as above, but with the C-value for MEI = 0.4

Water pumps Test results Test method Requirements from regulation House of efficiency Test standards used: ISO 9906:2012 The bible of pump testing pren 16480 Dedicated standard for ecodesign (incl. cross references etc.)

Water pumps Test method, step 1 Full pump curve Many duty points Around expected BEP

Water pumps Test method, step 2 Dismantle pump & partial motor curve Efficiency as function of input power

Water pumps Test method, step 3 Hydraulic efficiency curve (motor excluded)

Water pumps Test method, pre-step 4 Calculation of requirements & compliancy check New requirement is 4.24 % point higher

Water pumps Test method, step 4 Calculation of requirements & compliancy check

Circulators Introduction Ecodesign regulation on circulators was first decided and published in the Official Journal of the European Union in the summer of 2009 (No.: 641/2009) Based on European preparatory study Lot 11, finished February 2008 First tier came into force on January 1 st, 2013, The second: August 1 st, 2015 Estimated annual energy savings of 23 TWh by 2020 (Compared to no measures) This is a regulation focusing on the extended product (motor, control, pump, duty points) Weighted power consumption in 4 duty points (Taking duty cycle / load profile into account) The regulation was amended in the summer of 2012 due to Loop hole problems! (EU regulation no.: 622/2012)

Circulators Scope Glandless standalone circulators and glandless circulators integrated in products. Rated hydraulic power between 1 W and 2.500 W Not in scope: Drinking water circulators (except for product information) Identical replacement circulators in products Placed before August 1 st, 2015 Until January 1 st, 2020

Circulators Ecodesign requirements & dates From January 1 st, 2013: Glandless standalone circulators, with the exception of those specifically designed for primary circuits of thermal solar systems and of heat pumps, shall have an energy efficiency index (EEI) of not more than 0.27 Meet various product information demands including: Energy Efficiency Index: EEI 0.[xx], Benchmark most efficient etc. From August 1 st, 2015: Glandless standalone circulators and glandless circulators integrated in products shall have an energy efficiency index (EEI) of not more than 0.23 Also integrated circulators shall meet various product information demands including: Energy Efficiency Index: EEI 0.[xx]

Circulators Test method Weighted power consumption in 4 duty points compared to a reference power P ref Test standards used: ISO 9906:2012 The bible of pump testing DS/EN 16297 series Dedicated standards for ecodesign (incl. cross references etc.)

Circulators Test method, step 1 Full pump curve on max speed

Circulators Test method, step 2 4 part load duty points

Circulators Test method, step 3 4 part load duty points 4 x measured power Blaue Ängel weighting Final EEI = 0.20; Passed

Webinar on Pumps & Circulators Time for live calculation But first a short intro Blaue Ängel weighting 6000 h/y: 100% - 360h 75% - 900h 50% - 2100h 25% - 2640h

Webinar on Pumps & Circulators Thank you for listening Contacts: Sandie B. Nielsen: sbn@dti.dk Danish Technological Institute: http://dti.dk 4E EMSA Electrical Motor Systems Annex, http://motorsystems.org