ecocirc PREMIUM Series ErP 2009/125/EC 50/60 Hz motralec WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS Cod.

Similar documents
50/60 Hz. ecocirc PREMIUM Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

ecocirc BASIC Series ErP 2009/125/EC 50/60 Hz WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS Cod Rev. B Ed.

50/60 Hz. ecocirc BASIC Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS. ErP 2009/125/EC

50 Hz. TLCN, TLCHN Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS

ECOCIRC Series. ErP. 50/60 Hz HIGH EFFICIENCY CIRCULATORS FOR DOMESTIC HEATING. ready. Cod Rev. .A Ed.10/2012

50 Hz. ecocirc PRO Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS. Cod Rev

50 Hz. ecocirc PRO Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS DE: +41 (0) FR: +41 (0) Rev. Cod.

NCE Energy saving circulating pumps

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

Series description Wilo-Drain STS 40

In-line Twin Pump. Type Series Booklet. Omega DSL

Flygt 3171, 50Hz. Technical Specification

The e-gs 4" Range. Lenntech. Tel Fax

Flygt 3057, 50Hz. Technical Specification

b) General instructions and documents to be submitted by an interested company:

60 Hz. VM Series CLOSE-COUPLED THREADED VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS EQUIPPED WITH IE3 MOTORS COMPLYING WITH IEC

e-hm TM Series HM..P - HM..S - HM..N 60 Hz

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Flygt 3057, 50Hz. Technical Specification

N-pump, Standard Motor

Autogas Series. Regenerative Turbine Coro-Flo Pumps For High Differential Pressure Applications Using LPG and Other Liquefied Gases.

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

Xylem VSD Payback Tool

HM - HMZ - HMS Series. 50 Hz

HM - HMS Series. 60 Hz

CIVIL/INDUSTRIAL. water solutions. Grey. series SUBMERSIBLE ELECTRIC PUMPS FOR DRAINAGE, CIVIL AND INDUSTRIAL LIFTING SYSTEMS. zenit.

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3)

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

EC medium pressure axial fans.

griswold EF&G Heavy Duty end suction

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

GRUNDFOS INDUSTRIAL SOLUTIONS. Grundfos CM CM/CME COMPACT PUMPS FOR DEMANDING APPLICATIONS

Weir Specialty Pumps. WEMCO Torque-Flow

Drain Taps, Gland Cocks, De-Aerators and Air Vents

Sulzer Pumps New Stock Pumping Concept

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

The right partner for your project. Drainage and water supply

Model EVMS Vertical Multistage Pumps for the Global Market

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

Experior as an Energy Savings Solution for Wastewater Lift Stations. Lisa Riles NA Marketing and Business Development Manager Xylem

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

GRAVOTECH GROUP. Complete range of Integrable Fiber Laser Marking Solutions LASER SOLUTION F-SERIES.

Rolairtrol Air Separator For Hot and Chilled Water Systems

Flygt C-pumps Submersible waste and raw water pumps

Richter Sealless Chemical Magnetic Drive Pumps

Horizontal and Vertical End Suction Pumps

Introduction. Ultra Reliable

Flanged Water Meters (non-continuous flow)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. Vertical Sump Pumps

Gr i s w o l d. Ren e w a b l e Br o n z e. The renewable bronze shaft sleeve insulates the shaft from abrasion and contact with pumped liquids.

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86

GRUNDFOS SUBMERSIBLES. Grundfos submersible pumps the complete solution

trusted innovative expertise

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100

GRAVOTECH GROUP FIBRE LASER. Complete range of integrable laser marking systems LASER SOLUTION F-SERIES.

VOGEL - Submersible Pumps in Stainless Steel Design TVS

HIGH- EFFICIENCY IN-LINE PUMPS

3-speed technology The power of flexibility

TDC46M Carbon Steel Thermodynamic Steam Trap with Maintainable Seat

Technical specification. Flygt N 3301, 50 Hz

GOULDS PUMPS. Commercial Water. e-sv General Market Specifications. Applications. Specifications

SECTION SLUDGE HOLDING TANK DECANTER PUMP

Aqua-Recycling-Control 80B Plus

Model B. Thermostatic Control Valves. Typical applications

NM, NMS. Close Coupled Centrifugal Pumps with flanged connections. Construction. Applications. Operating conditions. Motor

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

It s All a Matter of TechNiQ. NiQ: Our latest generation of energy-saving motors.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

PCM DELASCO. Peristaltic pumps Series DSC 65, 80, 100

Energy Effiency of Circulators

ROOTS VACUUM PUMPS RSV SERIES

Close Coupled Sump Pumps Type ETLB

V MW. One turbine for one world. vestas.com

T U R B O B L O W E R S

Series Sump and Sewage Systems

Model B. Thermostatic Control Valves. Typical applications

4 1 /2 MARK 73-5 AMERICAN FLOW CONTROL. It s What We Know. AMERICAN-DARLING FIRE HYDRANT AMERICAN-DARLING 4 1 /2 MARK 73-5 FIRE HYDRANT

02V11/04. Thermostatic Control Valve. B Valve. Key benefits. Typical applications

1/58 Components of solar systems

jung-process-systems.de Hygienic gentle economical

Booster Pump Fundamentals. By: Bill Baglot

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

A Green Solutions Company TM ENGINEERED PRODUCTS

INTERNATIONAL STANDARD

Pump down time for 5 l receiver

VIKING BOLTED-LID BASKET-TYPE LINE STRAINERS

Xylem Water Solutions AB (the Company) was previously named ITT Water & Wastewater AB. The name change took place in November 2011.

VERTICAL TURBINE PUMPS

Technical specification. Flygt N 3127, 50 Hz

Underground fire hydrants

e-hmseries STAINLESS STEEL HORIZONTAL MULTI-STAGE PUMPS BROeHM R2

Transcription:

/ Hz motralec rue Lavoisier. ZA Lavoisier. 9 HERBLAY CEDEX Tel. :.9.9.. / Fax. :.9.9.8.8 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com ecocirc PREMIUM Series WET ROTOR CIRCULATORS FOR HEATING, COOLING AND SANITARY SYSTEMS ErP 9//EC Cod. 9 Rev ev.a Ed./

ecocirc PREMIUM SERIES INSTALLA ALLATION POSITIONS Lowara, ecocirc, Xylect are trademarks of Xylem Inc. or one of its subsidiaries.

High efficiency circulators for domesting heating ecocirc PREMIUM Series MARKET SECTORS RESIDENTIAL. APPLICATIONS Water circulation in heating and air conditioning systems. Refurbishment or extension of existing systems. Recommended for facilities fitted with thermostatic valves. Single-family houses or apartment buildings. Floor heating systems. SPECIFICATIONS PUMP Flow rate: up to, m /h. Head: up to, m. Maximum power consumption: W (for the m model) and W (for the m model). Temperature of pumped liquid: - C + C. Avoid condensation and ice formation. Maximum % glycol and water mixture. For glycol quantities higher than %, hydraulic performances must be checked. Maximum operating pressure: bar (PN ). Rotor assembly group: made of stainless steel/composite material/carbon. *) ErP ready L'alta efficienza del domani è disponibile adesso: i nuovi circolatori Ecocirc sono conformi alla Direttiva ErP per il MOTOR Permanent magnet EC (Electronically Commutated) type motor with spherical rotor/stator. Wet rotor with a single spherical ceramic/carbon bearing. Integrated motor protection; no external protection required. Single-phase - V / Hz power supply. Variable-speed motor, with automatic speed adjustment based on system requirement. Insulation class F ( C). Protection class IP. *) model -/ excluded.

ecocirc PREMIUM Series CONSTRUCTION CHARACTERISTICS Improved hydraulics to improved efficiency. The cast iron pump housing is cataphoresis coated completely and is therefore resistant to corrosion. The spherical rotor. The permanent magnet rotor/impeller unit is the only moving part. Spherical motor pumps are shaftless, and therefore whisper quiet over the whole lifetime. In case of an indicated rotor blocking, emergency software shakes and vibrates the rotor to avoid further blocking. Anti-Block-Technology allows to separate the magnetic chamber from the flow, preventing magnetite and sludge to block and damage the pump. Blocking up, even in very old, open systems is impossible by our pump design. Three in one control: - step-less manually control constant speed, (displayed by a white LED), - automatic differential pressure, (displayed by a blue LED), - automatic constant pressure, (displayed by a green LED). Digital multi-display that shows automatically and alternatively power consumption (Watt), head (m), and flow-rate (m /h). The display provides also detailed information on the air purge mode status as well as detailed error messages. Optimized motor technology: Doubled electric windings combined with the latest Bit processor technology - that also makes the Ecocirc even more efficient. Overtemperature protection feature that slows down the circulator in case the temperature of the electronic module is too high and shuts it down when temperature rises above the safety limit. The circulator will automatically restart after having cooled down. Always easy to access: The screw ring design results in a pump motor that can be rotated in any position around the circle. The electrical connection as well as the control knob is therefore easy to access. Plug an easy and quick electrical connection. By turning the stator via the screw ring the plug can be fixed in any position, making the installation even in the hardest and tightest environment easy. Automatic air purge: Quick automatic air-venting-mode for a safe operation. According to EN standards -, --, -, -, 9-, 9-. CONTROL MODES Automatic regulation: the pump automatically adjusts the working conditions based on the requirement of the system. When the pump detects a decrease in the flow, the inverter reduces the differential pressure of the pump until it reaches the required head. ACCESSORIES SORIES Pipe unions. Insulation shell. INSTALLA ALLATION Suitable for installation in vertical or horizontal piping, in this last case not with the motor housing upward.

ecocirc PREMIUM SERIES IDENTIFICATION TION CODE / PORT TO PORT DISTANCE IN mm. MAXIMUM HEAD IN m. PORT NOMINAL DIAMETER SERIES NAME EXAMPLE : -/ Electronic circulator of the series, port nominal diameter =, max head = m, with port to port distance mm. TABLE OF MATERIALS PART MATERIAL Pump body Rotor assembly group Bearing Gaskets Motor housing Screw ring Plug Cast iron ( EN-GJL- ) cataphoretically coated Stainless steel Composite material Carbon Ceramics EPDM Rubber Aluminum ( AlSiCu ) Aluminum ( AlMgSi ) Polyamide ecocircp--en_a_tm Regulations (EC) n. /9 and (EU) n. / Annex I point (Product information requirements) a) Energy efficiency index: see the EEI column in the tables in the Hydraulic performance section. b) The benchmark for most efficient circulators is EEI,. c) Information relevant for disassembly, recycling or disposal at end-of-life: observe the current laws and by-laws governing sorted waste disposal. Consult the product operating manual. d) Information for circulators specifically designed to potable water uses: note not applicable to these products.

ecocirc PREMIUM.../ SERIES HYDRAULIC PERFORMANCE TABLES (CONSTANT SPEED) PUMP POWER SPEED Q = DELIVERY TYPE EEI ABSORBED l/s,,,,,8,,,,9 MIN MAX m /h,,,,8,,,,, V Hz () W W H = TOTAL HEAD METRES COLUMN OF WATER -/ -/ -/ -/8 -/8,,,,, min max,,,,,,9,,,,8, Performances according to standards EN 9-. () Energy efficiency index. ecocircp-c--en_b_th (PROPORTIONAL PRESSURE) SURE),,,,, PUMP POWER CURRENT SPEED Q = DELIVERY TYPE EEI ABSORBED ABSORBED l/s,,,,,8,,,,9 MIN MAX MIN MAX m /h,,,,8,,,,, V Hz () W W A A (CONSTANT PRESSURE) SURE) H = TOTAL HEAD METRES COLUMN OF WATER, -/ -/ -/ -/8 -/8,,,,,,9,8 min,,,,9,,,9 max,,,9,,,,,,8, Performances according to standards EN 9-. () Energy efficiency index. ecocircp-p--en_b_th

ecocirc PREMIUM.../ SERIES SINGLE-PHASE OPERATING CHARACTERISTICS -/ - -/8 -/ - -/8 - -/ EN 9- -/ - -/8 -/ - -/8 - -/ EN 9-8 Q [Imp gpm] 8 Q [Imp gpm] H [m] 8 Q [US gpm] H [ft] H [kpa] H [m] 8 Q [US gpm] H [ft] H [kpa] 8 8 P [W] P [W],,,,,, Q [m /h],,,,, Q,8[l/s] 98C_E_CH,,,,,, Q [m /h],,,,, Q,8[l/s] 98P_E_CH -/ - -/8 -/ - -/8 - -/ EN 9-8 Q [Imp gpm] H [m] 8 Q [US gpm] H [ft] H [kpa] 8 P [W],,,,,, Q [m /h],,,,, Q,8[l/s] 98PC_A_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec. Pump operates steplessly. Lines correspond to knob settings and are for reference only.

ecocirc PREMIUM.../ SERIES HYDRAULIC PERFORMANCE TABLES (CONSTANT SPEED) PUMP POWER SPEED Q = DELIVERY TYPE EEI ABSORBED l/s,,,,,,,,9,89 MIN MAX m /h,,,,8,,,,, V Hz () W W H = TOTAL HEAD METRES COLUMN OF WATER -/ -/ -/ -/8 -/8,*,,,, min,,,,,, max,9,,,,,,,, Performances according to standards EN 9-. () Energy efficiency index. * ErP ready ecocircp-c--en_b_th (PROPORTIONAL PRESSURE) SURE) (CONSTANT PRESSURE) SURE) PUMP POWER CURRENT SPEED Q = DELIVERY TYPE EEI ABSORBED ABSORBED l/s,,,,,8,,,9,8 MIN MAX MIN MAX m/h,,,,8,,,,, V Hz () W W A A H = TOTAL HEAD METRES COLUMN OF WATER,9 -/ -/ -/ -/8 -/8,*,,,,,9, min max,,,,8,9,8,,,,,,8,,,9,, Performances according to standards EN 9-. () Energy efficiency index. * ErP ready ecocircp-p--en_b_th 8

ecocirc PREMIUM.../ SERIES SINGLE-PHASE OPERATING CHARACTERISTICS -/ - -/8 -/ - -/8 - -/ EN 9- -/ - -/8 -/ - -/8 - -/ EN 9-8 Q [Imp gpm] 8 Q [Imp gpm] H [m] 8 Q [US gpm] H [ft] H [kpa] 8 Q [US gpm] H [m] H [ft] H [kpa] P [W] P [W],,,,,,,Q [m /h],,,,,,8 Q [l/s] 98C_E_CH,,,,,, Q [m, /h],,,,,,8 Q [l/s] 98P_E_CH -/ - -/8 -/ - -/8 - -/ EN 9-8 Q [Imp gpm] H [m] 8 Q [US gpm] H [ft] H [kpa] P [W],,,,,, Q [m, /h],,,,,,8 Q [l/s] 98PC_A_CH These performances are valid for liquids with density ρ =. Kg/dm and kinematic viscosity ν = mm /sec. Pump operates steplessly. Lines correspond to knob settings and are for reference only. 9

ecocirc PREMIUM SERIES DIMENSIONS AND WEIGHTS.../ TABLE PUMP TYPE.../ TABLE PUMP TYPE DIMENSIONS (mm) DIMENSIONS (mm) WEIGHT H H D F DN kg -/ Rp /" G ",9 -/ Rp /" G "¼, -/ Rp " G "½, -/8 8 9 Rp " G "½, -/8 8 9 Rp "¼ G ", ecocircp-p-en_a_td WEIGHT H H D F DN kg -/ Rp /" G ",9 -/ Rp /" G "¼, -/ Rp " G "½, -/8 8 9 Rp " G "½, -/8 8 9 Rp "¼ G ", ecocircp-p-en_a_td

DOCUMENTATION TION

FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect TM Xylect TM is pump solution selection software with an extensive online database of product information across the entire Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara and Vogel products. The search can be made by: Application Product type Duty point Xylect TM gives a detailed output: List with search results Performance curves (flow, head, power, efficiency, NPSH) Motor data Dimensional drawings Options Data sheet printouts Document downloads incl dxf files The search by application guides users not familiar with the product range to the right choice. TECHNICAL APPENDIX

FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect TM The detailed output makes it easy to select the optimal pump from the given alternatives. The best way to work with Xylect TM is to create a personal account. This makes it possible to: Set own standard units Create and save projects Share projects with other Xylect TM users Every user have a My Xylect space, where all projects are saved. For more information about Xylect TM please contact our sales network or visit www.xylect.com. Dimensional drawings appear on the screen and can be downloaded in dxf format. TECHNICAL APPENDIX

motralec rue Lavoisier. ZA Lavoisier. 9 HERBLAY CEDEX Tel. :.9.9.. / Fax. :.9.9.8.8 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com