Ceiling Attenuation Class Systems SYSTEMS 280

Similar documents
InterHome SEPARATING WALL SYSTEM FOR MULTI-RESIDENTIAL CONSTRUCTION

Timber Separating Walls 3.3.3

Product Properties. Fire Resistant. Water Resistant. Sound Resistant. Sound Absorbing. Impact Resistant. Interior Design.

Knauf MF Suspended Ceilings

WALL CEILING FACADE ACCESSORIES ACCESS PANELS CONTACT CLICK TO START

Knauf C-Form Suspended Ceilings

June Non - Residential New Build Partition walls

External Steel Stud and Top Hat Walls. Details SYSTEMS 176 NON-FIRE RATED SYSTEMS 176 FIRE RATED SYSTEMS 178 BRICK VENEER SYSTEMS 183 INSTALLATION 185

ROCKWOOL FLEXI Insulation Application Guide

Technical Supplement. Internal Fire and Acoustic Rated Floor Solution INTERIORS

FIRE RATING MATERIAL FIXING NOTES

84 Symonds Street PO Box 5811 Wellesley Street Auckland 1141 New Zealand T: F:

Part E robustdetails. robustdetails. September 2015 Update Pack. Dear Colleague,

Components. Contents. Introduction. Applications. Linings. Introduction 2. Applications 2

Selecting floors and ceilings

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings

How glass or rock mineral wool works in a wall or floor cavity

GypLyner UNIVERSAL Concealed grid ceiling lining system

GypLyner UNIVERSAL (Ceilings)

SECTION D Masonry Wall Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications.

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

PROMAtect h concrete upgrade Concrete and brick walls

Typical detail: New roof with breathable underlay

GypLyner (Ceilings) Concealed grid ceiling lining system. GypLyner UNIVERSAL.

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

June Residential Refurbishment Separating floors

June Residential Refurbishment Separating walls

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

Concrete Soffit Direct Fix

Specialists in Acoustic Flooring and House to Flat Conversions

A Handbook of thermal bridging details incorporating aircrete blocks

Relationship between flanking noise through a common ceiling plenum and plenum absorption George van Hout, John Pearse and Brian Donohue

April Section Internal Walls

SEPARATING WALLS CLASS 1A

The Passive Fire Protection Handbook

June Non - Residential Refurbishment Separating floors

Wet Areas Using Plasterboard

THE RED BOOK. FIRE & ACOUSTIC DESIGN GUIDE Addendum July 2014 OVERVIEW GYPROCK SUPACEIL OPTIMISED CORE TECHNOLOGY APPLICATION

GypLyner UNIVERSAL Concealed grid ceiling lining system

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

CasoLine MF Concealed grid MF suspended ceiling system

Acoustic Performance of Light Steel Framed Systems

Carpentry/Carpenter CIP Task Grid

CasoLine MF Concealed grid MF suspended ceiling system

CI/SfB l l l Ym1 l (M2) l July Superior 4 in 1 insulation TIMBER FRAME SOLUTIONS GUIDE

Suspended timber upper floors

SECTION NON-STRUCTURAL METAL FRAMING

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

An introduction to Part L U-values

Fire resistance and acoustic properties

How to fill in your Timber Frame Order Form

Issue date: 15th January Key changes since original publication (July 2005):

R-Matte Plus-3: Insulation for the Building Envelope

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Why party wall insulation is required

SECTION E Ceiling Systems. Contents. Introduction. Design Considerations. Installation. Components. System Specifications. Floor/Ceiling Systems

April Section 4.3. Separating Floors

FIRE BARRIER SYSTEM Preventing the spread of fire and inhibiting the passage of smoke in concealed spaces

SECTION B Steel Frame Wall Systems. Contents. Steel Stud Selection Tables. Introduction. Design Considerations. Installation.

A Handbook of thermal bridging details incorporating aircrete blocks

Intertenancy Barrier Systems for Terrace Homes

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

Approved Document E Technical Design Report

Knauf Wall Liner. Head Track. Brackets. Wall Lining Stud. Fixings. Knauf Plasterboard. Floor Track. 98 Wall Liner

Loadbearing timber joist floors

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Cavity & Smoke Barriers, Parapet & Spandrel Walls

For inhibiting the spread of fire and smoke in concealed spaces

Guidance on U Values from Domestic Heating Design Guide

GypLyner IWL Independent wall lining system

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

Construction Technology Revision Guide

TIMBER FRAME HOUSING SOLUTIONS

SECTION GYPSUM BOARD SYSTEM

Benefits.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

EDGEWATER, FLORIDA JUNE 14, 2010

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Party Wall Design & Installation

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

SECTION GYPSUM BOARD SYSTEM

05 INTERIOR 0522p RONDO in partitions - framed and lined

Day Night Day Night Day Night Residential site and amphitheatre Green Non residential site boundary Red

4.1 Ground Floors. Ground floors. Ground floor design. Technical Support Team

Acoustic Design Criteria

Section 11 FIRE STOPPING

9/24/2015. Aalto! / ENG + ARC. Asuinrakennusten rakenneratkaisut. Requirements : Sound insulation requirements : Thermal insulation requirements :

GypLyner (walls) Metal framed wall lining system. GypLyner.

Standard Practice for Installing Sound-Isolating Lightweight Partitions 1

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

RSIC THE REVOLUTION IN NOISE CONTROL

Wall lining Inner leaf blockwork. K106 Cavity Board. Flexible sealant STANDARD DETAILS FOR 115 MM INSULATION BOARD IN A 125 MM CAVITY

*X227/12/01* X227/12/01 BUILDING CONSTRUCTION HIGHER NATIONAL QUALIFICATIONS 2014 FRIDAY, 6 JUNE 9.00 AM AM

fireseal Party Wall Design Guide CLASS 1 BUILDINGS PARTY WALL DESIGN GUIDE PAGE 1

Standard Practice for Architectural Application and Installation of Operable Partitions 1

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces

Start installing now

Building use, location etc. Option 1 Domestic type Pitched Roof 15, insulation at rafter line (heated habitable room) UV001 NOV 2015 (V2)

Transcription:

SYSTEMS 280 Ceiling Attenuation Class Ceiling Attenuation Class (CAC) ceiling systems display resistance to sound passing up and over a wall. The sound insulation rating given for the ceiling system indicates the sound reduction from one room to the next via the two ceilings and the above-ceiling plenum. Rather than introduce another term to building designers such as CAC, the more familiar terms Rw and Rw + Ctr are used. CAC systems without a central barrier must have a maximum of 1 downlight every 5 m 2 and other penetrations acoustically treated in the rooms adjacent to the wall are required to maintain sound insulation performance. [Refer to Section 3.1.1 Construction Details for wall to ceiling finishing details] 279

3.4.2 CEILING ATTENUATION CLASS SYSTEMS KCAC1-KCAC28 [Option 1] Suspended ceiling frame with set plasterboard ceiling [Option 2] T-bar exposed grid frame with ceiling tiles for system KCAC1 [All systems are suitable under a concrete slab, timber roof framing or steel roof framing] [Sound insulation numbers based on minimum 300mm cavity] [Penetrations in ceiling lining may degrade sound insulation performance] 300mm min cavity No Insulation ASB3 insulation above ceiling to 1200mm both sides of wall ASB3 insulation over entire ceiling KCAC1 1 layer of 10mm SpanGrid ceiling tiles in exposed grid 36 (30) 41 (35) 43 (37) KCAC10 1 layer of 10mm MastaShield or SpanShield 38 (32) 43 (36) 45 (38) KCAC11 2 layers of 10mm MastaShield or SpanShield 43 (37) 47 (41) 48 (42) KCAC14 1 layer of 13mm MastaShield 41 (34) 45 (38) 47 (40) KCAC16 1 layer of 10mm Opal 41 (34) 45 (38) 47 (40) KCAC17 2 layers of 10mm Opal 44 (38) 48 (42) 49 (43) KCAC18 1 layer of 13mm SoundShield 43 (36) 47 (40) 48 (41) KCAC19 2 layers of 13mm SoundShield 49 (42) 52 (45) 52 (45) KCAC20 1 layer of 13mm FireShield 43 (36) 47 (40) 48 (41) KCAC22 1 layer of 16mm FireShield 43 (36) 47 (40) 48 (41) KCAC23 1 layer of 13mm FireShield plus 1 layer of 16mm FireShield 49 (42) 52 (45) 52 (45) KCAC24 2 layers of 16mm FireShield 49 (42) 52 (45) 52 (45) KCAC26 3 layers of 13mm FireShield 51 (44) 53 (46) 53 (46) KCAC27 1 layer of 13mm FireShield plus 2 layers of 16mm FireShield 51 (44) 53 (46) 53 (46) KCAC28 3 layers of 16mm FireShield 51 (44) 53 (46) 53 (46) 4738-5 280 Technical Advice 1300 724 505 knaufmetal.com.au

CEILING ATTENUATION CLASS SYSTEMS 3.4.2 KCAC120-KCAC128 Set plasterboard ceiling divided by discontinuous wall frames and discontinuous joists or trusses [Double stud wall timber or steel frame with minimum 20mm air-gap] [All systems are suitable under roof or floor with timber or steel framing] [Sound insulation numbers based on minimum 300mm cavity] [Penetrations in ceiling lining may degrade sound insulation performance] FireShield No Insulation ASB3 insulation above ceiling to 1200mm both sides of wall ASB3 insulation over entire ceiling KCAC120 1 layer of 13mm FireShield 49 (43) 54 (46) 56 (48) KCAC121 2 layers of 13mm FireShield 52 (45) 58 (48) 59 (50) KCAC122 1 layer of 16mm FireShield 42 (43) 55 (46) 56 (48) KCAC123 1 layer of 13mm FireShield plus 1 layer of 16mm FireShield 52 (45) 58 (48) 59 (50) KCAC124 2 layers of 16mm FireShield 52 (45) 58 (48) 59 (50) KCAC126 3 layers of 13mm FireShield 51 (46) 59 (49) 60 (50) KCAC127 1 layer of 13mm FireShield plus 2 layers of 16mm FireShield 56 (47) 59 (50) 60 (50) KCAC128 3 layers of 16mm FireShield 56 (48) 59 (51) 60 (50) 4738-5 Technical 281 Advice 1300 724 505 knaufplasterboard.com.au 281

3.4.2 CEILING ATTENUATION CLASS SYSTEMS KCAC30-KCAC48 [Option 1] Suspended ceiling frame with set plasterboard ceiling [Option 2] T-bar exposed grid frame with ceiling tiles for system KCAC3 ABOVE [Option 1] 10mm minimum plasterboard on one side of stud only, continued up to concrete slab or roof lining [Option 2] 10mm minimum plasterboard fixed to concrete slab or roof lining with track or angle. Insulation placed above ceiling lining and held in place using track or angle. [All systems are suitable under a concrete slab, timber roof framing or steel roof framing] [Sound insulation numbers based on minimum 300mm cavity] Sealant Sealant 10mm min plasterboard on one side of wall only 300mm min cavity 10mm min plasterboard Track or angle to hold insulation in place 300mm min cavity No Insulation ASB3 insulation above ceiling to 1200mm both sides of wall ASB3 insulation over entire ceiling KCAC3 1 layer of 10mm SpanGrid ceiling tiles in exposed grid 41 (35) 46 (40) 48 (42) KCAC30 1 layer of 10mm MastaShield or SpanShield 45 (37) 50 (42) 52 (44) KCAC31 2 layers of 10mm MastaShield or SpanShield 51 (41) 54 (44) 56 (46) KCAC34 1 layer of 13mm MastaShield 47 (37) 52 (42) 54 (44) KCAC36 1 layer of 10mm Opal 48 (38) 52 (42) 54 (44) KCAC37 2 layers of 10mm Opal 52 (42) 55 (45) 57 (47) KCAC38 1 layer of 13mm SoundShield 49 (39) 53 (43) 55 (45) KCAC39 2 layers of 13mm SoundShield 53 (43) 56 (46) 57 (47) KCAC40 1 layer of 13mm FireShield 49 (39) 53 (43) 55 (45) KCAC42 1 layer of 16mm FireShield 50 (40) 54 (44) 56 (46) KCAC43 1 layer of 13mm FireShield plus 1 layer of 16mm FireShield 53 (43) 56 (46) 57 (47) KCAC44 2 layers of 16mm FireShield 53 (43) 56 (46) 57 (47) KCAC46 3 layers of 13mm FireShield 55 (45) 57 (47) 58 (48) KCAC47 1 layer of 13mm FireShield plus 2 layers of 16mm FireShield 55 (45) 57 (47) 58 (48) KCAC48 3 layers of 16mm FireShield 55 (45) 57 (47) 58 (48) 4738-5 282 Technical Advice 1300 724 505 knaufmetal.com.au

CEILING ATTENUATION CLASS SYSTEMS 3.4.2 KCAC50-KCAC68 [Option 1] Suspended ceiling frame with set plasterboard ceiling [Option 2] T-bar exposed grid frame with ceiling tiles for system KCAC5 ABOVE EarthWool or Polyester (minimum density 14 kg/m³) insulation baffle in 400mm wide strips to extend from ceiling to concrete slab or roof lining with no gaps or holes. [All systems are suitable under a concrete slab, timber roof framing or steel roof framing] [Sound insulation numbers based on minimum 300mm cavity] [Penetrations in ceiling lining may degrade sound insulation performance] 400mm min 300mm min cavity EarthWool or Polyester insulation (minimum density 14 kg/m³) above ceiling lining in 400mm minimum wide strips continued up to concrete slab or roof lining KCAC5 1 layer of 10mm SpanGrid ceiling tiles in exposed grid 43 (36) KCAC50 1 layer of 10mm MastaShield or SpanShield 45 (38) KCAC51 2 layers of 10mm MastaShield or SpanShield 52 (42) KCAC54 1 layer of 13mm MastaShield 50 (40) KCAC56 1 layer of 10mm Opal 50 (40) KCAC57 2 layers of 10mm Opal 53 (43) KCAC58 1 layer of 13mm SoundShield 51 (41) KCAC59 2 layers of 13mm SoundShield 53 (43) KCAC60 1 layer of 13mm FireShield 51 (41) KCAC62 1 layer of 16mm FireShield 51 (41) KCAC63 1 layer of 13mm FireShield plus 1 layer of 16mm FireShield 53 (43) KCAC64 2 layers of 16mm FireShield 53 (43) KCAC66 3 layers of 13mm FireShield 54 (44) KCAC67 1 layer of 13mm FireShield plus 2 layers of 16mm FireShield 54 (44) KCAC68 3 layers of 16mm FireShield 54 (44) 4738-5 Technical Advice 1300 724 505 knaufplasterboard.com.au 283

3.4.2 CEILING ATTENUATION CLASS SYSTEMS KCAC70-KCAC88 [Option 1] Suspended ceiling frame with set plasterboard ceiling [Option 2] T-bar exposed grid frame with ceiling tiles for system KCAC7 ABOVE Loaded vinyl sound insulation curtain (4 kg/m²) above wall to extend from ceiling to concrete slab or roof with no gaps or holes. (minimum density 11 kg/m³) or ASB3 insulation placed above ceiling lining [All systems are suitable under a concrete slab, timber roof framing or steel roof framing] [Sound insulation numbers based on minimum 300mm cavity] Loaded vinyl acoustic curtain 4 kg/m 2 300mm min 300mm min cavity 600mm min Loaded vinyl sound insulation curtain 4 kg/m² with ASB3 insulation above ceiling lining in a 600mm min wide strip KCAC7 1 layer of 10mm SpanGrid ceiling tiles in exposed grid 44 (38) KCAC70 1 layer of 10mm MastaShield or SpanShield 47 (40) KCAC71 2 layers of 10mm MastaShield or SpanShield 52 (42) KCAC74 1 layer of 13mm MastaShield 50 (40) KCAC76 1 layer of 10mm Opal 50 (40) KCAC77 2 layers of 10mm Opal 53 (43) KCAC78 1 layer of 13mm SoundShield 51 (41) KCAC79 2 layers of 13mm SoundShield 54 (44) KCAC80 1 layer of 13mm FireShield 51 (41) KCAC82 1 layer of 16mm FireShield 52 (42) KCAC83 1 layer of 13mm FireShield plus 1 layer of 16mm FireShield 54 (44) KCAC84 2 layers of 16mm FireShield 54 (44) KCAC86 3 layers of 13mm FireShield 55 (45) KCAC87 1 layer of 13mm FireShield plus 2 layers of 16mm FireShield 55 (45) KCAC88 3 layers of 16mm FireShield 55 (45) 3094-40 284 Technical Advice 1300 724 505 knaufmetal.com.au

CEILING ATTENUATION CLASS SYSTEMS 3.4.2 KCAC130 10mm minimum plasterboard [Sound Insulation numbers based on minimum 200mm cavity] No Insulation Minimum R1.5 EarthWool over the ceiling in adjacent cavities or 1200mm from wall KCAC130 1 layer of 10mm MastaShield or SpanShield 60 (50) 64 (54) 4738-16 Technical Advice 1300 724 505 knaufplasterboard.com.au 285

3.4.2 CEILING ATTENUATION CLASS SYSTEMS KCAC140 10mm minimum plasterboard [Masonry minimum 90mm brick or 140mm unfilled concrete block] [Sound insulation numbers based on minimum 200mm cavity] Masonry min 90mm Brick or 140mm Unfilled Block Knauf Masonry wall system with required sound insulation rating No Insulation Minimum R1.5 EarthWool over the ceiling 1200mm from wall 4738-16 KCAC140 1 layer of 10mm MastaShield or SpanShield 58 (48) 60 (50) 286 Technical Advice 1300 724 505 knaufmetal.com.au

CEILING ATTENUATION CLASS SYSTEMS 3.4.2 KCAC141 13mm FireShield and 16mm FireShield on clips and furring channel with a minimum 40mm cavity to the underside of the joists, rafters or trussers. [Sound insulation numbers based on minimum 200mm cavity] [Non-acoustic penetrations in ceiling lining may degrade sound insulation performance] (Rw + Ctr) Minimum R1.5 EarthWool over the ceiling 1200mm from wall PKA 215 085 KCAC141 13mm FireShield and 16mm FireShield (50) Technical Advice 1300 724 505 knaufplasterboard.com.au 287

3.4.2 CEILING ATTENUATION CLASS SYSTEMS KCAC150-KCAC151 10mm minimum plasterboard [Sound insulation numbers based on minimum 200mm cavity] 75mm Compleo AAC panel 100mm between soffit and nogging Minimum 200mm cavity System Knauf plasterboard Knauf plasterboard to extend above ceiling level FIGURE????? Label???? Airborne Sound Insulation Plasterboard Ceiling Lining Selected finishing detail Insulation in stud cavity to extend to ceiling level No Insulation Min 11 kg/m 3 (min. 600mm on both sides of wall) KCAC150 10mm MastaShield or 10mm SpanShield 45 (40) 50 (45) 5008.10-1 KCAC151 13mm MastaShield 50 (45) 55 (50) 288 Technical Advice 1300 724 505 knaufmetal.com.au

CEILING ATTENUATION CLASS SYSTEMS 3.4.2 KCAC160 13mm FireShield and 16mm FireShield on clips and furring channel with a minimum 40mm cavity to the underside of the joists, rafters or trussers. [Sound insulation numbers based on minimum 200mm cavity] [Non-acoustic penetrations in ceiling lining may degrade sound insulation performance] (Rw + Ctr) Minimum R1.5 EarthWool over the ceiling 1200mm from wall PKA 215 085 KCAC160 13mm FireShield and 16mm FireShield (50) Technical Advice 1300 724 505 knaufplasterboard.com.au 289