PR-09 PlantPAx TM : Field Device Interface and Asset Management Copyright 2012 Rockwell Automation, Inc. All rights reserved.
Agenda Process Device Architectures Integration Office Process Instruments Process Device Connectivity Lab Overview 2
Automation for the Process Industry Field Device Integration & Asset Management System Core Process Information Batch Management & Control System Migration Tools Process Optimization Critical Control & Safety
Process Networks & Asset Management Copyright 2012 Rockwell Automation, Inc. All rights reserved. 4
Process Networks & Asset Management Copyright 2012 Rockwell Automation, Inc. All rights reserved. 5
Process Instruments Today PT100 has a loose wire I Need attention Smart instrumentation and intelligent I/O bridge the traditional separation between automation systems and field devices Results of using intelligent devices Network-based instrument configuration Increased diagnostic coverage Predictive and enhanced preventive maintenance Remote servicing
Digital Communication READ PV: Mass Flow Rate SV: Totalizer 1 TV: Density FV: Temperature Volume Flow Std. Volume Flow Target Flow Carrier Flow Calculated Density Totalizer 2 Write Set Flow Units Reset Totalizers Set Range Zero & Full Scale Change K Factor Change Pipe Diameter Set Flow Direction Set Low Flow Cutoff Make Density Adjustments Over 32 Million Intelligent Process Devices Sold (ARC, 2007) Flow, Pressure, Temp, Level, Analytical and Valve Positioners
Integration Office Copyright 2012 Rockwell Automation, Inc. All rights reserved.
What is the Rockwell Automation Integration Office? Traditionally, the Integration Office was created to ensure PlantPAx works seamlessly with process devices. Today, the Integration Office provides preferred integration with our key partners. Tools created include integration documents, user manuals and sample configuration. The documents that the Integration Office produces are supported by our partners support organizations and also Rockwell Automation s tech support team. Key Partners include: E+H Other Partners (Metso Valves, Masoneilan Valves, P+F, etc)
Integration Tools Simplify Implementation of Smart Devices Add-On Instructions and Global Objects Faceplates Integration Documents Application Notes
Device Integration Tools Integration Document Details on field instrument and control system System specifications Installation how to: Connect instrument to network interface Configuration how to: Configure network interface Configure instrument Visualization Add-On Instructions and Faceplates http://www.rockwellautomation.com/solutions/process/integrationdocs.html Copyright 2012 Rockwell Automation, Inc. All rights reserved.
Device Integration Tools Add-On Instructions (AOI) and Faceplates Pre-designed AOIs provide a two-way exchange of data between the faceplates and the ControlLogix controller FactoryTalk View SE faceplates provide visualization of instruments connected to a 1756-IF8H HART module
FDT Technology: An Asset Management Enabler Copyright 2012 Rockwell Automation, Inc. All rights reserved. 14
The Three Letter Acronyms Copyright 2012 Rockwell Automation, Inc. All rights reserved.
FDT (Field Device Tool) Group FDT goal is to provide customers with better solutions via open standards. FDT uses proven Microsoft Windows standards. FDT is not a new digital bus or protocol. FDT has no allegiance to any one specific bus protocol. FDT is supported by over 70 users and manufacturers.
FDT Membership Copyright 2012 Rockwell Automation, Inc. All rights reserved.
Why Do I Need FDT Technology? FDT Technology enables end-users to integrate certified intelligent field devices into a single operations, maintenance and life cycle management environment
Lab Overview Copyright 2012 Rockwell Automation, Inc. All rights reserved. 19
PlantPAx HART Lab Overview 1. Setup Logix Project (Controller and IO) with RSLogix 5000. 2. Download Project to Controller using RSLogix 5000. 3. Setup Pop-up Faceplate on a Graphic Display using FactoryTalk View Studio. 4. Open the modified Graphic Display in FactoryTalk View SE Client and View Faceplate Parameters. 5. Configure the HART CerabarS using Process Device Configuration (PDC) in FactoryTalk AssetCentre. 6. Open ProCal in FactoryTalk AssetCentre and perform a mock calibration.
PlantPAx Foundation Fieldbus and Profibus PA Lab Overview 1. Configure the CerabarS and EN2FFR or EN2PAR connections. 2. Download the 1788-EN2FFR or EN2PAR configuration. 3. Setup Logix Project (Controller and Linking Device) with RSLogix 5000. 4. Download Project to Controller using RSLogix 5000. 5. Setup Faceplate on a Graphic Display using FactoryTalk View Studio. 6. Open Graphic Display in FactoryTalk View SE Client and view Faceplate parameters. 7. View FF Instrument Configuration with PDC in FactoryTalk AssetCentre. 8. Open ProCal in FactoryTalk AssetCentre and Perform a Mock Calibration.
Useful Web Sites Fieldbus Foundation www.fieldbus.org HART Communication Foundation www.hartcomm.org PROFIBUS Organization www.profibus.com/ FDT Group www.fdtgroup.org
Questions? Copyright 2012 Rockwell Automation, Inc. All rights reserved.
Thank you for participating! Please remember to tidy up your work area for the next session. We want your feedback! Please complete the session survey! Follow ROKAutomation on Facebook & Twitter. Connect with us on LinkedIn. www.rockwellautomation.com Copyright 2012 Rockwell Automation, 24 Inc. All rights reserved.