University of Delaware

Similar documents
The City Of Winnipeg R1. St. Vital Park Pavilion Page 1 of 9

SECTION PLUMBING FIXTURES

1.04 SUBMITTALS PLUMBING FIXTURES

1. Section "Residential Plumbing Fixtures" for residential sinks.

Gas Station & C Store SECTION CWM Job No

.1 Capped for future connection by others. .2 Section Waste Management and Disposal.

.1 Capped for future connection by others. .2 Section Waste Management and Disposal.

SECTION PLUMBING FIXTURES

PLUMBING FIXTURES

The University of North Carolina at Charlotte

SECTION PLUMBING FIXTURES

SECTION PLUMBING FIXTURES. A. This specification describes the requirements for plumbing fixtures and their installation.

Element D Services Plumbing

October 4, 2013 Construction Set OR RENOVATIONS BID PACKAGE 2 SECTION PLUMBING

03.01 DESIGN REQUIREMENTS

CONTINUED ON FOLLOWING PAGE

SECTION PLUMBING FIXTURES

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

University of Delaware

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION PLUMBING SPECIALTIES

PIPING SPECIALTIES (PLUMBING) A. American Society for Testing and Materials (ASTM):

DESIGN AND CONSTRUCTION STANDARDS _ April 2018

SECTION PLUMBING EQUIPMENT AND SPECIALTIES

Essex County College - West Essex Campus Addition And Renovations Dib # / SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION PLUMBING PIPING INSULATION

optional parts for geberit Duofix carrier

Technology. Enabling Design. Geberit Duofix Carrier

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

PLUMBING SYSTEMS SECTION Complete sanitary waste and vent systems. 2. Complete domestic hot and cold water systems.

City of Galena Request for Quotes for Plumbing Work at Train Depot, 101 Bouthillier Street Quotes Due: 10 am on Wednesday 6 December 2017

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

University of Delaware

Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this

University of Delaware

A. This Section includes the following sanitary drainage piping specialties:

PLUMBING. 1. New kitchen sinks and vanity sinks in residential units; new accessible showers and tubs in residential units and public showers.

Bid Package 22A Plumbing Systems

Refer to Part 4 Section D20 for performance requirements of the building elements included in the plumbing system.

SECTION PLUMBING PIPING SYSTEMS

SECTION PLUMBING PIPING SYSTEM

MIFAB SAMPLE FIXTURE SCHEDULE & SPECIFICATIONS

SECTION PLUMBING SPECIALTIES

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

BATH HOUSE STRUCTURE FOR: HOLLAND PARK

MATHIS WALL-MOUNT FAUCET

***NOTE BID DATE CHANGE***

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL SECTION PLUMBING SYSTEMS

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

MECHANICAL SPEC 1/6 MECHANICAL SPECIFICATIONS

MODELS: SM & SMSS

C. Up to Two and One-half (2-1/2) inches: Full port, 2-piece, bronze body ball valves with teflon seat conforming to MSS SP-110.

SECTION BASIC FIRE SUPPRESSION MATERIALS AND METHODS. A. Section includes pipe, fittings, valves, and connections for sprinkler systems.

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

DIVISION 22 PLUMBING

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

A. Section Joint Sealers: Seal fixtures to walls and floors. A. ANSI Z American National Standard for Plastic Shower Units: 1995.

Student Services & Classroom Addition. A. This Section includes the following domestic water piping specialties:

TENOCHCA HALL - PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

C. Inspect all waster lines and repair all joints that are leaking. Replace all damaged or broken drain lines.

Texas Tech University Health Sciences Campus - MSBII Supplemental Bid Instructions March 3, 2017

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

SECTION PIPING SPECIALS

SUPPORT AND ANCHORS SECTION 15090

for Crestview Homes, Inc. Plumbing Fixture Package C

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Construction Standards PAGE

Certification Record

SECTION TOILET AND BATH ACCESSORIES ADDENDUM NO.4

SECTION PLASTIC TOILET COMPARTMENTS

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION DOMESTIC WATER PIPING SYSTEM

DESCRIPTION SAFETY: WARNINGS ORDERING INFORMATION T01-B INSTALLATION INSTRUCTIONS DROP-IN AND FREESTANDING BATH K-11343T / K-11344T

SECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier.

SPECIFICATIONS - DETAILED PROVISIONS SECTION EMERGENCY EYEWASH/SHOWER UNITS TABLE OF C O N T E N T S

Ceramic plumbing fixtures ASME A / CSA B

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

HOT, CHILLED, AND CONDENSING WATER PIPING SPECIALTIES (HVAC)

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

MODELS: 475 WM & 475 WMSS

September 6, 2016 Page 1 of 5

SECTION VIBRATION ISOLATION

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION COOLING TOWER

All proposals will be evaluated by a district committee. The following criteria/weighting will be used to evaluate each proposal:

for Crestview Homes, Inc. Plumbing Fixture Package B

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

Transcription:

University Contact: Energy & Engineering Group (302) 831-1744 SECTION 22 40 00_PLUMBING FIXTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Water closets. 2. Urinals. 3. Lavatories. 4. Sinks. 5. Service sinks. 6. Electric water coolers. 7. Showers. 8. Emergency showers. 9. Emergency Eye and Face Wash. 10. Emergency Combination Shower with Eye and Face Wash. B. The intent of these standards are to provide input to the design team on the University s preference of manufacturers, design, equipment options and quality assurance to maintain the longevity of its assets. 1.2 Related Sections: A. Section 22 05 00 Common Work for Plumbing Systems B. Section 22 05 01 Common Requirements for Plumbing Systems C. Section 22 11 00 Domestic Water Systems D. Section 22 13 00 Sanitary Sewer Systems E. Section 22 07 00 Plumbing Insulation. 1.3 Design Requirements A. Tank type water closets are not allowed on the University of Delaware Newark Campus. Consult with University Energy and Engineering group if wall mounted water closets cannot be used for the project. 22-40-00 PLUMBING FIXTURES Page 1

B. The use of plastic pipe supply tubes is not allowed. Use only chrome plated or braided stainless steel supply tubes. C. All plumbing fixtures shall be low consumption type. 1.4 SUBMITTALS A. Product Data: Submit catalog illustrations of fixtures, sizes, [rough-in dimensions, utility sizes, trim, and finishes. B. Manufacturer's Installation Instructions: Submit installation methods and procedures. 1.5 CLOSEOUT SUBMITTALS 1.6 MOCKUP A. Operation and Maintenance Data: Submit fixture, trim, exploded view and replacement parts lists. A. Construct mockup of typical bathroom group. B. Incorporate accepted mockup as part of Work. 1.7 DELIVERY, STORAGE, AND HANDLING A. Accept fixtures on site in factory packaging. Inspect for damage. B. Protect installed fixtures from damage by securing areas and by leaving factory packaging in place to protect fixtures and prevent use. 1.8 WARRANTY A. Furnish five year manufacturer parts only warranty for plumbing fixtures. 1.9 EXTRA MATERIALS A. Furnish two (2) faucet and flush valve rebuild kits per faucet and flush valve supplied. 22-40-00 PLUMBING FIXTURES Page 2

PART 2 PRODUCTS 2.1 FLUSH VALVE WATER CLOSETS 1. American Standard Plumbing 2. Kohler Co B. Bowl: ASME A112.19.2M; wall hung, siphon jet vitreous china closet bowl, with elongated rim, 1-1/2 inch top spud, china bolt caps. C. Wall Mounted Carrier: ASME A112.6.1; adjustable cast iron frame, integral drain hub and vent, adjustable spud, lugs for floor and wall attachment, threaded fixture studs with nuts and washers. 2.2 WALL HUNG URINALS 1. American Standard Plumbing 2. Kohler Co B. Urinal: ASME A112.19.2M; vitreous china, wall hung washout urinal with shields, integral trap, removable stainless steel strainer, top spud, steel supporting hanger. C. Wall Mounted Carrier: ASME A112.6.1; cast iron and steel frame with tubular legs, lugs for floor and wall attachment, threaded fixture studs for fixture hanger, bearing studs. 2.3 MANUAL FLUSH VALVES A. Manufacturers: 1. Moen Model Number 8310M16 2. Sloan Valve Co. Model Royal. 2.4 AUTOMATED FLUSH VALVES (FOR USE WITH URINALS ONLY) A. Manufacturers: 1. Moen Model Number 8315 2. Sloan Optima (hard wired AC powered types only) 2.5 LAVATORY FAUCETS 1. Chicago Faucets 2. Moen (M-Dura Commercial Products Only) 22-40-00 PLUMBING FIXTURES Page 3

3. T&S Brass B. For Residence Hall Projects only the following Lavatory Faucets: 1. Standard Bath Faucet: Moen Model 8216 or Speakman Model SC4072-LD 2. ADA Bath Faucet: Moen Model 8219 or Speakman Model SC4074-LD 2.6 FOOD SERVICE SINK FAUCETS 1. T & S Brass & Bronze Works Inc 2. Moen (M-Dura Commercial Products Only) B. Single lever mixing type food service sink faucets are not allowed at University of Delaware facilities. All food service sink faucets shall have dedicated handles for hot and cold water. 2.7 RESIDENCE HALL KITCHEN SINK FAUCETS 1. Moen model 8227 2.8 SHOWERS VALVES 1. Speakman SentinelPro SM5010 2. Speakman SentinelPro SM5080-ADA (For ADA Showers) 2.9 ELECTRIC WATER COOLERS 1. Elkay B. Fountain: 1. ARI 1010; recessed or handicapped mounted electric water cooler with stainless steel top, stainless steel body, elevated anti-squirt bubbler with stream guard, automatic stream regulator, push button, mounting bracket, refrigerated with integral air cooled condenser and stainless steel grille. 2.10 MOP SINKS 2. Fountain must be capable of supplying water at 50 degrees Fahrenheit. 1. Pro Flo 22-40-00 PLUMBING FIXTURES Page 4

B. Bowl: 36 x 24 x 10 inch high white molded stone, floor mounted, with one inch wide shoulders, vinyl bumper guard and stainless steel strainer. C. Trim: ASME A112.18.1 exposed wall type supply with lever handles, spout wall brace, vacuum breaker, hose end spout, strainers, eccentric adjustable inlets, integral screwdriver stops with covering caps and adjustable threaded wall flanges. D. Accessories: 1. 5 feet of 1/2 inch diameter plain end reinforced rubber hose. 2. Hose clamp hanger. 3. Mop hanger. 2.11 EMERGENCY SHOWER 1. Speakman Company B. Refer to safety equipment standard for further requirements 2.12 EMERGENCY EYE AND FACE WASH 1. Speakman Company B. Refer to safety equipment standard for further requirements 2.13 EMERGENCY COMBINATION SHOWER WITH EYE AND FACE WASH 1. Speakman Company B. Refer to safety equipment standard for further requirements 2.14 LAVATORY INSULATION KIT A. Product Description: Where Lavatories are noted to be insulated for ADA compliance, furnish the following: Safety Covers conforming to ANSI A177.1 and consisting of insulation kit of molded closed cell vinyl construction, 3/16 inch thick, for insulating tailpiece, P-trap, valves, and supply piping. Furnish with weep hole and angle valve access covers. 22-40-00 PLUMBING FIXTURES Page 5

PART 3 EXECUTION 3.1 EXAMINATION A. Verify walls and floor finishes are prepared and ready for installation of fixtures. B. Verify electric power is available and of correct characteristics. C. Confirm millwork is constructed with adequate provision for installation of counter top lavatories and sinks. 3.2 PREPARATION A. Rough-in fixture piping connections in accordance with minimum sizes indicated in fixture rough-in schedule for particular fixtures. 3.3 INSTALLATION A. Install each fixture with trap, easily removable for servicing and cleaning. B. Provide chrome plated rigid or flexible supplies to fixtures with loose key stops, reducers, and chrome escutcheons. C. Install components level and plumb. D. Install and secure fixtures in place with wall carriers and bolts. E. Seal fixtures to wall and floor surfaces with sealant F. For ADA accessible water closets, install flush valve with handle to wide side of stall. 3.4 INTERFACE WITH OTHER PRODUCTS A. Review millwork shop-drawings. Confirm location and size of fixtures and openings before rough in and installation. 3.5 ADJUSTING A. Adjust stops or valves for intended water flow rate to fixtures without splashing, noise, or overflow. 3.6 CLEANING A. Clean plumbing fixtures and equipment. 22-40-00 PLUMBING FIXTURES Page 6

3.7 PROTECTION OF INSTALLED CONSTRUCTION A. Do not permit use of fixtures before final acceptance. END OF SECTION 22-40-00 PLUMBING FIXTURES Page 7