HVAC Real-time Remote Monitoring 4 year Case Study Delivering Value

Similar documents
Introduction to Building Analytics

Niagara Case Studies. Chirayu Shah General Manger Conserve It

Ground Source Heat Pump System Performance: Measuring the COP

Ener.co & Viridian Energy & Env. Using Data Loggers to Improve Chilled Water Plant Efficiency. Randy Mead, C.E.M, CMVP

D DAVID PUBLISHING. Optimizing Thermal Energy Storage Systems in the Hospitality Industry. 1. Introduction

Field Test of Cold Climate Air Source Heat Pumps

Hospitality. Comprehensive asset management & revenue enhancement capabilities

For the Medical Device Industry

GE APM Reliability Management for Wind

Vivint Smart Home. Energy Savings Study. Heating and Cooling Results. September 2017

GxTracker TM INSTALLATION AND USERS MANUAL. The Geoexchange Tracker

Improving the efficiency, occupant comfort, and financial well-being of campus buildings

Project Information. Measure Description

Precision Automatic Vacuum Control (PAVC+)

WHITE PAPER. Analytics Software. Find what Matters

Demand Response on a. Randy Palombi General Manager CPower, Inc.

BuildingEngines. Operations Performance Management (OPM) Don t Just Work... Perform. Success Kit. Operations Performance Management

Optimizing Buildings Using Analytics and Engineering Expertise

Field Test of Cold Climate Air Source Heat Pumps

Commercial HVAC Advanced Diagnostics Programs. ACEEE Market Symposium March 20, 2006

Small Oil-Less Centrifugal Compressors: Bringing Energy Efficiency and Reduced Costs to Chiller Plants

START-UP CHECKLIST. Date: Job Name: Customer Name: Address: City: State: Zip: Model Number: Serial Number: Qualified Start-up Technician:

Eliminating Blind Spots in Commercial Trucking with IoT

Summary of 60-Day Notice: Smart Thermostat Demand Response

Energy Efficiency Programs SaveGas Hot Water Control with Continuous Commissioning Program Implementation Plan

Building Operator Certification Level I

Your Trusted Partner in Customer Engagement

TruTech Technical Training

Compress Your Air Costs.

Sample Chapter. Producing Meaningful Metrics

Persistence Tracking in a Retro-commissioning Program

CityTouch connect application. Public lighting. Stay in touch with your street lights

Geothermal Alliance of Illinois Sales and Marketing for Technicians

Implications of Measured Commercial Building Loads on Geothermal System Sizing

Every building needs an Energy Efficiency Platform.

05/14/2012 THE CRIME OF IMPROPER ENERGY MANAGEMENT AGENDA

Video Assurance Best Practices For Minerva Platform Operators

Existing Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne

LADWP Customer Bill of Rights. January 3, Pending approval by Board of Water and Power Commissioners.

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings

NATIONAL ACCOUNTS RETAIL GROCERY RESTAURANT HOSPITALITY INDUSTRIAL

WATERVISION INTEGRATED REMOTE IRRIGATION MANAGEMENT

Service Goes Digital! A toolbox for acquiring digital capabilities for your service business

Razvan IONITA 27 Oct 2016 UNIFORMANCE SUITE. Delivers New Process Intelligence Capabilities

Overview NU Conservation Programs & Other Interesting Opportunities: Industrial process sub-metering. Dave McIntosh Justin Marmaras

Vectren Indiana 2016 Residential Rebate Application

Facility Manager s Guide to Submetering for Energy Efficiency, Cost Reduction and Predictive Maintenance

Matt Gudorf Campus Energy Manager. Page 1

Fact Sheet. Commissioning WHAT IS THE PURPOSE OF THIS REQUIREMENT? WHAT VALUE DOES IT PROVIDE TO THE OWNER? HOW DOES IT SAVE ENERGY?

Instant discount of 33% off improvement cost, up to $1,250 Plus, potential savings bonus of up to $250 (**)

BOC Training Equivalency Crosswalk

Geothermal System Design Overview Course 1

Performance and Applications of Cold- Climate Air Source Heat Pumps

Cloud-Based Integrated Demand Side Management

Go Green, Get Geo! GEOTHERMAL SYSTEMS GEOEXCEL: ULTIMATE PERFORMANCE AND RELIABILITY GEO-411. Geothermal Loop Types

An Introduction to The Retro-Commissioning Process For Existing Buildings

Intelligent Energy Management for Multi-Unit Operations:

FirstEnergy s Pennsylvania Utilities. Energy Efficiency Programs for Business

Working Together to Manage Your Company s Energy Use.

Smart Residential Thermostats Results from the FlashTAG on December 20, 2012

REDEFINE YOUR BIOMEDICAL, FACILITIES, & HEALTHCARE TECHNOLOGY MANAGEMENT STRATEGIES

HEAT PUMP POOL HEATERS CERTIFICATION PROGRAM

Building Retro-Commissioning

PROJECT CONTROL IT ASSET AUDIT AND DOCUMENTATION

Case Study for Fortune 500 Telecom: Retrofitting Pneumatic Controls for Energy Efficiency

Nectar Converged Management Platform

Honeywell Software Service Tools Help Manage Control System Performance, Security and Process Plant Outcomes

Resco Cloud Quick Guide for Field Service Technicians. Offline Customizable Mobile & Desktop Solution

The Optanix Platform. Service Predictability. Delivered. Optanix Platform Overview. Overview. 95% 91% proactive incidents first-time fix rate

How Process Window Index is Determined

Section 2: Estimating Energy Savings and Incentives

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

IBM Tivoli Service Desk

THE SMART READINESS INDICATOR FOR BUILDINGS

Optimizing Energy Use in a HealthCare Setting. Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning

Trane Water-Source Variable Refrigerant Flow

Optanix Platform The Technical Value: How it Works POSITION PAPER

Opportunities for Advanced Services

AMI and the Customer: Priorities for Pepco Holdings Smart Metering Program

USERS CONFERENCE Copyright 2016 OSIsoft, LLC

Leveraging Smart Meter Data & Expanding Services BY ELLEN FRANCONI, PH.D., BEMP, MEMBER ASHRAE; DAVID JUMP, PH.D., P.E.

SMART HVAC & LIGHTING SYSTEMS. Savings From Two Major C&I End Uses

Oil & Gas Industry. Smart Remote Automation. An Extension of PlantWeb Digital Architecture. PlantWeb

Enterprise Asset Management STREAMLINE FACILITY MAINTENANCE OPERATIONS & REDUCE COSTS

Be Proactive With Ops Analytics - Leverage your Splunk Investment. October 8, 2015 Copyright 2015 Vivit Worldwide Copyright 2015 Vivit Worldwide

Normal Children's Discovery Museum, LEED Silver:

Where to find the right data sources?

VideojetConnect TM Remote Service. For select Ethernet-enabled Videojet printers

Strategies for Persistence: Measurement and Verification. Ryan Hughes PE, CEM, LEED AP Eaton Energy Solutions

Appendix D Example M&V Plans

APM & Field Service Integration

Variable Frequency Drive Retrofit Opportunities. Michael Kuk CERx Solutions LLC

THE ENERGY ENGINEERING COMPANY. E²CON-GE ENGINE CONTROLLER Retrofit system based on openecs for modernizing GE Jenbacher gas engines.

Installation address City State ZIP. Complete all fields for each piece of equipment purchased and installed. Natural Gas Furnace Information

2/17/2017. Energy Accounting & Education. Topics (Electricity) Creating Electricity

ALM Tools. Obtaining ROI from an ALM Tool. SmartBear White Papers

TrueSense* for Cooling

DIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT

Greg Stallings RE: Meeting at Knoxville Trane Office Trane Commercial Systems 202 King Drive Greg Stallings, Dr Keith Willis, Eric Simon,

Transcription:

Denis Collet, President - Engineer CLD industries, LLC dcollet@cld-industries.com Cell Number 845-399-8540 HVAC Real-time Remote Monitoring 4 year Case Study Delivering Value Denis Collet, CLD Industries LLC Breakout Session Category Technical

Session Objectives NYSERDA Residential Geothermal Monitoring Case Study Background (The why) Understanding the key metrics for monitoring and measuring system performance Interpreting the data New skills required for analyzing and diagnosing systems Recognizing value of remote monitoring to the Customer, Service contractor and HP Manufacturer Critical to removing negative perceptions Improving adoption of technology Remote monitoring - tool for delivery value added services lower cost and higher value services Doing more, doing it better, doing it cheaper 2

The Study NY State Energy & Research Development Authority Supported Project Deploy Real Time Telemetry to Validate Geothermal Technology Claims Investigate reliability issues? Cost effectiveness? Address the need for collecting statistical data to support the claimed benefits of adopting technology Generate data to support the continuation of state and federal incentives for residential Geothermal Quantify the ROI 3

Agenda Building Automation vs Residential remote monitoring (What s different?) Remote Data Who needs it? What metrics are critical? Interpreting and analyzing the data Case studies Expert s Perspective Conclusion 4

Contrasting Commercial Building Automation with Residential Monitoring Commercial Building Automation and Control (BAC) has been maturing for over 40 years Inhibitors to penetration into residential and small commercial market - Custom development - System software is proprietary - Recovery costs for software built into pricing Residential Monitoring Is rapidly inserting itself into service industry - Combines custom and Open Source Software - High speed internet access is ubiquitous - Lower cost components 5

Remote Data Who Needs It? The Subscribers Home owner - Verification of operation (Current settings, system status, etc.) - Review energy consumption on demand - Distinguish system operational costs from other electricity usage* - Provides critical information empowering customer to make intelligent decisions related to system repair or replacement Service provider - Captures information to assure Customer that service provider is acting in Customers best interest* - Alerts : Provide visual, text, or email of potential system problem - Comparative analysis of system performance against baseline - Real-time and historical data for assessing performance - Problem Diagnosis Root Cause Analysis Collaboration with Subject Matter Experts, MFG Engineering Manufacturer - Provides real time field data to identify engineering, manufacturing, or installation defects and related problems 6

What metrics are critical? Key Performance Indicators Temperature Ground loop Entering Water Temp (EWT), Leaving Water Temp (LWT) Air In, Air Out Load side W2W EWT, LWT Outside Air Optional temperature sensing Suction and Discharge System State (Digital I/O) Demand heating/cooling System state (1 st, 2 nd, 3 rd, E heat, cooling / heating) Flow rate - Ground Loop Pressure - Ground Loop Electrical Usage - Heat Pump, and dependent auxiliary systems Kilowatt, Voltage, Amperage, Kilowatt Hours (Aggregate) 7

Interpreting and Analyzing Information Direct visualization of performance without complex calculations Temperature differential (Delta t) of EWT and LWT Delta T Load side Air in and Air Out or Load side EWT and LWT Water Flow and Pressure KPIs monitored as outlined in Critical Metrics above facilitate real time calculations for measuring System Efficiency at a glance Heat of Extraction/Rejection (EWT - LWT) x GPM x 60 x 8.35 = Absorbed BTUH Kw (True Power) x 3.412 (BTUH per watt) = Electricity BTUH (unit's HP electric usage) Coefficient of Performance (COP) (Absorbed BTUH + Electricity BTUH) Electricity BTUH = COP Graphs providing comparative costs for alternative Modalities of heating 8

Visualizing System Performance Web Portal Tool Chest

System Stages Daily/hourly (Jan 1 Jan 31) 2015 Daily Jan 8, 2015 Hourly 10

Performance Graph Jan 8, 2015 (12 Hour view Jan 8, 2015 (4 Hour view) 1111

Status Dashboard Snapshot Jan 8, 2015 4:00:04 PM Snap shot with additional information not provided on Performance timeline Thermostat - Room Temp (LCD Temp) - Heat Set-point - Cool Set-point Thermostat Mode (state) System (state) Electrical - Voltage - Current (Amps) - Instant (KW) - Aggregate (KWH) System information description 12

Problem Determination and Remediation Current Process Preliminary assessment. - Customer complaining not heating enough Send field engineer with appropriate skills to investigate Field site visit : Set up instrumentation and perform visual inspection to verify ü Flow rate (Pressure differential on heat exchanger) ü Temperature - Air In, Air out, Ground loop WI, WO (ground loop), etc. ü Thermostat Status ( Mode*, Set point, room temp) ü System Status (1 st, 2 nd, 3 rd heating etc..) Advise client based on assessment Either replace component at time of visit or schedule return for follow-up repair Verify Repair was successful ** Alternative Workflows Remote Monitoring Review system critical performance indicators leading up to the event ü ü ü ü ü ü Review Alerts if any Examine Timeline graph for period when event occurred Launch detailed status dashboard (select instance in time just before event) Step forward on status dashboard Review metrics monitored as they change to determine what has failed or may be responsible for interruption in service Review system history with subject matter expert/system engineer* if necessary take further action based on evaluation of real time and historical data Resume system monitoring after system restored 13

Case Studies Demonstrating Value in the Wild

First Case Study Hard Failure No Heat

System - Failure Customer Complaint - No Heat - Home Owner wakes up to discover room temperature at 60 F Calls for service - Service tech logs onto web portal Checks last 24 hours system performance graph Observes anomaly at about 3:30 AM ü Dramatic drop in Air Out temperature and increase in Water Out temperature (No heat exchange) ü Flow rate, pressure and current system state seem normal. ü System goes into second stage heat after time delay. Needs additional detail of events leading up to failure - Checks system status dashboard 16

Status Just Prior to Failure ü EWT and LWT ü Air in and Air out ü Thermostat ü Flow rate ü System state ü Electrical Energy All parameters prior to failure appear within acceptable tolerances * 17

Status Just After Failure - Technician goes to status view from Time-Line graph. During review of parameters observes: - Dramatic drop in Air Out temp and rise in temp of LWT - Flow rate, pressure and current state seem normal. - Power consumption indicates compressor off line - Thermostat status indicates calling for heat stage 1 - System status indicates stage 1 heating enabled* 18

Problem determination Analysis of time line and failure was indicative of unexpected Compressor lock out Review of the captured monitoring system data leading up to the fault incident + Experienced Service Tech, indicates bad system sensor Service technician brings a replacement to site Verifies sensor is defective using approved method Replaces defective sensor Follow up with monitoring that system is restored 19

Case Study 2 Normal monitoring of System Reveals System in Emergency Heat mode?

System in Emergency Heat Mode Routine monitoring revealed system inadvertently set to E Heat instead of Heat - Anomaly noticed during routine scan (E Heat mode sometime during day Oct 21, 2014) - Hourly detail shows that first occurred at around 8:00 PM 21

System in Emergency Heat Mode Performance Chart No fault indication prior to switching to E Heat mode 22

System in Emergency Heat Mode Status View Routine monitoring revealed system inadvertently set to E Heat (Aux Heat) instead of Heat 23

Case Study 3 Expert s Perspective Lloyd Hamilton Verdae LLC Intermittent System Lockout Low Pressure/Temperature

System Intermittent Failure Customer Complaint Manual Resetting - Service tech was uncertain what was going on Intermittent lock out of compressor Several months and many trips attempting to diagnose problem. The System under observation is a Water Furnace Synergy 3-D 5 zone heating and cooling heat pump that is a 5 zone water-to-air and water-towater Heat Pump The following snap shot illustrates performance of the system over a twohour period. 25

System Intermittent Failure Analyzing the data It was clear that temperature of the air out was dangerously close to freezing Flow 15 GPM Water Out = 63 F Water In = 58 F Air In = 67 F Air Out = 34.8 F Water Delta t 5 Air Delta t 32.2 F 26

Navigating Complex System Behavior Some systems exhibit behaviors Impossible to analyze without viewing history Cooling Fan Only Heating Flow Rate 15 GPM Electrical 5.14 Kw 22.20 A 27

Case Study 4 Identifying Areas for System Design / Improvement

System Short Cycling - Historical Data provides knowledge that drives design optimization Historical trending indicates sub-optimal positioning of thermostat with respect to air supply register 05:31-05:40 Heat Cycle 06:01-06:12 Air Only 05:05 08:09 29

Beyond Geothermal New Projects

Complementing Zero Net Energy Initiatives Zero Energy housing development I take great comfort in knowing that my geothermal system is precisely monitored from end to end I also know that I can take advantage of its energy consumption numbers to better understand how my zeroenergy home is performing across the board, by comparing my total home consumption against the HVAC consumption numbers. David Shepler Homeowner (Green Acres) 31

Real-time Monitoring Installer Benefits Reduce Costs / Increase Profitability Fix it first time Fix it Quick Minimize unnecessary site visits Increase efficiency of Service Engineer Increase customer satisfaction (Customer Retention / Referral) Commissioning Systems quicker (Increase Profits) 32

Real-time Monitoring Customer Benefits Reduced mean-time to restore service 24 x 7 365 days a year monitoring and alerting Lower Service Costs Avoid false service calls Reduced inconvenience to customer Increased confidence in service company Directly view and assess their system performance 33

Conclusion Implications of remote monitoring residential systems on the future of the Service Industry - First tool to reach for in the tool chest! - Service providers offering 24 x 7 remote monitoring will be able to contain costs by - Fewer Site Visits - Reducing time to respond and restore service - Removing the guesswork - Eliminating call backs The value of the Visualization of data cannot be overstated Remote Monitoring is to Geothermal as OBD is to Auto Industry 34

Do we really want to go back to a blinking fault light indicator for first level diagnosing a system fault?? 35

Questions? Denis Collet dcollet@cld-industries.com 36