Detail Drawings from Rev. 4/2017 126 Old Highway 60 East Hardinsburg, Kentucky 40143 Office: 270-788-3535 www.bestpanelcompany.com
Dri-Plane screen / similar / Similar Non-Corrosive Fastener designed to meet substrate criteria. Type S or Type N Mortar 1/2 to 1 maximum Thin Masonry Veneer Util-A-Crete Concrete Backer Board 3/8 Adhesive (for use with Brick or Decorative Block) applied in Dabs (or) Structural Silicone (for use with Natural or Manufactured Stone) applied in Vertical Strips. Substrate TYPICAL WALL DETAIL
Interior Finish Wood Framing Barrier Around Corner 16 Min. Insulation Exterior Sheathing & Water Resistant Barrier Rain Guard 7/16 thick HD concrete Board (by BEST Panel Company THIN Brick by Evolution Brick Thin Brick or Similar) UTIL-A-CRETE PANEL SYSTEM FULL WALL & CORNER DETAIL:
Interior Finish Wood Framing Barrier Around Corner 16 Min. Insulation Exterior Sheathing Dri-Plane Rain Screen If Specified Barrier 5 1/2 Panel Offset Dimension *Varies by thickness of brick Thin Brick 7/16 Concrete Board (by BEST Panel Company THIN Brick by Evolution Brick or Similar) UTIL-A-CRETE PANEL SYSTEM CORNER DETAIL
Interior Finish Wood Framing Barrier Around Corner 16 Min. Insulation Exterior Sheathing Barrier Polystyrene Thickness will vary between 1 and 6 depending on R-Value. If drainage plane is required it will be etched in the back of the polystyrene. 3/8 Concrete Board (by BEST Panel Company THIN Brick by Evolution Brick or Similar) Thin Brick 3CI INSULATED PANEL CORNER DETAIL: SCALE: FULL / LAST REVISION: 2/4/16
Interior Finish Wood Framing Insulation Barrier Around Corner 16 Min. Exterior Sheathing Barrier Polystyrene Thickness will vary between 1 and 6 depending on R-Value. If drainage plane is required it will be etched in the back of the polystyrene. Thin Brick 3/8 Concrete Board (by BEST Panel Company THIN Brick by Evolution Brick or Similar) 3CI INSULATED PANEL FULL WALL AND CORNER DETAIL
WOOD STUD OSB SHEATHING 2 LAYERS- WEATHER RESISTANT BARRIER RIGID INSULATION Dri-Plane 65 FT X 4 FT ROLL, 1/4 INCH THICK UTIL-A-CRETE PANEL SYSTEM WOOD STUD WITH DRI-PLANE DETAIL
THERMASTEEL COMPOSITE STRUCTURAL INSULATED PANELS WATER VAPOR BARRIER Dri-Plane 65 FT X 4 FT ROLL, 1/4 INCH THICK UTIL-A-CRETE PANEL SYSTEM THERMASTEEL WITH DRI-PLANE DETAIL
1/8 per 10 of wall min. Soffit Galv. Flashing Non-Corrosive Soffit Fastener Dri-Plane rain screen / similar 3/8 Substrate Util-A-Crete 7/16 Concrete Backer Board Non-Corrosive Fastener designed to meet substrate criteria. TYPICAL SOFFIT DETAIL
Dri-Plane rain screen / similar Flashing Tape Wrapped Over Rigid Flashing Type S or Type N Mortar Util-A-Crete 7/16 Concrete Backer Board 26 Gauge Flashing Fastened & Adhered to Building Structure X to be determined by system thickness 3/4 2 1/2 x Control Joint Opening to be Determined by Architect or Engineer. Substrate 3/8 Non-Corrosive Fastener designed to meet substrate criteria. 1/2 to 1 maximum Thin Brick Veneer HORIZONTAL CONTROL JOINT
Dri-Plane rain screen / similar Util-A-Crete 1/2 Concrete Backer Board Non-Corrosive Fastener designed to meet substrate criteria. Structure Above FNDN Top of FNDN 3/4 2 1/2 x 26 Gauge Flashing Fastened & Adhered to Building Structure Masonry Foundation 1 1/2 min. 2 1/2 min. Masonry FNDN as required by code Flashing Tape Finished Grade Sidewalk as Occurs Flexible Sealant BASE DETAIL ABOVE GRADE
Dri-Plane rain screen / similar 1/2 to 1 maximum Thin Masonry Veneer Util-A-Crete 1/2 Concrete Backer Board Sealant w/ Backer Rod Flashing Tape Substrate Non-Corrosive Fastener designed to meet substrate criteria. Jamb Blocking Disclaimer of Liability - This detail is meant to show the installation of the Best Panel System only. Always check first with the window manufacturer for their recommendation on how to flash & install their windows. RECESSED WINDOW JAMB
0.090 " 4.000 " TFC.345".355" THREAD BLANK DIAMETER 2.750 ".132".136" #2 Square Recess 0.235 " 0.050 " #14-13 BUTTRESS THREAD FORM Major Dia.:.230" /.235" Minor Dia.:.148" /.134".250" PILOT PERFORMANCE REQUIRMENTS CONCENTRICITY: Drive to Shank =.013" TIR max DRILL/DRIVE: 16ga (.075") - 35lb load - 2,000RPM 3.5 seconds max (25 pcs sampling) TORSIONAL SHRENGTH: 90 inch pounds min. VIRTUAL DESIGN #14-13 x 4" DP2 SMALL HEAD ACTUAL SIZE 4.000 " NOTES 1. Fasteners to meet SAE J-78 specifications for self-drilling fasteners. 2. All dimensions are nominal expect when noted. Normal heading tolerances permitted. 3. Two (2) #2 square drive power bits included in each KWIK-PAK bucket. Must be two-piece power bits. REDUCED SQUARE POWER BITS.350" REV Design information provided on this drawing is the property of Triangle Fastener Corporation, Pittsburgh, PA. Any use without written permission is prohibited. DRAWING NUMBER DESCRIPTION PART WEIGHT PART NUMBER TFC FASTENING SYSTEMS DESIGN CENTER 4661 HINCKLEY INDUSTRIAL PARKWAY CLEVELAND, OH 44109 PHONE: (216) 351-9933 FAX: (216) 351-5008 www.trianglefastener.com MATERIAL FINISH and CORROSION TEST REQUIREMENT HEAT TREATMENT CASE HARDEN (SAE J78) CUSTOMER PACKAGING Pack in 2-gal KWIK-PAK plastic buckets. CUSTOMER APPROVAL REVISIONS 3CI - SCREW REQUIREMENT