Title. Author(s)Yoshizawa, Keisuke; Noguchi, So; Igarashi, Hajime. CitationIEEE Transactions on Applied Superconductivity, 21(3. Issue Date

Similar documents
An optimizing design method for a compact iron shielded superconducting magnet of MRI *

A Superconducting Magnet System for Whole-Body Metabolism Imaging

Progress In Electromagnetics Research M, Vol. 28, 1 13, 2013

Recent Development of Soft Magnetic Materials. K. I. ARAI õ and K. ISHIYAMA õ ABSTRACT

Study with Magnetic Property Measurement of Amorphous HB1 Material and its Application in Distribution Transformer

B H. Magnetic materials

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, VOL. 28, NO. 3, APRIL

grain-oriented electric steel works must be obtained from the IEE

Graphite structure and magnetic parameters of flake graphite cast iron

Publication P Institute of Electrical and Electronics Engineers (IEEE)

Study on magnetic separation device for scale removal from feed-water in thermal power plant

Title. Author(s)K. HAMAMURA; K. ONO; M. MATSUMURA; T. TARUI; S. KODA. Issue Date Doc URL. Type. Note. File Information

Low Curie temperature material for induction heating self-temperature controlling system

High Silicon Steel Sheets Realizing Excellent High Frequency Reactor Performance

Effect on deformation process of adding a copper core to multifilament MgB2 superconducting wire

Title. Author(s)MOHAMMED, AHMED MOHAMMED YOUSSEF; AHMED, ALI; MAEKAW. Issue Date Doc URL. Type. Note. File Information CROSS-SECTIONS

INVESTIGATION OF IMPACT OF MAGNETIC SHUNT PARAMETERS ON TEMPERATURE DISTRIBUTION IN TRANFORMER TANKS

Parametric analysis of magnetic field mitigation shielding for underground power cables

Influence of nickel addition on magnetic and electro-mechanical behaviour of permalloys

Soft Magnetic Properties of Nanocystalline Fe Si B Nb Cu Rod Alloys Obtained by Crystallization of Cast Amorphous Phase

Title. Author(s)BAI, DI; HAYASHIKAWA, T.; MATSUMOTO, TAKASHI; HE, XI. Issue Date Doc URL. Type. Note. File Information

Formation and Soft Magnetic Properties of Co Fe Si B Nb Bulk Glassy Alloys

Embedded Planar Power Inductor in an Organic Interposer for Package-Level DC Power Grid

Development of an Axial Gap motor with Amorphous Metal Cores

Influence of Stress-Relief Annealing on Magnetic Properties of Motor Cores Using Induced Current Heating Method

Effect of the Annealing Temperature on Magnetic property for Transformer with Amorphous Core

Title. CitationElectronics Goes Green (EGG 2004) September 6- Issue Date Doc URL

Effect of aromatic hydrocarbon addition on in situ powder-in-tube processed MgB 2

March 6-9, 2016 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive- Session 6

7. FERROMAGNETIC MATERIALS. aligned atomic dipoles

Title. Author(s)M. KAWATANI; S. MATSUMOTO; X. HE; Y. HASHIMOTO. Issue Date Doc URL. Type. Note. File Information TRAIN LOAD

Title. Author(s)CHEN, Z. W.; XU, Y. L. Issue Date Doc URL. Type. Note. File Information LOADING.

TEMPERATURE FIELD SIMULATION RESEARCH ON THE LEAKAGE INDUCTANCE TRANSFORMER

Electromagnetic Finite Element Analysis of Electrical Steels Combinations in Lamination Core Steps of Single-Phase Distribution Transformers

RESULTS FROM THE NEW SLAC PERMEAMETER. J. K. Cobb and R. A. Early Stanford Linear Accelerator Center, Stanford University, Stanford, CA ABSTRACT

A comparison of chosen permanent magnets arrangements for high gradient magnetic fields generation

Title. Author(s)ARDESHIR DEYLAMI; MOSTAFA FEGHHI. Issue Date Doc URL. Type. Note. File Information IRREGULARITY IN HEIGHT

Applications using Open-Type Magnetic Shielding Method

Hard magnetic property and δm(h) plot for sintered NdFeB magnet

Increase of Tape Wound Core Losses Due to Interlamination Short Circuits and Orthogonal Flux Components

International Symposium Non-Destructive Testing in Civil Engineering (NDT-CE) September 15-17, 2015, Berlin, Germany

Superconducting. magnets. The heart of NMR

Title. Author(s)IYODA, T.; HARASAWA, Y.; HOSOKAWA, Y. Issue Date Doc URL. Type. Note. File Information

Phase error in current transformers with nanocrystalline alloys core

Guidelines for usages of Amorphous Core or CRGO Core Distribution Transformers CENTRAL ELECTRICITY AUTHORITY


This is a preview - click here to buy the full publication TECHNICAL REPORT. Pulsed field magnetometry

TDK s Environmental Technologies

Effect of CO Gas Concentration on Reduction Rate of Major Mineral Phase in Sintered Iron Ore

A new magnetic NDE method in inconel 600 alloy

Dust Core with Low Core-loss for High-frequency Applications

Development of Nb 3 Sn in Japan

MAGNETIC EVALUATION OF THE EMBRITLLEMENT ON COLD-ROLLED STEELS

March 6-9, 2016 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive- Session 6

This is a repository copy of Analytical magnetic field analysis of Halhach magnetized permanent-magnet machines.

Systematic Design and Implementation of Large-Capacity Power Transformer

INTRODUCTION TO MAGNETIC MATERIALS

Corrosion Effects on the Magnetic Behavior of Magnetic Circuit of an Induction Machine

Connecting Coolers to Superconducting Magnets with a Thermal-Siphon Cooling Loop

Temperature stable design of Microwave Circulators using HFSS and Maxwell. Dr. Thomas Lingel

Glossary of Magnetic Terms

Author(s) Issue Date Right.

ELASTO-MAGNETIC SENSOR UTILIZATION ON STEEL CABLE STRESS MEASUREMENT

Detection of Sensitization for 600 Alloy and Austenitic Stainless Steel by Magnetic Field Sensor

MAGNETIC PROPERTIES OF SOME PERMINVAR FERRITES

Experimental Verification of the Linear Relationship Between Stress and the Reciprocal of the Peak Barkhausen Voltage in ASTM A36 Steel

Title. Author(s)KIM, K.; LEE, K. S.; KANG, Y. J. Issue Date Doc URL. Type. Note. File Information CONSTRUCTION

Title. Issue Date Doc URL. Type. Note. File Information UNDER CONTROLLED SHEAR AND AXIAL FORCES.

MEDICAL magnetic resonance (MR) imaging during interventional

Guidelines for usage of Amorphous Core or CRGO Core Distribution Transformers

Section Pot Cores Low Level Applications

Applied MHD at the University of Bologna

C Si Mn Cr Mo Cu Ni P S

Development of a Novel Yokeless and Segmented Armature Axial Flux Machine Based On Soft Magnetic Powder Composites (WP ) I.

Capabilities of MFL Inspection in DUPLEX Steel Pipelines

Electronic materials and components-inductive components

Synthetic antiferromagnet with Heusler alloy Co 2 FeAl ferromagnetic layers

Introduction of Magnetic Material Products

Thickness Detection of Corroded Steel Plate by Low-Frequency Eddy Current Testing

Title. Author(s)M. OHSAKI; S. TSUDA; N. SUGIYAMA. Issue Date Doc URL. Type. Note. File Information DIRECTIONAL SEISMIC VIBRATION CONTROL

2015 IEEE. REPRINTED, WITH PERMISSION, FROM Next Generation Metallization Technique for IC Package Application

What is Cryogenics? Cryogenics is the science and technology associated with generation of low temperature below 123 K.

The Why & How of Magnets The sources of nearly all magnetic effects in matter are the electrons in atoms.

Loughborough University Institutional Repository. This item was submitted to Loughborough University's Institutional Repository by the/an author.

This full text version, available on TeesRep, is the post print (final version prior to publication) of:

Induction Heating. Jean Callebaut, Laborelec. 1 Introduction Physical principles Induction Installations... 5

Carbon Doping of MgB 2 by Toluene and Malic-Acid-in-Toluene

Creative Commons: Attribution 3.0 Hong Kong License

Frequency behaviour of SPD treated soft magnetic materials

Quench Protection of Very Large, 50 GJ Class and High-temperature Superconductor Based Detector Magnets

Available online at ScienceDirect. 20th European Conference on Fracture (ECF20)

HOEGANAES INSULATED POWDER COMPOSITES CHARACTERISTICS AND ELECTROMAGNETIC APPLICATION GUIDELINES

Effects of Water Content on Dielectric Properties of Mineral Transformer Oil

Modelling the power losses in the ferromagnetic materials

SEEDING ELEMENT POLARITY ARRANGEMENT ON DRUM-TYPE MAGNETIC PRECISION SEEDER

Title. Author(s)Aoyama, Yusuke; Suzuki, Kengo; Tabe, Yutaka; Chikahi. CitationElectrochemistry Communications, 41: Issue Date

NMR INSPECTION ON CONCRETE-COATINGS

Computation and analysis of temperature distribution in the crosssection

Inducement of superconductivity in Fe(Te,S) by sulfuric acid treatment

Feasibility Study of Measuring the Stress in Prestressing Tendons Using Induced Magnetic Field

Transcription:

Title Influence of Magnetic Property of Ferromagnetic Shie Author(s)Yoshizawa, Keisuke; Noguchi, So; Igarashi, Hajime CitationIEEE Transactions on Applied Superconductivity, 1(3 Issue Date 011-06 Doc URL http://hdl.handle.net/115/46836 Rights 010 IEEE. Reprinted, with permission, from Keisuk Magnetic Property of Ferromagnetic Shield on High Fi SUPERCONDUCTIVITY, June 011. This material is poste IEEE does not in any way imply IEEE endorsement of a personal use of this material is permitted. However, promotional purposes or for creating new collective by writing to pubs-permissions@ieee.org. By choosing copyright laws protecting it. Type article (author version) File Information TAS1-3_088-091.pdf Instructions for use Hokkaido University Collection of Scholarly and Aca

Influence of Magnetic Property of Ferromagnetic Shield on High Field Magnet Analysis Keisuke Yoshizawa, So Noguchi, and Hajime Igarashi Abstract In this paper, an influence of a magnetic property of a ferromagnetic shield on design of a high field magnet, which generates high magnetic field with high homogeneity, such as NMR and MRI, is described. The NMR and MRI magnets often need the magnetic shield to protect an environment and to reduce a stray magnetic field. An iron shield used as a general magnetic shield typically has a nonlinear magnetic property. In magnetic analysis for the magnet design, we have to take into account the nonlinearity of the magnetic property of iron to compute the accurate magnetic field, since the ferromagnetic shield is exposed to so high magnetic field. That is, the iron is saturated in high magnetic field. So far the design of the high field magnets with the ferromagnetic shield exposed to over T has been less reported. Recently, it was reported that the nonlinear magnetic properties of iron were measured at high magnetic fields over T. The difference among the magnetic fields of the high field magnets with the ferromagnetic shield, computed by the finite element method with a few magnetization curves, is investigated. Index Terms High-temperature superconductors, magnetic field analysis, magnetic shielding, NMR, MRI. I. INTRODUCTION superconducting magnet system, such as NMR and MRI, Ais required to generate a high magnetic field with high homogeneity. At design stage of the NMR magnet configuration, magnetic field analysis is required. In the NMR magnet system, a magnetic shielding (e.g. iron shield, active shield and room shielding) is often installed to avoid exposing the environment to the strong stray field. Especially, the iron shield is commonly employed as a typical magnetic shielding. Therefore, the nonlinearity of the magnetic property of the iron shield has to be taken into account on the analysis of the NMR magnet design. Recent years, the higher magnetic fields can be realized by the superconducting magnets wound with high temperature superconducting (HTS) tapes [1] [5]. The iron shield installed to these magnet systems is exposed to the higher magnetic field. Therefore, on the analysis of the NMR magnet systems, we have to take into account the nonlinear magnetization curve (B-H curves) in the range of the significantly high magnetic field over the saturation magnetic field (over T). The relative magnetic permeability of the iron is expected to Manuscript received 3 August 010. K. Yoshizawa, S. Noguchi, and H. Igarashi are with the Graduate School of Information Science and Technology, Hokkaido University, Kita 14 Nishi 9, Kita-ku, Sapporo 060-0814, Japan. (corresponding author to provide phone: +81-11-706-7671; fax: +81-11-706-7670; e-mail: noguchi@ssi.ist.hokudai.ac.jp). be 1.0 over the magnetic field where the ferromagnetic materials are completely saturated. However, the experimental nonlinear magnetization curve of the ferromagnetic materials in such high magnetic field has not been reported until recent years. On the common magnetic field analysis, the magnetization curves in the range of the significantly high magnetic field (over T) are extrapolated from the measured data at the low magnetic fields (below T). However, the extrapolated relative magnetic permeability doesn t become 1.0 in the range of the significantly high magnetic field. Therefore, the computed results with the extrapolated magnetization curves may cause a difference from the result with the accurate magnetization curve. In this study, the magnetic field generated by the NMR magnet with the magnetic shielding is investigated using a few magnetization curves. The magnet configurations designed in [6] and [7] to generate the highly homogeneous and high magnetic field are employed. To these magnet configurations, the magnetization curves to be compared are the curve based on the experimental data over T [8], the extrapolated curve used in a commercial software, and the curve referred from [9]. The result using the magnetization curve based on the experiment is compared with the results using the other curves. The magnetic field around the center and the homogeneity are investigated, they are important for the design of the NMR magnet systems. II. ANALYSIS MODEL A. Magnetization Curves (BH curves) To investigate the influence of the magnetic property on the computation accuracy, the three magnetization curves called, BH, and BH3, as shown in Fig. 1 and, are employed. Fig. 1 shows the enlarged view of the BH curves in the range of the relatively low magnetic field, and Fig. 1 shows the BH curves in the range including the significantly high magnetic field. The curve is the experimentally obtained curve, where the relative permeability ( r ) equals to 1.0 on the significantly high magnetic field over T. The magnetic property in the range from 0 to 5.5 T was reported in [8], where the sample material is a magnetic steel sheet (Fe with 3wt% Si). The BH curve is used in a commercial magnetic field analysis software. The BH curve in the range from 0 to 0.10 MA/m is almost the same as the curve since the BH curve in the range of the low magnetic field is also obtained from the experiments. However, the BH curve over the significantly high magnetic field is extrapolated from the measurement data in the low magnetic fields, and the relative permeability on the saturation field is approximately 1.035. The

BH3 curve is calculated by the fitting curve equations given as [9] 191.3033 8.69673 ( B 8.69673 8.69673 199 ( B ) 8.69673 ( B ) ) 7.69673 (0 B (1 B 1) (1).56) () 1063.37( B ) 713. (.56 B ) (3) 1063.37 where is the reluctivity and B is the magnetic flux density, respectively. The material is also the magnetic steel. These equations are convenient to be used in the finite element method with the Newton-Raphson method [9]. Magnetic Flux Density B (T) Magnetic Flux Density B (T).0 1.5 1.0 0.5 BH BH3 0.0 0.00 0.004 0.006 0.008 0.010 Magnetic Field H (MA/m) 6.0 4.0.0 BH BH3 0.0 0.4 0.8 1. 1.6.0.4 Magnetic Field H (MA/m) and BH Fig. 1. The magnetization characteristic curves (BH curves) used as the characteristic of the iron shield. The is the experimentally obtained curve. The BH is the extrapolated curve from the measurement data, used in a software. The BH3 is calculated from the fitting curve equations. BH curves of relatively low magnetic field. BH curves with high magnetic field B. Magnet Configurations In the paper, two MRI magnet systems designed in the previous papers [6], [7] are employed. The first magnet has an iron shield and an active shield as shown in Fig., and the other magnet has only an iron shield as shown in Fig., where j is the current density of coils. These magnet configurations were designed to generate 1.5 T magnetic field with high homogeneity. In addition, the analysis results with two times current density are also investigated, because to generate the higher magnetic field (approximately 3.0 T) is targeted, such as NMR. The high magnetic field causes the magnetic saturation of the iron shield. In this paper, the analysis results of the former current density (to generate 1.5 T) are called Case 1-L and Case -L in order, and the analysis results of the two times current density (approximately 3.0 T) are called Case 1-H and Case -H, respectively. z(cm) 0 z(cm) 70.0 Main Coils 55.0 50.0 84.0 5.73 5.38 5.38 Shield Coil.60 j = 56.499 MA/m 5.39 5. Main Coils 16.0 0. 1.0 8.0 14.0 9.1666.0 7.97 8.68 9.3 Iron Shield 44.0 8.0 r(cm) j = 54.060 MA/m 46.0 30.0 14.77 3.7 16.36 60.0 84.0 7.0 1.95 5.06 55.0 7.55 0 Iron Shield r(cm) Fig.. The high field magnet configurations. The active shield and iron shield are installed as the magnetic shielding (Configuration 1). Only iron shield is installed (Configuration ). III. RESULTS AND DISCUSSION A. Evaluation Method In the paper, the magnetic field generated by the magnets mentioned above is computed by the finite element method using the nonlinear magnetization curves,, BH and BH3. To evaluate the influence of the magnetic property on the magnetic field around the center and the homogeneity, the magnetic fields B i (i=0,,31), as shown in Fig. 3, are computed and compared each other. B ~B 30 B 1 ~B 0 B ~B 10 Fig. 3. The points to evaluate the magnetic fields B i (i=0,,31). B. Configuration 1 on Low Magnetic Field (Case 1-L) For the magnet configuration 1, generating 1.5 T, the

magnetic fields computed using the, BH and BH3 curves are shown in Fig. 4, the absolute and relative differences are also shown in Fig. 4. As seen in Figs. 4 and, the BH3 differences are much larger than the BH at all points. It shows that the difference of analysis result strongly depends on the difference of the magnetization curves. That is, the BH3 curves differ from the actual data even in the range of the low magnetic field (below T), as seen in Fig. 1. In Fig. 4, the BH difference is nearly 0. The reason is that both the and BH curves are obtained from the experiments below T. Fig. 5. Result on Case1-H (3.0 T). Magnet flux density B i (i=0,,31). The differences between the curve and the others. The upper graph shows the BH, and the lower graph shows the BH3. Fig. 4. Result on Case 1-L (1.5 T). Magnet flux density B i (i=0,,31). The differences between the curves and the others. The upper graph shows the BH, and the lower graph shows the BH3. C. Configuration 1 on High Magnetic Field (Case 1-H) For the configuration 1 generating the higher magnetic field, the magnetic fields computed using the, BH and BH3 curves are shown in Fig. 5, the absolute and relative differences are also shown in 5. As seen in Figs. 5 and, the BH3 differences are also much larger than the BH at all points. However, in Fig. 5, the result of the BH is slightly different from that of the. The reason is that the magnetic permeability of the BH over the saturation field is 1.035, not equal to that of the. D. Configuration on Low Magnetic Field (Case -L) For the configuration generating the low magnetic field, the magnetic fields computed using the, BH and BH3 curves are shown in Fig. 6, the absolute and relative differences are also shown in 6. As seen in Fig. 6, even the result of the BH doesn t correspond with that of the. The reason is that a little difference of the magnetic property causes a large difference of the magnetic fields since a lot of iron is used. Even when the iron is exposed to the low magnetic field, we have to pay attention to choosing the magnetic property curve. Fig. 6. Result on Case-L (1.5 T). Magnet flux density of B i (i=0,,31). The differences between the curve and the others. The upper graph shows the BH, and the lower graph shows the BH3. E. Configuration on High Magnetic Field (Case -H) For the configuration generating the higher magnetic field, the magnetic fields computed using the, BH and BH3 curves are shown in Fig. 7, the absolute and relative differences are also shown in 7. As seen in Fig. 7, the tendency mentioned above is clearly observed. The result of the BH3 is especially awful.

Fig. 7. Result on Case-H (3.0 T). Magnet flux density B i (i=0,,31). The differences between the curve and the others. The upper graph shows the BH, and the lower graph shows the BH3. F. Field Homogeneity The magnetic field homogeneity on each case is shown in Table I, where the function F of the magnetic field homogeneity is defined as Bmax Bmin F (4) B0 where B max and B min are the maximum and the minimum values among B i (i=0,,31), respectively. As seen in Table I, the computed magnetic field homogeneity is also affected by the used BH curve. The field homogeneity of the NMR and MRI magnets is one of the most important factors. It is, therefore, necessary to use the correct BH curve obtained from the experiments in the high magnetic field. Comparing the with the BH in Table I, a little difference of the curves influences the field homogeneity. TABLE I MAGNETIC FIELD HOMOGENEITY Magnetic Field Homogeneity Function F Case BH BH3 Case1-L 0.089 0.089 0.088 Case1-H 0.086 0.086 0.086 Case-L 0.00080 0.0008 0.00105 Case-H 0.000160 0.000169 0.000586 G. Discussion The BH3 curve is useless since it differs from the experiments in the region of not only the high magnetic field but also the low magnetic field. When the BH curve is employed, it is necessary to take care of the strength of the magnetic field applying to the iron shield. The differences of the magnetic fields in the cases of the Configuration are larger than that in the cases of the Configuration 1. The reason is the placement and amount of the iron shield. The iron shield of the Configration is put on near the main coils to reduce the stray magnetic field, and it is exposed to the high magnetic field. Therefore, the difference of the BH curves appears slightly. Such a difference shouldn t be disregarded, because the NMR magnet systems require the magnetic field homogeneity in ppm order. The obtained tendencies are summarized as follows. 1. The higher the magnetic field is, the larger the difference between the results and the others is, because the difference among the magnetization (BH) curves are larger in the high magnetic field (over T).. Putting on the iron shield near the main coils, the difference becomes large, because the iron shield is exposed to the high magnetic field. 3. The magnetic field homogeneity is also affected by the difference of magnetization curves. Recent years, it is possible to measure the magnetization data of ferromagnets, and a lot of experiment data will be reported. When the analysis of the highly homogeneous and high-field superconducting magnet with iron shield, such as NMR, is performed for the design, we should pay more attention to the magnetic property of the iron. IV. CONCLUSION In the paper, the magnetic fields generated by the superconducting magnets with different configurations were computed by using three magnetization curves of the iron. From the results, the higher the magnetic field is, the larger the difference between the computed magnetic fields using the magnetic property based on the experiment data and the others, even if the curve prepared in a commercial software was used. These differences can t be disregarded at the design stage of NMR magnets. Therefore, we should pay attention to the magnetic property of the iron when the analysis is performed. REFERENCES [1] A. Ishiyama and H. Hirooka, Magnetic Shielding for MRI Superconducting Magnets, IEEE Trans. Magn., vol. 7, no., 1991, pp. 169 1695. [] K., Kominato, and et al., Development of Novel Spectroscopic Magnet Combining Mass Spectroscopy With Nuclear Magnetic Resonance, IEEE Trans. Appl. Supercond., vol. 0, no. 3, 010, pp. 736 739. [3] P. Vedrine, and et al., Iseult/INUMAC Whole Body 11.7 T MRI Magnet Status, IEEE Trans. Appl. Supercond., vol. 0, no. 3, 010, pp. 696 701. [4] H. Kitaguchi, and et al., Development of a Bi-3 HTS Magnet for 3T MRI System for Human Brains, IEEE Trans. Appl. Supercond., vol. 0, no. 3, 010, pp. 710 713. [5] T. Kiyoshi, and et al., HTS-NMR: Present Status and Future Plan, IEEE Trans. Appl. Supercond., vol. 0, no. 3, 010, pp. 714 717. [6] S. Noguchi and A. Ishiyama, Optimal Design Method for MRI Superconducting Magnets with Ferromagnetic Shield, IEEE Trans. Magn., vol. 33, no., 1997, pp. 1904 1907. [7] S. Noguchi and A. Ishiyama, An Optimal Design Method for Magnetic Shields of MRI Superconducting Magnets by Using Equivalent Magnetization Current Method, Proceedings of 15th International Conference on Magnet Technology, Part Two, 1998, pp. 1414 1417 [8] C. Kaido, T. Wakisaka, M. Mizokami, and M. Tanaka, Magnetic Properties of Electrical Steel Sheets at High Flux Density, T. IEE Japan, vol. 118-A, no. 9, 1998, pp. 109 1034 (in Japanese). [9] H. Tsuboi, T. Naitoh, and et al., Practical Numerical Electromagnetic Field Analysis Method, Yokendo, Tokyo, 1995, p. 30 (in Japanese).