Development of Integrated Filtration System for Water Treatment and Wastewater Reclamation in Developing Countries

Similar documents
Simultaneous removal of particles and dissolved organic matter in floating media filter for surface water treatment

Advanced water and wastewater treatment technologies in Thailand

Experimental Investigation of Adsorption-Flocculation-Microfiltration Hybrid System in Wastewater Reuse

Evaluation of Conventional Activated Sludge Compared to Membrane Bioreactors

NOVEL PRE-TREATMENT METHOD FOR SEAWATER REVERSE OSMOSIS: FIBRE MEDIA FILTRATION

Phosphorous Removal using Tertiary UF How Low Can You Go? and Other Design Considerations

Ultrafiltration Technical Manual

Performance of Hybrid Submerged Membrane Bioreactor Combined with Pre- Coagulation/Sedimentation

Comparing the Leopold Clari-DAF System to Upflow Contact Clarification

Make Water Anywhere with Pall Integrated Membrane Systems

Flocculation Flotation Pretreatment Improves Operation of MBR Installed to Treat Snack Food Manufacturing Wastewater

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

E.L. Batsari 1, A.K. Tolkou 1, A.I. Zouboulis 1, P.K. Gkotsis 1, E.N. Peleka May 2015, President Hotel, Athens

Meeting SB1 Requirements and TP Removal Fundamentals

Advanced Treatment by Membrane Processes

Water Reuse: identifying the optimal solution for the desired water quality. Didier PERRIN Technical & Marketing Director Degremont Asia

The Application of Flat Ultra-Filtration for Rainwater Reuse

MEMBRANE BIOREACTORS FOR RO PRETREATMENT

MBRs The Future of Wastewater Treatment PURON MBR. Tim Jordan KMS Midwest RSM

MEMBRANE BIOREACTORS (MBR)

Chapter 4: Advanced Wastewater Treatment for Phosphorous Removal

Pilot Study of Integrated MF-based MBR and UF for Drinking Water Production by Treating Micropolluted Source Water

13. High Rate Filtration Process

Bio-solar purification : A new process to treat domestic wastewater and to turn water and wastes in a safe reusable form

Membranes & Water Treatment

Air Connection on Rack. Filtrate Connection on Rack

Containerized Ultrafiltration (UF) Water Treatment Plant

Case Study: Parkson DynaSand D2 Filtration and Compliance Jessy Matthew John, The Probst Group

2018 MAY PAC Water Treatment

Reclamation of Sand Filter Backwash Effluent using HYDRAcap LD Capillary UF Membrane Technology

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

Cau Nguyet Water Treatment Plant Hai Phong, Vietnam

Water Treatment Technology

Pilot Studies on Performance of Membrane Bio-Reactor in Treating Hong Kong Freshwater and Saline Sewage and Its Virus Rejection Ability and Mechanism

Depth Filtration with Microfiber Cloth Enhances Performance of Ultrafiltration as Pretreatment to Seawater Desalination Systems

Innovative concept for Ultrafiltration systems: Integration of ultrafiltration cartridges and strainer in a single vessel

AL-KAWTHER INDUSTRIES LTD

Using of membrane processed for water treatment in the world

CeraMac -19 Demonstration plant Ceramic Microfiltration at Choa Chu Kang Waterworks G.Galjaard, J.Clement, W.S. Ang, M.H. Lim

Module 23 : Tertiary Wastewater Treatment Lecture 39 : Tertiary Wastewater Treatment (Contd.)

Studying Flux Decline in Hollow fiber Microfiltration unit using Domestic Wastewater

Recent Advances in Membrane Technologies Peter D Adamo, Ph.D., P.E Spring Conference Wilmington, NC April 13, 2015

Membrane BioReactor: Technology for Waste Water Reclamation

Fuzzy Filter: The Right Path for Graton Community Services District

International Journal of Science, Environment and Technology, Vol. 4, No 5, 2015,

RESTRICTED URBAN REUSE OF KONYA (TURKEY) MUNICIPAL WASTEWATER TREATMENT PLANT EFFLUENTS VIA RECLAIMED WATER DISTRIBUTION SYSTEM

EVALUATION OF NEWLY DEVELOPED MEMBRANE BIOREACTORS FOR WASTEWATER RECLAMATION

Improved Membrane Design Addresses Integrity Issues for the City of Yuba City Water Treatment Plant

Operating parameters influencing Ultrafiltration of organic model solutions

Analysis of Urban Sewage Treatment in Environment Engineering Lu Fu

MEMBRANE BIOREACTORS (MBR) AND REVERSE OSMOSIS (RO) FOR LEACHATE TREATMENT. Abstract

Appendix D JWPCP Background and NDN

MEMBRANE PILOT FOR A DIRECT REUSE APPLICATION: ENGINEERING AN MF/UF & RO PILOT. Ignacio Cadena, P.E. Freese and Nichols, Inc.

Drinking Water Treatment Overview Filtration and Disinfection

THE COMAG SYSTEM FOR ENHANCED PRIMARY AND TERTIARY TREATMENT

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent

ULTRAFILTRATION FOR REVERSE OSMOSIS-PRETREATMENT

Improvement of Drinking Water Plant Treatment

SYSTEMATIC APPROACH TO WATER TREATMENT PLANT PROCESS OPTIMIZATION

Wastewater Treatment Processes

Dundalk Wastewater Treatment Plant

Leopold Desalination Pretreatment Systems

Scientific & Technical Report

Key words: Integrated Membrane System, IMS, Seawater Reverse Osmosis, SWRO, SW30HRLE- 400, Ultrafiltration, UF, ZeeWeed 1000

THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS

Lowering The Total Cost Of Operation

DEVELOPMENT OF THE. Ken Mikkelson, Ph.D. Ed Lang Lloyd Johnson, P.E. Aqua Aerobic Systems, Inc.

ACTIFLO Process For Drinking Water Treatment WATER TECHNOLOGIES

Water4Crops Session; IFAT India th -10 th October, Mumbai, India

Sulaibiya world s largest membrane water reuse project

Validation Testing of a High Rate Disk Filter For Water Recycling Applications

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

Phosphorus Removal Treatment Alternatives

WASTE WATER RECYCLE MANAGEMENT ION EXCHANGE INDIA LTD

Drinking Water Production Using Moving Bed Filtration

IMMERSED MEMBRANE TECHNOLOGY: ELIMINATING BARRIERS TO LAND DEVELOPMENT

Leachate treatment by direct capillary nanofiltration. Hans Woelders Second Intercontinental Landfill Research Symposium Asheville NC, October 2002

RETROFITTING SMALL WATER SYSTEM TO MEET NEW REGULATIONS. David Reyne

Integrated Ozone Enhanced Biofiltration for Water Reuse

Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources

Science Exploration. DHRITI BHATTACHARJEE Class : VII/C Roll No : 31

Water Treatment. Water Treatment. Water Treatment. Water Treatment. CIVL 1101 Introduction to Filtration 1/15

Innovating Water Treatment Technologies in Managing Water-Energy Demand

Nakhon Sawan Water Treatment Plant Nakhon Sawan, Thailand

min) with the exception of the Fuzzy Filter that was operated at 800 L/m 2 min (20 gal/ft 2 min)

Technical White Paper

Seasonal Source Water Quality and Treatment Challenges Town of Newburgh s Chadwick Lake Filtration Plant

Water Purification by Electrocoagulation

Application of EDR for Wastewater Reclamation and Reuse in Electrolytic Galvanizing Line

Membrane Systems. Featuring Aqua MultiBore Membranes

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

Hetch Hetchy Treatability at the Sunol Valley Water Treatment Plant

Novel Pretreatment Enables Performance of MBR Installed to Treat Oily Wastewater

Agenda. Pretreatment Background Typical Contaminants Practical Examples Methods of Treatment and References

surface and wastewater desalination by electro dialysis reversal

Reverse Osmosis. Lecture 17

Description. Development

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager

EVALUATION OF MF/UF CHEMICAL CLEANING STRATEGIES IN DIRECT POTABLE REUSE APPLICATIONS. Introduction

Transcription:

Development of Integrated Filtration System for Water Treatment and Wastewater Reclamation in Developing Countries C. Chiemchaisri Department of Environmental Engineering Faculty of Engineering, Kasetsart University, Bangkok 19, Thailand

Introduction - Bangkok, like other mega cities in developing countries, is suffering from the shortage of water resources due to the deterioration of natural water qualities. - To overcome these problems, efficient water treatment systems for producing good quality water supply and treated wastewater for reuse are needed. - Integrated filtration system employing floating media filter coupled with conventional sand/ zeolite filter or membrane filtration was developed for water treatment and wastewater reclamation purposes.

Integrated Filtration System - Filtration is an essential unit for solid separation in conventional water treatment and tertiary wastewater treatment processes. - Its applications include direct filtration of low turbidity water or filtration of coagulated water for high turbidity water. - In this study, floating media filtration system coupled with coarse c sand filter/ zeolite bed/ microfiltration membrane was applied d to the treatment of surface water and secondary effluent. - The advantages of system include smaller footprint comparing to conventional water treatment processes, high treatment efficiency and low operating cost.

Floating media filter coupled with coarse sand filter or zeolite bed for surface water treatment and wastewater reclamation

Floating media filter coupled with microfiltration membrane for surface water treatment

Polypropylene bead Laboratory scale experimental unit Hollow fiber membrane module

Pilot scale testing at Bangkhen water treatment plant Floating media filter Microfiltration membrane unit

Research series on Integrated Filtration System 1. Floating media/coarse sand filter for surface water treatment (lab scale) - turbidity removal 2. Floating media filter coupled/zeolite bed for wastewater reclamation (lab scale) - turbidity, N, P removals 3. Floating media filter/mf membrane for surface water treatment (lab scale) - turbidity, NOM, microorganism removals 4. Floating media filter/mf membrane for surface water treatment (pilot scale) - turbidity, NOM removals

Floating media filter/coarse sand filter for surface water treatment - Coagulants - Filtration rates - Media depth Alum, FeCl 3, PACl, polymer 5,8,12 m 3 /m 2.h 6:2, 5:3, 4:4, 3:5, 2:6 cm and 1.5 m of floating media filter alone Key findings Appropriate filtration rate of the system was found to be 5 m 3 /m 2.h, It was limited by the particle retention capacity of floating media filter and headloss development in coarse sand filter When only floating media filter of 1.5 m was used, the filtration rate of 15 and 1 m 3 /m 2.h could be maintained to obtain satisfied effluent turbidity level in long term operation.

Turbidity removal and headloss development: Effect of filtration rate Turbidity (DFF) (NTU) 3 25 2 15 1 5 5m/h 8m/h 12m/h Turbidity (DFF+CSF) (NTU) 25. 2. 15. 1. 5. 5 m/h 8 m/h 12 m/h 2 4 6 8 Filtration time (h). 2 4 6 8 Filtration time (h) Headloss (DFF) (cm) 12 1 8 6 4 5m/h 8m/h 12m/h Headloss (DFF+CSF) (cm) 14 12 1 8 6 4 5 m/h 8 m/h 12 m/h 2 2 2 4 6 8 Filtration time (h) 2 4 6 8 Filtration time (h)

Turbidity removal and headloss development: Effect of bed depth Turbidity (DFF) (NTU) 16. 14. 12. 1. 8. 6. 4. 6:2 5:3 4:4 3:5 2:6 Turbidity (DFF+CSF) (NTU) 16. 14. 12. 1. 8. 6. 4. 6:2 5:3 4:4 3:5 2:6 2. 2.. 2 4 6 8 Filtration time (h). 2 4 6 8 Filtration time (h) Headloss (DFF) (cm) 8 7 6 5 4 3 2 6:2 5:3 4:4 3:5 2:6 Headloss (DFF+CSF) (cm) 8 7 6 5 4 3 2 6:2 5:3 4:4 3:5 2:6 1 1 2 4 6 8 Filtration time (h) 2 4 6 8 Filtration time (h)

Relationship between L/d and turbidity removal in plastic media pre-filter Turbidity removal (%) 1 95 9 85 8 75 7 65 6 55 5 45 3 mm 6 mm 8 mm 25 5 75 1 125 15 175 2 225 25 275 3 bed depth:media size(l/d)

Floating media filter/ zeolite bed for wastewater reclamation - Direction filtration of secondary effluent from sewage treatment plant (particle removal) - Chemical precipitation (for P removal) using FeCl 3 and zeolite bed (for N removal) Key findings - Filtration rates - Media depth 1,3,5 m 3 /m 2.h 4:4 cm A filtration rate of 5 m 3 /m 2.h was proposed for direct filtration mode (only turbidity removal) whereas 1 m 3 /m 2.h was recommended for N, P removal from secondary effluent.

Treated water qualities for N, P removal and breakthrough period Parameters Std. Limit 1(m 3 /m 2.h) 3 (m 3 /m 2.h) 5 (m 3 /m 2.h) Eff. Hours Eff. Hours Eff. Hours SS (mg/l) < 5.4 >12 7. 9 1. 3 Turbidity (NTU) < 5.2 >12 4.7 1 46.5 3 NH 4 + (mg N/l) <5.9 >12 5.6 9 2.1 3 PO 4 3- (mg P/l) <.5.2 >12.13 8 1.18 3 Effluent Parameters Influent Range Average % Removal ph 7.3 5.6-6.4 6. SS (mg/l) 1.3-2.2.5 91.9 Turbidity (NTU)- DFF 6.8.1-1.5.7 9. Turbidity (NTU)- Overall 6.8.1-.9.3 94.6 BOD (mg/l) 18.3.7-1..9 95.4 NH + 4 (mg N/l) 22.5-7..5 97.8 PO 3-4 (mg P/l) 4.41 -.6.2 99.5

Floating media filter/mf membrane for Surface water treatment Floating Media Filter - Acrylic column of 1 cm. diameter and 18 cm. long - Plastic media: Polypropylene (PP) bead of 3.6 mm diameter 1 m. bed depth Microfiltration Membrane Unit - Hollow filter membrane module with.1 μm m pore size and.2 m 2 surface area Filtration rate 5, 1, 15 m 3 /m 2.h Coagulant Polyaluminum chloride (PACl) at 25%, 5% and 1% of jar test Key findings Floating media filter was effective in promoting flocculation and a removing solid particles from raw water Low filtration rate (5 m 3 /m 2.h) was preferred to prevent breakthrough and reduce the solid particle loading to MF membrane

Particle removal in floating media filter (RW turbidity 8 NTU) Turbidity (NTU) 1 9 8 7 6 5 4 3 2 1 PACl 8 mg/l PACl 4 mg/l PACl 2 mg/l 3 6 9 12 15 18 21 24 27 3 33 36 Time(min) V = 5 m/hr Opt. dose 1% Opt. dose 5% Breakthrough of particles Turbidity(NTU) 1 9 8 7 6 5 4 3 2 1 PACl 8 mg/l PACl 4 mg/l PACl 2 mg/l 3 6 9 12 15 18 21 24 27 3 33 36 Time(min) V = 1 m/hr Turbidity(NTU) 1 9 8 7 6 5 4 3 2 1 PACl 8 mg/l PACl 4 mg/l PACl 2 mg/l 3 6 9 12 15 18 21 24 27 3 33 36 Time(min) V = 15 m/hr

SS(mg/l) 2 18 16 14 12 1 8 6 4 2 12 min 24 min 36 min..2.5.7 1. 1.3 1.6 Depth(m) V = 5 m/hr PACl 8 mg/l Floc Size(um) 2 15 1 5 12 min 24 min 36 min Release of small particles from floating filter..2.5.7 1. 1.3 1.6 Depth(m) V = 5 m/hr PACl 8 mg/l SS(m g/l) 1 8 Accumulation of solid particles In floating media filter 6 4 2 12 min 24 min 36 min..2.5.7 1. 1.3 1.6 Depth(m) V = 1 m/hr 4 PACl 4 mg/l Floc Size(um) 3 2 Deeper accumulation In the filter bed 1 12 min 24 min 36 min..2.5.7 1. 1.3 1.6 Depth(m) V = 1 m/hr PACl 4 mg/l

Effect of turbidity and particle size on transmembrane pressure development of MF membrane Transmembrane Pressure(kPa) 2 18 16 14 12 1 8 6 4 2 8 NTU V=.6 m/d V=1. m/d V=1.4 m/d V=5 m/hr V=1 m/hr DFF+MF MF 1 2 3 4 5 6 7 8 Turbidity(NTU) Transmembrane Pressure(kPa) 2 15 1 5 8 NTU V=.6 m/d V=1. m/d V=1.4 m/d V=5 m/hr V=1 m/hr MF DFF+MF 1 2 3 4 5 6 7 8 9 1 Floc Size(um) MF membrane removed the remaining turbidity in water yielding constantc effluent turbidity. Transmembrane pressure development was low following the pretreatment by floating media filter

NOM removal in floating media filter/mf system Key findings High degree of NOM removal (>85%) was achieved in the system. Enhanced coagulation effect provided more than 8% of UV 254 removal in floating media filter. NOM removal results in significant reduction in chlorine demand and THM formation. Both turbidity and NOM concentration affected the fouling of membrane but TMP built up was mainly caused by particulate fouling

UV 254 removal during coagulation of river water UV removal (%) 1 9 8 7 6 5 4 alum-medium turbidity 3 PACl-medium turbidity FeCl3-medium turbidity 2 alum-high turbidity 1 PACl-high turbidity FeCl3-high turbidity 5 1 15 2 25 3 35 4 Coagulant dose (mg/l) PACl was found to be the most effective coagulant for NOM removal. Optimum dose was 15-25 mg/l giving 75-9% UV 254 removal. 1 Relationship between turbidity and UV 254 removal in floating media filter UV removal (%) 8 6 4 2 y =.8969x R 2 =.9578 y =.7213x R 2 =.95 2 4 6 8 1 Turbidity removal (%)

Turbidity and NOM removal in floating media filter/mf system Condition Turbidity (NTU) UV 254 (cm -1 ) 1. PACl 1% 1.1 PP (7.5 m/h) MF (.3 m/d) 1.2 PP [11 m/h) MF (.45 m/d) 2. PACl 5% 2.1 PP (7.5 m/h) MF (.3 m/d) 2.2 PP (11 m/h) MF (.45 m/d) Avg. %Removal Avg. %Removal 15.9.53 18.8.55 25.4.59 17.2.61 85.5 99.5 83.8 99.5 76.7 99.5 78.7 99.2.147.12.18.11.2.12.198.11 8.7 86.6 76.6 85.7 72.6 83.6 66.4 81.3 Parameters ph Turbidity (NTU) UV 254 (cm - 1 ) DOC (mg/l) Color (TCU) Range 7.65-7.84 7.84.51-.68.68.6-.11.11 2.78-2.99 2.99 2.8-3.6 Value Avg. 7.73.6.8 2.88 3.2

25 TMP (kpa) 2 15 1 5.45 m/d-1%.3 m/d-1%.45 m/d-5%.3 m/d-5% 2 4 6 8 1 12 14 16 18 2 22 24 Time (hours) TMP development in MF membrane unit Effect of raw water qualities (Turbidity and UV 254 ) on TMP development TMP increase (kpa) 1 9 8 7 6 5 4 3 2 1 T.6 U.5 T1.3 U.3 T66 U.6 T16 U.16 T66 U.3 T16 U.3 Raw water qualities

Reduction in Cl 2 demand and THM formation.5 to 1. mg/l reduction in chlorine demand was achieved after removing NOM from the water. THM formation was reduced by 4-6% Sample Cl 2 dose (mg/l) CHLO ( g/l) DCBM ( g/l) DBCM ( g/l) Sum of THM ratio RW 2. 2.5 71 138 6 9.45.44.5.8 3. 3.5 5. 129 145 175 9 9 11.47.54.55.8.9 1.1 TW 2. 2.5 3. 3.5 5. 33 46 67 73 86 4 6 8 8 9.38.59.7.74.76.2.3.5.5.6 Sum of THM = C CHLO (WHO guideline) CHLO /GV CHLO CHLO + C DCBM DCBM /GV DCBM DCBM + C DBCM DBCM /GV DBCM DBCM + C BROMO BROMO /GV BROMO BROMO < 1

Water borne microorganism removal by floating media filter/mf membrane Key findings Freshwater algae was found partially removed by coagulation and entrapped in floating media filter but completely retained by MF membrane Total coliform and Fecal coliform was effectively removed by coagulation c and retained in floating media filter at low filtration rate (5 m/h) At higher filtration rate, total and fecal coliform removal efficiencies ficiencies were significantly reduced. Nevertheless, MF membrane helped removing the remaining TC and FC from water Coliphage was removed better in floating media filter operated at higher filtration rate but poorly retained by MF.

Microorganisms (MPN/1 ml, PFU/ml) 1 1 1 1 1 1 Floating filter No coagulant: 5 m/h 1 2 3 4 5 6 TC FC CP Microorganisms (x1 4 MPN/1ml, PFU/ml) 1 1 1 1 Floating filter 14 (a) 12 1 8 6 4 2 Turbidity (NTU) Microorganisms (MPN/1 ml, PFU/ml) 1 1 1 1 1 1 1 with coagulant:5 m/h 1 1 2 3 4 5 6 Operation Time (Hour) Improved FC removal improved CP removal No coagulant:15 m/h Microorganisms (MPN/1ml, PFU/ml) 1 1 1 1 1 2 4 6 8 Operation Time (Hour) TC CP FC NTU penetration of CP Through MF (b) MF 7 6 5 4 3 2 1 Turbidity (NTU) 1 1 2 3 4 5 6 1 2 4 6 8 Operation Time (Hour)

Future research needs & possible collaboration - Investigation of trace pollutants (e.g. pesticide, pharmaceuticals) cals) contamination in surface water/treated wastewater in floating media and membrane filtration system - Enhancement of NOM removal by floating media bio-filtration or photo-oxidation oxidation associated with MF membrane for polluted water treatment - Detailed investigation of microorganism removal in floating media filter coupled with MF membrane treating actual river water. w - Implementation of full scale integrated filtration system at BangkokB waterworks and sewage treatment plants

Other research collaborations - Development of photosynthetic bacteria pond system for carbon recovery from industrial wastewater (with UT) - Investigation of reverse osmosis (RO) membrane fouling during reclamation of textile wastewater (WRPC & UT) - Application of membrane bioreactor (MBR) and RO system to solid waste leachate treatment (UT)

Full scale application of advanced leachate treatment system (1 m 3 /d) in Thailand