Evaluation Report CCMC R Pieux Vissés Vistech / Postech Screw Piles

Similar documents
Evaluation Report CCMC R HELICAL PILE

Evaluation Report CCMC R ALMITA HELICAL SCREW PILE

Evaluation Report CCMC R Trex Transcend Decking

Evaluation Report CCMC R Suretouch

Evaluation Report CCMC R Murphy LVL

Evaluation Report CCMC R Fiberon Solid Decking- Horizon, Horizon Symmetry, Sanctuary, and Protect Advantage

Evaluation Report CCMC R Superior Walls Xi Precast Concrete Insulated Wall Panels

Evaluation Report CCMC R MetalWorks StoneCrest and MetalWorks AstonWood Steel Shingles

Evaluation Listing CCMC L EverGuard TPO Roofing Products

Evaluation Report CCMC R AZEK Deck

Trex Wood-Polymer Composite Lumber

Evaluation Report CCMC R Nordic I-Joist Series

Gerard Shingle, Granite Ridge, and Guardian Shingle

Evaluation Report CCMC R Isofoil

Evaluation Report CCMC R DMX Drain 5M (Drainage)

Evaluation Report CCMC R ZIP System Sheathing and Tape

Evaluation Report CCMC R Sto Guard - Air Barrier Material

Evaluation Report CCMC R Surround HouseWrap - Air Barrier Material

TimberTech Solid Core Decking 5/4 Plank, TwinFinish and EarthWood

Evaluation Report CCMC R Tyvek HomeWrap - Air Barrier Material

Evaluation Listing CCMC L Nordic X-Lam

Evaluation Listing CCMC L EcoBay CC CAN / EcoBay CC Arctic CAN

Evaluation Listing CCMC L Icynene ProSeal (MD-C-200v3)

Power JoIst ADI-40, ADI-60, ADI-80 I-joists

This opinion is based on the CCMC evaluation of the technical evidence in Section 4 provided by the Report Holder.

Evaluation Report CCMC R Excel Air Barrier

1. Opinion. 2. Description. 1 of 5. MasterFormat: Evaluation issued:

Evaluation Listing CCMC L Boreal Lavender and Boreal Nature

Product Information Bulletin

Evaluation Report CCMC R Demilec Air Barrier System

Evaluation Report CCMC R Icynene ProSeal Air Barrier System

Evaluation Report CCMC R FOAMULAR CodeBord Air Barrier System (CABS)

Spray-Applied Rigid Polyurethane Foam Insulation, Medium Density

Novabrik CCMC R. EVALUATION DIVISION REPORT Issued Re-evaluated Revised Re-evaluation

Mineral-Fibre Thermal Insulation for Buildings

Evaluation Report CCMC R Colphene ICF, ICF Foundation Membrane, Membrane de Fondation ICF (for dampproofing)

Evaluation Report CCMC R NUDURA Waterproofing Membrane

Evaluation Report CCMC R LP SolidStart LVL

CCMC. Graftex CCMC R. EVALUATION DIVISION REPORT Issued

Evaluation Report CCMC R WALLTITE v.2 - Air Barrier System

Evaluation Report CCMC R Parallam PSL

Cellulose Fibre Insulation (CFI) For Buildings

1. Opinion. 2. Description. MasterFormat: Evaluation issued: Re-evaluated: Evaluation revised:

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

SECTION 552 HELICAL ANCHORS AND HELICAL PILES

Originally Issued: 05/18/2018 Valid Through: 05/31/2019

Arxx High Performance Wallsystems

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICE EVALUATION CRITERIA FOR

Evaluation Report CCMC R Microllam LVL

SHORING & UNDERPINNING 02250

MATERIAL SPECIFICATION FOR DECK JOINT ASSEMBLIES

MATERIAL SPECIFICATION FOR DECK JOINT ASSEMBLIES

TERRATORQUE HELICAL ANCHORS AND HELICAL PILING PRODUCT CATALOG

METAL FABRICATION..1 General Conditions and Division 1 shall govern Work of this section.

The Footing Tube. Evaluation Report GGMC R. lssued:

Evaluation Report CCMC R StoGuard (w/ Sto Gold Coat and Sto Gold Fill ) sheathing membrane

Evaluation Report CCMC R Insulspan Structural Insulated Panel (SIP) System

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GOLIATHTECH INCORPORATED 175B RUE PELADEAU MAGOG, QUEBEC J1X 5G9 CANADA

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GEOTECH ENTERPRISES, INC.

Evaluation Report CCMC R Insulspan Structural Insulated Panel (SIP) System

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: EMPIRE PIERS 2656 EAST HWY 47 WINFIELD, MO EVALUATION SUBJECT:

Helical Pile/Anchor Deep Foundation MODEL SPECIFICATION

MATERIAL SPECIFICATION FOR DECK JOINT ASSEMBLIES

MATERIAL SPECIFICATION FOR SECTIONAL STEEL HIGH MAST LIGHTING POLES

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

MATERIAL SPECIFICATION FOR DECK JOINT ASSEMBLIES

CONSTRUCTION SPECIFICATION FOR FOOTINGS AND PADS FOR ELECTRICAL EQUIPMENT

Evaluation Report CCMC R TimberStrand LSL

Product Guide Specification

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: CANTSINK MANUFACTURING, INC. 71 FIRST AVENUE LILBURN, GEORGIA 30047

Sport Systems Canada Inc. Section Angle Framed Bleachers Page 1

.2 Section Waste Management and Disposal.

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: TECHNO-PIEUX INC. EVALUATION SUBJECT:

MATERIAL SPECIFICATION FOR SECTIONAL STEEL HIGH MAST LIGHTING POLES

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HELICAL ANCHORS, INC BOONE AVENUE, NORTH MINNEAPOLIS, MINNESOTA 55428

Agrément Certificate 18/5477 website: Product Sheet 1

SECTION STRUCTURAL STEEL

Do not place bundles of deck so as to overload the supporting structure.

.2 Section Metal Fabrications: Steel channel frame to suit metal door and operator.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: IDEAL MANUFACTURING, INC. 999 PICTURE PARKWAY WEBSTER, NEW YORK 14580

Section Steel H-Piling Tender No. [ ] Page 1

National Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 [ ].

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: MAGNUM PIERING, INC. 156 CIRCLE FREEWAY DRIVE CINCINNATI, OHIO 45246

AMBICO Limited 7\2018 Section and OVERSIZED METAL DOORS AND FRAMES Page 1

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

AMBICO Limited Section BULLET RESISTANT SLIDING STEEL DOOR ASSEMBLY Page 1

Special Provision No. 109S17 June 2017

Special Provision No. 915S03 December References, Materials, Construction, and Quality Assurance for Sign Support Structures

Division MEDICAL EQUIPMENT SUPPORT SYSTEMS PART 1 GENERAL

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

AMBICO Limited Section and ACOUSTIC STEEL WINDOW FRAME ASSEMBLIES Page 1

MATERIAL SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

MATERIAL SPECIFICATION FOR STEEL REINFORCEMENT FOR CONCRETE

DBI-SALA Uni 8 Horizontal Lifeline Cable System

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POLES

ASTM STANDARDS FOR COLD-FORMED STEEL

Transcription:

Evaluation Report CCMC 13102-R Pieux Vissés Vistech / Postech Screw Piles 1. Opinion MASTERFORMAT: 31 62 16.01 Evaluation issued: 2003-02-13 Re-evaluated: 2018-01-04 Re-evaluation due: 2021-02-13 It is the opinion of the Canadian Construction Materials Centre (CCMC) that Pieux Vissés Vistech / Postech Screw Piles, when used as an augered steel pile in a foundation system in accordance with the conditions and limitations stated in Section 3 of this Report, complies with the National Building Code 2015: Clause 1.2.1.1.(1)(a), Division A, using the following acceptable solutions from Division B: ᵒ Clause 4.2.3.8.(1)(e), Steel Piles ᵒ Sentence 4.2.3.10.(1), Corrosion of Steel ᵒ Sentence 4.2.4.1.(1), Design Basis ᵒ Subclause 9.4.1.1.(1)(c)(i), General (Structural Requirements) ᵒ Sentence 4.3.4.1.(1) Design Basis for Structural Steel This opinion is based on CCMC s evaluation of the technical evidence in Section 4 provided by the Report Holder. Ruling No. 04-16-120 (13102-R) authorizing the use of this product in Ontario, subject to the terms and conditions contained in the Ruling, was made by the Minister of Municipal Affairs and Housing on 2009-11-30 (revised on 2012-07-27) pursuant to s.29 of the Building Code Act, 1992 (see Ruling for terms and conditions). This Ruling is subject to periodic revisions and updates. 2. Description The product is an earth anchor constructed of helical-shaped circular steel blade(s) that is (are) welded to a steel shaft. The blade is constructed as a helix with a carefully controlled pitch. The anchors come in seven pile types: P178, P238, P312, P400, P412, P512, and P658. Table 2.1 indicates the properties for each pile type. Table 2.1 Properties of the Product Pile Type Type Exterior diameter of post Wall thickness of post Diameter of helix blade Thickness of blade Pile P178 48 mm 3.7 mm Pile P238 60 mm 3.9 mm 200 mm 200 mm 8 mm 8 mm 9.5 mm Pile P312 89 mm 5.5 mm 9.5 mm 1 of 5

Type Exterior diameter of post Wall thickness of post Diameter of helix blade Thickness of blade Pile P400 101 mm 5.7 mm Pile P412 114 mm 6.0 mm Pile P512 140 mm 6.5 mm Pile P658 168 mm 7.1 mm 610 mm 610 mm 660 mm 9.5 mm 9.5 mm The anchor type and blade diameter are chosen based on the bearing capacity of the soil and the load the auger-installed steel pile is designed to support. The central shaft is used to transmit torque during installation and to transfer axial loads to the helical plate. The central shaft also provides most of the resistance to lateral loading. The foundation system comes with various other accessories, such as plates to adapt to the building structure, extension shafts and connectors which conform to CAN/CSA G40.21-13/G40.21-13. All accessories with treaded rods conform to ASTM A325M. The steel shaft, blades and accessories conform to the 350 MPa requirement of CAN/CSA G40.20-13/G40.21-13, General Requirements for Rolled or Welded Structural Quality Steel/Structural Quality Steel or ASTM A 500/A 500M-10a Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes. They have a galvanic coating that meets the 610 g/m 3 requirement of ASTM A123M, Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products. All welders at Pieux Vistech / Postech Screw Pile Inc. are certified in accordance with the Canadian Welding Bureau to produce welds conforming to CSA W59-13, Welded Steel Construction (Metal Arc Welding). Figure 1 shows a typical steel pile with a single helical blade. 2 of 5

Figure 1. Pieux Vissés Vistech / Postech Screw Piles 3. Conditions and Limitations CCMC s compliance opinion in Section 1 is bound by the Pieux Vissés Vistech / Postech Screw Piles being used in accordance with the conditions and limitations set out below. The product may be used as part of a foundation system to support various constructions, provided that it is installed according to the manufacturer s current instructions and within the scope of this Report. When the product is installed in granular soil or silt, there is a direct relationship between the applied torque and the allowable compressive and tensile loads. Table 3.1 indicates the allowable compressive and tensile loads as a function of the applied torque. When the product is installed in a cohesive soil, such as clay, there is a direct relationship between the applied torque and the allowable compressive and tensile loads. Table 3.2 indicates the allowable compressive and tensile loads as a function of the applied torque. When the auger-installed steel pile is installed in a soil with granular material that exceeds 200 mm in diameter, the relationship between the applied torque and the allowable compressive and tensile loads is not as predictable. When it is installed in such soils, the allowable compressive and tensile loads have to be confirmed by on-site load tests. These load tests are also required if the allowable loads need to be greater than those stated in Tables 3.1 or 3.2. The tests need to be conducted under the direct supervision of a professional geotechnical engineer, skilled in such design and licensed to practice under the appropriate provincial or territorial legislation. In all cases a registered professional engineer skilled in such design and licensed to practice under the appropriate provincial or territorial legislation must determine the number and spacing of the auger-installed steel piles required to carry the factored loads. A certificate attesting to the conformity of the installation and the allowable loads for the piles must be provided by a certified installer. The installation of the auger-installed steel pile must be carried out as per the manufacturer s instructions. The Pieux Vissés Vistech / Postech Screw Piles must be screwed into the ground to below the frost line using mechanized equipment. The anchor is rotated into the ground with sufficient applied downward pressure (crowd) to advance the anchor one pitch distance per revolution. The anchor is advanced until the applied torque value attains a specified value. Extensions are added to the central shaft as needed. The applied loads may be tensile (uplift), compressive (bearing), shear (lateral), or a combination thereof. Helical anchors are rapidly installed in a wide variety of soil formations using a variety of readily available equipment. They are immediately ready for loading after installation. The installer of the proposed auger-installed steel piles must be certified by Pieux Vistech Postech Screw Piles Inc. Using approved equipment, the installer must follow the manufacturer s installation instructions and the uses and limitations specified in this Report. Each installer must carry a certification card bearing their signature and photograph. Each Pieux Vissés Vistech / Postech Screw Pile must be identified with a label containing the following information: ᵒ manufacturer s identification; and ᵒ the phrase CCMC 13102-R. 3 of 5

Table3.1 Allowable Compressive and Tensile Loads for the Product in Granular Soil or Silt (1) Applied Torque 678 500 20 4500 4 900 1 017 750 24 5400 8 1800 1 356 1 000 29 6525 11 2475 1 695 1 250 34 7650 14 3150 2 034 1 500 39 8775 18 4050 2 373 1 750 44 9900 21 4725 2 712 2 000 49 11025 25 5625 3 051 2 250 53 11925 31 6975 3 390 2 500 58 13050 31 6975 3 728 2 750 63 14175 35 7875 4 068 3 000 68 15300 40 9000 4 407 3 250 73 16425 44 9900 4 746 3 500 78 17550 48 10800 5 085 3 750 82 18450 50 11250 5 424 4 000 87 19575 52 11700 5 763 4 250 92 20700 54 12150 6 102 4 500 97 21825 56 12600 6 441 4 750 102 22950 58 13050 6 780 5 000 107 24075 60 13500 7 119 5 250 112 25200 62 13950 7 458 5 500 116 26100 64 14400 7 797 5 750 121 27225 66 14850 8 136 6 000 126 28350 68 15300 Note to Table 3.1: (1) The allowable loads identified in this Table are only valid when the product is installed in granular soil or silt. The applied torque is the average of the values attained within the last 500 mm of installation. Special attention is required when the augerinstalled steel piles are installed in a recently backfilled site or where the granular material exceeds 200 mm in diameter. In these cases, Table 3.1 does not apply and the allowable loads need to be determined by on-site confirmatory testing. In cohesive soils, the values in Table 3.2 apply. Table 3.2 Allowable Compressive and Tensile Loads for the Product in Cohesive Soil (1) Applied Torque 1 017 750 8 1800 6 1350 1 356 1 000 11 2475 8 1800 1 695 1 250 14 3150 10 2250 2 034 1 500 17 3825 12 2700 2 373 1 750 19 4275 14 3150 2 712 2 000 22 4950 16 3600 3 051 2 250 25 5625 19 4275 3 390 2 500 28 6300 21 4725 4 of 5

Applied Torque 3 728 2 750 31 6975 23 5175 4 068 3 000 33 7425 25 5625 4 407 3 250 36 8100 27 6075 4 746 3 500 39 8775 29 6525 5 085 3 750 42 9450 32 7200 5 424 4 000 44 9900 34 7650 5763 4250 47 10575 36 8100 6102 4500 50 11250 38 8550 Note to Table 3.2: (1) The allowable loads identified in this Table are only valid when the product is installed in a cohesive soil. The applied torque is the average of the values attained within the last 500 mm of installation. 4. Technical Evidence The Report Holder has submitted technical documentation for CCMC s evaluation. Testing was conducted at laboratories recognized by CCMC. The corresponding technical evidence for this product is summarized below. 4.1 Performance Requirements The proposed auger-installed steel piles were tested to ASTM D 1143/D 1143M-07(2013), Standard Test Methods for Deep Foundations Under Static Axial Compressive Load, ASTM D 3689/D 3689M-07(2013)e1, Standard Test Methods for Deep Foundations Under Static Axial Tensile Load, and ASTM D 3966/D 3966M-07(2013)e1, Standard Test Methods for Deep Foundations Under Lateral Load. Testing was conducted on four different sites across Canada. Two sites had granular and clay soil; the other two had cohesive soil. A series of 32 tests were performed. The intent of the testing was to determine a correlation between the torque applied during installation and the allowable loads. In the granular and silt-based soils and in the cohesive soils, there was a good correlation between the torque applied during installation and the allowable loads. In the granular and silt-based soils, for the compressive loads noted in Table 3.1, the factor of safety varied from 1.7 to 3.0. For the tensile loads, the factor of safety varied from 2.0 to 2.4. For the lateral loads, no correlation was possible. Report Holder Pieux Vistech - Postech Screw Piles Inc. 10 260 boulevard Bourque Sherbrooke, QC J1N 0G2 Telephone: 819-843-3003 Fax: 819-843-0793 Plant(s) Disclaimer Sherbrooke, QC This Report is issued by the Canadian Construction Materials Centre, a program of NRC Construction at the National Research Council of Canada. The Report must be read in the context of the entire CCMC Registry of Product Evaluations, including, without limitation, the introduction therein which sets out important information concerning the interpretation and use of CCMC Evaluation Reports. Readers must confirm that the Report is current and has not been withdrawn or superseded by a later issue. Please refer to http://www.nrc-cnrc.gc.ca/eng/solutions/ advisory/ccmc_index.html, or contact the Canadian Construction Materials Centre, NRC Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6. Telephone (613) 993-6189. Fax (613) 952-0268. NRC has evaluated the material, product, system or service described herein only for those characteristics stated herein. The information and opinions in this Report are directed to those who have the appropriate degree of experience to use and apply its contents. This Report is provided without representation, warranty, or guarantee of any kind, expressed, or implied, and the National Research Council of Canada (NRC) provides no endorsement for any evaluated material, product, system or service described herein. NRC accepts no responsibility whatsoever arising in any way from any and all use and reliance on the information contained in this Report. NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity. Date modified: 2018-01-18 5 of 5