Overview of NIST s JCTLM Activities: Past, Present, and Future. Karen W. Phinney Biomolecular Measurement Division

Similar documents
NIST: Mission, Metrology, and Standards. NBMC Workshop Blood, Sweat, & Tears III November 2-3, 2016

Providing Traceability for Protein Biomarkers

Examples of reference materials

International Standards for Biotechnology

JCTLM Structure and future funding of the JCTLM Secretariat

JCTLM Introduction A global approach to improve reference systems. Mathias M. Müller Austria

Chinese regulations on IVDs and traceability requirements

Objectives. Understand and give examples of the problems which result from lack of comparability of patient results

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

The national infrastructure for traceability in laboratory medicine in China

The Centre for Metrological Traceability in Laboratory Medicine (CIRME): scope and activities. Mauro Panteghini CIRME Director

Laboratory Reagents. for life science research.

What is the purpose of this website?

DISCOVERY AND VALIDATION OF TARGETS AND BIOMARKERS BY MASS SPECTROMETRY-BASED PROTEOMICS. September, 2011

CLSI C60: Assay Validation & Post-Validation Monitoring

Joint Committee for Traceability in Laboratory Medicine JCTLM Report for CCQM Meeting, April 2018

Quantitative Proteomics: From Technology to Cancer Biology

Technical Assessment (TA) Summary Form (M00116)

Neue Technologien für die patientennahe personalisierte Diagnostik

Capabilities & Services

The Direction of Thermo Fisher Scientific

Traceability & Uncertainty. Accreditation Experience. David Ducroq. Weqas. Unit 6, Parc Tŷ Glas. Llanishen. Cardiff.

A Briefly Review of. Accredited Reference Measurement Laboratories in China. 1 Accreditation of Reference Measurement Laboratories

A2LA. P113a Policy on Reference Material Traceability for Life Sciences Testing Laboratories

Complex Adaptive Systems Forum: Transformative CAS Initiatives in Biomedicine

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

Online affinity and digestion: A flexible and robust tool for the characterization and quantification of proteins

UK Biobank Past, Present, and Future

LETI-HEALTH. Adrienne Pervès Deputy Director LETI Technologies for Biology and healthcare Department

Traceability in laboratory medicine: what is it and why is it important for patients?

Certified Reference Materials for Laboratory Medicine

Specific Accreditation Guidance. Scope of accreditation - service descriptors for animal health

Your bridge to. better medicines

Conference Exhibitors

Exposing Myths, Legends and Tales About Reference Materials. Presented by: Matt Sica - ANAB Steve Arpie Absolute Joe Konschnik - RESTEK

Clinical Chemistry Approach to Evaluation of Commutability

Agilent Solutions for Metabolomics YOUR PATH TO SUCCESS

About ICarbonX. Learn more:

IMPROVE SPEED AND ACCURACY OF MONOCLONAL ANTIBODY BIOANALYSIS USING NANOTECHNOLOGY AND LCMS

Ready, Set, Test! AACC Conference Mass Spectrometry in the Clinical Lab: Best Practice and Current Applications September 17-18, 2013 St.

WAIT! Ready, Set, Test! Financial Disclosure. Research/Educational grants/consulting/salary support

HARMONIZATION TEAM A6 (STABILITY) UPDATE. Yoshiaki Ohtsu 8 March 2012

About HFL. Markets & services. Markets & services. Qualitative MS: Pharmaceutical Applications. Regulatory Framework

Metabolomics: Techniques and Applications ABRF

Microfluidics as an enabler for Medical Diagnostics

Pushing the Leading Edge in Protein Quantitation: Integrated, Precise, and Reproducible Protein Quantitation Workflow Solutions

GENE EXPRESSION REAGENTS MARKETS (SAMPLE COPY, NOT FOR RESALE)

FQS Accreditation for forensic testing agencies NEMC ANSI-ASQ National Accreditation Board

The road to a perfect EQA-programme

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

See More, Much More Clearly

Best Practices for the Use of International Standards in Vaccine Testing Dianna Wilkinson

Getting the Right Answer The Importance of Traceability

Pharmaceutical LC/MS Solutions from Agilent Technologies

A Primer on Reference Materials Matthew Sica Environmental Program Manager

Agilent 6490 Triple Quadrupole LC/MS System REACH ULTIMATE SENSITIVITY WITH BREAKTHROUGH IFUNNEL TECHNOLOGY

Regulatory Issues and Drug Product Approval for Biopharmaceuticals

Improving the Detection Limits for Highly Basic Neuropeptides Using CESI-MS

Development, Optimization and Validation of Luminex based cytokine assays

BIOCRATES Life Sciences AG Short Company Presentation

IMPORTANCE OF CELL CULTURE MEDIA TO THE BIOPHARMACEUTICAL INDUSTRY

Spårbarhet och harmonisering kraftfulla verktyg för riktighet i laboratorieresultat

Justification, Instrument Selection, and Due Diligence for Successful Implementation of MS. Objectives. Clinical Justification

New Approaches to Quantitative Proteomics Analysis

JCTLM Update: Organization and Achievements

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

CIRME: ten yearsafter. Prof Mauro Panteghini CIRME Scientific Coordinator

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications

Metrological Traceability and Assay Standardization in Laboratory Medicine. STRESA, ITALY May 24, 2013

M.Tech. in Clinical Engineering

LCMS methods and traceability of CSF biomarker measurements

From Genotype to Phenotype

Best Practices for the Use of International Standards in Vaccine Testing Dianna Wilkinson

Lecture 23: Clinical and Biomedical Applications of Proteomics; Proteomics Industry

Evolution Triple Quadrupole GC-MS/MS. Transforming the best GC-MS system into something even better.

Process for comparing certified values of the same measurand in multiple reference materials (CRMs)

Pharmaceuticals and Biotechnology

the biomarker testing laboratory

Dr. Robert L. Moritz Director Proteomics Research Insitutute for Systems Biology

The Future of Reimbursement for Lab Developed Mass Spec Assays

IBBL: Introduction to Biobanks and their services

Considerations for Successful Biomarker Bioanalysis in Regulated Environment

King George's Medical University UP., Lucknow center for advance research

Guideline/Guidance Comparison on Ligand Binding Assays (LBA)

S3A:Note for guidance on toxicokinetics: The assessment of systemic exposure in toxicity studies. Q&A: FOCUS ON MICROSAMPLING

Guideline/Guidance Comparison on Ligand Binding Assays (LBA)

Pharmacokinetic Analysis of the mab Adalimumab by ELISA and Hybrid LBA/LC/MS: A Comparison Study

CRYSTAL CITY V REDUX: GUIDANCE FOR INDUSTRY BIOANALYTICAL METHOD VALIDATION DRAFT GUIDANCE (2013) VI. ADDITIONAL ISSUES

AdvanceBio Peptide Mapping

Application Note. Authors. Abstract

MRG: Metabolomics Research Group

Basic Information. I.1 If your company performs biotechnology research and development, uses a. The Categories of Biotechnology Applications.

Understanding CRM Second Source and Stability. Joe Konschnik RESTEK Corporation

LC/MS Based Quantitation of Intact Proteins for Bioanalytical Applications

MRC-NIHR National Phenome Centre

PHARMACEUTICAL REFERENCE STANDARDS

Guideline for the quality, safety and efficacy of follow-on biological medicinal products

Understanding life WITH NEXT GENERATION PROTEOMICS SOLUTIONS

Update from NIBSC Standardisation Activities. Elaine Gray

Transcription:

Overview of NIST s JCTLM Activities: Past, Present, and Future Karen W. Phinney Biomolecular Measurement Division

Structure of NIST s Laboratory Programs Undersecretary of Commerce for Standards and Technology & NIST Director Willie May Associate Director for Management Resources Mary Saunders Associate Director for Laboratory Programs Richard Cavanagh (acting) Special Programs Office Richard Cavanagh Physical Measurement Laboratory Material Measurement Laboratory Engineering Laboratory Information Technology Laboratory Center for Nanoscale Science and Technology NIST Center for Neutron Research Two Metrology Laboratories Two Technology Laboratories Two National User Facilities

Material Measurement Laboratory National reference laboratory for measurements in the chemical, biological, and material sciences MML serves a broad range of industry sectors ranging from transportation to biotechnology and provides research, measurement services, and measurement quality assurance tools for addressing problems of national importance such as: assessment of climate change renewable energy the nation s aging infrastructure environmental quality food safety and nutrition forensics and homeland security health care measurements manufacturing (ranging from advanced materials to photovoltaics to biologic drugs) MML is also responsible for coordinating the NIST-wide Standard Reference Materials and Standard Reference Data programs

Material Measurement Laboratory R. Watters, Assoc Dir for Measurement Services Office of Reference Materials Office of Data & Informatics L. Locascio, Director M. Fasolka, Deputy Director Lab Office N. Alderoty, Exec Officer Executive Officer Division Chiefs Materials Science and Engineering (642) Materials Measurement Science (643) Biosystems and Biomaterials Science (644) Biomolecular Measurement (645) Chemical Sciences (646) Applied Chemicals and Materials (647)

NIST Involvement in Laboratory Medicine Pure substance CRMs Certified for purity Suitable for calibration Continued Growth More methods and materials First fresh-frozen serum CRMs Strategic Focus Precision Medicine Microbial Metrology 1970s 1990s 2000s Future 1980s Definitive Methods Focus on traditional clinical markers First matrix CRMs (freeze-dried) New Areas Protein biomarkers Clinical DNA Speciation New CRM matrices

NIST JCTLM Database Listings Category Reference Materials Reference Methods Blood cell counting 0 0 Blood gases 0 0 Blood groupings 0 0 Coagulation factors 0 0 Drugs 16 4 Electrolytes 24 16 Enzymes 0 0 Metabolites and substrates 32 14 Microbial serology 0 0 Non-electrolyte metals 43 15 Non-peptide hormones 1 8 Nucleic acids 0 0 Proteins 2 0 Vitamins and micronutrients 9 2

x10 x10 x10 x10 x10 2 0.8 0.6 0.4 0.2 2 1 0.8 0.6 0.4 0.2 2 1 0 0.8 0.6 0.4 0.2 2 1 0 0.8 0.6 0.4 0.2 2 1 0 1 0.8 0.6 0.4 0.2 0 +ESI MRM Frag=140.0V CID@20.0 (446.4 -> 299.1) 0505201410.d 1 1 1.86122654 2.181751 +ESI MRM Frag=115.0V CID@30.0 (460.5 -> 194.1) 0505201410.d 1 1 1.823906 2.2018314 +ESI MRM Frag=135.0V CID@30.0 (474.4 -> 299.1) 0505201410.d 1 1 +ESI MRM Frag=135.0V CID@30.0 (474.4 -> 284.1) 0505201410.d 2.62120 3.1447519 3.177699 3.44386 3.69624 1 1 +ESI MRM Frag=100.0V CID@12.0 (442.4 -> 295.1) 0505201410.d 1 1 3.1570926 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 Counts (%) vs. Acquisition Time (min) Evolution of CRM Approaches SRM 1955 Homocysteine and Folate in Human Serum Three level reference material Low level achieved by dilution with PBS High level achieved by spiking Certified value for 5-methyltetrahydrofolate Reference value for folic acid SRM 3949 Folate Vitamers in Human Serum THF 5m-THF 5f-THF MeFox Folic acid Screening and blending of donor serum units Wider range of folate values Some donors given a folic acid supplement Stabilization of minor folate species Improvements in analytical methods Will replace SRM 1955 (mid-2016)

Evolution of CRM Approaches o SRM 900 Antiepilepsy Drug Level Assay Standard issued in 1978 o Lyophilized material with 3 levels (plus a blank) of phenytoin, ethosuximide, phenobarbital, and primidone o Value assignment by gas and liquid chromatography What changed? o Development of next generation of antiepilepsy drugs o Changes in treatment practices o Customer preference for fresh-frozen serum o Development of ID LC-MS and ID LC-MS/MS methods

SRM 900a Antiepilepsy Drugs in Human Serum Analyte Level 1 (µg/ml) Level 2 (µg/ml) Phenobarbital 17.1 (3.5) 70.2 (3.3) Phenytoin 11.9 (3.4) 47.0 (3.2) Lamotrigine 4.02 (3.2) 14.9 (3.4) Topiramate 7.05 (3.3) 19.7 (4.1) Concentrations of antiepilepsy drugs in new SRM 900a. Concentrations determined by ID LC-MS and ID LC-MS/MS. Relative expanded uncertainties given in parentheses.

Prioritization of Reference Method and Reference Material Development Support for national or international standardization efforts Cholesterol Creatinine Hormones Cardiac troponin I Urine albumin Need identified by another government agency Vitamin D metabolites Toxic elements Iodine Folates Fatty acids Needed to aid full realization of diagnostic test potential Genome sequencing Proteomics Metabolomics

Updates and CRMs in Development RM/SRM Name RM 8398 Human DNA for Whole-Genome Variant Assessment SRM 2373 Genomic DNA Standards for HER2 SRM 2378 Fatty Acids in Human Serum SRM 956d Electrolytes in Human Serum SRM 909c Frozen Human Serum SRM 2972a 25-Hydroxyvitamin D Calibration Solutions SRM 972a Vitamin D Metabolites in Human Serum Comments New, Genome in a Bottle Consortium New New Now includes value for phosphorus Values added for electrolytes Additional concentrations added, now includes 3-epi-25(OH)D 3 Values added for total 25(OH)D and 24R,25(OH) 2 D 3 SRM 971 Hormones in Human Serum Values for T3 and T4 to be added in 2016 SRM 2924 C-Reactive Protein Solution Expected release mid-2016 SRM 2925 Human Serum Albumin Solution Expected release in 2016 SRM 3666 Albumin and Creatinine in Human Urine Candidate materials being acquired

Engineering biology Develop the measurements and models for engineering biology to map out the fundamental principles that drive development of next generation biobased products (high tech manufacturing, health) Looking Ahead Microbial Measurements Develop measurement infrastructure for microbial measurements (health, environment) Data and Informatics Provide validated data and informatics tools to support confident decision-making (all sectors) Quantitative Tools for Characterization of Complex Biologics Define complex biomolecules/biologics through quantitative measurements to enable prediction of biological function in healthcare applications (manufacturing, health) Precision Medicine Develop measurement science and standards to ensure confidence in clinical decisionmaking, and ultimately enable adoption of precision medicine (health)

Looking Ahead MML recently issued a five year strategic plan Outlines priorities in biological, chemical, and materials sciences Includes a focus on precision medicine, microbial metrology Available online: mmlstrategy.nist.gov

Goal 1a: Measurement Science Excellence: Biological Sciences Strategies Complex Biotherapeutics Develop measurement science, standards and tools to support the quantitative definition of complex biologic therapeutics and correlation of their structural differences with clinical outcomes. Engineering Biology Develop the measurements and models for engineering biology to map the fundamental principles that drive the development of the next generation of bio-based products. Reproducibility of Biomedical Research Establish NIST as the agency for measurement assurance to enable reproducibility of biomedical research results. Microbial Metrology Develop measurement infrastructure for microbial measurements in health and environmental applications. Precision Medicine Develop measurement science and standards to ensure confidence in clinical decision-making, and ultimately enable adoption of precision medicine.

For More Information NIST Office of Reference Materials: www.nist.gov/srm or srminfo@nist.gov Material Measurement Laboratory: http://www.nist.gov/mml/ karen.phinney@nist.gov