METHODOLOGY The process starts with a collection of available information, continued by an audit in loco, it is

Similar documents
SIMULATION VERSUS REALITY 4 CASE STUDIES. Anthony Calderone Aurecon, Melbourne, Australia

A HYBRID MONITORING-MODELING PROCEDURE FOR ANALYZING THE PERFORMANCE OF LARGE CENTRAL CHILLING PLANTS

POTENTIAL FOR THE ENERGY EFFICIENCY ADVANCEMENT IN DISTRICT HEATING AND COOLING PLANT BY RENOVATION

ENERGY MODELING TOOLS: SOLUTIONS FOR CREATING A HIGH PERFORMANCE BUILDING. Presented by Neil Maldeis Energy Solutions Engineering Leader, Trane

Retro-commissioning and on-going commissioning 23 November 2016

Great Ocean Rd Ice Creamery

A Key Component of Environmental Sustainability Efforts and a Source of Substantial Cost Savings for FCGU. Dr. Simeon Komisar

Case study of an ECBC Compliant, Energy Efficient Building: Aranya Bhawan, Jaipur

Sample Reports. for. HAP v4.80 Example Problem

LIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

Retrofit Demonstration in Brazilian Commercial and Public Buildings

Building Performance Evaluation Guide

Hidden Energy Saving Opportunities in Tertiary Education Buildings

Energy Modeling Tools Solutions for Creating an Intelligent Building

Indo-Swiss Building Energy Efficiency Project. Case Study: Aranya Bhawan, Jaipur

WAKE TECHNICAL COMMUNITY COLLEGE SUSTAINABLE ENERGY PLAN. Energy Plan

NWC District Energy Campus Energy - RFQ Supporting Documentation. April 25, 2018

Implications of Measured Commercial Building Loads on Geothermal System Sizing

Analysis II Energy Considerations for Green Roofs

California Independent System Operator Corporation. California ISO. Import resource adequacy. Department of Market Monitoring

SCHOOL ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

USE OF SIMULATION TOOLS FOR MANAGING BUILDINGS ENERGY DEMAND. Alberto Hernandez Neto, Flávio Augusto Sanzovo Fiorelli

Streamlining Energy Simulation To Identify Building Retrofits

ECBC Impacts: Experiences from the ECBC Pilot Building in Rajasthan Jyotirmay Mathur Malaviya National Institute of Technology Jaipur, India

Strategies for energy efficiency improvement in residential and office buildings: their role at building and country scale

Greening Your Business Energy Efficiency in Buildings

Sample Reports. for. HAP v4.90 Example Problem

Heriot-Watt University

Normal Children's Discovery Museum, LEED Silver:

COMPUTER SIMULATION AND EXPERIMENTAL VALIDATION OF A MODERN HOTEL ON BUILDING ENERGY CONSERVATION

Green Building Parameters & Case Studies

Building Load and Energy Estimates Analysis. Instructor: Dr. Mumma. October 28, Thesis Building Sponsor s: INOVA Fairfax Hospital

A New Type of Hybrid Groundwater Energy System

THE IMPACT OF GLAZING SELECTION ON DAYLIGHTING AND ENERGY PERFORMANCE FOR AN OFFICE BUILDING IN CANBERRA

Continuous Commissioning Leading Energy Project Process - An Industry Approach

Green Star Shopping Centre Design PILOT Energy Calculator Guide

Energy Consumption Analysis and Energy Conservation Evaluation of a. Commercial Building in Shanghai

Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

Timmins and District Hospital

Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001

Aotearoa Park Shopping Centre Sample Type 1 Energy Audit

PLANNING SUSTAINABLE IN CHINESE CITIES: DWELLING TYPES AS A MEANS TO ACCESSING POTENTIAL IMPROVEMENTS IN ENERGY EFFICIENCY

Heat Pump Field Trials and Implications for Design

Clean Energy Extension

Rainwater tank study of new homes

ENERGY EVALUATION BY SIMULATION FOR EFFECTIVE USE OF SEWAGE HEAT

Mechanical Tech Report 2

Retrocommissioning Investigation Study of the Sheraton Chicago Hotel

Modeling and analyzing solar cooling systems in Polysun

New developed solar thermal systems for heating and cooling Budapest, 16 th April 2009 Tsekouras Panagiotis Mech. Engineer NTUA Centre for Renewable

ENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN

National Indian Gaming Association 2005 Certification: Energy Management for Cost Savings Larry Kinney Synertech Systems Corporation On behalf of

Advantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure

PREDICTED VS. ACTUAL ENERGY SAVINGS OF RETROFITTED HOUSE

The energy benefits of View Dynamic Glass

NORTH AMERICAN MONITORING OF A HOTEL WITH ROOM SIZE GSHPS

Retrocommissioning (RCx)

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Uncalibrated Building Energy Simulation Modeling Results

Results and Recommendations from Energy Audit of Shageluk. For VEEP Grants Village of Shageluk, Alaska

Developing an Accurate Baseline for Electricity Consumption, Focusing on University Residence Halls

Xavier University of Louisiana

Innovative Solar thermal systems for heating and cooling

Greening Buildings at the Dallas/Fort Worth International Airport. Sustainable Communities Conference Dallas, TX. March 10, 2009

OPTIMIZATION OF ICE THERMAL STORAGE SYSTEM DESIGN FOR HVAC SYSTEMS

Deep Energy Retrofit of a HighRise MURB

SUSTN Courses with Lab Applications. Overview of all SUSTN Core Classes: Highlighting Commissioning, Energy Auditing, and Measurement & Verification

equest Home Energy Model ME 514 ~ HVAC Sean Rosin University of Idaho/Boise State University Spring 2016

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates. Jeff S. Haberl, Ph.D., P.E.

Incentives. After work is complete:

ScienceDirect. Simulation based mixed mode building design

A CASE STUDY IN ACTUAL BUILDING PERFORMANCE AND ENERGY MODELING WITH REAL WEATHER DATA

Ground-Coupled Heat Pump And Energy Storage

Assessment of Building Energy Performance for EEMs A Case Study in Mumbai

Allstream Centre Energy Performance Report

Energy Modeling Applications for Existing Buildings

Energy 10/19/2011. Inc. New. Castle, DEE. Image. By: Skanska

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR COMMERCIAL OFFICE BUILDINGS

Twenty-first Century Building Design: Getting to Net-Zero Energy?

SURNA Grow Facility: Systems Comparison - IEA

Seminar 29. Urban Scale Building Energy Modeling, Part 5

METHOD FOR VALIDATION OF STATISTICAL ENERGY MODELS. Department of Mechanical Engineering, Dalhousie University Halifax.

Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations

Australian Solar Cooling Interest Group (ausscig) Conference Financial analysis of solar cooling systems in Australia

CONDENSING TEMPERATURE CONTROL THROUGH ENERGY MANAGEMENT SYSTEM SIMULATON FOR A LARGE OFFICE BUILDING

Simulation investigation of heating load for solid wall house retrofitted with Vacuum Insulation Panels

ANALYSIS OF ENVELOPE THERMAL BEHAVIOUR THROUGH PARAMETRIC STUDIES. Civil Engineer, PhD, Assistant Professor, Civil Engineering Department (3)

Streamlining Utility Billing Analysis and Reporting

BETTER BUILDINGS BY DESIGN Sheraton Conference Center Burlington, Vermont. February 8, 2012

Project : Power & Fuel consumption - an engineering initiative. VPS Rockland, Dwarka.

Zero Energy House in Japan: Actual results and future target. Isamu Ohta Misawa Homes Institute of Research & Development CO., LTD.

AEE Technical Roundtable Measurement and Verification. Alec Stevens, PE April 8, 2014

MATERIALS AND SUPPLIES INVENTORY

Monitoring-Based Commissioning Best Practices Award Welch Hall

Driving Efficiency with Interval Meter/Smart Meter Data. Mukesh Khattar, Energy Director, Oracle

Pharmaceutical Sustainability Initiatives

2/17/2017. Energy Accounting & Education. Topics (Electricity) Creating Electricity

Energy Management in Plastics Processing

Green Buildings Make Cents

Transcription:

Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001 METHODOLOGY FOR BUILDING MODELLING AND CALIBRATION FOR WARM CLIMATES A. Pedrini* and R. Lamberts** *Dept. of Architecture, The University of Queensland, Brisbane, QLD 4066 - Australia: alp4@bne.comcen.com.au **Dept. of Civil Engineering, Universidade Federal de Santa Catarina, Florianópolis, CxP 476 CEP 88040-900 - Brazil: lamberts@ecv.ufsc.br ABSTRACT In the last seven years, a method has been developed to analyse building energy performance using simulation, in Brazil. The method combines analysis of building documentation, and walk-thought visits, electric and thermal measurements, with climate analysis and the use of an energy tool (DOE2.1E code). The method was used to model more than fifteen office buildings (more than 200 000 m²), between 12.5 and 27.5 of South latitude. The paper describes the basic methodology and justifies it, using some results. INTRODUCTION A building model is often examined by some software, which allows the evaluation of current energy use as well as the prediction of the impact of energy saving actions in hypothetical refurbishments. As the reliability of these results is intrinsically related to the model s accuracy, it is necessary to consider how much effort (and resources) are necessary to produce a satisfactory model. This is the starting point for this paper, which presents a modelling and calibrating method with successive increasing levels of complexity and their impact on the results. Emphasis is laid on input and output tasks, since the software itself exists, it is well recognized and validated. The input aims to represent the building as an abstraction of the reality and this process determines the accuracy of the results. On the other hand, the output consists of reporting results of the simulations. The method was initially based on procedures reported in internal reports by Kaplan Engineering (Kaplan, 1991; Kaplan, 1992), and articles such as Haberl and Komor (1990), Koran et al., (1993), Corson (1992) and others and the first proposal was presented in the master thesis of Pedrini (1997), in the Building Energy Efficiency Laboratory (LABEEE/ UFSC/ Brazil). Since then, the method has been modified to allow variations, adapting itself to different building cases. METHODOLOGY The process starts with a collection of available information, continued by an audit in loco, it is improved with monitoring and air conditioning efficiency determination. The main parameter of model acceptance is the comparison of monthly energy consumption between the real and simulated performance. The phases of this process are described in the following paragraphs. The first step involves an evaluation of the building documentation, without actually visiting the site. The intention is to use only existing information to avoid unnecessary expenses, and to estimate the potential saving for the building before investing into trips to the location. As the analyst need no contact with the building, the distance of the building is irrelevant. This is a strong advantage for countries like Brazil and Australia, due the continental distances between cities. The checklist for this task is: Architectural plans: used to identify geometries and lay-outs, construction layers, window areas and others, derived from site and floor plans, sections and construction details such as roof, wall, windows and exterior shading. Electric lighting system: the information sources are electrical project plan and the nominal characteristics of luminaries available in catalogues. Air conditioning secondary system: air distribution plan, and report with design characteristics such as cooling and heating set points, supply air and exterior air flows for each zone, total and sensible cooling capacity, EER and fan nominal power and flow. Air conditioning primary system: cooling water distribution plan, chiller characteristics such as model and year, COP as well as efficiency at 100%, 75%, 50% and 25%, cooling capacity, chilled water supply temperature, cooling management, chiller schedule report (this is routinely monitored every day). Building schedule for lighting, occupants (total number of occupants) and air conditioning. - 1367 -

Equipment inventory: number of computers and other equipment with considerable energy consumption. Historical monthly energy consumption (at least one year). Hourly energy consumption for a representative period, usually available from the energy supply company. Building component properties: special features must be characterized in detail (such as windows in buildings with large window/wall ratio), which must be available in catalogues and manuals published by the supplier. Using all these information, the first model is built using a software. Far too often inputs are assumed, due to lack in documentation. In this situation, a good library with appropriate defaults is extremely useful. Results of the first model (Figure 1) usually differs from the measured monthly consumption, but it is enough to identify discrepancies. consumption (MWh) 700 600 500 300 200 100 1995 measured first model The main sources of thermal loads and energy consumption are identified and the documentation is revised. The hourly energy consumption is also derived and compared with the monitored data. The differences are questioned and an audit walk-through is prepared. consumoption (kwh) 1600 1 1200 1000 800 600 0 month jan feb mar apr may jun jul aug sep oct nov dec 200 0 1 3 5 7 9 11 13 15 17 19 21 23 hour real weekday simulated weekday real weekend simulated weekend Figure 2: Hourly energy consumption comparison: simulated x real The second step is referred to as Walk-through audit phase. Using observations derived from the previous step, the analyst visits the building with a technician, who must be familiar with the operation of the building. Supplied with current plans and some colour pens, the analyst classifies the zones following criteria such as type of use, artificial lighting and climate control (Figure 3). Whenever possible, the analyst must confirm information about use, questioning the users, mainly cleaners and system operators. Figure 1: First model Figure 3 Zones classification. - 1368 -

During the visit, some measurements must be carried out. The first ones are instantaneous measurements using hand-held instruments (Figure 4) to check lighting levels, air flow, temperature, reactive and active power, and power factor in equipment, and representative sample of artificial lights. Frequently, nominal values for lighting power differ from the real ones especially with discharge lamps. This must be followed by measurements over a period (days, weeks or even month) for which accurate dataloggers are the appropriate tool ((Figure 4) The third step consists of schedule calibration and it is referred to as the End-use energy consumption phase. It consists of spliting the total energy consumption in to energy end-use by lights, equipments (plug-in type) and air conditioning, such as the typical weekdays energy consumption represented in the Figure 6. Usually, these measurements can be done in the transformer or main switch room, if the electrical system is sufficiently refined to identify circuits for each purpose. The results are utilized in the model schedule tuning. energy demand (kw) 1 1200 1000 800 600 200 0 1:00 6:00 11:00 16:00 21:00 hour Figure 4: Hand-held and diminutive dataloggers instruments (Watson, Crosbie et al. 1997) Sensors of temperature dataloggers are installed close to the air return in fan-coils chambers to measure an average temperature of the zones and the records quantify the setpoints and the schedule, as can be seen in the Figure 5, which has different curves for distinct zones. Also, the records can indicate if the air conditioning is properly doing its function. Equipment such as lifts, water pumps and others that can have excessive energy consumption must also be checked using some current meter dataloggers. weekday total energy equipment lights Cooling Figure 6: Total and end-use demand energy The fourth and last step aims to calibrate the cooling system characteristics: Air conditioning system characterization. The process begins with current recordings in pumps and cooling tower. At the same time, the water temperatures in the chillers, water flow and power consumption are monitored. Using the standard (ARI, 1998), the COP is calculated for similar conditions. 25 24 temperature ( C) 23 22 21 20 19 18 1:00 3:00 5:00 7:00 9:00 11:00 13:00 15:00 17:00 19:00 21:00 23:00 hour Figure 5: Temperature monitoring for different office rooms The results obtained in this phase are utilized to tune inputs such as lighting power density, equipment power density, cooling set point and use schedules. Figure 7: Temperature and efficiency curves - 1369 -

CONCLUSIONS All phases successively increase the model accuracy and the influence of each one depends on the quality of information and the building type. Just to illustrate the consequence of common errors during the model and simulation, the analysis of energy end use is presented for the Eletrosul building (Figure 8), relative to the four steps of modelling. In every calibration, the simulated results match the real consumption, as shown in Figure 9. Figure 8: Eletrosul (10 000 m²) The first model uses one data available in documentation, the second uses also monitoring information to redefine the schedules, the third uses energy end-use monitoring and the fourth models the cooling efficiency determination (COP) through measurements in situ. The results, presented in Figure 10, show an overestimate of lighting energy consumption, which decreases with the refinements of the model. On the other hand, plug-in equipment and HVAC are underestimated in the first model and successively increase in proportion. The main improvement is the energy end-use determination, while the COP estimate corrects cooling energy consumption. This modelling behaviour was checked again for 12 other buildings (analysed during 1996 and 2000) in Brazil, and all of them demonstrated the importance of monitoring. Monthly Energy Consumption (MWh) 500 480 460 440 420 380 360 340 320 300 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Month Measured Step I- Documentation Step II- Walk-through Step III- End-use recording Step IV- COP measurement Figure 9: Model calibrations The discrepancies between the first and the last model evidence the potential errors about building behaviour, when it is modelled. The information supplied by building occupants, as documents and reporting, and the walk-through audit are probably not enough to produce a reliable model, which can be obtained only from measurements and monitoring. The errors in energy end-use profile during a retrofit analysis can result in significant errors in payback estimate, sometimes of an unacceptable magnitude. The analyst must be conscious of the model limits and he/she must look for an appropriate balance between level of detail and reliability. annual energy consumption (Gwh) 100% 80% 60% 40% 20% 0% 79% 3% 18% Step I- Documentation 70% 16% 15% Step II- Walkthrough 36% 33% 31% Step III- End-use recording 30% 26% 44% Step IV- COP measurement lighting equipment cooling Figure 10: End use energy for different levels of modelling. - 1370 -

Bibliography ARI, A.-C. R. I. (1998). Standard for water chilling packages using the vapour compression cycle - Standard 550-590. Arlington, Virginia. Corson, G. C. (1992). Input-output sensitivity of building energy simulations. ASHRAE Transactions 92(1): 618-626. Haberl, J. S. and S. Komor (1990). Improving energy audits: How annual and monthly consumption data can help (part 1). ASHRAE Journal(August): 26-33. Kaplan, E. (1991). Energy Edge Modelers Guidelines Report. U.S.A., PORTLAND ENERGY CONSERVATION INC. Kaplan, E. (1992). Energy Edge Simulation Tuning Methodologies. U.S.A., PORTLAND ENERGY CONSERVATION INC. Koran, W. E., M. B. Kaplan, et al. (1993). Two DOE-2.1C model calibration methods. ASHRAE Special Publications: Thermal Performance of the Exterior Envelope of Buidings.: 3-10. Watson, D., M. J. Crosbie, et al. (1997). Time-saver standards for architectural design data. New York, McGraw-Hill. - 1371 -

- 1372 -