RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

Similar documents
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

OPTIMASS 7400 Technical Datasheet

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Diaphragm seal with flange connection With internal diaphragm Model

Flow Measurement SITRANS F M

VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet. Specification. The superior solution. Highlights. Applications.

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Diaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel

VERIS Accelabar. Superior Flow Measurement Accuracy

Diaphragm seal with flange connection Cell-type with extended diaphragm Model

Red Eye Multiphase Water-Cut Meter

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

ISO 9001:2008 certified

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Pressure transducers DMU 02 Vario (flush)

SECTION Coriolis Mass Flow Meters

FPD190 Differential pressure restriction orifice plates

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Volume Flow and Gas Flow Measuring Devices

Target Inline Flowmeter

Liquid level switch BW 17

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

Process Inline Filter, Change-Over

Wing Union/Hammer Union Pressure Sensors Models 434, 435, Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Mechatronic pressure measurement. Applications. Special features. Description

MAGFLO. Flow metering based on electromagnetic technology. For value-adding performance you can count on. FLOW DIVISION Simply Better

Micro Motion Technical Overview and Specification Summary

Technical Specifications and General Guidelines for Mass Flow Meters at Petroleum Oil Installations. Note:

Gilflo flowmeters. for steam, liquids and gases

COMBIMASS Thermal Gas Flow

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Visual Level Indicators VLI

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

Rosemount 405 Compact Orifice Primary Element

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Regulating valves REG 6-65, REG-SS 15-40

Digital E3 Modulevel Liquid Level Displacer Transmitter

SITRANS L Level instruments

Moisture analyzers (moisture meters) FIZEPR-SW100

Accutube Averaging Pitot Tubes

Vortex EX DELTA lowmeter Technical Specifications

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

Model B. Thermostatic Control Valves. Typical applications

DS-4018 English Rev. FA. ProPlate Flowmeter Mass ProPlate Flowmeter Model 1195 Integral Orifice

Electronic Master - Printed Copies Uncontrolled - Rosemount Proprietary

SAPAG. A full range of API 526 flanged safety relief valves for process applications, gas, steam and liquid. Safety Relief Valve Series 8100/8200

MGO INSULATED THERMOCOUPLES INDEX

Monolithic Isolation Fittings

Level Sensors 1001 Table of contents

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

NUFLO Liquid Turbine Flow Meters

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Thermocouple for Flue Gas Temperature Measurements,

Smart Displacement type Level Transmitter

With World Class Quality

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

Product Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter

Flow Meter Hire QUICK REFERENCE GUIDE

AUSTRALIA S LARGEST WEIGHBRIDGE MANUFACTURER!

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

MS50 Buoyancy level switch. K-TEK products. Measurement made easy. Features. Typical applications

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

Industrial Solutions. Quality is Our Driving Force. interfaceforce.com

seamless, double walled, made of , option: Hastelloy and other materials Heating jacket (option)

LIQUID CONTROLS. Terminal and Bulk Plant Metering Applications. Application Brochure:

Thinking big. Acting bold.

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

NELES TRUNNION MOUNTED, BALL VALVES, FULL BORE, SERIES X

ASTM A335 Chrome Moly Pipe. Welcome to Sunny Steel Enterprise Ltd. By Mr. Sum Xu

APlus-QMC LLC. Catalog 2017

Tuffy T3 Liquid Level Controls with Electric Switches

L104 PTFE L120 PTFE. Type S Gasket. applications. For use on ASME B 16.5 flanges. May be used for above ground or subsea

KTM METALTITE BALL VALVES FLOATING AND TRUNNION TYPE

X-MET8000. Trust but verify: Ensure product quality with Oxford Instruments latest handheld XRF analyser

Model B. Thermostatic Control Valves. Typical applications

FLUXUS F/G601 and F/G608

Alpha VSRD Multiphase Flowmeter

Tools for Pipe Welding

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

Trust but verify: Ensure product quality at all stages of production

INSULATED JOINTS. Monolithic Joints for Electrically Isolating Pipelines

Transcription:

RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty down to 0.5% Repeatability better than 0.05% Typical measuring ranges between 200 and 8000 kg/min Accurately measure low flow rates down to 130g/min Unique robust torsion driven oscillation system Process connection customization available Approved for use in hazardous areas Stainless steel case Remote and compact transmitter versions available Applications Typical applications include: Terminal Transfer Asphalt/Bitumen and Other High Temperature Fluids Viscous Fluids Barge, Ship, Rail Car and Truck Filling Benefits Torsion oscillator design assures a stable and drift free measurement with excellent signal to noise ratios Resilient to external noise and vibration Insensitive to pipe pressure changes Robust tube wall thickness provides increased operational safety in abrasive applications Corrosion resistant Long sensor life guaranteed due to low mechanical stresses in the meter mechanism No moving parts to wear or fail

RHM80 General Specifications Nominal Max Flow Range: 8000 kg/min (17637 lb/min) Density Range: 5 to 5000 kg/m 3 (0.31 to 312 lb/ft 3 ) Temperature Range: Pressure Ratings: Electrical Connection: Sensor Housing Materials: Enclosure Type: Material of Wetted Parts: Finishes: Certifications and Approvals: Documentation: Proof Testing: Options: Transmitter Range 5 temperature range options cover temperatures from -196 C to 350 C (-320 F to 662 F) Dependent upon material Cable entry M25 x 1.5 (standard) M20 x 1.5, ½" NPT, ¾" NPT (optional) Max cable length to remote RHE transmitter 30m (98 ft). 100m (330ft) with optional high performance cable 1.4301 / 304 stainless steel (standard), 1.4571 / 316Ti stainless steel (optional) Epoxy coated aluminium electrical box (standard), 1.4571 / 316Ti stainless steel (optional) Protection Class IP 65. Optional IP 66 / NEMA 4X Sensors are available in a variety of standard and custom materials to suit a wide range of pressure ratings and chemical compatibility requirements. See the pressure ratings listing in this document for further details ANSI flange finish: AARH 125 to 250 μin, Ra 3.2 to 6.3 μm ATEX approval Zone 0: Ex II 1 G Ex ia IIC T1-T6 Ga ATEX rating Zone 2: Ex II 3 G Ex na IIC T1-T6 Gc CSA USA-Canada, Class I, Div. 1, Groups A, B, C, D PED according to 97/23/EC Module A1 or Module B + C1 (as required by application) All sensors are supplied with a traceable calibration certificate. Optional documentation items available: - Traceable material certificates - Certificates of origin and conformity - Welding - NACE - Quality - Production and manufacturing procedures Other documentation to client requirements available Hydrotest, dye penetrant, x-ray, PMI Enclosure heating matrix for high temperature applications RHE07 RHE08 RHE11 RHE12 Any Rheonik Mass Flow Transmitter model can be combined with an RHM80 sensor to provide an overall mass flow measurement system to suit any requirement. Rheonik Coriolis transmitters are designed for process, industrial and OEM applications. Together they offer a tremendous range of options for system designers and end users alike.

RHM80 Measurement Performance Standard Calibration Flow Rate Uncertainty kg/min lb/min in % of reading 8000 17637 0.20 4000 8818 0.20 1000 2205 0.20 400 882 0.20 200 441 0.50 Uncertainty % Flow Rate kg/min DP (bar) Goldline Calibration* Flow Rate Uncertainty kg/min lb/min in % of reading 6000 13228 0.15 4500 9921 0.15 3000 6614 0.15 1500 3307 0.15 600 1323 0.15 Uncertainty % Flow Rate kg/min DP (bar) Flow Rate Low Flow Calibration* Uncertainty kg/min lb/min in % of reading 8000 17637 0.20 2000 4409 0.20 400 882 0.20 200 441 0.50 130 287 0.60 *Goldline and Low Flow Calibration is not available with all configurations of the RHM80. Please check with factory. Uncertainty % Flow Rate kg/min DP (bar) Mass Flow Calibration Options A 40:1 Standard Calibration 0.5% Uncertainty between 8000 and 200 kg/min B 20:1 Standard Calibration 0.2% Uncertainty between 8000 and 400 kg/min G 10:1 Goldline Calibration 0.15% Uncertainty between 6000 and 600 kg/min 2 Low Flow Calibration 0.2% Uncertainty between 8000 and 400 kg/min, 0.5% between 400 and 200 kg/min, 0.6% between 200 and 130 kg/min Uncertainty of reading (incl. zero drift) stated at reference condition of: H 2 O, 18 24 C (66-6 F), 1-3 bar (15-45 psi) when installed according to field manual Pressure drop indications are based upon H 2 O flowing in a meter with P1 pressure rating For customized calibration range or uncertainty levels, please consult factory Flow Measurement Repeatability Standard ± 0.1% of rate Goldline ± 0.05% of rate Density Measurement Performance (liquids) Standard 2 point calibration ±1% of value Optional 3 point calibration ±0.5% of value Gas density depends upon pressure Temperature Better than ± 1 C

RHM80 Pressure Ratings The maximum pressure (P max ) of a sensor is determined by its lowest rated part. The lowest rated part is either the measuring tube (P max indicated below) or the process connection (for P max see published standards or manufacturer information). RHM80 Measurement Tube Pressure Ratings Pressure Code Material Code Material P1 (std.) P1 M1 (std.) M3 P1 10* P1 62* P2 M1 (std.) P2 10* P2 62* 1.4571 (316Ti) UNS S31635 2.4602 (Alloy C22) UNS N06022 1.4410 (Super Duplex) UNS S32750 1.4462 (Duplex) UNS S31803 1.4571 (316Ti) UNS S31635 1.4462 (Duplex) UNS S31803 1.4410 (Super Duplex) UNS S32750 p max bar psi C F 104 1508 @ 50 122 93 1349 @ 120 248 80 1160 @ 210 410 67 972 @ 350 662 141 2045 @ 50 122 125 1813 @ 120 248 106 1537 @ 210 410 89 1291 @ 350 662 248 3597 @ 50 122 218 3162 @ 120 248 197 2857 @ 210 410 198 2872 @ 50 122 174 2524 @ 120 248 152 2205 @ 210 410 165 2393 @ 50 122 148 2147 @ 120 248 127 1842 @ 210 410 107 1552 @ 350 662 272 3945 @ 50 122 238 3452 @ 120 248 209 3031 @ 210 410 341 4946 @ 50 122 299 4337 @ 120 248 270 3916 @ 210 410 *Only with T1, TA, T2 temperature range (note min. temp. is -40 C). Other Materials Additional/custom wetted materials (Inconel, Monel, 304 stainless steel, others) may be possible for chemical compatibility, lower pressure drop, abrasion allowance, other application specific requirements. Contact factory with specification for assessment and availability.

RHM80 Mechanical Construction PF0: Seal-less parallel measuring tube construction with flange connections For customization of face to face length and/or special fittings other than the ones listed on this page, please consult factory. Note that larger diameter flange process connections are always possible. Process Connection Face to face length (L) Order Code mm in ANSI 6" 150# RF 900 35.43 A1 ANSI 6" 300# RF 900 35.43 A2 ANSI 6" 600# RF* 900 35.43 A3 ANSI 6" 900# RF* 900 35.43 A7 ANSI 6" 1500# RF* 900 35.43 A9 ANSI 8" 300# RF 900 35.43 A6 ANSI 10" 300# RF 900 35.43 A8 ANSI 6" 900# RTJ* 900 35.43 R1 ANSI 6" 1500# RTJ* 900 35.43 R2 ANSI 6" 2500# RTJ* 900 35.43 R3 DIN DN150/PN16 900 35.43 D1 DIN DN150/PN40 900 35.43 D2 DIN DN150/PN100* 900 35.43 D3 DIN DN200/PN16 900 35.43 D8 JIS RF 10k 150A (6") 900 35.43 J1 JIS RF 20k 150A (6") 900 35.43 J2 A2 = 1320 mm (51.97 in) B2 = 403 mm (15.87 in) H1 = 1505 mm (59.25 in) H2 = 1775 mm (69.88 in) W = 150 mm (5.91 in) Electrical box: std. = 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in), RHE16 compact = 120 x 120 x 80 mm (4.72 x 4.72 x 3.15 in) *This flange selection will reduce maximum allowable measurement tube pressure rating by a factor of 0.73. Weights and Shipping Dimensions Typical weight with 6" 150# flanges: approx. 380 kg (838 lb). RHM80 meters ship in a wooden crate (to ISPM 15). Typical dimensions approx. 220 x 160 x 90 cm (87 x 63 x 36 in). Typical gross shipping weight example: RHM80 with 4" 150# flanges c/w RHE08 transmitter approx. 550 kg (1213 lb).

RHM80 Part Number Code Temperature Range T1-20 C to +120 C (-4 to +248 F) (std.) TA -45 C to +120 C (-49 to +248 F) T2-45 C to +210 C (-49 to +410 F) T3-196 C to +50 C (-320 to +122 F) T4 0 C to +350 C (+32 to +662 F), max operating temp. 280 C (536 F) P max of Measuring Loops (see pressure rating page) P1 P max depends upon material P2 P max depends upon material PY P max = 299 bar (4337 psi) @ 120 C (248 F) (10 material) Material of Wetted Parts M1 1.4571 (316Ti) M3 2.4602 (Alloy C22) 62 1.4462 (Duplex) 10 1.4410 (Super Duplex) Process Connection See mechanical construction page for available connections and codes Options Codes See options listing for specific codes Terminal Box Selection 9 Remote transmitter cable termination box (std.) C Enclosure for compact mount RHE16 transmitter Hazardous Area Certifications N Without Ex approval A ATEX approval Zone 0: Ex II 1 G Ex ia IIC T1-T6 Ga 2 ATEX rating Zone 2: Ex II 3 G Ex na IIC T1-T6 Gc C CSA approvals USA-Canada Class I, Div. 1, Gr,. A, B, C, D Pressure Design Compliance NN No design compliance selected A1 PED to module A1 [Europe] BC PED to module B+C1 [Europe] CA CRN (Alberta Province) [Canada] CR CRN (All other Provinces) [Canada] Mass Flow Calibration Selection See performance page for code options Density Calibration Selection D 1% Accuracy (std.) S 0.5% Accuracy RHM80 PF0 N Options H1 Hot oil/steam heating matrix for housing, DN25 PN40 SH Housing in 316Ti stainless steel H2 Hot oil/steam heating matrix for housing, 1" ANSI 150 RF DY Dye penetrant inspection H3 Hot oil/steam heating matrix for housing, 1" ANSI 300 RF XR X-ray test P2 Housing purge for dry gas ½" NPT (2 pcs) O Oil/grease free cleaning