PHOSPHORUS AND ALGAE REMOVED FROM WAIHI FACULTATIVE POND DISCHARGE

Similar documents
CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES DEPARTMENT WASTEWATER TREATMENT OPERATIONS GREENWAY POLLUTION CONTROL CENTRE 2013 ANNUAL REPORT

Lagoons Operation and Management in New Brunswick

WEFTEC.06. **Cobb County Water System, Marietta, Georgia

Lowering The Total Cost Of Operation

This document can be made available in other accessible formats as soon as practicable and upon request. Staff Report. Infrastructure & Public Works

Alexandria Sewage Lagoon Treatment Facility Municipal Class C Environmental Assessment Public Information Centre #2 Welcome!

Startup and Performance of the World s first Large Scale Primary Dissolved Air Floatation Clarifier ABSTRACT KEYWORDS INTRODUCTION

Copies: Mark Hildebrand (NCA) ARCADIS Project No.: April 10, Task A 3100

Wastewater Treatment Processes

OPERATION OF AN STP FOR RECYCLED WATER PRODUCTION PLANT. Iain Fairbairn. Iain Fairbairn, Plant Manager, Sydney Water

WASTEWATER TREATMENT SYSTEM

Sewage Treatment Plant Performance Report

Evaluation of Stockton Deep Water Ship Channel Water Quality Model Simulation of 2001 Conditions: Loading Estimates and Model Sensitivity

final report Water quality improvement strategy for a processing site

WWETCO FlexFilter and Bio-FlexFilter

Costs and Benefits of Requiring On-Site Wastewater System Treatment Standards Greater Than Nationally Recognized Standards

Long-Term Volunteer Lake Monitoring in the Upper Woonasquatucket Watershed

Recovering a Failed Sand Filter Wastewater Treatment System

Pilot Testing Reveals Alternative Methods to Meet Wisconsin s Low Level Phosphorus Limits

A Hybrid Constructed Wetland System for Decentralized Wastewater Treatment

DEALING WITH STRATIFICATION WITHIN A WATER SUPPLY RESERVOIR. Chris Perks. Central Highlands Water

Taylor Creek Treatment Plant. Metropolitan Sewer District of Greater Cincinnati

UV DISINFECTION OF LOW TRANSMITTANCE PHARMACEUTICAL WASTEWATER

Wastewater Treatment Processes

Decentralized WW Management: Issues for Small-Scale WWTPs. Mike Stephens MWEA Local Sections Committee Frankenmuth, MI

Case Study. BiOWiSH Aqua. Biological Help for the Human Race. Municipal Wastewater Bathurst Waste Water Treatment Works Australia.

Indian Health Service Sanitation Facilities Construction Program Wastewater Lagoon Operation & Maintenance

2014 ASSINIBOINE RIVER MONITORING REPORT

EUTROPHICATION. Student Lab Workbook

A H. Marcela Velázquez-Carrillo Consultant to Mountain Systems Inc. on the application of Proficy for Water Treatment

Proposal by Russia to delete hot sub-spot Hot sub-spot name South-West Wastewater Treatment Plant

Operations Report. September 10, 2015

Best practice in monitoring process, operation and maintenance of wastewater treatment plants 12 September 2011, Bucharest

CEDAR CREEK Wastewater Treatment Facility

Combined Sewer Overflows July 2012-December 2013

1. The Activity. 2. Background. 3. Wastewater Volumes and Composition. Attachment 2 to Report Page 1 of 10

An Introduction to Chemically Enhanced Primary Treatment

Use of Biowin for Process Troubleshooting / Design for a Unique Wastewater

Integrated real-time SRT and aeration control in the city of Grand Rapids

Environmental Protection Licence 2688

Dealing with Unexpected Wastewater Treatment Plant Disruptions. February 16, 2017

Presented By: Kevin Bossy. The Supplier Perspective: Accelerating the Adoption of Innovative Solutions

WASTEWATER TREATMENT. Nelson Environmental Inc. Nelson Environmental Inc.

CITY OF OXFORD WASTEWATER TREATMENT FACILITY ANNUAL PERFORMANCE REPORT FOR THE CALENDAR YEAR OF 2012

SEWAGE SYSTEM SOLUTIONS Current Issues in Ontario & Case Studies of Innovative Approaches to Remedy Failing Systems

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

Aquaculture Effluents and the Environment. CS Tucker, Mississippi State University

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

AMMONIA REMOVAL USING MLE PROCESS EXPERIENCES AT BALLARAT NORTH. David Reyne. Central Highlands Water Authority

INCHEM Tokyo Current Status and Implementation Approach for Industrial Zones Wastewater Management In Yangon Region

Ballasted Activated Sludge Demonstration Study SEPTEMBER 30, 2016

Causes and Possible Corrections for Nuisance Algae Conditions in Huron River Lakes: Summary Findings from 2003, 2004, and Prof John T.

Gulf Coast Testing, LLC

Innovative Use of Dissolved Air Flotation with Biosorption as Primary Treatment to Approach Energy Neutrality in WWTPs

AquaPASS. Aqua MixAir System. Phase Separator. System Features and Advantages. Anaerobic. Staged Aeration. Pre-Anoxic.

Boy Lake CASS COUNTY

East Coast P Removal Technology Performance Summary

WASTEWATER TREATMENT

JEDDAH INDUSTRIAL CITY

Benlouali Hajar*, Redouane Choukr-Allah, Harrouni Moulay Cherif, Aziz Hirich, Mohamed Fallah

Unit Treatment Processes in Water and Wastewater Engineering

International Joint Commission Water & Wastewater Treatment Best Management Practices Forum Monday, March 26, 2012 Wayne State University, Detroit MI

Wastewater Treatment Technology and Applications in Industrial Facilities

NPDES WASTEWATER DISCHARGE PERMIT EVALUATION

A large pumped storage scheme for seasonal reliability of national power supply?

ULTRAVIOLET DISINFECTION FOR STORMWATER TREATMENT IN COASTAL CAROLINAS

Sanitary Sewer Systems. Sewage Collection System. Types of Sewage 10/12/2016. General Overview

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

STREAMING CURRENT MONITOR FOR COAGULANT OPTIMIZATION IN WATER TREATMENT PLANTS - LAP EXPERIENCE

Recycling of Food Processing Wastewater to Potable Water Standards

Dr Martin Peter *, Joachim Scholz & Victor Ferre. Contents

Stormwater Treatment Wetlands

Case Study: City of Brantford. Controlling Industrial Discharges to Improve Plant Performance

Application of the AGF (Anoxic Gas Flotation) Process

Case Study. BiOWiSH Aqua has Positive Long-Term Effects. Biological Help for the Human Race

RE: Year-End Report Woodstock Wastewater Treatment Plant (WWTP), 2012

. ARUSHA URBAN WATER SUPPLY AND SANITATION AUTHORITY (AUWSA)

OPERATORS PERSPECTIVE : OPTIMISATION OF A NEW PACKAGE WATER TREATMENT PLANT. Melina Entwistle. North East Water Authority

Aerofloat specialises in the treatment of greywater and industrial wastewater from a range of industries.

The OWASA UNC Reclaimed Water System: A Progress Review

OVERCOMING CHLORAMINATION OPERATIONAL PROBLEMS AT WILLOW GROVE WATER TREATMENT PLANT. Brendan Holt. Gippsland Water Authority

Water Quality Permitting Program Monitoring Matrix 1,2,3

Water Specialists for the Food & Beverage Sector creating value in water through innovation, creativity and expertise. ovivowater.

STUDY FOR INDUSTRIAL WASTEWATER TREATMENT USING SOME COAGULANTS

Communal Sewage Inspection Report

Performance of Sewage Oxidation Pond in USM Engineering Campus

A NEW METHOD FOR EVALUATING PRIMARY CLARIFIERS Alex Ekster and Cristina Pena San Jose/Santa Clara Water Pollution Control Plant City of San Jose

EVALUATING ALTERNATIVES FOR DISPOSING OF WATER PLANT SOLIDS INTO A WASTEWATER PLANT

TDS AND SLUDGE GENERATION IMPACTS FROM USE OF CHEMICALS IN WASTEWATER TREATMENT

Guide to Inclined Plate Settlers

Environmental Dynamics International

Water Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water

Hydrology and Water Quality. Water. Water 9/13/2016. Molecular Water a great solvent. Molecular Water

Results of Water Quality Measurements in Messer Pond Bob Crane, Messer Pond Protective Association (MPPA) Board

Development of Integrated Filtration System for Water Treatment and Wastewater Reclamation in Developing Countries

Water Quality Study In the Streams of Flint Creek and Flint River Watersheds For TMDL Development

Effects of high-strength faecal sludge in wastewater stabilization ponds: Port-au-Prince, Haiti

Information Request 11

GROUNDWATER MONITORING AT FORMER FCC SITE, MAPUA FEBRUARY 2010 SAMPLING UPDATE

Transcription:

PHOSPHORUS AND ALGAE REMOVED FROM WAIHI FACULTATIVE POND DISCHARGE K.M. Holyoake 1, K.V. Kotze 1, P. Patel 2 1 Armatec Environmental Ltd, 2 Hauraki District Council Paper presented at the NZ Water and Wastes Association Inc. Conference at Christchurch, New Zealand, October 2006 ABSTRACT A new tertiary treatment plant commissioned in July 2005 is removing phosphorus and algae from the discharge of the facultative ponds that treat the wastewater from the town of Waihi. The phosphorus is chemically precipitated out using alum and then floated off together with algae and other suspended solids. After removal of phosphorus, algae and suspended solids, the treated water passes through an ultra-violet disinfection stage and then via a rock cascade to the Ohinemuri River. The tertiary treatment plant is capable of reducing the TP (total phosphorus) from around 3 mg/l to less than 0.1 mg/l and the suspended solids concentrations from over 150 mg/l to less than 10 mg/l. The plant operating results are significantly better than the resource consent requirements of 1.4 mg/l for TP and 35 mg/l for suspended solids. The plant operates on a timed basis with throughput set to achieve the desired water level reduction in the facultative ponds over the running period of the cycle. There has been a significant drop in the concentration of both the DRP (dissolved reactive phosphorus) and the TP in the Ohinemuri River downstream of the plant since the plant was commissioned. KEYWORDS Phosphorus, algae, tertiary treatment, facultative ponds 1. NEW TERTIARY TREATMENT PLANT The new resource consent for the discharge of the Waihi Sewage Treatment Plant requires the Hauraki District Council to remove phosphorus, suspended solids and E coli (Environment Waikato, 2002) are in Table 1. TABLE 1: Conditions of Resource Consent Parameter Conditions Median (g/m 3 ) Total Phosphorus 1 November to 30 April & when 1.4 Ohinemuri River < 10.1 cusecs Total Phosphorus 1 May to 31 October except when Ohinemuri 5.7 River < 10.1 cusecs BOD At all times 20 Suspended Solids At all times 35 Ammonia Nitrogen At all times 4.0 E coli Ohinemuri River < 10.1 cusecs 126 E coli Ohinemuri River > 10.1 cusecs 5000 (max) Phosphorus removal is required because Environment Waikato had identified (Beca Steven, 1995) that the Waihi discharge contributes more than 65% of the phosphorus measured in the Ohinemuri River. This river is popular for swimming, fishing and other activities as it flows through the Karangahake Gorge. There have been algae blooms in the Ohinemuri River over summer periods, with extreme events literally turning the river shades of green and red. A new tertiary treatment plant commissioned in July 2005 is removing phosphorus and algae together with other suspended solids from the Waihi discharge. After removal of phosphorus, algae and suspended solids, the treated water passes through an ultra-violet disinfection stage and then via a rock cascade to the Ohinemuri River. The facultative ponds still remain the main treatment engine for CBOD 5 (carbonaceous biochemical oxygen demand) reduction achieving an exit CBOD 5 of from 25 to 50 g/m 3.

2. PHOSPHORUS & ALGAE REMOVAL In this chemical treatment process, alum is used to chemically precipitate DRP (dissolved reactive phosphorus). At the same time, the alum coagulates the precipitated phosphorus, algae and suspended solids, and with the addition of a polymer and a surfactant, flocs are established suitable for separation by flotation. As the precipitation and coagulation are ph dependent, acid addition is used to firstly bring the wastewater to the correct ph. The quantity of acid varies throughout the year and throughout each day as a result of the constantly changing ph in the facultative ponds. A diurnal ph range of 6.5 to 9.5 has been recorded. Alkali is added last to return the ph to near neutral for discharge to the Ohinemuri River. The flocculated solids are separated from the treated wastewater in a hybrid combination induced and dissolved air flotation tank. Finely dispersed air bubbles are brought into contact with the chemically conditioned slurry where particulate-bubble attachment occurs. The particle-laden bubbles float to the surface of the flotation tank from where they are intermittently scraped off and removed. Until a suitable disposal option is found the solids are returned to the facultative ponds. The phosphorus and algae removal plant is designed for a typical throughput of 167 cubic metres per hour, and has a maximum throughput of about 200 cubic metres per hour. Whilst the chemistry of phosphorous removal is well established, this tertiary treatment plant is a first of its kind in New Zealand. The small footprint and high phosphorus and suspended solids removal efficiencies were the key attributes that led to the choice of this plant. FIG 1: Flowchart of plant and chemical additions

3. PLANT TREATMENT RESULTS Independent laboratory analyses (R.J. Hill Laboratories, 2005,06) have been used to monitor plant performance. Regular sampling for analysis by this independent laboratory began in April 2006. TABLE 2: Independent Laboratory Analyses of Raw and Treated Water Date TSS (g/m3) DRP (g/m3) Total P (g/m3) CBOD5 (g/m3) E-coli (/100ml) Raw Treated Raw Treated Raw Treated Raw Treated Raw Treated 27-Jul-05 6 < 0.004 0.278 2 < 1 28-Jul-05 10 < 0.004 0.327 4 3 29-Jul-05 < 0.004 0.118 2 < 10 21-Sep-05 112 3.83 12-Oct-05 126 5 1.4 < 0.004 2.75 0.074 26-Nov-05 92 9 1.59 < 0.004 2.76 0.108 27 1 6-Apr-06 178 5 4.24 0.094 22 < 1 < 1 19-Apr-06 251 4 5.66 0.086 33 < 1 12400 41 4-May-06 77 < 3 1.86 < 0.004 3.04 0.054 717 17 18-May-06 58 10 1.73 < 0.004 2.43 0.148 24 1 1-Jun-06 62 8 1.9 0.005 2.83 0.155 22 1 29-Jun-06 94 10 1.69 < 0.004 3.1 0.207 37 1 19-Jul-06 112 < 3 2.09 0.005 3.65 0.137 53 1 The E-coli results are from samples taken after the UV plant, but the UV plant may or may not have been operating. Results have found that the phosphorus and algae removal plant is reducing the E-coli to less than the resource consent conditions without the UV plant operating. All the results in Table 2 for the treated wastewater are significantly better than the resource consent requirements of 1.4 mg/l for total phosphorus and 35 mg/l for suspended solids respectively. 4. PLANT OPERATION The plant operates on a timed basis usually running for 5 days per week to suit incoming flows and operator schedules. This allows the operator to have the plant off during weekends and parts of holiday periods minimising operator labour cost. The plant throughputs for the first seven months of 2006 are given in Fig 2. Frequent wet weather events during the months of April and May 2006 required the plant to be run at higher throughputs for longer periods. The average inflow to the plant is 1,000 cubic metres per day, increasing to 3,000 cubic metres per day in wet weather. A total of 342,545 cubic metres of wastewater were treated in the first seven months of 2006. The plant is fully automated with operator supervision at start-up and shutdown. Thus the operator is able to attend to the running of other plants in the area as well. The plant operator s attendance is for between 1 and 3 hours per day, depending on the maintenance regime to be followed. During the stand-down period of the plant s operating cycle, the water levels in the facultative ponds are allowed to rise to provide temporary storage. Plant throughput is set to achieve the desired water level reduction in the facultative ponds over the running period of the cycle. This flexible plant operation also allows for extended shutdown periods for maintenance on the plant and the facultative pond structures. Current chemical costs in the first half of 2006 were $120 to $140 per thousand cubic metres of wastewater treated. This includes the additional acid and alkali required for ph adjustment due to the low alkalinity of the wastewater. Electrical consumption for the plant excluding the UV plant is approximately 190 kw/hrs per thousand cubic metres of wastewater treated, with the majority of this being UV plant consumption. In addition there is the 40 kw supply pump to pump the wastewater from the facultative ponds to the elevated site of the tertiary treatment plant.

FIG 2: Monthly Plant Throughputs - January to July 2006 5. PLANT RELIABILITY Power fluctuations have caused the most disruption to the operation of the plant. The plant is located at the end of a power distribution network so is always the first to be affected by supply irregularities. A series of power cuts posed a number of challenges not long after the plant was commissioned. A number of changes had to be made to the plant defaults and logic to take account of unplanned power failure events, in order to make restarts straightforward. In January 2006 a swan flew into the supply power line to the plant, and the resulting power surge knocked out the UPS and caused other electrical damage in the plant. This resulted in a number of plant shutdowns for no apparent reason. It was only after the instrumentation voltage levels were found to be fluctuating that progress was made in rectifying these issues. Delays in establishing a reliable and fast remote access to the plant PLC caused difficulties and slow resolution of plant shutdowns. The planned radio link was never able to achieve the required speed and reliability. A wireless broadband internet connection was finally installed and this has greatly improved the speed of troubleshooting at the plant. 6. PHOSPHORUS CONCENTRATIONS IN OHINEMURI RIVER There has been a significant drop in the concentration of both the DRP and the TP in the Ohinemuri River downstream of the plant since the plant was commissioned (Fig 3). The student-t analysis of these results is less than 0.1% and 0.8% respectively for the DRP and TP respectively indicating that the figures for the DRP and TP before and after the treatment plant was operational are different data sets. There has also been a drop in the mass flow of both the DRP and the TP (Fig 4). The student-t analysis of these results is 1.6% and 32.3% respectively indicating that the DRP result is statistically significant whereas the TP is not. As more monthly results come to hand, the latter is decreasing and becoming more statistically significant. These results are evidence that the plant is achieving the desired results of reducing the phosphorus contributed to the Ohinemuri River by the Waihi wastewater treatment plant discharge.

FIG 3: DRP and TP Concentrations in Ohinemuri River Before and after Treatment Plant Operational FIG 4: Ohinemuri River Mass Flows Before and after Treatment Plant Operational

7. DISCUSSION When the phosphorus and algae removal plant was originally conceived, it was anticipated that the plant would only operate from the beginning of November through to the end of April each summer. It was anticipated that the river flows would be in excess of 10.1 cubic metres per second for most of the winter months, and that the level of suspended solids in the discharge would be low enough to meet the resource consent conditions during this period. Neither of these eventuated. The Ohinemuri River flows are less than 10.1 cubic metres per second in winter months for nearly 30% of the time. The suspended solids content of the discharge from the facultative ponds is always in excess of 35 mg/l. Therefore the discharge from the facultative ponds is required to be run through the tertiary treatment plant at all times. The plant is not able to remove suspended solids only without additions of alum, polymer and surfactant. This has meant that the plant is treating the water to a higher degree than is required by the resource consent, but on the other hand demonstrates that this level of treatment is able to be achieved with the use of this technology. The plant is designed primarily to remove DRP and suspended solids. However, it is also removing over 90% of other forms of phosphorus, over 95% of CBOD 5, 60% to 90% of total nitrogen, and over 90% of the E-coli. Whilst these levels of removals are not required by the resource consent conditions, they can only be positive for the Ohinemuri River that has been described as a poor quality aquatic habitat (Beca Steven, 1995). The phosphorus and algae removal plant has greatly reduced the load on the UV disinfection plant. E-coli measured in the inlet to the phosphorus and algae removal plant have been in the range of 500 to 3000 MPN/100ml, and in the outlet of the phosphorus and algae removal plant in the range of 7 to 20 MPN/100 ml. The treated water has a UV transmittance of 70% to 80%, and this has resulted in a substantially reduced load and power consumption in the UV disinfection plant. 8. CONCLUSION The tertiary treatment plant is removing phosphorus and algae from the discharge of the Waihi Sewage Treatment facultative ponds. The treated discharge is meeting the conditions of the resource consent for phosphorus, suspended solids and E-coli. The contribution of phosphorus to the Ohinemuri River by the Waihi wastewater treatment plant has significantly reduced. ACKNOWLEDGEMENTS The help and support of the Hauraki District Council in preparing this paper is gratefully acknowledged. Environment Waikato s provision of data from the Ohinemuri River Queens Head Station is acknowledged. REFERENCES Beca Steven, 1995. Assessment of Environmental Effects Waihi Effluent Disposal. Prepared for the Hauraki District Council. Environment Waikato, 2002. Resource Consent (106612) Discharge Permit to Discharge Water. For the Hauraki District Council. R.J. Hill Laboratory, 2005/06. Analyses of Samples from Waihi Wastewater Treatment Plant.