Acutherm was spec d here. Building Automation Guide for Therma-Fuser Systems

Similar documents
Therma-Fuser Systems. Energy Modeling Guide for Therma-Fuser systems. Acutherm was spec d here

THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS

Element D Services Heating, Ventilating, and Air Conditioning

Persistence Tracking in a Retro-commissioning Program

Building Automation Systems

Use of Building Automation Systems for (Retro)Commissioning

NEBBinar: Managing Building Performance through Commissioning. March 28, 2013

Optimizing Buildings Using Analytics and Engineering Expertise

High Technology Energy Savings Guide

EADQUARTERS. Thesis Revised Proposal. Stephanie Kunkel Mechanical Option

Robert E. McMains Date Robert E. McMains Date

Zoned Comfort Control

V entilation control using carbon dioxide

City of Fort Collins Building Automation Systems Enhances Savings and Commissioning Efficiency Works Training

LABORATORY CONTROL SOLUTIONS FROM TSI

SGM Engineering, Inc.

Energy Efficiency. best in class

Trane eflex. For Ton Light Commercial Applications

Building Controls Strategies Conference. Retro-Commissioning with BAS Overview. 10 March Steve Brown, CAP ESD Controls Team Leader

Case Study for Fortune 500 Telecom: Retrofitting Pneumatic Controls for Energy Efficiency

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE

DISPLACEMENT VENTILATION

Beyond Advanced Lighting Controls: Reaching Net Zero with Integrated Building Controls

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies.

Knowledge is Power. Belimo Energy Valve

Voyager kw rooftop units Plug and Play comfort in commercial applications


Chilled Water System Optimization

UC Berkeley Indoor Environmental Quality (IEQ)

Underf loor For Schools

Innotech is a registered Trademark of Mass Electronics Pty Ltd Copyright 2013 Mass Electronics Pty Ltd

The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, 2009 All Rights Reserved

Retro-Commissioning for Existing Facilities

THE KEMPER BUILDING 1 EAST WACKER DRIVE PHIL KEUHN SIEBEN ENERGY ASSOCIATES

Rebel commercial packaged rooftop systems

2B. Performance Advantages of Alerton BACnet. 1. Alerton Overview

Advantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure

Retro-Commissioning in Hospitals

Optimizing BAS Information for Operator Effectiveness and Optimal Control

Mechanical Product Overview

Trane IntelliPak 2. Rooftop Comfort System

Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE

TEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

Energy Reduction Strategy Through 2020

Chilled Beams. The new system of choice?

Controls Master Planning Process leads to Campus-Wide BAS Upgrade. 11 February 2015

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Fundamentals of Test & Balance for Engineers, Cx & Energy Providers Course Number: CXENERGY1619

Introduction of the latest Technology of Energy Conservation

How LEED & The Retro-Commissioning Credits Produce Energy Savings. James Vallort Vice President Environmental Systems Design, Inc.

Mission Critical Commissioning for Healthcare Facilities

Knowledge is Power Belimo Energy Valve CHW DELTA T MITIGATION STUDY AHR Expo Innovation Award Winner in the Category of Building Automation

The impact of Building Automation on Energy Efficiency. Siemens with DESIGO and Synco best in class. Siemens AG, plc, All Rights Reserved

Doubling Down on Not Balancing Variable Flow Hydronic Systems BY STEVEN T. TAYLOR, P.E., FELLOW ASHRAE

Ehsan Soltani. Date of Birth: 1 Sep, 1980 Nationality: Iranian Marital Status: Married Mobile :(+98)

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.40

5/7/2012. Agenda. What is High Performance? Ensuring a Successful Transition to Sustainable, High-Performance Operations

CARRIER PRODUCTS AND LEED CERTIFICATION

Energy modeling in IDA ICE according to ASHRAE , app. G

Leading Techniques for Energy Savings in Colleges and Universities

Steam Load Shed Events

Calculation of AC System Performance Without Gauges

Integration of Controls

Mechanical-Electrical Technology MECHANICAL-ELECTRICAL TECHNOLOGY Sacramento City College Catalog

Centre for Addiction and Mental Health Queen Street Campus Energy Conservation and Demand Management Plan

Universal Translator 3: A free software tool to support your data processing needs

Wood Products Energy Savings Guide

ENERGY CALCULATOR & MODELLING PROTOCOL

Air Cooled Packaged Air Conditioning

Industrial Retrofit Guide. Superior Solutions for Industrial Heating and Ventilating

MBCx: The Next Wave of Energy Savings in Utility Incentive Programs

RETRO-COMMISSIONING: AN OWNER S LOOK AT THE TRUE COSTS AND RETURN ON INVESTMENT. Adam Renzi, PE

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings

Ecodesign FROM REGULATION 1253 & 1254/2014. For Residential And Non-Residential Ventilation Units

Recommissioning Energy Savings Persistence

OAKDALE CHILLED WATER PLANT CAPACITY UPGRADES UI PROJECT INSTALL CHILLERS SECTION COMMISSIONING

Features. Low Flow Dual Duct VAV/CV with QVM. Application Data Sheet

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.

Ventilation. Demand-controlled ventilation (DCV) Demand-Controlled. With ASHRAE Standard Based

NEWMOA June 30, Fran Boucher LEED AP, Certified Energy Manager Senior Energy Engineer

Energy Conservation at the University of Pittsburgh - FY2014 and Beyond

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Intelligent Variable Air. An EarthWise System from Trane for packaged DX applications

Texas Hospital. Central Plant Redesign. Central Utility Plant SECOND PLACE HEALTH CARE FACILITIES, EXISTING 2013 ASHRAE TECHNOLOGY AWARD CASE STUDIES

To efficiency and beyond

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

DTS & ENERGY MODELLING PROTOCOL GUIDE Version 1.0

EnOcean. Green. Smart. Wireless. Troy Davis

Reflow Oven. USA HEADQUARTERS:

Variable Frequency Drives

COMMERCIAL LOAD ESTIMATING. Load Estimating Level 3: Block and Zone Loads. Technical Development Program

AHU Models Using Whole Building Cooling and Heating Energy Consumption Data

22 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

KCTCS Using Agency Project Requirements for Building Automation Systems

Agenda. Understanding the three basic piping systems. Low DeltaT Syndrome causes, effects, and solutions Design & Control Considerations (VPF)

PRODUCT BROCHURE. Fixed Helical Swirl Diffuser HSC-FD HSC-FD : smartemp.com

Energy efficiency in the Industry Istanbul Torsten Szypulski. Controlesta RCO

30 DIGITAL SERIES CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Application of Advanced Energy Technologies

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Transcription:

Building Automation Guide for Therma-Fuser Systems Acutherm was spec d here

BUILDING AUTOMATION OPTIONS FOR THERMA-FUSER SYSTEMS As energy costs continue to rise, the management of energy while balancing tenant comfort and operational costs is a significant challenge for commercial building Owners and Managers. A Building Automation System (BAS) is an option that provides monitoring of entire building systems with single source control and troubleshooting. Acutherm s Therma-Fuser VAV System is designed to work cooperatively with the wide range of BAS options available. Whether you're looking for simple individual temperature control, requiring no energy for operation, or full-scale networking for system scheduling, monitoring, reporting, troubleshooting and more, this guide will help you determine what is best for your building needs and budget. Six basic options are compared using the quick chart on the following page, then each option is described in more detail throughout the guide. A Pressure Independence Module (PIM) is also described. Option 1: Therma-Fuser stand alone diffusers This simple configuration provides the comfort and energy savings of individual temperature control with easy adaptibility to office changes, no maintenance VAV terminals and low installation cost due to no diffuser wiring. The BAS monitors and controls only the parts of the system that require periodic maintenance. Option 2: Therma-Fuser stand alone diffusers with Room Temperature Sensors Monitor room air temperatures with the BAS. The BAS can read an analog room temperature signal from a sensor installed in each diffuser. Option 3: Therma-Fuser stand alone diffusers with Wall Adjusters Adjust room temperature set point with the BAS. The BAS can read and reset the room temperature setpoint of each diffuser using analog signals from an Acutherm Wall Adjuster. The Wall Adjuster may be installed on the diffuser or on the wall and may be either wireless or wired to the diffuser. Option 4: Therma-Fuser stand alone diffusers with Room Temperature Sensors and Wall Adjusters A combination of Options 2 and 3, this option monitors room air temperatures and adjusts the setpoint with the BAS. The BAS can read an analog room temperature signal from a sensor installed in each diffuser and can read and reset the room temperature setpoint of each diffuser using analog signals from an Acutherm Wall Adjuster. Option 5: Combination of Therma-Fuser stand alone diffusers with Therma-Fuser DDC interoperable diffusers This option offers complete BAS digital input and output on selected diffusers and the simplicity of no wiring to the others. Key spaces are monitored and controlled by the BAS. Other spaces have the benefit of simplicity and low installation cost due to no diffuser wiring. Option 6: Therma-Fuser DDC Interoperable diffusers This option offers complete BAS digital input and output. Each diffuser has the ability to supply room temperature, airflow and supply air temperature and receive signals for room temperature setpoint, minimum airflow setpoint, maximum airflow setpoint, override open, override closed, CO2 override and more. Digital signals can be either BACnet or LonWorks.

QUICK CHART FOR THERMA-FUSER SYSTEM BUILDING AUTOMATION OPTIONS Ë Comfort - Individual temperature control air distribution saving system Adaptable system 1 1 1 1 Ë Comfort - Superior Ë Energy - Energy Ë Sustainability - Ë Sustainability - No diffuser maintenance 1 Ë Simplicity - No diffuser wiring Ë Simplicity - BAS only monitors parts of system requiring periodic maintenance Ë BAS monitors room air temperature 2,4 Ë BAS monitors and adjusts room 3,4 temperature setpoints Ë BAS monitors diffuser supply air temperature Ë BAS monitors diffuser supply air volume Option 1 Option 2 Therma-Fuser stand alone diffusers 4 4 Ë Other BAS functions (see description) 4 Ë Installed cost $ $ $ $ $ $ $ $ $ $ $ $ $ $ $ Option 3 Therma-Fuser stand alone diffusers Ë Room s Option 4 Therma-Fuser stand alone diffusers ËWall Adjusters Option 5 Therma-Fuser stand alone diffusers ËRoom Temperature Sensors and Wall Adjusters Combination of Therma-Fuser stand alone diffusers ËTherma-Fuser DDC interoperable diffusers Option 6 Therma-Fuser DDC interoperable diffusers NOTES: 1. 10-year warranty on Therma-Fuser stand alone diffusers. (Not applicable to diffuser options and accessories.) 2. Available on Therma-Fuser stand alone diffusers with options 2 and 4. 3. Available on Therma-Fuser stand alone diffusers with options 3 and 4. 4. Only on Therma-Fuser DDC diffusers. 3

Option 1: Therma-Fuser stand alone diffusers Achieve all the benefits of Therma-Fuser VAV and only use the BAS to monitor the parts of the system that need periodic maintenance. This simple configuration provides the comfort and energy savings of individual temperature control, easy adaptability to office changes, and no maintenance VAV terminals along with simplicity and low installation cost due to no diffuser wiring. The BAS monitors and controls only the portions of the VAV system requiring maintenance including the fan, VSD, coils and filters plus other HVAC equipment such as the chiller, boiler, pumps, cooling tower, etc... Diffusers Ë Comfort - Individual temperature control Ë Comfort - Superior air distribution Ë Energy - Energy saving system Ë Sustainability - Adaptable system Ë Sustainability - No diffuser maintenance 1 Ë Simplicity - No diffuser wiring Ë Simplicity - BAS only monitors parts of system requiring periodic maintenance NOTES: 1. 10-year warranty on Therma-Fuser stand alone diffusers. (Not applicable to diffuser options and accessories.) Occupancy Schedule Emergency Override Discharge Air Cooling Setpoint Discharge Air Heating Setpoint Minimum Outdoor Air Setpoint Discharge Air Temperature Static Pressure Mode Chilled Water Temperature Hot Water Temperature Supply Fan Capacity Exhaust Fan Capacity Return Air Capacity Economizer Enabled Outdoor Air Temperature Outdoor Air Damper Position Outdoor Airflow Return Air Temperature Mixed Air Temperature Space Temperature Filter Differential Pressure Text in italics are VAV system possibilities. BAS inputs and outputs are available from other HVAC equipment such as the chiller, boiler, pumps, cooling tower, etc... 4 BUILDING AUTOMATION OPTIONS FOR THERMA-FUSER SYSTEMS

Option 2: Therma-Fuser stand alone diffusers ËRoom s Achieve benefits of Therma-Fuser VAV and monitor room air temperatures with the BAS. The BAS can read an analog room temperature signal from a sensor installed in each diffuser. The BAS also monitors and controls the portions of the VAV system requiring periodic maintenance. This approach provides the Therma-Fuser VAV advantages of comfort and energy savings from individual temperature control, easy adaptability to office changes, and no maintenance VAV terminals. Diffusers with Room s Ë Comfort - Individual temperature control Ë Comfort - Superior air distribution Ë Energy - Energy saving system Ë Sustainability - Adaptable system Ë Sustainability - No diffuser maintenance 1 Ë BAS monitors room air temperature NOTES: 1. 10-year warranty on Therma-Fuser stand alone diffusers. (Not applicable to diffuser options and accessories.) Occupancy Schedule Emergency Override Discharge Air Cooling Setpoint Discharge Air Heating Setpoint Minimum Outdoor Air Setpoint Room Temperatures Discharge Air Temperature Static Pressure Mode Chilled Water Temperature Hot Water Temperature Supply Fan Capacity Exhaust Fan Capacity Return Air Capacity Economizer Enabled Outdoor Air Temperature Outdoor Air Damper Position Outdoor Airflow Return Air Temperature Mixed Air Temperature Space Temperature Filter Differential Pressure Text in italics are VAV system possibilities. BAS inputs and outputs are available from other HVAC equipment such as the chiller, boiler, pumps, cooling tower, etc... 5

Option 3: Therma-Fuser stand alone diffusers ËWall Adjusters Achieve benefits of Therma-Fuser VAV and make room temperature set point changes with the BAS. The BAS can read and reset the room temperature setpoint of each diffuser using analog signals from an Acutherm Wall Adjuster. The Wall Adjuster may be installed on the diffuser or on the wall and may be either wireless or wired to the diffuser. The BAS also monitors and controls the portions of the VAV system requiring periodic maintenance. This approach provides the Therma-Fuser VAV advantages of comfort and energy savings from individual temperature control, easy adaptability to office changes, and no maintenance VAV terminals. Diffusers and Wired or Wireless Wall Adjusters ADJ-W Wireless Wall Adjuster ADJ-D Digital Wall Adjusters Ë Comfort - Individual temperature control Ë Comfort - Superior air distribution Ë Energy - Energy saving system Ë Sustainability - Adaptable system Ë Sustainability - No diffuser maintenance 1 Ë BAS monitors and adjusts room temperature setpoints NOTES: 1. 10-year warranty on Therma-Fuser stand alone diffusers. (Not applicable to diffuser options and accessories.) Room Temperature Setpoints Occupancy Schedule Emergency Override Discharge Air Cooling Setpoint Discharge Air Heating Setpoint Minimum Outdoor Air Setpoint Room Temperature Setpoints Discharge Air Temperature Static Pressure Mode Chilled Water Temperature Hot Water Temperature Supply Fan Capacity Exhaust Fan Capacity Return Air Capacity Economizer Enabled Outdoor Air Temperature Outdoor Air Damper Position Outdoor Airflow Return Air Temperature Mixed Air Temperature Space Temperature Filter Differential Pressure Text in italics are VAV system possibilities. BAS inputs and outputs are available from other HVAC equipment such as the chiller, boiler, pumps, cooling tower, etc... 6 BUILDING AUTOMATION OPTIONS FOR THERMA-FUSER SYSTEMS

Option 4: Therma-Fuser stand alone diffusers ËRoom s and Wall Adjusters Achieve benefits of Therma-Fuser VAV and both monitor room air temperatures and make setpoint changes with the BAS. The BAS can read an analog room temperature signal from a sensor installed in each diffuser and can read and reset the room temperature setpoint of each diffuser using analog signals from an Acutherm Wall Adjuster. The BAS also monitors and controls the portions of the VAV system requiring periodic maintenance. This approach provides the Therma-Fuser VAV advantages of comfort and energy savings from individual temperature control, easy adaptability to office changes, and no maintenance VAV terminals. Diffusers with Room s and Wired or Wireless Wall Adjusters ADJ-W Wireless Wall Adjuster ADJ-D Digital Wall Adjusters Ë Comfort - Individual temperature control Ë Comfort - Superior air distribution Ë Energy - Energy saving system Ë Sustainability - Adaptable system Ë Sustainability - No diffuser maintenance 1 Ë BAS monitors room air temperature Ë BAS monitors and adjusts room temperature setpoints 1. 10-year warranty on Therma-Fuser stand alone diffusers. (Not applicable to diffuser options and accessories.) Room Temperature Setpoints Occupancy Schedule Emergency Override Discharge Air Cooling Setpoint Discharge Air Heating Setpoint Minimum Outdoor Air Setpoint Room Temperature Setpoints Room Temperatures Discharge Air Temperature Static Pressure Mode Chilled Water Temperature Hot Water Temperature Supply Fan Capacity Exhaust Fan Capacity Return Air Capacity Economizer Enabled Outdoor Air Temperature Outdoor Air Damper Position Outdoor Airflow Return Air Temperature Mixed Air Temperature Space Temperature Filter Differential Pressure Text in italics are VAV system possibilities. BAS inputs and outputs are available from other HVAC equipment such as the chiller, boiler, pumps, cooling tower, etc... 7

Option 5: Combination of Therma-Fuser stand alone ËTherma-Fuser DDC interoperable diffusers Achieve benefits of Therma-Fuser VAV, complete digital input and output with the BAS on selected diffusers and the simplicity of no wiring to the others. Key spaces are monitored and controlled by the BAS. Other spaces have the benefit of simplicity and low installation cost due to no diffuser wiring. All spaces have the Therma-Fuser VAV advantages of comfort and energy savings from individual temperature control and easy adaptability to office changes. The BAS also monitors and controls the portions of the VAV system requiring periodic maintenance. DDC Interoperable Diffuser Diffuser Diffuser DDC Interoperable Diffuser Diffuser Diffuser Ë Comfort - Individual temperature control Ë Comfort - Superior air distribution Ë Energy - Energy saving system Ë Sustainability - Adaptable system Ë Sustainability - No diffuser maintenance 1 Ë BAS monitors room air temperature 2, 4 Ë BAS monitors and adjusts room temperature setpoints 3, 4 Ë BAS monitors diffuser supply air temperature 4 Ë BAS monitors diffuser supply air volume 4 Ë Other BAS functions (see description) 4 NOTES: 1. 10-year warranty on Therma-Fuser stand alone diffusers. (Not applicable to diffuser options and accessories.) 2. Available on Therma-Fuser stand alone diffusers with options 2 and 4. 3. Available on Therma-Fuser stand alone diffusers with options 3 and 4. 4. Only on Therma-Fuser DDC diffusers. Room Temperature Setpoints* Room Minimum Airflow Setpoints* Room Maximum Airflow Setpoints* Override Open* Override Closed* CO2 Override* Occupancy Schedule Emergency Override Discharge Air Cooling Setpoint Discharge Air Heating Setpoint Minimum Outdoor Air Setpoint *Only for select rooms Room Temperature Setpoints* Room Temperatures* Room Airflows* Room Temperatures* Discharge Air Temperature Static Pressure Mode Chilled Water Temperature Hot Water Temperature Supply Fan Capacity Exhaust Fan Capacity Return Air Capacity Economizer Enabled Outdoor Air Temperature Outdoor Air Damper Position Outdoor Airflow Return Air Temperature Mixed Air Temperature Space Temperature Filter Differential Pressure *Only for select rooms Text in italics are VAV system possibilities. BAS inputs and outputs are available from other HVAC equipment such as the chiller, boiler, pumps, cooling tower, etc... 8 BUILDING AUTOMATION OPTIONS FOR THERMA-FUSER SYSTEMS

Option 6: Therma-Fuser DDC interoperable diffusers Achieve benefits of Therma-Fuser VAV and complete digital input and output with the BAS. Each diffuser has the ability to supply room temperature, airflow and supply air temperature and receive signals for room temperature setpoint, minimum airflow setpoint, maximum airflow setpoint, override open, override closed, CO2 override and more. Digital signals can be either BACnet or LonWorks. The BAS also monitors and controls the portions of the VAV system requiring periodic maintenance. This approach provides the Therma-Fuser VAV advantages of comfort and energy savings from individual temperature control and easy adaptability to office changes. DDC Interoperable Diffusers Ë Comfort - Individual temperature control Ë Comfort - Superior air distribution Ë Energy - Energy saving system Ë Sustainability - Adaptable system Ë Sustainability - No diffuser maintenance Ë BAS monitors room air temperature Ë BAS monitors and adjusts room temperature setpoints Ë BAS monitors diffuser supply air temperature Ë BAS monitors diffuser supply air volume Ë Other BAS functions (see description) Room Temperature Setpoints Room Minimum Airflow Setpoints Room Maximum Airflow Setpoints Override Open Override Closed CO2 Override Occupancy Schedule Emergency Override Discharge Air Cooling Setpoint Discharge Air Heating Setpoint Minimum Outdoor Air Setpoint Room Temperature Setpoints Room Temperatures Room Airflows Room Temperatures Discharge Air Temperature Static Pressure Mode Chilled Water Temperature Hot Water Temperature Supply Fan Capacity Exhaust Fan Capacity Return Air Capacity Economizer Enabled Outdoor Air Temperature Outdoor Air Damper Position Outdoor Airflow Return Air Temperature Mixed Air Temperature Space Temperature Filter Differential Pressure Text in italics are VAV system possibilities. BAS inputs and outputs are available from other HVAC equipment such as the chiller, boiler, pumps, cooling tower, etc... 9

Option for Pressure Independence Module (PIM): Should the air source operate at a higher static pressure level than suitable for quiet Therma-Fuser diffuser performance, static pressure control is required. The Acutherm PIM is ideal for Therma-Fuser diffusers to operate quietly at both full flow and turndown conditions. There are two ways to integrate to the BAS system; analog (PIM) and interoperable (E-PIM). Both offer static pressure control for zone or by-pass applications. The diagrams below show zone applications. Analog & Interoperable: Override Analog & Interoperable: Static Pressure Damper Position ANALOG (PIM) Pressure Probe PIM Note: Diffusers can be or DDC Interoperable. INTEROPERABLE (E-PIM) Pressure Probe E-PIM Note: Diffusers can be or DDC Interoperable. 10

Proven Building Automation Options Integration Comfort Therma-Fuser VAV Systems offer a wide spectrum of building integration options from stand-alone diffusers that provide simple global temperature changes, requiring no energy for operation, to full-scale networking for system scheduling, monitoring, reporting and more. With each Therma-Fuser VAV diffuser acting as an individual VAV zone of control, every area of a building can have separate, optimized temperature settings. The individual occupant selects a personal comfort setting and average temperature is maintained within 1½ F/0.9 C. Therma-Fuser VAV diffusers also provide a constant discharge velocity with comfort benefits of higher throws, no dumping, better room air movement and uniform temperature distribution. Energy Savings Experience Therma-Fuser VAV diffusers allow for all low-pressure, low-energy system designs. As U.S. Green Building Council members, Acutherm is proud to produce energy efficient VAV diffusers that prevent over cooling and over heating producing 15%-47% energy savings when compared to other VAV Systems. Since 1978 Acutherm s thermally powered VAV diffusers have been exceeding people s individual comfort requirements. Our dedication to innovation began with the Acutherm Therma-Fuser VAV diffuser and continues with our associated products and accessories. Acutherm ProductS Square VAV Diffusers Round VAV Diffusers Linear VAV Diffusers Accessories Pressure Control Temperature control 11

2012 Acutherm FORM 010-112 REV 1201 For additional details on Therma-Fuser VAV system, Acutherm products or system design please contact our Engineering Department directly at (510) 785-0510 or info@acutherm.com. available online Access digital brochures, CAD files, performance data and more! www.acutherm.com CALL US Talk to our customization and specification experts +1 800 544 1840 EMAIL SUPPORT Send us your questions and we ll get you the answers you need. info@acutherm.com Acutherm Headquarters 1766 Sabre Street Hayward CA 94545, USA Tel: +1 510 785 0510 Fax: +1 510 785 2517