Instruction Manual Pocket scale

Similar documents
MEDIZINTECHNIK FÜR TIERÄRZTE

KERN KFB/KFN-TM Version /2010 GB

KERN HFT Version /2013 GB

MiniCD. User Manual. American Weigh Scales. MCD-100 (100 x 0.01g MCD-500 (500 x 0.1g)

KERN VB Version /2007

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

64C Amplification Block. Instruction Manual

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

testo 616 Appareil de mesure de l'humidité

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

DIGITAL PORTION SCALE PS-5 OWNER S Manual

High Precision Balances. Operation Manual

DS-520 Digital Indicator Operation Manual 73366

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb)

Sby SR Instruments, Inc.

ANALYTICAL BALANCES PROFESSIONAL MEASURING

D Sep ATX324 ATX224 ATX124 ATX84 ATY324 ATY224 ATY124 ATY64

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

Inscale Measurement Technology Ltd Tel: Fax:

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

DJ Switch 10F V2 ORDERCODE 50365

EGT-AF08 USER GUIDE WHEEL WEIGHING SYSTEMS WITH VARIOUS PLATFORMS

SPECIAL EQUIPMENT: SCALES TO MEET PRE-PACKAGING LEGISLATION/ATEX SCALES PROFESSIONAL MEASURING

Model M120 Mini Temperature/Humidity Meter

Owner s Manual & Safety Instructions

SPIRIT. Water purifier. Complete User Manual

OPERATING INSTRUCTIONS. Portable Turbidity Meter

HOBO Plug Load Logger (UX ) Manual

KERN MLB50-3 Version /2003

ATOMSCOPE HF200A. Operating Instruction Manual. Ver. 3.1

WS 10 Weighing indicator USER MANUAL

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

OPERATOR MANUAL. INDEX page Turning on/off the indicator Weighing Zero weighing Calibration 3

INSTRUCTION MANUAL CONTECH

Self-cleaning Turbidity Sensor

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

DATA LOGGER Model DL-SA11

Tank Scale Service Checklist

Barkeep Instructions for the Escali SmartConnect Scale

HCP-7000 Opreator s Manual 1. Operator s Manual.

Series. 3 or 12 lb. Capacity. 129 Cramer Road, Jewett, New York USA Fax:

Océ DFS10. Operator Manual

NOTES TABLE OF CONTENTS

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

Quick Guide. CSN950 MultiHead Dimensioner _v2d_MAN_QG_CSN950MH_EN

VI-D4. Concrete Moisture Meter

Owner s Manual & Safety Instructions

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Load cells Type: RTB Safety Instructions

Operator Manual. brite Advanced Retail scale

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter

Dual Port isolated USB Charger

KERN CH Version /2015 GB

Mobile Hot Food Merchandiser Series. Series: MM Operation Manual

8000 / 8100 ph Meters

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

USER MANUAL BR LED Headlight Rev /05/2016

Instruction number PTI-16-03/09/06/A

USER MANUAL. ExStik CL200A. Waterproof Total Residual Chlorine Tester. Patent Pending. Additional User Manual Translations available at

Weighloader user manual. Document reference: V2.01

MODEL BE-100HT HEADSET TELEPHONE OWNER S MANUAL PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY.

Instruction Manual HT 24 BM-D2400 Homogenizer

HY-ALERTA 500 Handheld Hydrogen Leak Detector

Owner s Manual.

Magner /35-3 Series Currency Counter. Operator's Manual

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

User s Manual. Chart Projector GCP-7000

Operating Instructions

Operating Instructions

DWP-5500FP (4 x4 ) DWP-11KRFP (5 X5 ) Weighing Indicator. User Manual. Content

Weighing Indicator YH-T3. User Manual

Instruction Manual. Filter System Bioflow 3.0, 6.0, 8.0.

OVS 512 FOR REPAIRING AND REFINING SCREED SURFACES.

Adam Equipment ADK SERIES

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Just a few clicks away from a heating system

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Installation, Operation & Maintenance Manual

SIWAREX FTC-B Weighing Module for Belt Scales Set-up of SIWAREX FTC with SIWATOOL FTC_B

Quick Guide. CSN840 Pallet Dimensioner

Installation Instructions

nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual

Instructions for use Everest scan pro, Everest scan eco, Everest scan Base Camp Typ 4101, Always be on the safe side.

Building/ Room Number: Biorenewables Research Laboratory (BRL) 1114

Instruction Manual Dräger MSI EM200-s

Ecologix Environmental Systems, LLC

OPERATION MANUAL. Electronic Hanging Scale NINGBO AUDDA WEIGHING CO.,LTD

Pre-installation Manual CONCEPT 301 D/401 D/501 D

High Temperature Vacuum Tube Furnace GSL Operational Manual

testo 330 Flue gas analysis with increased convenience and safety

Operating instructions. METTLER TOLEDO B balance line AB PB SB

Adjustable Fused Power Supply

Page 1/6. Safety Data Sheet according to 1907/2006/EC, Article 31

TECHNICAL DATA. ThreeBond Cyanoacrylate Adhesive. Features. Applications. Directions for Use

AHP WELDS USER MANUAL

RAPiD VEHICLE SAFE. Owner s Manual. Instructional videos for Hornady Security products are available at hornady.com. With patented RFID technology.

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Transcription:

KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Instruction Manual Pocket scale KERN TAB Version 1.1 03/2013 GB

GB KERN TAB Version 1.1 03/2013 Instruction Manual Pocket scale Contents 1 Technical data... 3 2 Basic Information (General)... 4 2.1 Proper use... 4 2.2 Improper Use... 4 2.3 Warranty... 4 2.4 Monitoring of Test Resources... 4 3 Basic Safety Precautions... 5 3.1 Pay attention to the instructions in the Operation Manual... 5 3.2 Personnel training... 5 4 Transportation & Storage... 5 4.1 Testing upon acceptance... 5 4.2 Packaging... 5 5 Appliance overview... 6 6 Unpacking, Setup and Commissioning... 7 6.1 Installation Site, Location of Use... 7 6.2 Unpacking... 7 6.2.1 Scope of delivery... 7 6.3 Battery operation and change... 8 6.4 Initial Commissioning... 8 6.5 Adjustment... 8 6.6 Adjusting... 8 7 Operation Mode... 9 7.1 Keyboard overview... 9 7.2 Operation... 10 7.2.1 Weighing... 10 7.2.2 Taring... 11 7.2.3 External weighing units... 12 7.3 Display background illumination... 12 8 Service, maintenance, disposal... 13 8.1 Cleaning... 13 8.2 Service, maintenance... 13 8.3 Disposal... 13 9 Instant help... 14 2

1 Technical data KERN TAB 20-3 Weighing range (max) Readability (d) Recommended adjustment weight, added Weighing Units Stabilization time (typical) Operating temperature Humidity of air Dimensions of the housing (W x D x H) [mm] 20 g 0.001 g 10 g (F2) ct, g, gn 3 sec. + 10 C. + 30 C 15 % - 80 % (non-condensing) 95 x 133 x 33 Weighing plate [mm] Ø 18 Weight (net) 200 g 3

2 Basic Information (General) 2.1 Proper use The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a non-automatic balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read. 2.2 Improper Use Do not use balance for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the stability compensation in the balance. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing plate. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damage by this. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing. 2.3 Warranty Warranty claims shall be voided in case Our conditions in the operation manual are ignored The appliance is used outside the described uses The appliance is modified or opened Mechanical damage and damage caused by media, liquids natural wear and tear The appliance is improperly set up or incorrectly electrically connected The measuring system is overloaded 2.4 Monitoring of Test Resources In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN s home page (www.kern-sohn.com) with regard to the monitoring of balance test substances and the test weights required for this. In KERN s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost. 4

3 Basic Safety Precautions 3.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances. Versions in other languages are non-binding translations. The only binding version is the original document in German. 3.2 Personnel training The appliance may only be operated and maintained by trained personnel. 4 Transportation & Storage 4.1 Testing upon acceptance When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage. 4.2 Packaging Keep all parts of the original packaging for a possibly required return. Only use original packaging for returning. Prior to dispatch disconnect all cables and remove loose/mobile parts. Reattach possibly supplied transport securing devices. Secure all parts such as the glass wind screen, the weighing platform, power unit etc. against shifting and damage. 5

5 Appliance overview 1 Wind screen / hinged cover serving as pressure and dust protection 2 Adjustment weight 3 Weighing surface 4 Weighing vessel 6

6 Unpacking, Setup and Commissioning 6.1 Installation Site, Location of Use The balances are designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance. Therefore, observe the following for the installation site: Place the balance on a firm, level surface; Avoid extreme heat as well as temperature fluctuation caused by installing next to a radiator or in the direct sunlight; Protect the balance against direct draughts due to open windows and doors; Avoid jarring during weighing; Protect the balance against high humidity, vapours and dust; Do not expose the device to extreme dampness for longer periods of time. Non-permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the appliance for ca. 2 hours at room temperature. Avoid static charge of goods to be weighed and weighing container. The occurrence of electromagnetic fields, electrostatic charging as well as instable power supply may result in considerable display variations (incorrect weighing results). In that case, the location must be changed. 6.2 Unpacking Carefully remove the balance from the packaging, remove plastic cover and setup balance at the intended workstation. 6.2.1 Scope of delivery Serial accessories: Pocket scale Batteries Instruction Manual Adjustment weight 7

6.3 Battery operation and change In order to save the battery, the balance switches automatically off after 30 seconds without weighing. If the balance is not used for a longer time, take out the batteries and store them separately. Leaking battery liquid could damage the balance. 6.4 Initial Commissioning The warm-up period after the start stabilises the measured values. The accuracy of the balance depends on the local acceleration of gravity. Strictly observe hints in chapter Adjustment. 6.5 Adjustment As the acceleration value due to gravity is not the same at every location on earth, each balance must be coordinated - in compliance with the underlying physical weighing principle - to the existing acceleration due to gravity at its place of location (only if the balance has not already been adjusted to the location in the factory). This adjustment process must be carried out during the initial start-up, after change in location and variation of surrounding temperature. To receive accurate measuring values it is also recommended to adjust the balance periodically in weighing operation. 6.6 Adjusting With an adjustment weight, the weighing accuracy can be checked and re-adjusted at any time. Procedure when adjusting: Observe stable environmental conditions. Switch on scale by on the screen and wait for 0.0 to appear Press and hold until ZERO appears flashing Confirm by pressing and the value of the adjustment weight will be shown flashing Position the adjustment weight; after a while PASS appears; this concludes the adjustment process. Afterwards the scale switches off automatically. 8

7 Operation Mode 7.1 Keyboard overview Key Description Function Short key pressing CAL-key UNIT-key TARE button ON/OFF-switch Adjusting (Press and hold key for a long time) Backlighting ON/OFF Weighing units switch-over Tare = Return display to zero Turn on/off 9

7.2 Operation 7.2.1 Weighing Start balance by pressing The balance shows for approx. 3 seconds HELLO in the display and then goes to 0.0. Now it is ready for operation. If display does not show 0, press. Put on items to be weighed, weighed value is displayed. (Example) If the material to be weighed is heavier than the weighing range, the display will show OVER" (=Overload). 10

7.2.2 Taring Press to switch on scale by and wait for 0.0 display. Put the tare vessel on the weighing plate and press the button. The scale display returns to 0.0. (Example) Pour object to be weighed into container and read the measured value. (Example) Renewed pressing of to the display screen. after the weighing process results in 0 returning The taring process can be repeated any number of times, e.g. when adding several components for a mixture (adding). The limit is reached when the whole weighing range is exhausted. After removing the taring container the total weight is displayed as negative display. 11

7.2.3 External weighing units Press to switch on scale and wait for 0.0 display. Use to select the different units g, ct und gn. Pour object to be weighed into container and read the measured value. (Example) The following weighing units are available: Gram g * ct gn 20 g 100.00 ct 308.64 gn *default setting 7.3 Display background illumination The display unit can be kept on or off. For this press shortly. 12

8 Service, maintenance, disposal 8.1 Cleaning Before cleaning, please disconnect the appliance from the operating voltage. Please do not use aggressive cleaning agents (solvents or similar agents), but a cloth dampened with mild soap suds. Ensure that no liquid penetrates into the device and wipe with a dry soft cloth. Loose residue sample/powder can be removed carefully with a brush or manual vacuum cleaner. Spilled weighing goods must be removed immediately. 8.2 Service, maintenance The appliance may only be opened by trained service technicians who are authorized by KERN. 8.3 Disposal Disposal of packaging and appliance must be carried out by operator according to valid national or regional law of the location where the appliance is used. 13

9 Instant help In case of a fault in the program sequence, the balance should be shortly switched off. The weighing process must then be restarted from the beginning. Help: Fault Possible cause The displayed weight does not glow. The balance is not switched on. Batteries are inserted incorrectly or empty No batteries inserted. The displayed weight is permanently changing Draught/air movement Table/floor vibrations The weighing plate is in contact with foreign matter. Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) The weighing value is obviously wrong The display of the balance is not at zero Adjustment is no longer correct. Great fluctuations in temperature. Electromagnetic fields / static charging (choose different location/switch off interfering device if possible) Should other error messages occur, switch balance off and then on again. If the error message remains inform manufacturer. 14