CORLAR 2.1 ST SATIN HIGH SOLIDS EPOXY MASTIC (formerly Corlar 25P )

Similar documents
Corlar 2.8 HG High Solids Epoxy

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Corlar LV PR 178 Series Epoxy Primer

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

Refer to Substrates & Surface Preparation.

Refer to Substrates & Surface Preparation.

Aliphatic Acrylic-Polyester Polyurethane

Imron 1.8 FT-C Flat Waterborne Polyurethane Clearcoat

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

Measured in accordance with ASTM D 2697.

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Rust-Oleum Industrial Brands Specification

Application Guide HI-TEMP 1027 APPLICATION GUIDE. Number: AG-3001 Revision: Page 1 of Introduction. 2. Where to apply Hi-Temp 1027

PRODUCT DATA SHEETS CUSTOM COATINGS FORMULATED TO MATCH YOUR NEEDS USCOATINGS.COM // St. Louis, Missouri

SECTION 1045 PAINT FOR STRUCTURAL STEEL

Property Test/Standard Description

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Pre-qualification testing in accordance with NORSOK M-501, Rev. 5, System 1, suitable for exterior exposure in offshore environment, below 120 C.

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

Property Test/Standard Description

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 32 C

TT-P-1757B Type I, Class C, Aerosol Zinc Chromate Primer. A one component, alkyd base, corrosion inhibiting zinc chromate primer.

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

two component high build amine adduct cured phenolic epoxy primer

TECHNICAL DATA SHEET

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 32 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Property Test/Standard Description

Date of issue: 5 October 2017 Page: 1/6

vinyl ester Property Test/Standard Description semi gloss (35-70) Flash point ISO 3679 Method 1 34 C calculated IED (2010/75/EU) (theoretical)

Property Test/Standard Description

Coronado Industrial Coatings Old County Road Edgewater, Florida FAX Line. Min Recoat:

Property Test/Standard Description

64C1-2-A High Temperature Resistant Insulative Coating

Property Test/Standard Description

Coating Types. Coating Systems. Coating Basics. Why coatings are used Component of coatings Methods of protection Service environment

10P20-14 High Solids Low IR Primer

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 25 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Pre-qualification testing in accordance with NORSOK M-501, Rev. 3/4, System 7, suitable for splash zone. Property Test/Standard Description

Eclipse ECL-G-2 Clear High Solids Polyurethane Topcoat

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

Versamid 280 B-75. Technical Data Sheet. Properties. Applications. Product Description or liquid epoxy resins.

Property Test/Standard Description

Property Test/Standard Description

Property Test/Standard Description

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

Approved. Property Test/Standard Description. high gloss (85+) Flash point ISO 3679 Method 1 30 C. US EPA method 24 (tested)

Property Test/Standard Description

58 Series Polyurethane topcoat

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

- Aromatic hydrocarbons - Binder 2,67 kg/dm³ (±0,06 Kg/dm³) Solid content - 80% by weight (±2%) - 58% by volume (±2%) according to ASTM D2697

Aerodur CF Primer 37047

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-EU EU VOC Directive 2004/42/CE (theoretical) 14 g/l

B. Paints, Sealants, Adhesives

Maximum Rust Protection!

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method C VOC-US/Hong Kong. US EPA method 24 (tested)

SIGMACAP MASTIC GF. September surface tolerant coating for lower grade of steel preparation

NAVSEA REVIEWED ASTM F-718. If this product is to be applied as part of a coating system, all components of the system must be as listed on the QPL.

Single component moisture curing polyureas Best performing corrosion resistant coatings Marine & protective coatings brochure

The required quality of surface preparation can vary depending on the area of use, expected durability and if applicable, project specification.

Instruction Guide APPLICATION OF CIM TO CONCRETE

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

GRIP-GARD PLUS BRUSH / ROLL ADDITIVE

E L A S T O - S H I E L D P R E P A R A T I O N & A P P L I C A T I O N

SP-100 Equipment Wash SP-110 Tool Cleaner

PercoTop Primer 010 CS310 / CS311 / CS312 / CS313 / CS315 / CS316 1K Primer

Corrosion Protection for Fisher Valves

MAINCOTE 1100A Emulsion Advanced Resin for Industrial Coatings based on AVANSE Technology Platform

Technical Data Jotamastic 80 MIO

SAMPLE SPECIFICATION

DPHS521 FL301. Low VOC Primer

Rust Bullet Home and Farm FAQ s

Property Test/Standard Description. Flash point ISO 3679 Method C

Heresite VR-514 TECHNICAL DATA SHEET. VR-514 Typical Properties. Our 50 years of coating history speaks for itself.

Mix ratio (by volume): (base component) (activator component) (thinner component)

PRODUCT DATA SHEET Sika Unitherm Platinum

CROMAX PRO WB9908 SUPER JET BLACK BASECOAT

NCI for Industrial Applications. Restore Highly Oxidized & Colors. Extend Freshly Painted or Existing Paint by 10+ Years

4002A21M Aluminum Lipskin Coating

Special Provision No. 911F04 March 1997

TECHNICAL DATA SHEET

Laboratory Testing of Three Above Ground Paint Systems for Canadian Applications

3M Fast Tack Water Based Adhesive 1000NF

Associated Spec Consultants, Inc. February 27, 2014 SECTION ARCHITECTURAL COATINGS

The Application Guide offers product details and recommended practices for the use of the product.

ELASTOFLEX ELASTOMERIC TEXTURED ACRYLIC WALL COATING SPECIFICATION

SURFACE PREPARATION FOR SYNTHETIC ROPES

The Application Guide offers product details and recommended practices for the use of the product.

10P2-3 Anti-static Conductive Flat Black Epoxy Coating

AROFLINT 810 Product Code: Acid Functional Polyester for Two-Package Polyester Epoxy Systems

Mult-E-Poxy 180 Epoxy Mastic

HVAC Antimicrobial Protected Coatings

Section COATING RESTORATION

RUST TRAP TM TECHNICAL DATA SHEET

DP4101 / DP4104 / DP4107 HS PRIMER

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

Two component solvent-free epoxy system for creation of self-levelling floors. Gloss >4% <70% 83mg IR4

Transcription:

SATIN HIGH SOLIDS EPOXY MASTIC (formerly Corlar 25P ) Corlar 2.1 ST is a satin gloss, high build epoxy mastic, two-package, VOC conforming product (2.1 lbs/gal) based on DuPont amido amine modified polyamide epoxy technology. The resulting highly durable coating delivers outstanding corrosion and chemical resistance. SUGGESTED USES: As a high performance direct-to-metal (DTM) coating or topcoat on carbon steel, galvanized steel, stainless steel, aluminum, concrete, concrete block and wood where: Rusted, hand or power-tool cleaned surfaces must be protected. Single coat applications up to 10 mils dry film thickness are required. Application will be made over damp surfaces and/or under conditions of high relative humidity Excellent resistance to chemical and/or marine environments is required. Outstanding abrasion resistance and edge protection are required. Application by brush and roller, in addition to spraying, may be necessary. Application must be made at temperatures as low as 35 F. No induction time and long pot life will improve productivity. Corlar 2.1 ST may also be used as a high performance tank lining on carbon steel or concrete for immersion service in near neutral ph water, fresh water, or saltwater. Corlar 2.1 ST is not recommended for use with potable water. Contact your DuPont Performance Coatings Representative for specific immersion service recommendations and procedures. NOT RECOMMENDED FOR: Immersion service in potable water, chemicals or hydrocarbons. Exterior exposure without topcoat. RECOMMENDATIONS FOR IMMERSION SERVICE: Corlar 2.1 ST when applied in multiple coats (at least 2) at 10-12 mil DFT is recommended for immersion service in near neutral, fresh or saltwater exposures. It is not recommended for use with potable water. It may be used for fire water towers, ballast tanks, clarifiers, wastewater treatment plants, offshore structures, pier pilings and supports and other areas where a high level of water resistance is required. See Additional Comment #5. COMPATIBILITY WITH OTHER COATINGS: Corlar 2.1 ST is highly compatible with most coating types. It may be used over most aged and hard cured coatings in good condition. Testing for lifting, bubbling and adhesion is recommended to assure compatibility with unknown coatings. Contact your DuPont Performance Coatings Representative for specific recommendations. MAXIMUM SERVICE TEMPERATURE: Up to 250 F Continuous 300 F Intermittent 100 F Immersion All technical advice, recommendations and services are rendered by the Seller gratis. They are based on technical data which the Seller believes to be reliable, and are intended for use by persons having skill and know-how at their own discretion and risk. Seller assumes no responsibility for results obtained or damages incurred from their use by Buyer in whole or in part. Such recommendations, technical advice or services are not to be taken as a license to operate under or intended to suggest infringement of any existing patent. Printed in U.S.A. Page 1 of 6 E-R3711/H-99679, 12/02

COLOR CHANGE/CHALKING: Corlar 2.1 ST is primarily designed for corrosion protection. Corlar 2.1 ST will chalk upon exposure to sunlight. If gloss, color retention and color stability are important, Corlar 2.1 ST should be topcoated with Imron 2.8 HG or Imron 3.5 HG, Tufcote 3.5 HG-NI or other appropriate topcoat. In high temperature applications, some yellowing may occur. See Additional Comment #8. PERFORMANCE PROPERTIES: Abrasion Excellent Acids Very Good Alkalis Excellent Ammonia Excellent Humidity Salts Solvents Weather VOLATILE ORGANIC CONTENT (VOC) THEORETICAL: % VOC VOC Condition Thinner Max (lbs/gal)* (g/l)* Airless Normal Y32035 2-5 2.3 276 Conventional Y32035 7-10 2.5 300 Max. Pot Life Y32035 15 2.7 324 RT001P 15 2.8 336 Hot & Windy T-8054 10-15 2.8 336 Brush & Roll RT001P 10-15 2.8 336 Mixed Unthinned* 2.1 252 Excellent Excellent Excellent Very Good (will chalk on exterior exposure) *Reported values at higher level of reduction (theoretical/ave.) Reported values are average Across Color Range. COLOR: Various. Select Factory Packaged colors and custom mixes available. GLOSS: Satin Finish CURE TIME HOURS @ 50% R.H. @ 5 MILS SUGGESTED DFT 50 F (10 C) 70 F (21 C) 90 F (32 C) To Touch 3-4 2-3 1-2 To Handle 8 4 2 To Recoat 5 3 2 Full Cure 14 Days 7 Days 4 Days THEORETICAL COVERAGE PER GALLON: 1155 ft. 2 @ 1 mil DFT 230 ft. 2 @ 5 mils DFT 115 ft. 2 @ 10 mils DFT *Material losses during mixing and application will vary and must be taken into consideration when estimating job requirements. SUGGESTED FILM BUILD (DFT): Single Coat 5-8 mils in noncorrosive environment 10-12 mils in corrosive environment Primer 3-8 mils Mid Coat 4-6 mils Immersion 10-12 mils Printed in U.S.A. Page 2 of 6 E-R3711/H-99679, 12/02

VOLUME SOLIDS (MIXED) VARIES WITH COLOR: 72 ± 2% WEIGHT SOLIDS (MIXED) VARIES WITH COLOR: 83 ± 2% WEIGHT PER GALLON (MIXED) VARIES WITH COLOR: 11.8 ± 2 Lb. Avg. 5.4 Kg FLASH POINT (TAG CLOSED CUP): Corlar 2.1 ST Bases > 100 F Corlar VF-525 < 73 F PACKAGING: 1 & 5 gallon containers SHIPPING WEIGHT (LBS.) APPROXIMATE: 1 gallon container: 14 (base) / 11 (activator); 5 gallon container: 63 (base) / 55 (activator) SHELF LIFE & STORAGE CONDITIONS: Store in a dry, well ventilated area, storage temperatures should be between -30 F (-34 C) and 120 F (48 C) Shelf Life 1 year minimum Corlar 2.1 ST may settle. Agitate before each use and intermittently while sitting in storage. SAFETY: Consult the Material Safety Data Sheet for this product prior to use. Printed in U.S.A. Page 3 of 6 E-R3711/H-99679, 12/02

APPLICATION INSTRUCTIONS SURFACE PREPARATION: For atmospheric service, an SSPC-SP 6 Commercial Blast Cleaning is preferred for optimal performance. If not possible or practical, then Hand Tool Clean to an SSPC-SP 2 or Power Tool Clean to an SSPC-SP 3. For immersion service, an SSPC-SP 5 White Metal Blast is required. ACTIVATION: Add 1 part Corlar VF-525 activator to 1 part Corlar 2.1 ST (25P ) base. Mix until thoroughly blended. You may begin painting immediately there is no induction time. POT LIFE: 8 hours @ 70 F to 90 F when reduced 15% by volume with DuPont Y-32035 or DuPont RT001P Thinner. REDUCTION: 2-5% of DuPont Y-32035 is required under normal conditions for airless spray. 7-10% with DuPont Y-32035 is the suggested level of thinning for conventional spray. For maximum pot life, reduce 15% by volume with DuPont Y- 32035 or DuPont RT001P. Use 10-15% DuPont T-8054 Thinner in hot or windy conditions for spray application. Reduce 10-15% with RT001P Thinner when applying by roller or brush. If more reduction is required, consult your local DuPont Performance Coatings Representative. See Additional Comments #2 APPLICATION THINNERS: Normal Conditions DuPont Y-32035 Hot or Windy Conditions DuPont T-8054 (spray) Brush or Roll DuPont RT001P CLEAN UP THINNERS: DuPont T-8054 or MEK APPLICATION CONDITIONS: Do not apply if material, substrate or ambient temperature is below 35 F (2 C) or above 100 F (38 C). APPLICATION EQUIPMENT: Apply by brush, roll, or spray Manufacturers listed below are a guide. Others may be used. Changes in pressure and tip size may be required to achieve proper application. BRUSH & ROLL: ½"- ¾" nap Wooster Pro/Doo-Z roller cover. Keep roll wet. Roll in one direction, rewet, then cross roll. 3-4 Wooster China Bristle Brush CONVENTIONAL SPRAY: Binks DeVilbiss Sata Spray Gun: 2001 JGA K3RP Fluid Nozzle: 67SS D (2.2) 1.1 Pot Pressure: 25 Atomizing Pressure 36 Air Cap: 67PB 64 HD Printed in U.S.A. Page 4 of 6 E-R3711/H-99679, 12/02

HVLP SPRAY: Binks DeVilbiss Spray Gun: Mach 1 GTi Fluid Nozzle: 905 (2.3) 2.0 Air Cap: 905P 2000 AIRLESS SPRAY: Pump: Graco Extreme 33:1 Airless Gun: Graco 207945 Fluid Hose: 3/8" x 50' max. Tips: 414-527 Minimum pressure to avoid fingering: 2400 psi min. ADDITIONAL COMMENTS: 1. USDA approved. 2. At 15% reduction, reduced maximum film thickness will be obtained. 3. If using D fluid nozzle, minimize reduction to avoid runs and sags. 4. Recoating of Corlar 2.1 ST should be done as soon as possible after dry to touch, a minimum of 3-5 hours at 70 F, up to overnight. If you cannot recoat within 7 days up to 30 days, and you have not exposed the Corlar 2.1 ST to strong exterior sunlight and elevated temperatures over 100 F, you should water wash with a minimum of 1500 psi to remove any surface contamination. If you cannot recoat before 30 days and have exposed the Corlar 2.1 ST surfaces to exterior sunlight and elevated temperatures over 100 F, you should either: Option 1: Water wash the surface with 1500 psi and apply 1-2 mils DFT tack-mist coat Corlar 2.1 ST over the Corlar 2.1 ST painted surface and topcoat within 3-5 hours up to overnight, or Option 2: Water wash the surface with 1500 psi and abrasively brush-blast to an SSPC-SP7 (sweep-blast) and topcoat within 3-5 hours up to overnight. 5. Do not roll for immersion applications. Spray apply only. 6. When applying over inorganic zinc primers, a mist coat is recommended for best results to minimize bubbling. Apply a mist coat and allow bubbles to break. Apply a full wet coat after mist coat. 7. Under certain high humidity and low temperature conditions, an amine blush is possible. This blush should be removed before proceeding with next coat by wiping surface with an alcohol-based solvent. 8. Epoxies chalk with extended exposure to sunlight. Lack of ventilation, incomplete mixing, miscatalyzation or the use of heaters that emit carbon dioxide and carbon monoxide during application and initial stages of curing may cause yellowing to occur. 9. For intermittent service temperatures above 250 F, do not topcoat. 10. Custom color bases are short filled to allow for colorant addition 1LB25P Light base (124 oz/gal) 2MB25P Medium base (120 oz/gal) 3DB25P Deep base (116 oz/gal) 4NB25P Neutral base (112 oz/gal) Printed in U.S.A. Page 5 of 6 E-R3711/H-99679, 12/02

ASTM INFORMATION Physical properties are averages. Properties for Corlar 2.1 ST are enhanced when used in conjunction with topcoats such as Imron polyurethane or applied at higher film builds. The results listed below are obtained when applying Corlar 2.1 ST (gray) to 5.1 mils DFT. For specific system results, contact DuPont Technical Service at 1-800-3DUPONT. Paint System Corlar 2.1 ST Type/Color Epoxy/Gray DFT 5.1 Salt Fog (ASTM B117) 1000 hours no rusting, no blisters 2000 hours no rusting, few #2 blisters at the scribe 3000 hours no rusting, no undercutting at the scribe, medium #2 blisters at the scribe Relative Humidity (ASTM D2247) 1000 hours no rusting, no blisters 2000 hours no rusting, no blisters 3000 hours no rusting, no blisters Dry Heat (ASTM D2485) 250 F for 24 hours no cracking, very slight loss of adhesion, slight discoloration Electrical Resistance (ASTM D2457): 28.3X10^17 Adhesion (ASTM D4521 A2): 1834 psi adhesion failure between coating and substrate Cleveland Cond (ASTM D4585): 1000 hours no rusting, no blisters, no delamination UV Con (ASTM D4587)* 3000 hours Gloss before exposure 48.9 Gloss after exposure 1.5 Evaluation no rusting, no blisters, no delamination Impact (ASTM D2794): 3 inch pounds Mandrel Bend (ASTM D522): % Elongation - 0% Taber Abrasion (ASTM D4060): weight loss in grams -.07 *8 hr UV @ 50 C, 4 hr condensation @ 40 C, gloss readings @ 60 Printed in U.S.A. Page 6 of 6 E-R3711/H-99679, 12/02